1 Introduction

Bearing capacity calculations are an important part of the design of foundations. The bearing capacity of a vertically loaded strip footing is generally evaluated using the superposition formula proposed by Terzaghi (1943). Terzaghi’s equation is based on the superposition principle to combine the effects of cohesion, surcharge, and soil weight. The resulting bearing capacity is expressed as:

$$q_{u} = \frac{1}{2}\gamma BN_{\gamma } + cN_{c} + qN_{q}$$
(1)

where γ is the unit weight, c the cohesion, B the width of the strip footing; Nc, Nq and Nγ are the bearing capacity factors, which represent the effects of the soil cohesion c, the surcharge q, and the soil unit weight γ, respectively. These bearing capacity factors depend only on the internal friction angle φ of the soil under the footing.

Many analytical and numerical methods can be used to calculate the vertical bearing capacity of a rigid strip footing; the limit equilibrium method is the most popular in practice because of its relative simplicity. In this method, collapse is assumed to occur as a result of sliding on a rupture surface and the failure criterion is assumed to be satisfied within the soil mass (Terzaghi 1943; Meyerhof 1951; Vesic 1973; Kumbhojkar 1993).

By means of the method of characteristics, commonly referred to as the slip-line method, Lundgren and Mortensen (1953), Hansen (1961), Bolton and Lau (1993) and Martin (2003) studied the bearing capacity of shallow foundations. This method based on integrating the equations of plastic equilibrium and is more rigorous.

Moreover, many researchers have used the limit analysis method to study the bearing capacity (Chen 1975; Michalowski 1997; Soubra 1999; Hjiaj et al. 2005). Limit analysis method includes upper bound and lower bound theorems. Limit analysis method includes upper bound and lower bound theorems. Michalowski (2005) indicated that the limit analysis theorems requires normality of the flow (associativity), therefore the theorems are not valid for soils that are governed by the nonassociative flow rule. The displacement finite element or finite-difference technique can also be used to derive approximate estimates of the bearing capacity (Frydman and Burd 1997; Yin et al. 2001; Erickson and Drescher 2002; Mabrouki et al. 2010; Loukidis and Salgado 2009). In this method, the shape and the failure mechanism are not necessary.

Current studies of bearing capacity for shallow foundations tend to rely on the hypothesis of a surface footing subjected to vertical loads. In practice, the footing is embedded in soil and subjected to inclined loads due to vertical V and horizontal H loads transmitted by the superstructure or inclined columns such as is transmission towers. To take into account, the effects of embedment and inclined loading, the conventional bearing capacity Eq. (1) is modified by the correction factors. The bearing capacity formula can be written as:

$$q_{u} = \frac{1}{2}\gamma BN_{\gamma } d_{\gamma } i_{\gamma } + {\text{cN}}_{\text{c}} d_{c} i_{c} + q{\text{\rm N}}_{q} d_{q} i_{q}$$
(2)

where dγ, dc and dq are the depth factors, iγ, ic and iq are the inclination factors.

Many researchers have investigated the problem of a surface strip footing on sand subjected to inclined loads. Meyerhof (1953) used the method of limit equilibrium to calculate the bearing capacity of foundations under inclined loads, for two different failure mechanisms, one for small inclinations and another for large inclinations. Also, Meyerhof (1963) proposed a depth factor for estimate the increase of bearing capacity by the shearing resistance of the soil above the foundation level. Furthermore, Hansen (1970) proposed a formula for depth and load inclination factors. Vesić (1975) proposed empirical modifications to Hansen’s expressions for the inclination factors. Tani and Craig (1995) suggested that the bearing capacity of a shallow foundation is independent of the soil strength above the level of the base of the footing (there were no embedment effects). Recently, Lyamin et al. (2007) presented results of rigorous analyses that employ to obtain values of depth factors for use in bearing capacity computations in the sand using the finite element. Recently, Loukidis et al. (2008) studied the bearing capacity of surface footings in sand subjected to eccentric and inclined loads using finite elements. They found that the inclination factor depends on the value of the friction angle, whereas the effective width does not. Most of the inclination factors iγ and depth factors dγ for cohesionless soil, available in the literature are given in Table 1.

