Abstract
This review describes recent advances in the use of carbon nanomaterials for electroanalytical detection of biogenic amines (BAs). It starts with a short introduction into carbon nanomaterials such as carbon nanotubes, graphene, nanodiamonds, carbon nanofibers, fullerenes, and their composites. Next, electrochemical sensing schemes are discussed for various BAs including dopamine, serotonin, epinephrine, norepinephrine, tyramine, histamine and putrescine. Examples are then given for methods for simultaneous detection of various BAs. Finally, we discuss the current and future challenges of carbon nanomaterial-based electrochemical sensors for BAs. The review contains 175 references.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Biogenic amines (BA) are low-molecular-mass biogenic substances with one or more amine groups, which display important biological activities. They exist in many foods, in which they are mainly produced by microbial decarboxylation of amino acids or by animation and transamination of aldehydes and ketones [1, 2]. Generally, BA are classified into two distinctive categories: endogenous and exogenous BA. Endogenous amines are produced in many different tissues (for example: adrenaline in adrenal medulla, dopamine in head issuing grave and the pituitary gland and histamine in mast cells and liver). These amines are transmitted locally or via the blood system. The exogenous amines are directly absorbed from food in the intestine. They can be found at low concentrations in non-fermented food such as fruits, vegetables, meat, fish, chocolate, milk and at high concentrations in fermented foods as a result of a contaminating microflora exhibiting amino acid decarboxylase activity. BA are of concern in relation to food hygiene. High amounts of certain amines may be found in food as a consequence of the use of poor quality raw materials, contamination and inappropriate conditions during food processing and storage [3, 7]. BA are potentially toxic organic compounds, trace BA are normal active ingredient in the human body and play important physiological functions in human cells, but excessive intake of BA (especially at the same time intake of a variety of BA) will cause a series of allergic reactions, such as headache, nausea, palpitations, hypertension, and respiratory disorders even life-threatening conditions. Therefore, the importance of the estimation of the levels of BA in food and beverage is linked with their impact on food quality and human health.
Several authors reviewed the occurrence of BA in food [4–6] and as well as their analytical methods [7]. Until now, BA has been determined by several techniques such as thin-layer chromatography (TLC) [8, 9], gas chromatography (GC) [10, 11], high performance liquid chromatography (HPLC) [12, 13], ion chromatography (IC) [14, 15], capillary electrophoresis (CE) [16, 17]. Although these methods can offer good selectivity and low limit of detection (LOD), they often require complex pretreatment steps and expensive instrumentations. Thus, alternative approaches for BA detection are necessary. Electrochemical sensors provide a crucial analytical tool as demand for sensitive, rapid, and selective determination of analytes increases. Unlike spectroscopic and chromatographic instruments, electrochemical sensors can be easily adapted for detecting a wide range of analytes, while remaining inexpensive. Additionally, these sensors are capable of being incorporated into robust, portable, or miniaturized devices, enabling tailoring for particular applications. So it will be promising to apply electrochemical technology and develop novel sensors for the fast and sensitive determination of BA.
Nanomaterials with sizes or features ranging from 1 to 100 nm in one or more dimensions [18, 19] have attracted strong scientific and technological interests in recent years. They have shown great promise in many applications of analytical chemistry, such as in sample preparation [20, 21], separation [22, 23], and sensing [24–26] because of the unusual mechanical, electrical, electronic, optical, magnetic, surface and biological properties not found in conventional materials. In the analytical chemistry field, the huge interests in nanomaterials are driven by their exceptional properties. Apart from high mechanical strength, low weight, unique size and structure, their surface properties (area, roughness, energetics, and electron distributions) [27], which enable improved interactions with many biological entities [28], offer excellent prospects for designing novel sensing systems and for enhancing the performance of bioanalytical assays.
The discoveries of carbon nanomaterials (CNs), such as zero-dimensional (0D) fullerenes, one-dimensional (1D) carbon nanotubes (CNTs), two-dimensional (2D) graphene and three-dimensional (3D) nanodiamond substantially contributed to the fast development of nanoscience. Due to their unique properties (almost taking full advantage of nanomaterials), CNs have attracted considerable interests in many fields of research, including materials sciences, microelectronics, biomedicine and analytical electrochemistry [29]. A series of excellent properties of CNs such as chemical stability, high surface area, wide potential window, biocompatibility, enhanced electronic properties, and electrocatalytic activity for a variety of redox reactions make CNs appealing for sensing applications. In most cases, the CNs can increase the electrode area, enhance the electron transfer between the electrode and analytes, and/or act as catalysts to increase the efficiency of electrochemical reactions [34]. Therefore, CNs-based sensors generally have higher sensitivities, lower LOD, and faster electron transfer kinetics than traditional detection electrodes.
It is worth mentioning recent reviews that focus on different aspects of the application of various nanomaterials to analytical chemistry [30–33] and some reviews that focus CNs and their applications [34–37]. However, to the best of our knowledge, reviews on determination of BA with CNs are quite few up to now. Hence it is the aim of this article to summarize recent advances towards the use of CNs based electrochemical sensors for the detection of BA.
Carbon nanomaterials
Carbon is the earliest element discovered and used by human. Classical allotropes of carbon are known to be graphite, diamond, and amorphous carbon for a few thousand years. Several new allotropes of carbon (eg. nanodiamond, fullerenes, carbon nanofibers, CNTs, graphene and their derivatives) have been discovered in the past 30 years. These allotropes of carbon called as CNs, which have attracted considerable interests among nanostructured materials for their unique mechanical, thermal and electrical properties as well as for their biocompatibility [38]. Recently, CNs including CNTs, graphene, and their derivatives have been acknowledged to possess great potential to develop materials for a variety of applications such as adsorbent [34, 36], catalyst [39], batteries [35], capacitors [35], electrochemical sensors [37, 40], supports for biomacromolecules immobilization [41] and drug carrier [42] due to their unique properties (mainly displaying in their large surface areas and excellent mechanical and electronic properties).
The physical, chemical, and electronic properties of CNs are strongly coupled to carbon’s structural conformation and its hybridization state [43]. According to orbital hybridization theory, this promotion allows carbon to hybridize into a sp, sp2, or sp3 configuration based on bonding relationships. These mutable hybridization states account for the diversity among carbon’s bulk configuration (Fig. 1). The following contents of this sub-section focus on two kinds of CNs (CNTs and graphene). Their structures, basic properties, preparing methods and electrochemical applications are discussed briefly.
Carbon nanotubes
Since the discovery of CNTs in 1991 [44], researches on CNTs have progressed rapidly and become one of the most attractive part of nanotechnology. Generally, CNTs can be divided into two types (Fig. 2): single-walled CNTs (SWCNTs) which consist of a single tube of graphite and multi-walled CNTs (MWCNTs) which consist of several concentric tubes of graphite fitted one inside the other. SWCNTs are sp2 hybridized carbon in a hexagonal honeycomb structure that is rolled into hollow tube morphology. MWCNTs have a complex structure with each carbon layer having different chirality and electronic properties. The diameters of CNTs can range from just a few nanometers in the case of SWCNTs to several tens of nanometers for MWCNTs. The lengths of the tubes are usually in the micrometer range. Detailed information of the CNTs structures, dimensions and properties can be found in the many published articles [45–47].
CNTs are primarily synthesized by three main techniques: arcdischarge, laser ablation /vaporization, and chemical vapor deposition (CVD). Most commercially available CNTs are formed by CVD. Regardless of the method of synthesis, metal impurities remain the sample and affect the CNTs properties, even after some purification processes. The electrocatalytic behaviors of CNTs are unclear and somewhat controversial. Bank et al. [48, 49] think electrocatalysis of CNTs is attributed to edge-plane like sites, occurring at the nanotube open ends. However, subsequent researches pointed out that metal impurities arising from the CVD carbon nanotubes fabrication process might play an important role in the electrocatalytic property of CNTs [50–52].
Due to their large surface area, good conductive ability, excellent electrocatalytic ability, high surface activity and good biocompatibility, the CNTs have been widely used in sensing applications [53–56]. CNT-based sensors generally possess higher sensitivities, lower LODs, and faster electron transfer kinetics. Electrode performances depend on the synthesis method of the nanotubes, modification of CNTs surface, the method of electrode attachment, and the addition of electron mediators. Especially, the functionalization of CNTs surface, which can not only preserve their original properties but also bring in new properties, will broaden the applications of CNTs in electroanalysis. Generally, CNTs can be functionalized by covalent and non-covalent methods. Covalent functionalization of CNTs is to convert the CNTs sidewalls to nanotube-bound carboxylic acids upon oxidation and then functionalized with a range of groups such as amides, thiols, or others. The CNTs sidewalls functionalized noncovalently by, for example, aromatic compounds, surfactants, polymers, and DNA employing π-π stacking or hydrophobic interactions for the most part can also alter the electrochemical properties of the material. Some recent reviews have introduced the functionalization strategies and the research carried out using functionalized CNTs for electroanalytical and bioanalytical applications [57–59].
Graphene
Graphene has emerged as a rapidly rising star on the horizon of materials science and condensed-matter physics in recent years [60, 61]. It has attracted appreciable attentions to be used as a next generation CNs and shown great promise in many applications, such as electronics, energy storage and conversion, and bioscience /biotechnologies due to its exceptional physicochemical properties including high surface area, excellent thermal conductivity and electric conductivity, and strong mechanical strength [62].
Graphene is a 2D sheet of carbon atoms in a hexagonal configuration with atoms bonded by sp2 bonds. It is the thinnest known and the strongest ever measured material in the universe [63]. Graphene can be considered as a basic building block for CNs of all other dimensionality (Fig. 3). It can be stacked to form 3D graphite, rolled to form 1D nanotubes, and wrapped to form 0D fullerenes. Electrons can move freely in the crystal of graphene owing to the existences of π-orbits in the graphene plane, which makes graphene show superior electronic transmission performances [64]. On the other hand, every carbon atom is linked with adjacent carbon atom under the action of strong σ bonds and weak π bonds, which make graphene, possess excellent mechanical properties [65].
Up to now, several physical and chemical methods have been proposed to produce individual graphene or its derivatives, for example, mechanical exfoliation of bulk graphite, epitaxial growth on SiC, epitaxial growth by CVD of hydrocarbons on metal substrates, unzipping of CNTs, and chemical reduction of graphite oxide. Among these methods, mechanical exfoliation of highly oriented pyrolytic graphite remains to be the most popular and successful in producing single or few layers of graphene [64]. However, it is not suitable for mass production. Other methods, such as opitaxial growth on SiC and the metal-supported epitaxial growth of graphene via CVD, will be potential mass-production methods with the aim of producing graphene for electronics applications [66, 67]. Another mass-production method is chemical reduction of graphite oxide. Most of graphene used in electrochemistry applications are produced with this method. Graphene obtained from this method usually has abundant structural defects and functional groups which are advantageous for electrochemical applications [62].
In comparison with CNTs, graphene exhibits potential advantages of low cost and high purity (graphene does not contain metallic impurities as CNTs do) [68]. Some reviews summarize the electrochemical applications and advancements of graphene recently [69–71]. In particularly it is worth mentioning two reviews that focus on recent advances in graphene-based electrochemical sensors and biosensors [62, 68]. Generally, remarkable properties of graphene for electrochemical sensing and biosensing are mainly manifested in two aspects: (1) The specific electronic structure of graphene, which contributes to its high electrical conductivity and uniform electroactive site distribution and density [68], leads to excellent catalytic behaviors and increase of electrochemical responses toward small biomolecules; (2) Due to large surface area, biocompatibility and high conductivity, graphene is expected to immobilize enzymes and promote the electron transfer between electrode and enzymes. As a novel CNs, graphene and its derivatives have exhibited excellent electrochemical properties for the direct electrochemistry of enzymes [72, 73], electrochemical detection of biological small molecules [74, 75] and electrochemical sensor for heavy metal ions [76, 77].
