Abstract
In this study, we developed a visual and rapid assay for the detection of MON88017 maize using the LAMP method. The LAMP method was specific for MON88017 event and takes only 40 min and the LAMP assay sensitivity is about 40 copies, which is the same level as that of conventional PCR method. LAMP amplicons can directly be detected by naked-eye inspection after adding SYBR Green I. In summary, the LAMP method is visual, faster, and more sensitive and does not need special equipment compared to the traditional PCR technique, which makes it a very higher efficiency approach for field tests and fast screening of GMO crops, especially for on-site, large-scale testing purposes in the field.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Modern plant breeding techniques have revolutionized agro-food industry by introducing genetically modified organisms (GMOs) with the aim to improve the agricultural practices and nutritional quality [5]. A large number of GM crops with new beneficial traits have been developed by integration of foreign genes into the plant genomes. Since 1996, the planting area and events of GM crops have been continuously increased. In 2014, a record 181.5 million hectares of biotech crops were grown globally, an increase of more than six million hectares from 2013 [14], and global hectarage has increased more than 100-fold since the first plantings of biotech crops according to a report released by the International Service for the Acquisition of Agri-Biotech Applications (ISAAA). GM maize is also grown on a big scale in the USA, Brazil, Argentina and so on. There are two important traits in GM maize production, one is the resistance to insect damage such as MON88017, 59122, Bt11, MON810 and Bt176, and the other is particular tolerance to herbicide such as MON88017 and NK603. Therefore, MON88017 is more likely to be widely cultivated in the future.
Nowadays, it is a growing controversy: Should GMO foods always be labeled so consumers are aware that the product contains genetically modified ingredients? Increasingly, consumers are interested in GMO monitoring and labeling. To ensure the consumer’s choice of freedom, many countries have established regulatory systems and labeling regulations for GM food [34]. To protect the “right to know” of consumers for the GMO products, in several groups and countries, GMO labeling policies have been instituted and stated that the GMO products must be labeled when they are above the threshold between 0 and 5 % [10]. Therefore, to guarantee the GMO traceability, the stricter laws must rely on more accurate and efficient methods for detecting GMOs in raw materials as well as in highly processed food and feed. Loop-mediated isothermal amplification (LAMP) is an isothermal nucleic acid amplification test that can be used in fields with resource-limited settings. Since LAMP method was first reported in 2000 [24], the number of studies performed using LAMP to detect the GMO ingredient is increasing every year. The direct evidence on the LAMP robustness is its application for the detection of GMO crops [2, 9, 13, 18, 20, 22, 35, 39]. However, to date, only one conventional multiplex qualitative PCR method [25] and one quantification PCR method [6] have been developed for MON88017 and no report of LAMP detection method for it. In this study, we aimed to establish a sensitive, specific and rapid LAMP method to detect the flanking sequence of exogenous gene in GM maize MON88017.
Materials and methods
Plant materials
The 10 % (w/w) GM maize MON88017 was purchased from CRM/CM Information center of China, and the other 1.0 % (w/w) GM crop samples: GM maize (MON88017, MON863 and NK603), GM soybean (GTS 40-3-2 and MON89788), GM rice (TT51-1 and Kefeng 6), GM cotton (MON1445 and MON88913), GM canola (GT73) and GM sugar beet (H7-1) were supplied by the Center of Science and Technology Development, Ministry of Agriculture of China. Non-GM maize was purchased from the local market in Harbin, China.
Primer design
The primers were designed according to the 5′ border sequence in MON88017 corn obtained from the GMDD database (http://gmdd.shgmo.org/event/view/85). The LAMP primer set was designed by the online software http://primerexplorer.jp/e, including two outer primers (F3 and B3), a forward inner primer FIP (F1c + F2) and a backward inner primer BIP (B1c + B2). The detailed locations of LAMP primers in the target genome DNA sequence are shown in Fig. 1.