Table 1 Expressions of depth factor dγ and inclination factor iγ

Many researchers suggested examining the bearing capacity of shallow foundations under general loading, by expressing the applied loads in terms of combinations of vertical, horizontal, and moment loading (Bransby and Randolph 1998, 1999; Gourvenec 2008). The load combinations that caused failure were plotted as a failure envelope on an interaction diagram.

Research in the field of offshore foundations has more recently been carried out under drained load conditions. Using physical model testing, Gottardi and Butterfield (1993) performed laboratory tests on surface footings on very dense sand under general planar loads, using three dimensional small-scale models. They showed that the interaction diagram approach to bearing capacity estimation for surface footings enables an engineer to take into account the interaction between different loading components. Also, Gottardi and Butterfield (1995) proposed load–displacement data for surface footings on dense sand covering a sufficiently wide range of inclined, eccentric, eccentric-inclined and “non-radial” load-paths, (including “unloading” phases) for important conclusions to be drawn about. By using the three-degree-of-freedom loading Gottardi et al. (1999) presented results of laboratory tests for circular footing under general planar loading on dense sand. They found that the shape of the yield surface is well described by a parabolic ellipsoid. Yun and Bransby (2003) presented results from a series of centrifuge model tests carried out to investigate the combined vertical, horizontal and moment loading response of skirted foundation on drained loose sand. They showed that the horizontal capacity of the skirted foundation was larger than that of raft foundation. There has been available little work studying the bearing capacity of embedded strip footings on cohesionless soil under combined loading.

The aim of this study is to directly investigate how variation in the embedment ratio (D/B) of a foundation affects its bearing capacity under inclined loadings in sand. To investigate this aspect of foundation behaviour, a series of finite difference analyses using the numerical code Fast Lagrangian Analysis of Continua (FLAC) (2005) were carried out for rigid foundations with different embedment ratio in sand. The friction angle and the inclination angle are varied carefully to cover most cases of practical interest. New information has been gained concerning the shape of the failure envelopes. The numerical results are compared with the available publications in the literature.

2 Numerical Modeling Procedure

The problem studied considers strip footings embedded in cohesionless soil, under combined loading (vertical and horizontal loads), as shown in Fig. 1. In this paper, the finite-difference code FLAC (2005) was used to reach the bearing capacity for embedded rough strip footings. The finite-difference code Fast Lagrangian Analysis of Continua (FLAC) is a two-dimensional program for geotechnical engineering; it simulates the behaviour of structures built of soil, rock or other materials that undergo plastic flow when their yield limits are reached.

Fig. 1
figure 1

Finite-difference mesh used in the analyses for the case of D/B = 0.5

In the current modeling study, the width B of the footing is 2 m and is embedded at a variable depth D. The embedment ratio D/B of 0 (surface), 0.25, 0.5, 0.75 and 1 were considered. Because of the absence of loading symmetry, the entire soil domain of dimensions (20B × 40B) is considered. Calculations for a larger mesh size indicated that extending the boundaries further away from the footing does not influence the computed limit load of the footing. The base of the model is constrained in all directions. The right and the left vertical sides are constrained in the horizontal direction only. The mesh adopted in the present study is shown in Fig. 1. The rigid footing is connected to the soil via interface elements defined by Coulomb shear-strength criterion. In the present study, the interface has a friction angle δ = φ (perfectly rough soil-footing interface), a cohesion c = 0, a normal stiffness Kn = 109 Pa/m, and a shear stiffness Ks = 109 Pa/m.

The soil was considered to be a linearly elastic-perfectly plastic material, obeying Mohr–Coulomb criterion with the associative flow rule with a unit weight γ = 20 kN/m3. The soil elastic properties used are the shear modulus G = 11.5 MPa and the bulk modulus K = 25 MPa (equivalent to a Young’s modulus E = 32 MPa and a Poisson’s ratio ν = 0.3). Mabrouki et al. (2010) indicated that the soil elastic parameters had a negligible effect on the value of the limit load of the strip footing; the only effect being that if the chosen values are high, the footing reaches the limit load at a smaller displacement. The friction angle φ was varied from 30° to 40° in 5° increments; for each value of the friction angle φ, the dilation angle was set to φ = ψ (associative flow rule). The analyses with a non-associative flow rule were carried out using dilation angles ψ presented in Table 2. The footing elastic properties used are the Young’s modulus E = 25 GPa and the Poisson’s ratio ν = 0.4. The values of the elastic parameters are large enough to ensure the rigid behavior of the foundation.