CNs-based electrochemical sensors for biogenic amine neurotransmitters
During the long-term evolution of creatures on earth, kinds of neurotransmitters emerged. Neurotransmitters are endogenous chemicals that transmit signals from a neuron to a target cell across a synapse. In the brain, neurotransmitters are released into the cerebrospinal fluid via exocytosis and cleared by transporters or metabolism. Extracellular neurotransmitter concentrations can change rapidly and understanding the dynamics of neurotransmission is important for clinical research. There are many different ways to classify neurotransmitters. According to their chemical properties, neurotransmitters can be divided into amino acids, peptides, and biogenic amines (monoamines). Biogenic amine neurotransmitters, mainly inculding dopamine (DA), epinephrine (EP), norepinephrine (NE), serotonin (5-hydroxytryptamine, 5-HT) (Fig. 4), are compounds of great biomedical interest, playing significant roles in the functioning of the human metabolism, central nervous. DA is well known as one of the important neurotransmitters, which is released from brain neurons to extracellular fluids and plays a significant role in the central nervous, renal, hormonal, and cardiovascular systems [78]. Extreme abnormalities in DA levels are symptoms of several disease states such as schizophrenia, parkinson’s and alzheimer’s diseases [79, 80]. 5-HT is a monoamine neurotransmitter of enormous biological importance widely distributed in the central nervous system, which plays an important role in a number of fundamental biological processes, including a variety of physiological functions (sleep regulation) and pathological states (psychiatric disorders, depression, mental retardation, infantileautism, etc.) [81]. EP known as the “fight or flight” hormone, energizes and speeds up the various systems within the body and plays an important role during the times of physical or mental stress [82]. Medically, EP has been used as a common emergency healthcare medicine. Studies show that extreme abnormalities of EP levels in nervous tissues and body fluids are symptoms of several diseases. The quantitative determination of EP concentration is quite helpful for developing nerve physiology, clinical diagnosis of some diseases and controlling medicine in pharmacological research [83]. NE is one of the derivatives of cathecholamines secreted in the adrenal medulla and plays important physiological roles in the central nervous system. It increases the conversion of glycogen to glucose in the liver, helps in converting fats into fatty acids, and relaxing the bronchial muscles [84]. It is also critical in mental disease, heart failure, DNA breaks in cardiac myoblast cells, and diabetes that both catecholamines have complementary actions in human body [85].
As their impacts on human health and diagnosis of some diseases, it is worthwhile to develop a quantitative method for studying concentration of biogenic amine neurotransmitters. Because of the simple procedure and high sensitivity of electroanalysis and the electroactivity of biogenic amine neurotransmitters, studying and measuring of these compounds with electrochemical methods were carried out. CNs are widely used as sensing platform for biogenic amine neurotransmitters due to their unique physical and chemical properties. Adding CNs to electrodes for neurotransmitter sensing might facilitate higher sensitivity and improve the electron transfer kinetics. Most CNs based electrochemical sensors for neurotransmitters do not incorporate a specific molecular recognition element, but the electrochemical techniques offer some selectivity and chemical identification of the species being detected. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) are the most common electrochemical techniques employed. The DPV method is usually used in studies to discriminate multiple compounds and improve sensitivity because it produces less background current, leading to low LODs. Electrochemical sensors for the detection of biogenic amines neurotransmitters are mainly based on the modification of CNTs and graphene onto the electrodes, which are summarized in Tables 1 and 2, respectively.
Dopamine
Electrochemical methods have proven to be rapid, simple and sensitive in the determination of neurotransmitters. However, at traditional solid electrodes, DA and its coexisting species ascorbic acid (AA) and uric acid (UA) have an overlapping voltammetric responses, resulting in rather poor selectivity and sensitivity for the detect of DA. Thus, it is a challenge to separate the oxidation peaks of AA, DA and UA from each other in electrochemical analysis.
Nanodiamond, carbon nanofibers and fullerene modified electrodes for dopamine analysis
An electrode for biosensing applications should have several material properties such as a wide working potential window, a low and stable background current, high resistance to deactivation due to surface adsorption, biocompatibility, good sensitivity and selectivity for detection of target analytes and a fast response time. Nanodiamond and fullerene have emerged as important materials which meet most of these criteria. Until now, there are only few reports about these materials modified electrodes being applied as sensors for DA. Raina et al. [86] reported a ultra-microelectrode array (UMEA) fabricated with nitrogen-incorporated nanodiamond. The nanodiamond UMEA was fabricated using conventional silicon microfabrication processes and plasma enhanced CVD nanodiamond growth. Without any surface functionalization of the nanodiamond surface, the sensor shows a steady state response and a linear relationship between the limiting current and DA concentration. Breczko et al. reported a carbon nano onion (CNO) and poly (diallyldimethyl- ammoniumchloride) (PDDA) composite modified glass carbon electrode (GCE) to detect DA for the first time [87]. The resulting CNO/PDDA composites film possessed faster adsorption dynamics and higher selectivity for DA than the non-modified GCE. The DPV method exhibits a lower LOD for DA and a sensitivity equal to 0.1 μM and 0.0175 μA (μM)−1, respectively. A gold electrode modified with partially reduced fullerene-C60 was developed by Goyal et al. [88]. The modified electrode not only showed strong electrocatalytic activity toward the oxidation of DA and AA, but also resolved the overlapped anodic peak of the analytes into two distinct peaks, and thus DA can be detected selectively in the presence of excess of AA. In their study by square wave voltammetry (SWV), the electrode exhibited substantially enhanced electrochemical signals for DA sensing with linear range of 1 nM–5.0 μM and low LOD of 0.26 nM. The C60/Au electrode was further applied to the determination of DA in DA hydrochloride injection and human blood serum and urine samples with satisfactory results. Carbon fiber microelectrodes (CFMEs) are commonly employed to quantify rapid DA fluctuations both in vitro and in vivo. These electrodes have proven to be particularly useful in biological applications because of their biocompatibility, high tensile strength, low cost, wide potential window, and inert nature [89]. Ates et al. [90] reported a CFME modified with polycarbazole and poly (carbazole-co-p-tolylsulfonyl pyrrole) films by electrochemical deposition technique. This sensor displayed significantly increased currents for the detection of DA in comparison an uncoated CFME, which is attributed to the significant increasing of surface area after polymer modification. Njagi et al. [91] developed a novel implantable enzyme-based carbon fiber biosensor for in vivo monitoring of DA. The biosensor is fabricated by immobilizing tyrosinase in a biocompatible matrix consisting of a biopolymer, chitosan (CS) and ceria-based metal oxides, deposited onto the surface of a CFME with a diameter of 100 μm. This biosensor demonstrated a LOD of 1 nM DA, a linear range of 5 orders of magnitude between 10 nM and 220 μM, a sensitivity of 14.2 nA μM−1, and good selectivity against AA, UA, 5-HT, NE, EP, and 3,4-dihydroxy-L-phenylalanine. Importantly, the biosensor provides an alternative to fast scan CV for in vivo monitoring of DA release in the brain of an anesthetized rat. A carbon nanofiber electrode (CNFE) array integrated with the wireless instantaneous neurotransmitter concentration sensor system (WINCS) was used for electrochemical detection of DA by fast scan CV [92]. Compared to the traditional CFME for the detection of DA, the novel CNFE array is expected to facilitate the detection of neurochemical release over a large area of interrogation, yet with high spatial resolution.
Carbon nanotubes modified electrodes for dopamine analysis
Significant developments have taken place in the field of CNTs based electrochemical sensors for the detection of neurotransmitters. Recently, electrodes modified with CNTs and their composites for the detection of DA were categorized into four types: CNT paste electrodes, CNTs directly deposited or grown on electrodes, polymer coatings on electrodes, functionalized nanotubes modified electrodes.
The first paper that demonstrated the use of CNTs for the detection of DA was published by Britto et al. [93] in 1996. The CNT modified paste electrode increased sensitivity for the determination of DA and showed nearly ideal, reversible kinetics, which is unusual for DA at carbon electrodes. This study paved a way for the use of CNTs in neurotransmitter sensing. Then Zhao et al. [94] reported a carbon nanotubes-ionic liquid (CNTs-IL) gel modified electrode for DA detection. The anodic peaks of DA, UA and AA were well-distinguished and DA can be detected selectively. Shahrokhian et al. [95] reported a modified carbon paste electrode (CPE) which was prepared by incorporating thionine-nafion supported on MWCNTs. The modified CPE possessed an efficient electrocatalytic activity for the electrochemical oxidation of DA and AA and the peak potential separation of nearly 393 mV is achieved for two compounds. Beitollahi et al. [96] utilized a 2,2′-[1,2-ethanediylbis (nitriloethylidyne)]-bis-hydroquinone (EBNBH) modified CNT paste electrode to determine DA and UA. The electrocatalytic currents increased linearly with the DA and UA concentrations in the ranges of 0.1–900 μM and 20–650 μM, and the LODs for DA and UA were 0.087 μM and 15 μM, respectively. Sathisha et al. [97] reported a hydroxy double salt (HDS)/sodiumdodecyl sulfate (SDS) film modified CPE, which was developed for the sensitive and selective determination of DA in the presence of large excess of AA and UA. The LOD for DA was 0.1 μM.
CNTs can be functionalized with strong acid and then deposited on electrodes using layer-by-layer (LBL) technique. Also CNTs can be grown on different substrates and then used directly as electrodes. For example, Mao et al. [98] prepared a homogeneously and stably assembled CNT multilayer film modified GCE using LBL method based on electrostatic interaction between the positively charged PDDA and negatively charged shortened CNTs and studied electrochemical catalytic activity of the assembled MWCNTs toward DA in the presence of AA. Zhang et al. assembled functionalized SWCNT multilayer films on GCE by alternately assembling positively charged cetylpyridinium bromide (CPB) and negatively charged SWCNTs based on electrostatic interaction [99]. The DA, AA and UA can be well-separation on multilayer film modified electrode on CVs. The multi-layer films show remarkable selectivity and high sensitivity for DA and UA, which eliminate interference from high concentrations of AA. The LODs for DA and UA were 0.6 μM and 7.0 μM, repectively. Manjunatha et al. [100] used LBL technique to form multilayer films consisting of PDDA and MWCNTs wrapped with polystyrene sulfonate (PSS). The sensor was applied for the simultaneous detect of DA, AA and UA with the LODs of 0.5 μM, 0.15 μM and 0.8 μM, respectively. Zheng et al. [101] grew MWCNT on a Ta substrate and then functionalized them with SDS to detect DA in the presence of AA. In their DPV studies, they obtained a LOD of 3.75 μM for DA in the presence of AA ranging from 0.02 μM to 0.2 mM. Macpherson’s group has grown ultrathin CNT mat microelectrodes on insulating Si surfaces by CVD [102]. The CNT networks retained a low capacitance and background signal and exhibited less retardation of electron transfer for multiple scans for DA. However, the peak potentials of DA also shifted to higher potentials than GCE and the reduction peak was diminished.