DNA extraction and purification
The plant genomic DNAs were isolated and purified from 100 mg sample of above compounds using Plant Genomic DNA Extraction Kit (Tiangen, China) according to the manufacturer’s instructions. The quantity and quality of DNA were initially determined by measuring the absorption at 260 nm and the absorption ratio of 260/280 nm with a Nano-100 spectrometer (Allsheng, China). And the concentrations of all samples have been accurately determined as 100 ng/μL by dilutions of template with ddH2O.
LAMP reaction assay
The LAMP reaction was carried out in a total of 25 μL solution containing 1× ThermoPol buffer, 0.2 μM each outer primer F3 (5′-AGAATCGTGTGACAACGC-3′) and B3 (5′-GGTAATTACTCTTTCTTTTTCTCC-3′), 1.2 μM each inner primer FIP (5′-TCGTCACCGTCATACTCCGGTAGCAGCTCTCCTCCAAC-3′) and BIP (5′-AATTGTAAATGGCTTCATGTCCGGATATTGACCATCATACTCATTGC-3′), 0.4 mM dNTPs (TaKaRa, China), 1.0 M betaine (Sigma, St. Louis, MO, USA), 2 mM MgSO4, 8 U/μL Bst DNA polymerase large fragment (New England Biolabs, USA) and 1 μL (100 ng) target DNA. The mixture was incubated at 63 °C for 35 min and then heated at 80 °C for 5 min to terminate the reaction. The LAMP assay was carried out in triplicate, and the no template control (NTC) contained ddH2O instead of the template.
Detection of LAMP products
The LAMP amplified products were directly watched by the naked eye through adding 2 μL of 1/10-diluted original SYBR Green I (10,000×) (Sigma, USA) into the reaction tube to observe the change in color. The mixtures were visually inspected and photographed under the natural light. In addition, a portion of each product was analyzed by 2 % agarose gel electrophoresis stained with ethidium bromide (EB) and photographed using a Multi-Image (Alpha, USA). The variation in the color was visually observed in the positive, negative and NTC reaction products.
Conventional PCR assay
Conventional PCR was also established to compare the specificity and sensitivity with the developed LAMP method. The primers employed for conventional PCR were MON88017 LF/LR. The expected product size was 199 bp. The 20 μL volume PCR mixture contained 1× rTaq buffer (TaKaRa, China), 0.25 mM each dNTP, 0.25 μM each primer (MON88017-LF: TTGTCCTGAACCCCTAAAATCC and MON88017-LR: CCCGGACATGAA GCCATTTA), 1 U rTaq DNA polymerase (TaKaRa, China) and 1 μL template DNA (100 ng). Each reaction was initially denatured at 95 °C for 5 min, followed by 35 cycles of 95 °C for 30 s, 56 °C for 30 s and 72 °C for 30 s and a final extension at 72 °C for 5 min using a LabCycler SensoQuest (SENSO, Germany). PCR products were electrophoresed in a 2 % agarose gel and photographed.
Specificity of LAMP system
In the specificity test, 100 ng total GM maize MON88017 (1.0 %, w/w), non-GM maize and other ten GM crops (including MON863, NK603, GTS 40-3-2, MON89788, TT51-1, Kefeng 6, MON1445, MON88913, GT73 and H7-1) genomic DNAs (1.0 %, w/w) were used as templates in each LAMP assay under the optimized conditions. In addition, non-GM maize template was used as negative control, and template DNA was replaced by ddH2O as NTC.
Limit of detection (LOD) of LAMP system
To test the LOD of the established LAMP assay, eight different folds dilutions of MON88017 genomic DNA template (4000, 2000, 400, 200, 40, 20, 4 and 2 copies/μL) and 1 μL of each concentration were used as template for the LAMP reactions. According to the mean molecular weight and size of the maize genome (Zea mays, 2.73 pg/genome or copy) [29], 1 ng maize DNA equals approximately 366 copies of DNA. In the DNA template, the concentration of the “first DNA mixture” maize haploid genomic DNA was 4000 copies/μL. The “first DNA mixture” was serially diluted in ddH2O to final concentrations of 2000, 400, 200, 40, 20, 4 and 2 copies/μL of total maize haploid genomic DNA, respectively. Each sample was amplified in three parallel reactions, and the entire experiment was repeated three times.