Table 2 Frictional angles and dilatancy angles used in finite difference analyses for non-associative flow rule

Both probe-type analyses and swipe-type analyses were carried out to identify the V–H failure envelope (where V and H are respectively the vertical and horizontal ultimate footing loads). In the first step of probe analyses, a vertical uniform stress (smaller than qu) is applied to the footing, then a damping of the system is introduced by running several cycles until a steady state of static equilibrium is developed in the soil. In second step a controlled horizontal velocity is applied to the nodes which discretize the footing. Displacement is increased until failure is reached. It is worthwhile noting that for displacement control, it is not possible to maintain a constant and predetermined value of the ratio H/V throughout the analysis.

Swipe tests, introduced by Tan (1990), are convenient, as a complete failure envelope in a two-dimensional loading plane can be determined in a single test. The swipe tests involve first bringing the foundation to vertical bearing failure, and subsequently applying horizontal velocity while not allowing the footing to move vertically.

The swipe analysis was originally introduced by Tan (1990) as an experimental technique and later used by some researchers (Bransby and Randolph 1998; Gourvenec and Randolph 2003). The benefit of this procedure of loading is that the failure envelope in the V–H space can be determined with one finite difference analysis runs. To define the failure envelope, two paths, path I and path II are required. The path I of swipe tests consists of two steps. In the first step the loading of the rigid footing is simulated by imposing equal vertical velocities at the nodes represented the footing. The progressive movement of the rigid footing induced by the vertical velocity applied at the footing nodes is accompanied by an increase of the pressure in the soil. Finally, the pressure under the footing stabilizes for a value that indicates the ultimate vertical load (Vult). In the second step, horizontal velocity is applied until ultimate horizontal load is reached while not allowing the footing to move vertically. Furthermore, in the path II the horizontal velocity is applied to the footing without considering vertical loads, by using glued interfaces between the base for footing and soil. The two types of analyses are presented in Fig. 2.

Fig. 2
figure 2

Failure envelopes for V–H loading. a Probe analyses. b Swipe analyses

3 Results and Discussions

3.1 Vertical Bearing Capacity of a Surface Footing

The numerical modeling procedure was first validated for the vertical bearing capacity problem. From Eq. (1), for a strip footing under vertical load on cohesionless soil with no surcharge, the bearing capacity factor Nγ is:

$${\text{N}}_{\upgamma} = 2{\text{q}}_{\text{u}} /\upgamma{\text{B}}$$
(3)

Figure 3 compares the bearing capacity factor Nγ for rough footings under vertical load with φ = 30°, 35°, and 40°. The present results of the bearing capacity factor Nγ, are obtained from calculations with the non-associative flow rule (φ = ψ). We can observe that the results of the present study are in good agreement with the solutions reported by Terzaghi (1943). Also, the values of Nγ obtained from the present study are smaller than those obtained by Soubra (1999) and Bolton and Lau (1993). The solutions reported by Martin (2003) (using the method of characteristics) are significantly smaller than those determined by the present study. It is worthwhile noting that the refinement of mesh with a small vertical velocity produce a slightly better (lower values) results of Nγ. The present study produces good estimates of Nγ for surface strip footings.

Fig. 3
figure 3

Bearing capacity factor Nγ from finite difference analyses compared with other available theoretical predictions

3.2 Influence of Nonassociativity

It was confirmed by de Mabrouki et al. (2010), Erickson and Drescher (2002) and Yin et al. (2001) that the bearing capacity factors decreases with decreasing values of ψ. The effect of flow rule non-associativity (ψ < φ) is illustrated in Fig. 4 in the form of load–displacement curves (i.e., the curves of the bearing capacity factor Nγ versus δ/B, where, δ is the vertical displacement). The friction angle φ equal to 35°, 40° with dilation angles ψ = φ/3 and ψ = φ are used. It is seen that the Nγ values obtained from the analyses with the non-associative flow rule are lower than those with the associative flow rule, the difference increases with the increase of internal frictional angle φ of soil. It should be noted that for ψ = φ/3, the curve of Nγ versus δ/B shows numerical oscillation, which can be attributed to the inherent numerical aspect of the FLAC code as explained by Yin et al. (2001). In this case the bearing capacity factor Nγ is calculated as a mean value within the range of the oscillations. The same tendencies are observed by Loukidis et al. (2008) and Mabrouki et al. (2010).