Another popular strategy for DA detection with CNT sensors is to immobilize CNTs onto electrodes using polymer coatings. Among various types of conducting polymers, polypyrrole (PPY) and polyaniline (PANI) have been the focus of several recent studies because their high conductivity and good environmental stability. For example, a GCE modified with both PANI film and MWCNTs with incorporated β-cyclodextrin (β-CD) was developed by Yin and co-workers [103]. The modified electrode exhibits substantially electrochemical responses toward DA oxidation with a wide linear range (0.1–1,000 μM) and a low LOD of 12 nM (S/N = 3). PPY can be overoxidized to create an electrically insulating layer. Overoxidized polypyrrole (OPPY) films are permeable to cations, like DA, but the films repel anions and neutral compounds, such as AA and 5-HT. Tu et al. modified a gold electrode with the OPPY–MWCNTs nanocomposite using electropolymerization method [104]. The properties of the modified films were studied by the electrochemical quartz crystal impedance method in neutral and alkaline solutions. The modification of the overoxidized nanocomposite film improved substantially the sensitivity for DA assay in a neutral phosphate buffer, as compared with the modification of OPPY or MWCNTs alone. In their DPV studies, they obtained a linear range from 0.04 μM to 1.4 μM and a limit of detection of 1.7 nM. Lin et al. fabricated a microsensor by electrochemically depositing a film containing OPPY and MWCNTs onto a CFME [105]. The modified electrode showed efficient and selective electrocatalytic oxidation of DA and displayed relatively good stability and lifetime. The oxidation currents for DA are linear in the concentration range from 5.0 nM to 10 μM, and the LOD (S/N = 3) is 0.5 nM. Besides, the sensor was successfully applied to in-vivo determination of DA in rat striatum of freely moving rats. This paper was proof of concept but more work would be needed to miniaturize the microelectrodes for in vivo applications. Several studies were performed for the detection of DA, UA, and AA simultaneously. Two distinct linear sweep voltammetry (LSV) peaks for DA and UA were observed at a GCE modified with poly (acrylic acid) functionalized MWCNTs [106]. The LODs for UA and DA were 20 nM and 100 nM, respectively. A redox polymer–CNT composite film modified GCE was fabricated by electropolymerization of acid yellow 9(AY)/MWCNTs films in 0.1 M H2SO4 solution [107]. The newly synthesized PAY –MWCNTs composite film showed excellent electrocatalytic activity towards oxidation of DA and AA with high sensitivity in physiological pH. LODs were 0.1 μM and 0.2 μM for DA and AA, respectively. Zhang et al. [108] reported a modified GCE with poly (orthanilic acid) coated MWCNTs composite was applied for the simultaneous detect of DA and UA in the presence of AA. The LODs for UA and DA were 0.44 μM and 0.21 μM, respectively. A novel bio-composite film containing MWCNTs-CS/poly (amidoamine) nanocomposite along with the incorporation of DNA was used to fabricated a biosensor for determination of DA and UA under coexistence of AA [109]. The sensor exhibited strong catalytic activity toward the oxidation of DA and UA and separated the originally overlapped signals of UA, DA and AA oxidation. In the presence of 1.0 mM AA, LODs for DA and UA were 0.03 μM and 0.07 μM, respectively.
Several polymer-based methods are approaching basal DA levels, 10 nM, in sensitivity. For example, Zhang developed a PSS/SWCNTs composite by dispersing SWCNTs into PSS chloroform solution and then coated it on GCE [110]. The interference was eliminated due to the interaction between DA cations and the negative PSS film in pH 7.0 PBS solutions. The DPV method exhibited a high sensitivity and a very low LOD of 5.0 nM for DA detection. Wang et al. prepared the hybrid film modified GCE by coating the Nafion/SWCNTs onto the electrochemical poly (3-methylthiophene) (P3MT) surface [111]. This modified electrode combined the advantages of P3MT, CNTs and Nafion, which exhibited dramatic electrocatalytic effect on the electrooxidation of DA. The Nafion discriminates AA and UA, while the P3MT polymer and CNTs shows excellent electrocatalytic effects for DA. The LOD was 5.0 nM, less than basal DA levels. Then the modified electrode was successfully applied to the determination of DA contents in human serum with satisfactory results. Several novel sensor combining molecularly imprinted polymers (MIPs) and CNTs has also been develop. Kan et al. developed a sensor with MWCNTs s and MIPs modified GCE [112]. By using a MIPs specifically for DA, the sensor showed both rapid adsorption and selectivity over DA and AA. Because the method required incubation in DA, it was not particularly fast but concentrations low to 0.1 μM were measured. CNTs modified screen-printed electrode was fabricated by Moreno et al. [113]. The sensor shows high sensitivity and selectivity for DA detection with coexistence of AA . The LOD for DA was 15 nM. In short, polymer coated CNT electrodes show good LODs and are promising for detecting low quantities of neurotransmitters. The downside of adding a polymer is that it restricts diffusion and slows the temporal resolution.
Studies combining metal or metallic compounds and CNTs to enhance sensitivity and selectivity for DA have been performed using metal nanoparticles functionalized CNTs-modified electrode or metallic oxide (metal hydroxides) nanoparticles functionalized CNTs-modified electrodes. Dursun et al. fabricated a modified electrode by electrochemically deposition of Pt nanoparticles (PtNPs) on the MWCNTs covered GC electrode [114]. The enhanced peak current and well-defined peak separations toward electrocatalytic oxidation of DA, UA and AA on the modified electrode was obtained compared with both bare and MWCNTs/GCE. In their studies of simultaneous determination by DPV, LODs were calculated for AA, DA, and UA, as of 20 μM, 48.3 nM, and 0.35 μM, respectively. Adekunle et al. modified edge-plane pyrolytic graphite electrode (EPPGE) with SWCNTs–iron (III) oxide (SWCNT/Fe2O3) nanoparticles by electrochemical deposition [115]. Compared with the bare electrode or electrodes without the Fe2O3 nanoparticles, the EPPGE-SWCNT–Fe2O3 gave best response (7 times more than bare EPPGE and 2-fold more than EPPGE-SWCNT and EPPGE-SWCNT–Fe) towards the detection of DA. The sensitivity and LOD for DA detection were 3.44 μA μM−1 and 0.36 μM, respectively. Jia et al. develop nanoparticles and MWCNTs modified electrode [116], where gold nanoparticles–poly (luminol) hybrid film (AuNPs-Plu) was coated on the surface of a GCE by electrodeposition method and MWCNTs incorporated β-CD was dropped onto the surfaces of Plu-AuNPs/GCE. The porous structure of Plu film allows the AuNPs dispersing into the polymer matrix and generates additional electrocatalytic sites. β-CD is used as a dispersing reagent for CNTs and CNTs increased the sensitivity for oxidation of DA, with an electrocatalytic effect as well. Zhang et al. prepared a novel material, sol–gel drived La(OH)3 nanorods and designed it to incorporate with CNTs to modify GCE and then applied to simultaneously voltammetric determine AA,DA,UA and NO2 − [117]. The modified electrode shows high selectivity and well stability. More importance, this material can be extended to construct other electrochemical sensors by the immobilization of enzymes and antibodies. Lin et al. prepared a polydopamine (PDOP) and PtNPs coated MWCNTs and developed a sensor for simultaneous determination of DA and UA [118]. The sensor shows remarkable sensitivity, reproducibility and stability to the electrocatalysis of DA and UA, with LODs of 0.08 μM and 0.12 μM, respectively. In recent studies, boron-doped CNTs (BCNTs) or boronic acid functionalized CNTs have been used for constructing sensing platform to enhance sensitivity and selectivity of DA. It has been reported that the physicochemical properties of CNTs could be tailored by doping CNTs with B atom and the electronic, mechanic, conductive properties of CNTs could be improved obviously [119, 120]. BCNTs have been used for determination of DA because of more edge plane sites on the surface of CNTs and more functional groups at the defective sites of BCNTs. A modified GCE with BCNTs was used to discriminate DA and AA and a LOD of 1.4 nM was obtained for DA [121]. This LOD is among the lowest reported for a CNT-based sensor for DA with the only disadvantage being that the BCNTs are not widely available. In a study by Wu et al., GCEs were modified with boronic acid functionalized MWCNTs for the indirect detection of DA [122]. Indirect detection was used, based on selective binding of the cis-diol group of DA with boronic acid to form a boronate ester, which is oxidized at a more positive potential than DA. The modified electrode exhibited a LOD below 0.5 μM, not as good as direct detection. Ali et al. report a nonoxidative sensor to indirect detect DA with high sensitivity and selectivity [123]. This sensor was fabricated with a thin layer of in situ polymerized poly (anilineboronic acid) (PABA)/CNT composite and a thin layer of the highly permselective Nafion film. PABA also binds with DA to form a boronate ester and complex formation greatly affects the conductivity of the PANI backbone. Therefore, the amount of binding is directly proportional to the amperometric signal. The sensor exhibited a linear range from 1 nM to 10 nM and a low LOD (0.6 nM), indicating it might allow for its potential use in the diagnosis of Parkinson’s disease.
Different methods CNT-based sensors for have been developed for the DA detection. Overall, CNT paste electrodes are simple-preparing and low cost. Problems with such electrodes may be their miniaturization for DA analysis in vivo. Electrodes grown directly with CNTs may end up being the easiest to fabricate reproducibly in large quantities which could lead to more widespread implementation. Polymer coated methods are used to improve sensitivity by binding of CNTs with some conducting polymers and/or selectivity by screening out interferents such as AA. CNTs functionalized with metal/metallic oxide nanoparticles have emerged as a popular strategy to fabricate electrochemical sensors for DA detection. Electrodes incorporation of metal nanoparticles and CNTs can facilitate heterogeneous electron transfer and increase analytical sensitivity. Boron/boronic acid functionalized CNT studies show high sensitivity for DA, however, practical biologically relevant experiments are necessary. Future studies may focus on the improvement of sensitivity and selectivity of CNTs modified electrodes and applications of these sensors in biological samples.
Graphene modified electrodes for dopamine analysis
Graphene, a flat monolayer of carbon atoms closely packed into a honeycomb 2D lattice, has attracted tremendous attention from scientific communities in recent years. Comparing to the commonly used CNTs, graphene has higher surface area, more excellent electrical conductivity and electron mobility at room temperature due to their unique 2D nanostructure. The special properties of graphene may provide insight to fabricate novel sensors for virtual applications. Recently, graphene exhibited a significant potential for the electrochemical sensors applications. Graphene based electrochemical sensors have displayed favorable electrochemical catalytic activities towards DA, most of which were fabricated by casting the multilayer films of graphene nanosheets or their based hybrids directly onto the electrode surface. Shang et al. [78] reported an electrochemical method on selective detection of DA by using multilayer graphene nanoflake films which were fabricated via CVD. Geim et al. [124], Tan et al. [125], and Kim et al. [126] reported electrochemical sensors for selective detection of DA by using graphene, which was synthesized by chemical reduction of graphite oxide. In their studies, graphene was dispersed in CS, β-CD or DMF to form a stable suspension and sensors were obtained by modifying GCE with microliters of the suspension via drop-casting method. A polyvinylpyrrolidone (PVP)/graphene modified GCE was prepared and applied for the fabrication of DA sensors without the interference of AA by Liu and coworkers [127]. Graphene was synthesized through electrochemical reduction of graphene oxide (GO) and characterized by spectroscopic and electrochemical techniques. Amperometric response results showed that the PVP/graphene based sensor displayed a wide linear range of 0.5 nM-1.13 mM and a LOD of 0.2 nM. Han et al. [128] reported a CS functionalized graphene based electrode, which was synthesized by a together-blending and in situ chemical reduction method. The electrode exhibited well resolved simultaneous discrimination of AA, DA, and UA, and the LODs were 1 μM, 50 μM and 2 μM, respectively. Hou et al. [129] synthesized EDTA-modified reduced graphene (EDTA-RG) by silanization of graphene with N-(trimethoxysilylpropyl) ethylenediamine triacetic acid (EDTA-silane). The EDTA-RG dispersed in Nafion/ethanol solution was used to construct a DA biosensor. The sensor exhibits highly sensitive and selective electrocatalysis toward DA in the presence of AA. They attributed it to carboxylic groups on the edges of graphene produced by the chemical modification process and Nafion, the ionic selectivity film. Sheng et al. [130] developed an electrochemical sensor based on nitrogen doped graphene (NG), which was prepared by thermally annealing graphite oxide and melamine mixture. The electrochemical sensor shows a wide linear response for AA, DA and UA in the concentration range of 5 to 1,300 μM, 0.5 to 170 μM and 0.1 to 20 μM with LODs of 2.2 μM, 0.25 μM and 0.45 nM. The superior sensing performance is mainly due to the interactions between nitrogen atoms in NG layers with these molecules via hydrogen bond and the π-π interactions between graphene layers and these molecules. A new type of porphyrin-functionalized graphene was synthesized and used for highly selective and sensitive detection of DA by Wu and coworkers [131]. In their studies by DPV, the oxidation peak currents of DA in the presence of AA and UA is increased linearly with the concentrations of DA in the range of 100–1,000 nM and the LOD was 22 nM. They attributed it to the aromatic π-π stacking and electrostatic attraction between positively-charged DA and negatively-charged porphyrin-modified graphene which can accelerate the electron transfer whereas weakening AA and UA oxidation.