Application of the LAMP system for MON88017 maize in practical samples
To evaluate the LAMP system method for GM maize MON88017, DNAs of seven maize-derived samples (corn kernel, maize juice, corn flakes, maize meal, maize noodle, popcorn and maize starch) and one artificially mixed sample were prepared and exogenous ingredient of MON88017 was detected by this LAMP system. In each reaction, a total of 100 ng genomic DNA was amplified, and three replicates were carried out per sample.
Results and discussion
Optimization of this LAMP system
In this LAMP assay, auto-cycling strand displacement DNA synthesis is carried out by a Bst DNA polymerase with high strand displacement activity, and a set of four special primers (F3, B3, FIP, BIP) can recognize a total of six distinct regions on each of the target DNA sequences of MON88017. The final products are known to be cauliflower-like structures with multiple overhangs and loops, which can be observed during agarose gel separation of LAMP products [33]. So, the LAMP amplicons detected by gel electrophoresis exhibited ladder-like multiple bands. In this study, when the reaction temperature was between 61 and 65 °C, agarose gel electrophoresis showed visible ladder-like DNA fragments (Fig. 2). However, there were more intense ladder-like bands at the temperature of 63 °C. The above result demonstrated that 63 °C should be the optimized LAMP reaction temperature of MON88017. After adding SYBR Green I to the reaction tubes, the positive LAMP reaction was also observed by visualization of a color change (from orange to green) following the addition of diluted SYBR Green I dye (Fig. 3a).
Specificity analysis of LAMP system
The LAMP assays have been used to identify GMO events, such as soybean [31], maize [1, 35, 36, 38], rice [19], wheat [3], cotton [17, 20] and transgenic target DNA [7, 15, 26]. To assess the event specificity of this MON88017 LAMP detection system, different GM crops, including MON88017, MON863, NK603, GTS 40-3-2, MON89788, TT51-1, Kefeng 6, MON1445, MON88913, GT73 and H7-1, were used to perform LAMP assays. All DNA templates except MON88017, especially the other six GM event DNAs (MON1445, NK603, GTS 40-3-2, MON89788, GT73 and H7-1) carrying the Cp4-epsps gene, failed to amplify the target fragment and observed changed color by this LAMP assay (Fig. 3a), which has proved to be event-specific in the detection of MON88017 maize. This result indicates that the LAMP detection system could specifically amplify the MON88017 event-specific target fragment. To make sure that the expected target was amplified, a traditional PCR was performed using primer set of MON88017-LF and MON88017-LR–MON88017 DNA. Then, a 199-bp amplicon was successful obtained (Fig. 3b). So, the result of the conventional PCR was consistent with that of the LAMP assay (Fig. 3a–c).
Sensitivity analysis of LAMP system
That LAMP is able to detect very small amounts of target and does that even in high amounts of background DNA makes it ideal for GMO detection [17]. To evaluate the relative sensitivity of the assay, LAMP and PCR were carried out using a series of dilutions of MON88017 DNA ranging from 4000 to 2 copies. Positive LAMP amplifications were observed up to dilutions to 40 copies per reaction, as detected by both gel electrophoresis and SYBR Green I staining (Fig. 4a, b). Conventional PCR provided positive results up to dilutions to 40 copies per reaction, as indicated by the presence of an expected amplicon (199 bp) after gel electrophoresis (Fig. 4c). Sensitivity assay revealed that 40 copies of the MON88017 genome could be detected by this method at genome DNA level, which had the same sensitivity as conventional PCR (40 copies) for the detection of MON88017 and similar to nested PCR [37]. The detection limitation was consistent with other reported LAMP assays [13, 20] and close to the sensitivity of real-time PCR for the detection of some other GM crops [18, 30].