Some groups reported metal or metallic oxide nanoparticles/graphene nanocomposite for DA sensing. A water-soluble and electroactive composite–PtNPs/polyelectrolyte-functionalized ionic liquid (PFIL)/graphene sheets (GS) nanocomposite was synthesized by Li et al. [132]. The nanocomposite can distinguish AA from DA at two independent peaks with the potentials separation of 200 mV by CV, indicating it can realize simultaneous determination of DA and AA. Zhang et al. [133] reported a nanocomposite composed of cuprous oxide (Cu2O) and graphene which were synthesized via reduction of copper (II) in ethylene glycol. GCE was modified with this nanocomposite for the detection of DA. The LOD was 10 nM. A modified GCE with graphene/AuNPs multilayer films was used to detect DA [134]. The modified electrode was fabricated by the electrostatic LBL self-assembly technique between polysodium 4-styrenesulfonate functionalized reduced graphene oxide (rGO) and polyamidoamine (PAMAM) dendrimer stabilized AuNPs. The electrode exhibited a improved electrocatalytic activity towards the oxidation of DA due to the synergistic effect of AuNPs and rGO. Li et al. [135] reported a simple, green and controllable approach for electrochemical synthesis of a nanocomposite made up from electrochemically rGO and AuNPs. The nanocomposite showed an excellent electrocatalytic activity toward DA, with a LOD of 0.04 μM (at S/N = 3). A novel sensor combining MIPs and graphene/Congo red (GSCR) has also been developed (Fig. 5) [136]. Fig. 6 shows the synthesis route of GSCR-MIPs hybrids. The template molecules (DA) were firstly absorbed at the GSCR surface and then selective copolymerization of methacrylic acid (MAA) and ethylene glycol dimethacrylate (EGDMA) was further achieved at the GSCR surface. By using MIPs specifically for DA, the sensor showed both rapid adsorption and selectivity over DA. Graphene-CS composite, as the functional matrix, has been attempted for detection of DA [137]. The MIPs-graphene sensor was prepared through electrodepositing DA-graphene-CS composited film on the GCE and then removing DA from the film via electrochemical induced elution. The sensor exhibited a low LOD of 0.01 nM. Ping et al. [138] developed a high-performance screen-printed graphene electrode for the simultaneous determination of DA, AA and UA, with LODs of 0.12 μM, 0.95 μM and 0.20 μM, respectively. This work firstly introduced a sensitive and selective electrochemical sensing device by using the disposable graphene electrode made from graphene-based ink, holding great promise for its wide application in the clinical diagnosis and pharmaceutical analysis. Liu et al. reported a novel label-free electrochemical aptasensor based graphene-polyaniline (GR–PANI) nanocomposite film for DA determination [139]. The GR-PANI nanocomposites were synthesized by in situ polymerization method. The aptamer was directly immobilized on the GR–PANI nanocomposites films modified electrode as a DA capture. The electrochemical aptasensor showed a linear response to DA in the range 0.007–90 nM and a ultra lower LOD of 1.98 pM. An electrochemical sensor for determination of DA based on 3,4,9,10-perylene tetracarboxylic acid functionalized GS, MWCNTs and IL composite was fabricated by Niu et al. [140]. This sensors exhibited excellent sensitivity to DA in the presented of high concentration of AA.
Serotonin
Research shows that DA and 5-HT influence each other in their respective releasing. Thus, simultaneous determination of DA and 5-HT is important because of their co-existence in biological systems. Both DA and 5-HT are readily oxidized; hence, electrochemical techniques have been explored for their analysis. However, a major obstacle encountered in the simultaneous determination of DA and 5-HT is the co-existence of high concentration of AA and UA in vivo, which can be oxidized at potential close to that of DA and 5-HT at conventional electrodes, resulting in an overlapping voltammetric response. A great deal of efforts has been directed towards overcoming these difficulties for the determination of DA and 5-HT by using chemically modified electrodes. Ionic liquids (ILs), which are comprised entirely of ions and exist in liquid state at ambient temperatures around 298 K and below, have good solvating properties, high conductivity, non-volatility, low toxicity, large potential window and good electrochemical stability. CNTs modified electrodes made by using ILs as a binder for analytical purposes give new capabilities to electrochemical sensors by combining the advantages of both ionic liquids and CNTs. Fukushima et al. firstly reported a thermally stable, highly conductive physical gel, which was formed with imidazolium ions and SWCNTs [141]. Subsequently several reports that simultaneously detects DA and 5-HT by using CNT-ILs gel electrodes have been developed. We also developed a MWCNT-IL composite modified GCE for the simultaneous determination of 5-HT and DA [81]. The CNTs-IL composite modified electrode presents excellent selectivity and sensitivity towards 5-HT and DA and eliminates the interference of AA. As shown in the differential pulse voltammograms in Fig. 6, the DPV current signal for DA (or 5-HT) in the presence of 5-HT (or DA) and a large excess of AA is well-distinguished. Good linearity was obtained between the anodic differential pulse voltammograms peak currents of DA (or 5-HT) and their concentrations in the mixture. Moreover, it is found that AA and other endogenous substrates such as glucose, NaCl, UA, purine, L-histidine and L-cysteine do not provoke any signal response. Recently, graphene has emerged as a promising candidate material for generating novel electrochemical sensors for simple, fast, and sensitive voltammetric determination of 5-HT. Kim et al. [142] developed sensors for detection of 5-HT based on various graphene nanomaterials. Results obtained in this paper show that graphene reduced by hydrazine and ammonia solution had the lowest LOD, highest sensitivity, best selectivity, widest linear range, fastest response time, and best defined peak of 5-HT.
Another method that simultaneously detects DA and 5-HT are CFMEs. Swamy et al. [143] performed an in vivo study by using CFMEs coated with SWCNTs suspended in Nafion and DA and 5-HT were simultaneously detected by using fast-scan cyclic voltammetry. They found that the signals for DA and 5-HT increased two fold and the reduction peaks were separated by 200 mV. This study also showed that the SWCNT-modified CFME was useful for measurement of changes of DA and 5-HT in anesthetized rats. A CFMEs modified with CNTs dispersed in nafion for the detection of 5-HT was developed by Njagi et al. [144]. The electrode showed a LOD of 1 nM, a linear range between 5 and 200 nM, and a sensitivity of 83.65 nA μM−1. Importantly, it is the first application of electrochemical microsensors for in vivo monitoring of intestinal 5-HT levels in intact zebrafish embryos.
Epinephrine and norepinephrine
EP is electrochemically active, so it can be detected by electrochemical methods. However, it is difficult to distinguish its response signal on unmodified electrodes, such as GCE, because of the overlapping of oxidation potentials of AA, EP, and UA that often cause a pronounced fouling effect resulting in rather poor selectivity and reproducibility. Numerous attempts were made for the simultaneous determination EP in presence of UA or AA, such as using chemically modified electrodes (CMEs). Shahrokhian et al. [145] modified pyrolytic graphite electrode with nano-diamond /graphite film. EP and UA were simultaneous detected and AA was not interfered. Wide linear ranges of 0.01–10 μM and 0.01–60 μM for EP and UA were obtained, respectively. The LODs for both compounds were 3 nM. The human blood serum, urine and the corresponding injecting samples were determined with very good reproducibility, repeatability and sensitivity. A nanocomposite modified electrode composed of MWCNT-nafion-AuNPs-PtNPs was used to detect AA, EP and UA simultaneously [146]. A stainless steel wire coated with SWCNT by electrodeposition was used to detect EP by Valentini et al. [147]. This electrode is smaller than most wire electrode, often 300 μm in diameter. But the 2 μM of LOD are high for physiological studies. Beitollahi et al. have studied a CNTs paste electrodes for EP detection [148]. The CNTs paste electrode was modified with EBNBH and had LODs of 0.22 μM, 8.8 μM and 11.0 μM for EP, UA and folic acid, respectively. A sensor employs the in situ electropolymerization of brilliant cresyl blue (BCB) with MWCNTs onto GCE was applied for the detection of EP [149]. In situ electropolymerization presented several advantages such as reducing usage of modifier and producing a uniform composite, which allows for high signal-to-noise ratio and sensitivity. A very low LOD of 10 nM was observed for EP using LSV. Moraes et al. [150] developed a CNTs-composite electrode for selective determination of EP. The electrode was prepared by mixed paraffin, CNTs and cobalt phthalocyanine (CoPc). EP was detected by DPV method without any previous step of extraction, clean-up, and derivatization and the linear range of EP was from 1.33 μM to 5.50 μM with a LOD of 15.6 nM. Human urine samples without any purification step were successfully analyzed under the standard addition method using this modified electrode. A composite film, constructed of surfactant doped over-oxidized PPY and MWCNTs was modified on GCE by electropolymerization method [151]. The electrode shows a high sensitivity and selectivity toward the electrocatalysis of EP coexistence of AA, UA and human serum interferences, which makes it a sensor suitable for the analysis of trace amounts of EP in pharmaceutical and clinical preparation. A EPPGE modified with MWCNTs was used as a sensor for the detection of EP [83]. A very low LOD of 0.15 nM was obtained for EP using SWV. The modified electrode was successfully applied to determine EP in body fluids of smokers and nonsmokers in resting stage.
Recently there are only few reports related to electrochemical sensors based on graphene and its derivatives for the detection of EP. Li et al. [152] fabricated a graphene-modified GCE via a drop-casting method for selective determination of EP in the presence of AA. A nano-Au decorated graphene nanocomposites was prepared via a chemical co-reduction of Au (III) and GO and used to fabricate an electrochemical sensor for EP [153]. In this paper, the co-reduction graphene/AuNPs were prepared by the reduction of a mixture of Au (III) and GO with sodium citrate. Finally, the reduction of GO and the in situ deposition of nano-Au were achieved in a one-pot process. The AuNPs, which were dispersed uniformly on the GS, acted as spacers for inhibiting the aggregation of graphene. The modified electrode exhibited high sensitivity and selectivity in the detection of EP. The LOD for EP was 7 nM and AA was not interfered.
EP and NE are difficult to distinguish using common electrochemical methods owing to their structural and chemical similarity. Nevertheless, it is feasible to fabricate selective sensors for EP and NE using CNT-based electrodes. A CNT paste electrode fabricated with a quinazoline derivative,2-(4-oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl-hydrazincarbothio-amide (2PHC), could detect EP and NE simultaneously [85]. Separate EP and NE peaks (about 240 mV) were observed with SWV (Fig. 7) and the LOD was 9.6 nM for EP. This level is approximately that of basal EP in the brain. Another sensor for the simultaneous determination of EP and NE is based on a MWCNT-poly (nordihydroguaiaretic acid) (PNDGA)-CS copolymer film on gold electrodes or screen-printed carbon electrodes [154]. MWCNTs enhance PNDGA-CS’s surface coverage concentration on the electrode and decreases degradation of PNDGA-CS during cycling. EP and NE were not discriminated and the lowest concentrations studied were 30 μM and 780 μM, respectively. An EPPGE modified with MWCNTs was used as a sensor for the detection of EP and NE [84]. Very low LODs of 0.15 nM and 0.09 nM were obtained for EP and NE using SWV, respectively. The modified electrode was successfully applied to determine EP and NE in blood plasma and urine samples of smokers as well as in athletes.
In general, CNTs, graphene and their derivatives have been widely used as promising nanomaterials for the development of advanced sensors for neurotransmitters owing to their unique structures and properties to decrease overpotential and improve sensitivity. However, only a few studies have used these sensors in a biological system in vivo or in vitro. For more applied work, efforts would need to be taken on reducing the size of the electrodes, as many are based on large-sized electrodes such as GCE, which are not suitable for real time analysis of neurotransmitters. CFMEs may be one of the candicate electrodes. Future research work can be focused on CNTs or graphene modified CFMEs for in vivo monitoring of neurotransmitters in tissues and brain cells. Additionally, DPV method is relatively slow and true measurements of neurotransmitter changes will require subsecond temporal resolution, so methods such as fast-scan cyclic voltammetry and amperometry may become more popular for making real measurements.
Carbon nanomaterials based electrochemical sensors for biogenic amines in food
BA are organic substances present in foods such as fish, meat, vegetables, fruits, nuts, chocolate, wine and beer. Excessive intake of BA may induce toxicological risks and health troubles. For example, the most frequent foodborne intoxications caused by BA involve histamine. An intake of 5–10 mg of histamine can be considered as defecting to some sensitive people, 10 mg is considered as tolerable limit, 100 mg induce a medium toxicity and 1,000 mg is highly toxic. Therefore, BA in food is commonly used as an indicator for assessing its freshness and quality. Accordingly, there is considerable interest in the determination of BA in foods. The application of electrochemical sensors and biosensors for BA analysis is a good alternative to traditional chromatographic methods due to their low cost, short analysis time, simplicity and possibility to be used outside an organized laboratory.
Tyramine
Tyramine, or 4-hydroxyphenethylamine, produced by the decarboxylation of tyrosine, is one of the BA, which are produced as degradation products resulting from microbial activity. Tyramine is found in high amount in certain foods such as chocolates, wine, beer, cheese, beans, banana peel, ketchup’s and soya products. It has been reported that tyramine containing foods can cause unnatural and toxic effects when ingested in large quantities. For these reasons, the development of a fast, accurate method to measure tyramine concentrations in foods would be valuable. Electrochemical method may be a better option because of their simplicity, rapidity and high sensitivity. Because tyramine is known to polymerize and passivate electrode surfaces, detection for tyramine at conventional electrodes is limited. The reported electrochemical biosensors/sensors for tyramine determination have been developed by enzyme-based electrodes or chemically modified electrodes without enzyme.
Cooper et al. [155] developed an electrochemical method to detect fast changes in tyramine and octopamine. They fabricated CFMEs and applied them for the determination of objectives using fast-scan cyclic voltammetry. No fouling was observed for tyramine and octopamine. LODs of 18 nM for tyramine and 30 nM for octopamine were obtained, which were much lower than expected levels in insects and lower than basal levels in some brain regions of mammals. This study showed that the method was useful for measuring tyramine and octopamine changes in insects. A novel sensor combining MIPs, MWCNT-AuNPs composites and CS has been developed [156]. By using MWCNT-AuNPs composites introduced for the enhancement of electronic transmission and a MIP specifically for tyramine, the sensor showed excellent selectivity and sensitivity over tyramine. The linear range using amperometric measurement was 0.108 μM to 10 μM, with a LOD of 57 nM. Determination of tyramine in yoghurt samples showed good recovery. In a study by Raoof et al. [157], a voltammetric sensor was developed to detect levodopa, UA and tyramine for the first time. The sensor was fabricated by the electrodepositing of quercetin on GCE modified with f-MWCNTs (Fig. 8). The prepared sensor showed an excellent electrocatalytic activity for levodopa, UA and tyramine oxidation and the LOD of tyramine reached to 0.647 μM. Moreover, the sensor shows to be promising for the analysis of levodopa, UA and tyramine in real samples without expensive and time-consuming pretreatments.
To the best of our knowledge, there has been no report in the literatures on biosensors for tyramine using CNs. The electrochemical biosensors for tyramine determination have been reported employing either monoamine or tyramine oxidase immobilized on different supports such as gelatin [158], 2-[4,6-bis (aminoethylamine)-1,3,5-triazine]-Silasorb [159], and flurophore sol–gel containing APTMS [160]. In a recent study by Lata et al., an amperometric biosensor was constructed by covalently immobilizing tyramine oxidase on an epoxy resin membrane [161]. Tyramine was measured specifically and leaching of enzyme was avoided. The LOD for tyramine was 0.24 mg dL−1, lower than that of tyramine oxidase immobilized on microtiter plate using sol gel fluorophore (6.30 mg dL−1) [160] and electrochemical sensor based on MWCNTs-AuNPs composite and CS (0.99 mg dL−1) [156]. The biosensor was successfully employed for determination of tyramine in beer and sauce items. Because of the very low LOD, this biosensor may have the sensitivity for future clinical and industrial applications.
Histamine
Histamine [1H-imidazole-4-ethanamine], is the most important biogenic amine present in many food products and acts as chemical messengers in biological systems. Histamine is a neurohormone synthesized in mast cells and a product in food synthesized by the microbial degradation of the amino acid histidine. Histamine is naturally present in many vegetables and fruits in amounts below toxic levels. The formation of high levels of histamine correlates strongly with the number of microorganisms present in histidine rich foods (vegetables, fermented foods and certain fish). The presence of histamine in foods is commonly used as an indicator of the state of deterioration of the product and frequently regarded as one of the biomarkers in quality control monitoring during the food production, storage and transportation [162, 163]. Traditionally, histamine has been determined by use of chromatographic and spectrographic techniques. Although electrochemical detection methods are inexpensive and can provide high sensitivity, not many works have been reported on this type of detection, probably due to the high oxidation potential (~1.2 V vs SCE) of histamine, at which conventional electrodes such as GCE exhibit high background currents due to oxidation of the solvent water or of the electrode material itself [164]. The reported electrochemical biosensors /sensors for histamine determination were mainly focused on boron-doped diamond electrode [164], nickel-film GCE [162], methylamine dehydrogenase immobilized in PPY film modified electrode [165], diamine oxidase screen-printed CPE [166] in the past few years. However, to the best of our knowledge, until now, there are no reports on electrochemical sensors/biosensors based on CNs for the detection of histamine.
Putrescine
Putrescine, also 1,4-diaminobutane, is one of important BA present in foods either as natural products or after fermentation, decomposition or putrefaction processes [167]. Putrescine has been implicated for the foul odour of putrefying flesh, bad breath and bacterial vaginosis. It has been used for various analytical and clinical purposes—plant stress markers, food spoilage and cancer markers [168]. Since putrescine plays a very important role in the metabolism of various biological tissues, its detection even at very low concentrations is critical.
Generally, the basic principle in the electrochemical detection of putrescine is its conversion to hydrogen peroxide by oxidase such as amino oxidase (AO), EC 1.4.3.4 [169], diamine oxidase (DAO), EC1.4.3.6 [170] and putrescine oxidase (PUO), EC 1.4.3.10 [171]. For both DAOs and PUOs, the enzymatic reaction of the diamines involves an oxidative deamination step with the liberation of ammonia and hydrogen peroxide:
Shanmugam et al. developed a highly sensitive rapid biosensor for detection of putrescine [170]. DAO, which was covalently linked to the iron oxide nanoparticles, was coated on GCE and a modified electrode referred to as DAO/nano-Fe3O4/GCE was used to sense putrescine by detecting the hydrogen peroxide released in the reaction. The LOD was 0.65 nM and 0.3 seconds was found to be as the response time. The ultrafast detection of low amounts of putrescine indicates that this biosensor may be used for clinical and analytical purposes.
Direct electron transfer between enzymes and the electrode was advantageous because of the potentially fast time response and lack of intermediate reactions that could cause interference. PUO is a rather big molecule (>200 kDa) with the redox center deeply inlaid in its structure. Hence, it is very difficult for the enzyme to directly exchange electrons with the electrode. CNTs are electrically conductive, it may pierce the glycoprotein shell and effectively reduce the distance between the redox site and the electrode surface, increasing sensitivity and decreasing response time. Luong and coworkers reported two MWCNTs based electrochemical biosensors for mediatorless detection of putrescine [168, 172]. GCE, coated with a mixture of MWCNTs, PDDA, APTES, and PUO, displayed oxidation/reduction peaks for FAD/FADH2 in the CV but an electrode lacking CNTs did not [168]. Mouse plasma was analyzed with good results compared to HPLC method, indicating that putrescine detection is also possible in mammalian plasma.
Sensors for the simultaneous determination of various biogenic amines
BA are synthesized and degraded during normal metabolism of animals, plants and microorganisms. Histamine, putrescine, cadaverine, tyramine, tryptamine, spermine and spermidine are considered to be some of the most important BA in food and in human body. BA detection has been shown to be a valuable tool for different analytical purposes, such as cancer markers or for assessing the freshness and quality of a wide variety of foodstuffs. Various methods have been developed for separation and quantification of BA and among then all, electrochemical detection has been considered to be a quick, efficient, sensitive, rapid and cheap alternative for the traditional ones. In this way, AOs based biosensors, which combine biological recognition through enzyme specificity with construction simplicity, have been reported in the literature [159, 169, 173–175]. Biosensors, especially the amperometric ones, have been the most successful and still have the most promising future for practical application. However, in the case of BA, there are few reports on biosensors employed by CNs for BA detection.
Conclusions
This review has offered an overview of the electrochemical sensors of BA using CNs. The incorporation of CNs into electrochemical sensors provided a means for increasing the sensitivity and selectivity of detection of BA because of their interesting designs, comprehensive and detailed study. Meanwhile, only few sensors are applicable to in vivo measurements in mammals or humans. In addition, the reports about simultaneous detection of different BA were also limited. Thus, considerable time and efforts are required to acquire further improvements.
Whereas, achieving higher sensitivity, selectivity, speediness, stability and reliability accuracy, automation have always been the driving forces in developing new electrochemical sensors for BA. We predict a bright future for CNs as sensing materials in fabricating of electrochemical sensors for BA. The recent Nobel Prize for graphene has sparked investigations of this new material in a variety of applications, including electrochemical sensors. Compared with other CNs, graphene and its derivatives are biocompatibility, lack of metallic impurities (which are a major obstacle in electrochemical sensing research with CNTs), high conductivity and abundance of inexpensive source material, which will play more important role. Moreover, functionalization of graphene and the combination of various other nanomaterials into graphene composites in order to explore their synergistic effects has become an interesting area of research.