Analyses of mixed samples using this MON88017 LAMP system
Seven maize processed food samples and one artificially mixed sample, which was made by spiking MON88017 maize powder into non-GM maize powder and heating up the mixture, were subjected to this LAMP assay. Our results showed that all ten samples contained zSSIIb gene (Fig. 5a), which confirmed that all samples tested contained maize ingredient. Seven maize processed product samples were negative for MON88017 maize, whereas artificially mixed sample was positive. Similar results were obtained by the addition of SYBR Green I dye (Fig. 5b, c). Therefore, this inexpensive, rapid and visible LAMP protocol for MON88017 is significant for GMO detection. Accordingly, this LAMP method can be used as a powerful GMO detection tool for MON88017 maize and its derivates, due to its high specificity, sensitivity and practicability under isothermal condition.
Conclusion
At present, to guarantee the GMO traceability, a number of new approaches for GMO detection have been developed, such as PCR capillary gel electrophoresis (CGE) [11, 12], microarrays technology [28], Luminex technology [4, 8], digital PCR [16, 23] and next-generation sequencing [21, 32], PCR-ELISA [27]. The cost efficiency and high-throughput could also be achieved by the combinatory SYBR Green qPCR and matrix-based approach. Therefore, LAMP techniques have been applied for qualitative detection and identification GMOs [36, 38]. In this study, a rapid LAMP method was successfully developed for the detection of event-specific sequence in GM maize MON88017. Compared to the conventional PCR method, the LAMP system established in this study could be performed within 40 min. Furthermore, the LOD of this LAMP system for identifying MON88017 is as low as 40 copies, indicating that the LAMP system had the same sensitivity as the general PCR approach. In addition, the LAMP reaction results could be determined by the naked-eye observation without any time-consuming gel electrophoresis.
In conclusion, the MON88017 LAMP detection method established in this study is prompt, visual, specific, accurate, low cost, identical sensitive and does not need special equipment compared to conventional PCR technique, which is very necessary for field tests and fast screening of GM maize. Since the assays are performed at one temperature, the LAMP reactions of GMO products can used as a convenient tool for GM maize detection without electrophoretic analysis.
References
Chen L, Guo J, Wang Q, Kai G, Yang L (2011) Development of the visual loop-mediated isothermal amplification assays for seven genetically modified maize events and their application in practical samples analysis. J Agric Food Chem 59:5914–5918
Chen X, Wang X, Jin N, Zhou Y, Huang S, Miao Q (2012) Endpoint visual detection of three genetically modified rice events by loop-mediated isothermal amplification. Int J Mol Sci 13:14421–14433
Cheng Y, Zhang MH, Hu K, Sun FD, Tao R, Gao XJ, Luan FX (2014) Loop-mediated isothermal amplification for the event-specific detection of wheat B73-6-1. Food Anal Methods 7:500–505
Choi SH (2011) Hexaplex PCR assay and liquid bead array for detection of stacked genetically modified cotton event 281-24-236 × 3006-210-23. Anal Bioanal Chem 401(2):647–655
Datukishvili N, Kutateladze T, Gabriadze I, Bitskinashvili K, Vishnepolsky B (2015) New multiplex PCR methods for rapid screening of genetically modified organisms in foods. Front Microbiol 6:757. doi:10.3389/fmicb.2015.00757
Delobel C, Foti N, Grazioli E (2013) Event-specific method for the quantification of maize line MON88017 using real-time PCR v. 1.01. Publications Office of the European Union, Luxembourg