References
Ascar A, Treptow H (1986) Biogene amine in lebensmitteln. Ulmer, Stuttgart
Silla Santos MH (1996) Biogenic amines: their importance in foods. Int J Food Microbiol 29:213–231
Halasz A, Barath A, Simon-Sarkadi L, Holzapfel W (1994) Biogenic-amines and their production by microorganisms in food. Trends Food Sci Technol 5:42–49
Shalaby AR (1996) Significance of biogenic amines to food safety and human health. Food Res Int 29:675–690
Suzzi G, Gardini F (2003) Biogenic amines in dry fermented sausages: a review. Int J Food Microbiol 88:41–54
Karovicova J, Kohajdova Z (2005) Biogenic amines in food. Chem Pap 59:70–79
Önal A (2007) A review: current analytical methods for the determination of biogenic amines in foods. Food Chem 103:1475–1486
Lapa-Guimarães J, Pickova J (2004) New solvent systems for thin-layer chromatographic determination of nine biogenic amines in fish and squid. J Chromatogr A 1045:223–232
Emilia GM, Carrascosa AV, Rosario M (2005) A rapid and inexpensive method for the determination of biogenic amines from bacterial cultures by thin-layer chromatography. J Food Protect 68:625–629
Awan MA, Fleet I, Thomas CLP (2008) Determination of biogenic diamines with a vaporisation derivatization approach using solid-phase microextraction gas chromatography–mass spectrometry. Food Chem 111:462–468
Almeida C, Fernandes JO, Cunha SC (2012) A novel dispersive liquid–liquid microextraction gas chromatography–mass spectrometry method for the determination of eighteen biogenic amines in beer. Food Control 11:462–468
Self RL, Wu WH, Marks HS (2011) Simultaneous quantification of eight biogenic amine compounds in tuna by matrix solid-phase dispersion followed by HPLC–orbitrap mass spectrometry. J Agric Food Chem 59:5906–5913
Jung MC, Shi GY, Borland L, Michael AC, Weber SG (2006) Simultaneous determination of biogenic monoamines in rat brain dialysates using capillary high-performance liquid chromatography with photoluminescence following electron transfer. Anal Chem 78:1755–1760
Cinquina AL, Cali A, Longo F, Santis LD, Severoni A, Abballe F (2004) Determination of biogenic amines in fish tissues by ion-exchange chromatography with conductivity detection. J Chromatogr A 1032:73–77
Borba BMD, Rohrer JS (2007) Determination of biogenic amines in alcoholic beverages by ion chromatography with suppressed conductivity detection and integrated pulsed amperometric detection. J Chromatogr A 1155:22–30
García-Villar N, Saurina J, Hernández-Cassou S (2006) Capillary electrophoresis determination of biogenic amines by field-amplified sample stacking and in-capillary derivatization. Electrophoresis 27:474–483
Steiner MS, Meier RJ, Spangler C, Duerkop A, Wolfbeis OS (2009) Determination of biogenic amines by capillary electrophoresis using a chameleon type of fluorescent stain. Microchim Acta 67:259–266
He L, Toh CS (2006) Recent advances in analytical chemistry - a material approach. Anal Chim Acta 556:1–15
Tretyakov YD, Goodilin EA (2009) Key trends in basic and application-oriented research on nanomaterials. Russ Chem Rev 78:801–820
Sudhir PR, Wu HF, Zhou ZC (2005) Identification of peptides using gold nanoparticle-assisted single-drop microextraction coupled with AP-MALDI mass spectrometry. Anal Chem 77:7380–7385
Cai YQ, Cai YE, Mou SF, Lu YQ (2005) Multi-walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of chlorophenols in environmental water samples. J Chromatogr A 1081:245–247
Gomes D, Nunes SP, Peinemann KV (2005) Membranes for gas separation based on poly(1-trimethylsilyl-1-propyne)–silica nanocomposites. J Membr Sci 246:13–25
Manzoori JL, Amjadi M, Darvishnejad M (2012) Separation and preconcentration of trace quantities of copper ion using modified alumina nanoparticles, and its determination by flame atomic absorption spectrometry. Microchim Acta 176:437–443
Song MJ, Hwang SW, Whang D (2010) Non-enzymatic electrochemical CuO nanoflowers sensor for hydrogen peroxide detection. Talanta 80:1648–1652
Zhang JJ, Gu MM, Zheng TT, Zhu JJ (2009) Synthesis of gelatin-stabilized gold nanoparticles and assembly of carboxylic single-walled carbon nanotubes/Au composites for cytosensing and drug uptake. Anal Chem 81:6641–6648
Zhang WD, Chen J, Jiang LC, Yu YX, Zhang JQ (2010) A highly sensitive nonenzymatic glucose sensor based on NiO-modified multi-walled carbon nanotubes. Microchim Acta 168:259–265
Liu H, Webster TJ (2007) Nanomedicine for implants: a review of studies and necessary experimental tools. Biomaterials 28:354–369
Willner I, Willner B (2010) Biomolecule-based nanomaterials and nanostructures. Nano Lett 10:3805–3815
Perez S, Farre ML, Barcelo D (2009) Analysis, behavior and ecotoxicity of carbon-based nanomaterials in the aquatic environment. TrAC Trends Anal Chem 28:820–832
Agüí L, Yáñez-Sedeño P, Pingarrón JM (2008) Role of carbon nanotubes in electroanalytical chemistry a review. Anal Chim Acta 622:11–47
Kaur A, Gupta U (2009) A review on applications of nanoparticles for the preconcentration of environmental pollutants. J Mater Chem 19:8279–8289
Pradeep T, Anshup (2009) Noble metal nanoparticles for water purification: a critical review. Thin Solid Films 517:6441–6478
Campbell FW, Compton RG (2010) The use of nanoparticles in electroanalysis: an updated review. Anal Bioanal Chem 396:241–259
Scida K, Stege PW, Haby G, Messina GA, García CD (2011) Recent applications of carbon-based nanomaterials in analytical chemistry: critical review. Anal Chim Acta 691:6–17
Dai LM, Chang DW, Baek JB, Lu W (2012) Carbon nanomaterials: carbon nanomaterials for advanced energy conversion and storage. Small 8:1122
Mauter MS, Elimelech M (2008) Environmental applications of carbon-based nanomaterials. Environ Sci Technol 42(5):5843–5859
Wang XN, Hu PA (2012) Carbon nanomaterials: controlled growth and field-effect transistor biosensors. Front Mater Sci 6:26–46
Kuchibhatla SVNT, Karakoti AS, Bera D, Seal S (2007) One dimension nanostructured materials. Prog Mater Sci 52:699–913
Yu DS, Nagelli E, Du F, Dai LM (2010) Metal-free carbon nanomaterials become more active than metal catalysts and last longer. J Phys Chem Lett 1:2165–2173
Sherigara BS, Kutner W, D’Souza F (2003) Electrocatalytic Properties and sensor applications of fullerenes and carbon nanotubes. Electroanalysis 15:753–772
Pavlidis IV, Vorhaben T, Stamatis H (2012) Development of effective nanobiocatalytic systems through the immobilization of hydrolases on functionalized carbon-based nanomaterials. Biotechnol Tech 115:164–171
Zhang RY, Olin H (2012) Carbon nanomaterials as drug carriers: real time drug release investigation. Mater Sci Eng C 32:1247–1252
Ajayan PM (1999) Nanotubes from carbon. Chem Rev 99:1787–1800
Iijima S (1991) Helical microtubules of graphitic carbon. Nature 354:56–58
Dresselhaus MS, Dresselhaus G, Jorio A (2004) Unusual properties and structure of carbon nanotubes. Annu Rev Mater Res 34:247–278
Thostenson ET, Ren ZF, Chou TW (2001) Advances in the science and technology of carbon nanotubes and their composites: a review. Compos Sci Technol 61:1899–1912
Dai HJ (2002) Carbon nanotubes: synthesis, integration, and properties. Acc Chem Res 35:1035–1044
Banks CE, Moore RR, Davies TJ, Compton RG (2004) Investigation of modified basal plane pyrolytic graphite electrodes: definitive evidence for the electrocatalytic properties of the ends of carbon nanotubes. Chem Commun 10:1804–1805
Banks CE, Davies TJ, Wildgoose GG, Compton RG (2005) Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites. Chem Commun 7:829–841
Banks CE, Crossley A, Salter C, Wilkins SJ, Compton RG (2006) Carbon nanotubes contain metal impurities which are responsible for the “electrocatalysis” seen at some nanotube-modified electrodes. Angew Chem Int Ed 45:2533–2537
Batchelor-McAuley C, Wildgoose GG, Compton RG, Shao LD, Green MLH (2008) Copper oxide nanoparticle impurities are responsible for the electroanalytical detection of glucose seen using multiwalled carbon nanotubes. Sensors Actuators B 132:356–360
Pumera M, Iwai H (2009) Metallic impurities within residual catalyst metallic nanoparticles are in some cases responsible for “electrocatalytic” effect of carbon nanotubes. Chem Asian J 4:554–560
Jacobs CB, Peairs MJ, Venton BJ (2010) Review: carbon nanotube based electrochemical sensors for biomolecules. Anal Chim Acta 662:105–127
Vashist SK, Zheng D, Al-Rubeaan K, Luong JHT, Sheu FS (2011) Advances in carbon nanotube based electrochemical sensors for bioanalytical applications. Biotechnol Adv 29:169–188
Gooding JJ (2005) Nanostructuring electrodes with carbon nanotubes: a review on electrochemistry and applications for sensing. Electrochim Acta 50:3049–3060
Li CY, Thostenson ET, Chou TW (2008) Sensors and actuators based on carbon nanotubes and their composites: a review. Compos Sci Technol 68:1227–1249
Wildgoose GG, Banks CE, Leventis HC, Compton RG (2006) Chemically modified carbon nanotubes for use in electroanalysis. Microchim Acta 152:187–214
Zhao YL, Stoddart JF (2009) Noncovalent functionalization of single-walled carbon nanotubes. Acc Chem Res 42:1161–1171
Wang J, Lin YH (2008) Functionalized carbon nanotubes and nanofibers for biosensing applications. TrAC Trends Anal Chem 27:619–626
Brumfiel G (2009) Graphene gets ready for the big time. Nature 458:390–391
Geim AK, Novoselov KS (2007) The rise of graphene. Nat Mater 6:183–191
Shao YY, Wang J, Wu H, Liu J, Aksay IA, Lin YH (2010) Graphene based electrochemical sensors and biosensors: a review. Electroanalysis 22:1027–1036
Geim AK (2009) Graphene: status and prospects. Science 324:1530–1534
Novoselov KS, Geim AK, Morozov SV, Jiang D, Zhang Y, Dubonos SV, Grigorieva IV, Firsov AA (2004) Electric field effect in atomically thin carbon films. Science 306:666–669
Lee C, Wei X, Kysar JW, Hone J (2008) Measurement of the elastic properties and intrinsic strength of monolayer graphene. Science 321:385–388
Berger C, Song ZM, Li TB, Li XB, Ogbazghi AY, Feng R, Dai ZT (2004) Ultrathin epitaxial graphite: 2D electron gas properties and a route toward graphene-based nanoelectronics. J Phys Chem B 108:19912–19916
Hass J, De Heer WA, Conrad EH (2008) The growth and morphology of epitaxial multilayer graphene. J Phys Condens Matter 20:1–27
Pumera M, Ambrosi A, Bonanni A, Chng ELK, Poh HL (2010) Graphene for electrochemical sensing and biosensing. TrAC Trends Anal Chem 29:954–965
Chen D, Tang LH, Li JH (2010) Graphene-based materials in electrochemistry. Chem Soc Rev 39:3157–3180
Pumera M (2010) Graphene-based nanomaterials and their electrochemistry. Chem Soc Rev 39:4146–4157
Brownson DAC, Banks CE (2010) Graphene electrochemistry: an overview of potential applications. Analyst 135:2768–2778
Shan CS, Yang HF, Song JF, Han DX, Ivaska A, Niu L (2009) Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene. Anal Chem 81:2378–2382