Feng J, Tang S, Liu L, Kuang X, Wang X, Hu S, You S (2015) Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs). Int J Food Sci Nutr 66(2):186–196
Fu K, Huang W, Deng T, Li F, Liu H, Chen Y (2015) Multiplex PCR assay and liquid bead array for detection of 13 lines genetically modified maize. J Chin Inst Food Sci Technol 15(1):188–197
Guan X, Guo J, Shen P, Yang L (2010) Visual and rapid detection of two genetically modified soybean events using loop-mediated isothermal amplification method. DNA Seq 3:313–320
Gruère GP, Rao SR (2007) A review of international labeling policies of genetically modified food to evaluate India’s proposed rule. AgBioForum 10(1):51–64
Heide BR, Heir E, Holck A (2008) Detection of eight GMO maize events by qualitative, multiplex PCR and fluorescence capillary gel electrophoresis. Eur Food Res Technol 227(2):527–535
Holck AL, Pedersen BO (2011) Simple, sensitive, accurate multiplex quantitative competitive PCR with capillary electrophoresis detection for the determination of genetically modified maize. Eur Food Res Technol 233(6):951–961
Huang X, Chen L, Xu J, Ji H, Zhu S, Chen H (2014) Rapid visual detection of phytase gene in genetically modified maize using loop-mediated isothermal amplification method. Food Chem 156:184–189
James C (2014) Global status of commercialized Biotech/GM crops. ISAAA Briefs 2014:49
Kiddle G, Hardinge P, Buttigieg N, Gandelman O, Pereira C, Mcelgunn CJ (2012) GMO detection using a bioluminescent real time reporter (BART) of loop mediated isothermal amplification (LAMP) suitable for field use. BMC Biotechnol 12(1):15–27
Köppel R, Bucher T (2015) Rapid establishment of droplet digital PCR for quantitative GMO analysis. Eur Food Res Technol 241(3):427–439
Lee D, Mura ML, Allnutt TR, Powell W (2009) Detection of genetically modified organisms (GMOs) using isothermal amplification of target DNA sequences. BMC Biotechnol 7:1–7
Li F, Yan W, Long L, Qi X, Li C, Zhang S (2014) Development and application of loop-mediated isothermal amplification assays for rapid visual detection of cry2Ab and cry3A genes in genetically-modified crops. Int J Mol Sci 15:15109a–15121a
Li Q, Fang J, Liu X (2013) Loop-mediated isothermal amplification (LAMP) method for rapid detection of cry1Ab gene in transgenic rice (Oryza sativa L.). Eur Food Res Technol 236:589–598
Li X, Wang X, Yang J, Liu Y, He Y, Pan L (2014) A novel quadruplex real-time PCR method for simultaneous detection of Cry2Ae and two genetically modified cotton events (GHB119 and T304-40). BMC Biotechnol 14:43b
Liang C, van Dijk JP, Scholtens IM, Staats M, Prins TW, Voorhuijzen MM, da Silva AM, Arisi AC, den Dunnen JT, Kok EJ (2014) Detecting authorized and unauthorized genetically modified organisms containing vip3A by real-time PCR and next-generation sequencing. Anal Bioanal Chem 406(11):2603–2611
Liu M, Luo Y, Tao R, He R, Jiang K, Wang B, Wang L (2009) Sensitive and rapid detection of genetic modified soybean (Roundup Ready) by loop-mediated isothermal amplification. Biosci Biotechnol Biochem 73(11):2365–2369
Morisset D, Štebih D, Milavec M, Gruden K, Žel J (2013) Quantitative analysis of food and feed samples with droplet digital PCR. PLoS One 8(5):e62583
Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T (2000) Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 28:e63
Oguchi T, Onishi M, Mano J, Akiyama H, Teshima R, Futo S, Furui S, Kitta K (2010) Development of multiplex PCR method for simultaneous detection of four events of genetically modified maize: DAS-59122-7, MIR604, MON863 and MON88017. Shokuhin Eiseigaku Zasshi 51(3):92–100
Paper O (2004) Real-time loop-mediated isothermal amplification for the CaMV-35S promoter as a screening method for genetically modified organisms. Eur Food Res Technol 218:496–500
Santiago-Felipe S, Tortajada-Genaro LA, Puchades R, Maquieira A (2014) Recombinase polymerase and enzyme-linked immunosorbent assay as a DNA amplification-detection strategy for food analysis. Anal Chim Acta 811:81–87
Shao N, Jiang SM, Zhang M, Wang J, Guo SJ, Li Y, Jiang HW, Liu CX, Zhang DB, Yang LT, Tao SC (2014) MACRO: a combined microchip-PCR and microarray system for high-throughput monitoring of genetically modified organisms. Anal Chem 86(2):1269–1276
Swigonová Z, Bennetzen JL, Messing J (2005) Structure and evolution of the r/b chromosomal regions in rice, maize and sorghum. Genetics 169(2):891–906
Treml D, Venturelli GL, Brod FC, Faria JC, Arisi AC (2014) Development of an event-specific hydrolysis probe quantitative real-time polymerase chain reaction assay for Embrapa 5.1 genetically modified common bean (Phaseolus vulgaris). J Agric Food Chem 62(49):11994–12000
Wang X, Tian F, Guan Q, Wang J (2012) Comparison of three DNA extraction methods for feed products and four amplification methods for the 5′-junction fragment of Roundup Ready soybean. J Agric Food Chem 60:4586–4595
Willems S, Fraiture MA, Deforce D, De Keersmaecker SC, De Loose M, Ruttink T, Herman P, Van Nieuwerburgh F, Roosens N (2016) Statistical framework for detection of genetically modified organisms based on next generation sequencing. Food Chem 192:788–798
Woźniakowski G, Kozdruń W, Samorek-Salamonowicz E (2012) Loop-mediated isothermal amplification for the detection of goose circovirus. Virol J 9:110–120
Wunderlich S, Gatto KA (2015) Consumer perception of genetically modified organisms and sources of information. Adv Nutr 6(6):842–851
Xu J, Zheng Q, Yu L, Liu R, Zhao X, Wang G (2013) Loop-mediated isothermal amplification (LAMP) method for detection of genetically modified maize T25. Int J Food Sci Nutr 1(6):432–438
Zhang F, Wang L, Wang R, Ying Y, Wu J (2015) Simple screening strategy with only water bath needed for the identification of insect-resistant genetically modified rice. Anal Chem 87(3):1523–1526
Zhang M, Liu Y, Chen L, Quan S, Jiang S, Zhang D (2013) One simple DNA extraction device and its combination with modified visual loop-mediated isothermal amplification for rapid on-field detection of genetically modified organisms. Anal Chem 85:75–82
Zhang M, Zhen Z, Yu Y, Gao X, Liu Y (2015) Development of a rapid event-specific loop-mediated isothermal amplification detection method for genetically modified maize NK603. Food Anal Method. doi:10.1007/s12161-015-0244-1
Zhou D, Guo J, Xu L, Gao S, Lin Q, Wu Q, Wu L, Que Y (2014) Establishment and application of a loop-mediated isothermal amplification (LAMP) system for detection of cry1Ac transgenic sugarcane. Sci Rep 9(4):4912–4919
Acknowledgments
This study was supported by Natural Science Foundation of Heilongjiang Province of China (No. C2015003), National Natural Science Foundation of China (No. J1210069), Doctor Scientific Research Initial Foundation of Northeast Agricultural University (No. 2012RCB19) and the Discipline Team Construction Project of Northeast Agricultural University.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare no conflict of interest.
Compliance with ethics requirements
This article does not contain any studies with human or animal subjects.
Informed consent
Not applicable.
Rights and permissions
About this article
Cite this article
Zhen, Z., Zhang, M., Yu, Y. et al. Establishment of a loop-mediated isothermal amplification (LAMP) detection method for genetically modified maize MON88017. Eur Food Res Technol 242, 1787–1793 (2016). https://doi.org/10.1007/s00217-016-2678-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00217-016-2678-0