Liu KP, Zhang JJ, Yang JH, Wang CM, Zhu JJ (2010) Direct electrochemistry and electrocatalysis of hemoglobin based on poly(diallyldimethylammonium chloride) functionalized graphene sheets/room temperature ionic liquid composite film. Electrochem Commun 12:402–405
Zhou KF, Zhu YH, Yang XL, Luo J, Li CZ, Luan SR (2010) A novel hydrogen peroxide biosensor based on Au–graphene–HRP–chitosan biocomposites. Electrochim Acta 55:3055–3060
Wang YL, Peng W, Liu L, Tang M, Gao F, Li MJ (2011) Enhanced conductivity of a glassy carbon electrode modified with a graphene-doped film of layered double hydroxides for selectively sensing of dopamine. Microchim Acta 174:41–46
Li J, Guo SJ, Zhai YM, Wang E (2009) Nafion–graphene nanocomposite film as enhanced sensing platform for ultrasensitive determination of cadmium. Electrochem Commun 11:1085–1088
Li J, Guo SJ, Zhai YM, Wang E (2009) High-sensitivity determination of lead and cadmium based on the Nafion-graphene composite film. Anal Chim Acta 649:196–201
Shang NG, Papakonstantinou P, McMullan M, Chu M, Stamboulis A, Potenza A, Dhesi SS, Marchetto H (2008) Catalyst-free efficient growth, orientation and biosensing properties of multilayer graphene nanoflake films with sharp edge planes. Adv Funct Mater 18:3506–3514
Lang AE, Lozano AM (1998) Parkinson’s disease. N Engl J Med 339:1044–1053
Nikolaus S, Antke C, Müller HW (2009) In vivo imaging of synaptic function in the central nervous system: II. Mental and affective disorders. Behav Brain Res 204:32–66
Sun YX, Fei JJ, Hou J, Zhang Q, Liu YL, Hu BA (2009) Simultaneous determination of dopamine and serotonin using a carbon nanotubes-ionic liquid gel modified glassy carbon electrode. Microchim Acta 165:373–379
Wong DL (2006) Epinephrine biosynthesis: hormonal and neural control during stress. Cell Mol Neurobiol 26:891–900
Goyal RN, Bishnoi S (2011) A novel multi-walled carbon nanotube modified sensor for the selective determination of epinephrine in smokers. Electrochim Acta 56:2717–2724
Goyal RN, Bishnoi S (2011) Simultaneous determination of epinephrine and norepinephrine in human blood plasma and urine samples using nanotubes modified edge plane pyrolytic graphite electrode. Talanta 84:78–83
Beitollahi H, Karimi-Maleh H, Khabazzadeh H (2008) Nanomolar and selective determination of epinephrine in the presence of norepinephrine using CPE modified with carbon nanotubes and novel 2-(4-Oxo-3-phenyl-3,4-dihydro-quinazolinyl)- N-phenyl-hydrazinecarbothio-amide. Anal Chem 80:9848–9851
Raina S, Kang WP, Davidson JL (2010) Fabrication of nitrogen-incorporated nanodiamond ultra-microelectrode array for dopamine detection. Diamond Relat Mater 19:256–259
Breczko J, Plonska-Brzezinska ME, Echegoyen L (2012) Electrochemical oxidation and determination of dopamine in the presence of uricand ascorbic acids using a carbon nano-onion and poly (diallyldimethylammonium chloride) composite. Electrochim Acta 72:61–67
Goyal RN, Gupta VK, Bachheti N, Sharma RA (2008) Electrochemical sensor for the determination of dopamine in presence of high concentration of ascorbic acid using a fullerene-C coated gold electrode. Electroanalysis 20:757–764
Li J, Koehne JE, Cassell AM, Chen H, Ng HT, Ye Q, Fan W, Han J, Meyyappan M (2005) Inlaid multi-walled carbon nanotube nanoelectrode arrays for electroanalysis. Electroanalysis 17:15–27
Ates M, Castillo J, Sarac AS, Schuhmann W (2008) Carbon fiber microelectrodes electrocoated with polycarbazol and poly (carbazole-co-p-tolylsulfonyl pyrrole) films for the detection of dopamine in presence of ascorbic acid. Microchim Acta 160:247–251
Njagi J, Chernov MM, Leiter JC, Andreescu S (2010) Amperometric detection of dopamine in vivo with an enzyme based carbon fiber microbiosensor. Anal Chem 82:989–996
Koehne JE, Marsh M, Boakye A, Douglas B et al (2011) Carbon nanofiber electrode array for electrochemical detection of dopamine using fast scan cyclic voltammetry. Analyst 136:1802–1805
Britto PJ, Santhanam KSV, Ajayan PM (1996) Carbon nanotube electrode for oxidation of dopamine. Bioelectrochem Bioenerg 41:121–125
Zhao Y, Gao Y, Zhan DP, Liu H, Zhao Q, Kou Y, Shao YH, Li MX, Zhuang QK, Zhu ZW (2005) Selective detection of dopamine in the presence of ascorbic acid and uric acid by a carbon nanotubes-ionic liquid gel modified electrode. Talanta 66:51–57
Shahrokhian S, Zare-Mehrjardi HR (2007) Application of thionine-nafion supported on multi-walled carbon nanotube for preparation of a modified electrode in simultaneous voltammetric detection of dopamine and ascorbic acid. Electrochim Acta 52:6310–6317
Mazloum-Ardakani M, Beitollahi H, Ganjipour G, Naeimi H, Nejati M (2009) Electrochemical and catalytic investigations of dopamine and uric acid by modified carbon nanotube paste electrode. Bioelectrochemistry 75:1–8
Sathisha TV, Kumara Swamy BE, Chandrashekar BN, Thomas N, Eswarappa B (2012) Selective determination of dopamine in presence of ascorbic acid and uric acid at hydroxy double salt/surfactant film modified carbon paste electrode. J Appl Electrochem 674:57–64
Zhang MN, Gong KP, Zhang HG, Mao LQ (2005) Layer-by-layer assembled carbon nanotubes for selective determination of dopamine in the presence of ascorbic acid. Biosens Bioelectron 20:1270–1276
Zhang YZ, Pan Y, Su S, Zhang LP, Li SP, Shao MW (2007) A novel functionalized single-wall carbon nanotube modified electrode and its application in determination of dopamine and uric acid in the presence of high concentrations of ascorbic acid. Electroanalysis 19:1695–1701
Manjunatha R, Suresh GS, Melo JS (2010) Simultaneous determination of ascorbic acid, dopamine and uric acid using polystyrene sulfonate wrapped multiwalled carbon nanotubes bound to graphite electrode through layer-by-layer technique. Sensors Actuators B 145:643–650
Zheng D, Ye JS, Zhang WD (2008) Some properties of sodium dodecyl sulfate functionalized multiwalled carbon nanotubes electrode and its application on detection of dopamine in the presence of ascorbic acid. Electroanalysis 20:1811–1818
Dumitrescu I, Edgeworth JP, Unwin PR, Macpherson JV (2009) Ultrathin carbon nanotube mat electrodes for enhanced amperometric detection. Adv Mater 21:3105–3109
Yin TJ, Wei WZ, Zeng JX (2006) Selective detection of dopamine in the presence of ascorbic acid by use of glassy-carbon electrodes modified with both polyaniline film and multi-walled carbon nanotubes with incorporated β-cyclodextrin. Anal Bioanal Chem 386:2087–2094
Tu XM, Xie QJ, Jiang SY, Yao SZ (2007) Electrochemical quartz crystal impedance study on the overoxidation of polypyrrole–carbon nanotubes composite film for amperometric detection of dopamine. Biosens Bioelectron 22:2819–2826
Lin L, Cai YP, Lin RP, Yu L, Song CY, Gao HC, Li XK (2011) New integrated in vivo microdialysis-electrochemical device for determination of the neurotransmitter dopamine in rat striatum of freely moving rats. Microchim Acta 172:217–223
Liu AH, Honma I, Zhou HS (2007) Simultaneous voltammetric detection of dopamine and uric acid at their physiological level in the presence of ascorbic acid using poly(acrylic acid) -multiwalled carbon-nanotube composite-covered glassy-carbon electrode. Biosens Bioelectron 23:74–80
Kumar SA, Wang SF, Yang TC-K, Yeh CT (2010) Acid yellow 9 as a dispersing agent for carbon nanotubes: preparation of redox polymer–carbon nanotube composite film and its sensing application towards ascorbic acid and dopamine. Biosens Bioelectron 25:2592–2597
Zhang L, Shi ZG, Lang QH (2011) Fabrication of poly(orthanilic acid)–multiwalled carbon nanotubes composite film-modified glassy carbon electrode and its use for the simultaneous determination of uric acid and dopamine in the presence of ascorbic acid. J Solid State Electrochem 15:801–809
Liu XG, Peng YH, Qu XJ, Ai SY, Han RX, Zhu XB (2011) Multi-walled carbon nanotube-chitosan/poly(amidoamine)/DNA nanocomposite modified gold electrode for determination of dopamine and uric acid under coexistence of ascorbic acid. J Electroanal Chem 654:72–78
Zhang YZ, Cai YJ, Su S (2006) Determination of dopamine in the presence of ascorbic acid by poly(styrene sulfonic acid) sodium salt/single-wall carbon nanotube film modified glassy carbon electrode. Anal Biochem 350:285–291
Wang HS, Li TH, Jia WL, Xu HY (2006) Highly selective and sensitive determination of dopamine using a Nafion/carbon nanotubes coated poly(3-methylthiophene) modified electrode. Biosens Bioelectron 22:664–669
Kan XW, Zhao Y, Geng ZR, Wang ZL, Zhu JJ (2008) Composites of multiwalled carbon nanotubes and molecularly imprinted polymers for dopamine recognition. J Phys Chem C 112:4849–4854
Moreno M, Arribasa AS, Bermejo E, Chicharro M (2010) Selective detection of dopamine in the presence of ascorbic acid using carbon nanotube modified screen-printed electrodes. Talanta 80:2149–2156
Dursun Z, Gelmez B (2010) Simultaneous determination of ascorbic acid, dopamine and uric acid at Pt nanoparticles decorated multiwall carbon nanotubes modified GCE. Electroanalysis 22:1106–1114
Adekunle AS, Agboola BO, Kenneth JP, Ozoemena KI (2010) Electrocatalytic detection of dopamine at single-walled carbon nanotubes–iron (III) oxide nanoparticles platform. Sensors Actuators B 148:93–102
Jia D, Dai JY, Yuan HY, Lei L, Xiao D (2011) Selective detection of dopamine in the presence of uric acid using a gold nanoparticles-poly(luminol) hybrid film and multi-walled carbon nanotubes with incorporated β-cyclodextrin modified glassy carbon electrode. Talanta 85:2344–2351
Zhang Y, Yuan R, Chai YQ, Zhong X, Zhong HA (2012) Carbon nanotubes incorporated with sol–gel derived La(OH)3 nanorods as platform to simultaneously determine ascorbic acid, dopamine, uric acid and nitrite. Colloids Surf B 100:185–189
Lin M, Huang H, Liu Y, Liang CJ, Fei SD, Chen XF, Ni CL (2013) High loading of uniformly dispersed Pt nanoparticles on polydopamine coated carbon nanotubes and its application in simultaneous determination of dopamine and uric acid. Nanotechnology 24:065501
Yang QH, Xu WH, Tomita A, Kyotani T (2005) The template synthesis of double coaxial carbon nanotubes with nitrogen-doped and boron-doped multiwalls. J Am Chem Soc 127:8956–8957
Yang LJ, Jiang SJ, Zhao Y, Zhu L, Chen S, Wang XZ, Wu Q, Ma J, Ma YW, Hu Z (2011) Boron-doped carbon nanotubes as Metal-free electrocatalysts for the oxygen reduction reaction. Angew Chem Int Ed 123:7270–7273
Deng CY, Chen JH, Wang MD, Xiao CH, Nie Z, Yao SZ (2009) A novel and simple strategy for selective and sensitive determination of dopamine based on the boron-doped carbon nanotubes modified electrode. Biosens Bioelectron 24:2091–2094
Wu W, Zhu HR, Fan LZ, Liu DF, Renneberg R, Yang SH (2007) Sensitive dopamine recognition by boronic acid functionalized multi-walled carbon nanotubes. Chem Commun 23:2345–2347
Ali SR, Ma YF, Parajuli RR, Balogun Y, Lai WY-C, He HX (2007) A nonoxidative sensor based on a self-doped polyaniline/carbon nanotube composite for sensitive and selective detection of the neurotransmitter dopamine. Anal Chem 79:2583–2587
Wang Y, Li YM, Tang LH, Lu J, Li JH (2009) Application of graphene-modified electrode for selective detection of dopamine. Electrochem Commun 11:889–892
Tan L, Zhou KG, Zhang YH, Wang HX, Wang XD, Guo YF, Zhang HL (2010) Nanomolar detection of dopamine in the presence of ascorbic acid at β-cyclodextrin/graphene nanocomposite platform. Electrochem Commun 12:557–560
Kim YR, Bong S, Kang YJ, Yang Y, Mahajan RK, Kim JS, Kim H (2010) Electrochemical detection of dopamine in the presence of ascorbic acid using graphene modified electrodes. Biosens Bioelectron 25:2366–2369
Liu Q, Zhu X, Huo ZH, He XL, Liang Y, Xu MT (2012) Electrochemical detection of dopamine in the presence of ascorbic acid using PVP/graphene modified electrodes. Talanta 97:557–562
Han DX, Han TT, Shan CS, Ivaska A, Niu L (2010) Simultaneous determination of ascorbic acid, dopamine and uric acid with chitosan-graphene modified electrode. Electroanalysis 22:2001–2008
Hou SF, Kasner ML, Su SJ, Patel K, Cuellari R (2010) Highly sensitive and selective dopamine biosensor fabricated with silanized graphene. J Phys Chem C 114:14915–14921
Sheng ZH, Zheng XQ, Xu JY, Bao WJ, Wang FB, Xia XH (2012) Electrochemical sensor based on nitrogen doped graphene: simultaneous determination of ascorbic acid, dopamine and uric acid. Biosens Bioelectron 34:125–131
Wu L, Feng LY, Ren JS, Qu XG (2012) Electrochemical detection of dopamine using porphyrin-functionalized graphene. Biosens Bioelectron 34:57–62
Li FH, Chai J, Yang HF, Han DX, Niu L (2010) Synthesis of Pt/ionic liquid/graphene nanocomposite and its simultaneous determination of ascorbic acid and dopamine. Talanta 81:1063–1068
Zhang FY, Li YJ, Gu YE, Wang ZH, Wang CM (2011) One-pot solvothermal synthesis of a Cu2O/Graphene nanocomposite and its application in an electrochemical sensor for dopamine. Microchim Acta 173:103–109
Liu S, Yan J, He GW, Zhong DD, Chen JX, Shi LY, Zhou XM, Jiang HJ (2012) Layer-by-layer assembled multilayer films of reduced graphene oxide/gold nanoparticles for the electrochemical detection of dopamine. J Electroanal Chem 672:40–44
Li SJ, Deng DH, Shi Q, Liu SR (2012) Electrochemical synthesis of a graphene sheet and gold nanoparticle-based nanocomposite, and its application to amperometric sensing of dopamine. Microchim Acta 177:325–331
Mao Y, Bao Y, Gan SY, Li FH, Niu L (2011) Electrochemical sensor for dopamine based on a novel graphene-molecular imprinted polymers composite recognition element. Biosens Bioelectron 28:291–297
Liu B, Lian HT, Yin JF, Sun XY (2012) Dopamine molecularly imprinted electrochemical sensor based on graphene–chitosan composite. Electrochim Acta 75:108–114
Ping JF, Wu J, Wang YX, Ying YB (2012) Simultaneous determination of ascorbic acid, dopamine and uric acid using high-performance screen-printed graphene electrode. Biosens Bioelectron 34:70–76
Liu S, Xing XR, Yu JH, Lian WJ, Jie L, Cui M, Huang JD (2012) A novel label-free electrochemical aptasensor based on graphene–polyaniline composite film for dopamine determination. Biosens Bioelectron 36:186–191
Niu X, Yang W, Guo H, Ren J, Gao JZ (2013) Highly sensitive and selective dopamine biosensor based on 3, 4, 9, 10-perylene tetracarboxylic acid functionalized graphene sheets/multi-wall carbon nanotubes/ionic liquid composite film modified electrode. Biosens Bioelectron 41:225–231
Fukushima T, Kosaka A, Ishimura Y, Yamamoto T, Takigawa T, Ishii N, Aida T (2003) Molecular ordering of organic molten salts triggered by single-walled carbon nanotubes. Science 300:2072–2074
Kim SK, Kim D, Jeon S (2012) Electrochemical determination of serotonin on glassy carbon electrode modified with various graphene nanomaterials. Sensors Actuators B 174:285–291
Swamy BEK, Venton BJ (2007) Carbon nanotube-modified microelectrodes for simultaneous detection of dopamine and serotonin in vivo. Analyst 132:876–884
Njagi J, Ball M, Best M, Wallace KN, Andreescu S (2010) Electrochemical quantification of serotonin in the live embryonic zebrafish intestine. Anal Chem 82:1822–1830
Shahrokhiana S, Khafaji M (2010) Application of pyrolytic graphite modified with nano-diamond/graphite film for simultaneous voltammetric determination of epinephrine and uric acid in the presence of ascorbic acid. Electrochim Acta 55:9090–9096
Yogeswaran U, Thiagarajan S, Chen SM (2007) Nanocomposite of functionalized multiwall carbon nanotubes with nafion, nano platinum, and nano gold biosensing film for imultaneous determination of ascorbic acid, epinephrine, and uric acid. Anal Biochem 365:122–131
Valentini F, Palleschi G, Morales EL, Orlanducci S, Tamburri E, Terranova ML (2007) Functionalized single-walled carbon nanotubes modified microsensors for the selective response of epinephrine in presence of ascorbic acid. Electroanalysis 19:859–869
Beitollahi H, Ardakani MM, Ganjipour B, Naeimi H (2008) Novel 2,2′-[1,2-ethanediylbis(nitriloethylidyne)]-bis-hydroquinone double-wall carbon nanotube paste electrode for simultaneous determination of epinephrine, uric acid and folic acid. Biosens Bioelectron 24:362–368
Yi HC, Zheng DY, Hu CG, Hu SS (2008) Functionalized multiwalled carbon nanotubes through in situ electropolymerization of brilliant cresyl blue for determination of epinephrine. Electroanalysis 20:1143–1146
Moraes FC, Golinelli DLC, Mascaro LH, Machado SAS (2010) Determination of epinephrine in urine using multi-walled carbon nanotube modified with cobalt phthalocyanine in a paraffin composite electrode. Sensors Actuators B 148:492–497
Shahrokhian S, Saberi RS (2011) Electrochemical preparation of over-oxidized polypyrrole /multi-walled carbon nanotube composite on glassy carbon electrode and its application in epinephrine determination. Electrochim Acta 57:132–138
Li X, Chen MF, Ma XY (2012) Selective determination of epinephrine in the presence of ascorbic acid using a glassy carbon electrode modified with graphene. Anal Sci 28:147
Cui F, Zhang XL (2012) Electrochemical sensor for epinephrine based on a glassy carbon electrode modified with graphene/gold nanocomposites. J Electroanal Chem 669:35–41
Li Y, Umasankar Y, Chen SM (2009) Multiwalled carbon nanotubes with poly(NDGAChi) biocomposite film for the electrocatalysis of epinephrine and norepinephrine. Anal Biochem 388:288–295
Cooper SE, Venton BJ (2009) Fast-scan cyclic voltammetry for the detection of tyramine and octopamine. Anal Bioanal Chem 394:329–336
Huang JD, Xing XR, Zhang XM, He XR, Lin Q, Lian WJ, Zhu H (2011) A molecularly imprinted electrochemical sensor based on multiwalled carbon nanotube-gold nanoparticle composites and chitosan for the detection of tyramine. Food Res Int 44:276–281
Raoof JB, Ojani R, Amiri-Aref M, Baghayeri M (2012) Electrodeposition of quercetin at a multi-walled carbon nanotubes modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of levodopa, uric acid and tyramine. Sensors Actuators B 166–167:508–518
Yagodina OV, Nikolskaya EB (1997) The main factors of monoamine biosensor selectivity increasing. Sensors Actuators B 44:566–570
Wimmerova M, Macholan L (1999) Sensitive amperometric biosensor for the determination of biogenic and synthetic amines using pea seedlings amine oxidase: a novel approach for enzyme immobilisation. Biosens Bioelectron 14:695–702
Duong HD, Rhee J (2007) Preparation and characterization of sensing membranes for the detection of glucose, lactate and tyramine in microtiter plates. Talanta 72:1275–1282
Lata S, Yadav S, Bhardwaj R, Pundir CS (2011) Amperometric determination of tyramine in sauce and beer by epoxy resin biocomposite membrane bound tyramine oxidase. Sens Instrumen Food Qual 5:104–110
Švarc–Gajić JS, Stojanovic Z (2010) Electrocatalytic determination of histamine on a nickel-film glassy carbon electrode. Electroanalysis 22:2931–2939
Akbari-adergani B, Norouzi P, Ganjali MR, Dinarvand R (2010) Ultrasensitive flow-injection electrochemical method for determination of histamine in tuna fish samples. Food Res Int 43:1116–1122
Sarada BV, Rao TN, Tryk DA, Fujishima A (2000) Eectrochemical oxidation of histamine and serotonin at highly boron-doped diamond electrodes. Anal Chem 72:1632–1638
Bao LL, Sun DP, Tachikawa H, Davidson VL (2002) Improved sensitivity of a histamine sensor using an engineered methylamine dehydrogenase. Anal Chem 74:1144–1148
Keow CM, Bakar FA, Salleh AB, Heng LY, Wagiran R, Siddiquee S (2012) Screen-printed histamine biosensors fabricated from the entrapment of diamine oxidase in a photocured poly(HEMA) Film. Int J Electrochem Sci 7:4702–4715
Izquierdo-Pulido M, Hernandez-Jover T, Mariné-Font A, VidalCarou MC (1996) Biogenic amines in European beers. J Agric Food Chem 44:3159–3163
Rochette JF, Sacher E, Meunier M, Luong JHT (2005) A mediatorless biosensor for putrescine using multiwalled carbon nanotubes. Anal Biochem 336:305–311
Mureşan L, Valera RR, Frébort I, Popescu IC, Csöregi E, Nistor M (2008) Amine oxidase amperometric biosensor coupled to liquid chromatography for biogenic amines determination. Microchim Acta 163:219–225
Shanmugam S, Thandavan K, Gandhi S, Sethuraman S, Rayappan JBB, Krishnan UM (2011) Development and evaluation of a highly sensitive rapid response enzymatic nanointerfaced biosensor for detection of putrescine. Analyst 136:5234–5240
Carsol MA, Mascini M (1999) Diamine oxidase and putrescine oxidase immobilized reactors in flow injection analysis: a comparison in substrate specificity. Talanta 50:141–148
Luong JHT, Hrapovic S, Wang DS (2005) Multiwall carbon nanotube (MWCNT) based electrochemical biosensors for mediatorless detection of putrescine. Electroanalysis 17:47–53
Niculescu M, Ruzgas T, Nistor T, Frebort I, Sebela M, Pec P, Csoregi E (2000) Electrooxidation mechanism of biogenic amines at amine oxidase modified graphite electrode. Anal Chem 72:5988–5993
Lange J, Wittmann C (2002) Enzyme sensor array for the determination of biogenic amines in food samples. Anal Bioanal Chem 372:276–283
Carelli D, Centonze D, Palermo C, Quinto M, Rotunno T (2007) An interference free amperometric biosensor for the detection of biogenic amines in food products. Biosens Bioelectron 23:640–647
Acknowledgments
This work was supported by the National Natural Science Foundation of China (21275123, 20975088, 21105085, 31270988), Project of Hunan Provincial Natural Science Foundation of China (12JJ7002), Hunan Provincial Innovation Foundation For Postgraduate (CX2012B268), and Opening Fund of Key Laboratory of Chemical Biology and Traditional Chinese Medicine Research (Hunan Normal University), Ministry of Education (KLCBTCMR2011-6).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yang, X., Feng, B., He, X. et al. Carbon nanomaterial based electrochemical sensors for biogenic amines. Microchim Acta 180, 935–956 (2013). https://doi.org/10.1007/s00604-013-1015-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00604-013-1015-6