Fig. 4
figure 4

Ratio 2qu/γB versus vertical displacement for rough footing, with friction angle, φ = 35° and 40° and two values of dilation angle, ψ = 1/3 φ and ψ = φ

A second effect of the non-associative flow rule is shown by Fig. 5. The Figure presents the displacement vectors of the soil with friction angle φ = 35° and for different values of ψ (ψ = φ, ψ = 2/3 φ, ψ = 1/3 φ). It is noted that the value of the maximum magnitude of the displacement vectors (dmax) varies with dilatancy angle ψ. With decreasing ψ, the displacements next to the footing edge decrease significantly. Figure 5a shows that for a large value of dilatancy angle (ψ = φ), significant displacements are restricted to the exterior region close to the edge of the footing. As explained by Yin et al. (2001), the large value of displacement that occurred in the region of the footing edge may not be realistic but shall not affect the calculation of Nγ.

Fig. 5
figure 5

Displacement vectors a ψ = φ; b ψ = 2/3 φ; c ψ = 1/3 φ

3.3 Effect of Load Inclination on the Bearing Capacity of a Surface Footing

3.3.1 Inclination Factor

The influence of load inclination on the bearing capacity of strip footings is estimated by inclination factor iγ, defined as the ratio of the limit load for a strip footing under inclined loading Vult,α≠0 to that of the footing under centered vertical loads Vult,α=0 (iγ = Vult,α/Vult,α=0). Figure 6 shows the inclination factors plotted against tan α (H/V). It can be seen from this figure that iγ decreases as the load inclination α increasing with a rate that is adequately captured by Hansen (1970). The numerical prediction obtained using the finite difference code FLAC is in good agreement with the factor of inclination proposed by Loukidis et al. (2008) based on the finite element. The results given by Vesić (1975) are reasonably close to the present results over a wide range of friction angles and load inclinations, though they are unconservative for high values of φ. For higher values of φ The Hansen theory gives results which are always conservative. Moreover, the Meyerhof predictions are conservative for all values φ ≤ 35°.

Fig. 6
figure 6

Inclination factor as a function of the load inclination α a φ = 30°, b φ = 35°, and c φ = 40°

3.3.2 Failure Envelopes

The results from probe and swipe analyses of failure envelopes (called also yield surface) for different values of angle of friction φ are presented in Fig. 7. The paths generated from V–H (vertical load-horizontal load) swipe and probe analyses normalized with respect to the corresponding Vult (Ultimate vertical load). It is seen that the size and shape of the normalized V–H failure envelopes depend slightly on the value of frictional soil φ. It can also be observed from Fig. 7, that the results from the probe analyses are generally in good agreement with the swipe analyses.

Fig. 7
figure 7

Comparison between the present V–H failure envelope from probe and swipe analyses

Loukidis et al. (2008) assumed that there are no interface elements at the soil–footing contact plane, so any slippage between footing and soil occurs within the soil. Numerical analyses were performed to examine the shape of failure envelopes obtained with and without interface elements at the soil–footing contact. Figure 7 shows the good agreement between the results obtained with and without interface element. It is seen that the path II of swipe analysis, obtained by using an unlimited tensile resistance at the interface is similar to that obtained when no interface elements placed between the footing and the soil. Figure 8 shows the effect of non-associativity on the failure envelopes. It is clear that the analyses with a non-associative flow rule ψ < φ, numerical oscillations in the path I are observed. Moreover, for the case of path I, there is poor agreement between the probe and swipe analyses.

Fig. 8
figure 8

Comparison of V–H failure envelopes for φ = 35°, 40° and ψ = 1/3 φ

Figure 9 presents the yield surface relating the applied vertical (V) and horizontal (H) loads from results of probe analyses normalized by division by Vult. The Figure demonstrated that the load paths followed is remarkably close to a parabolic shape. A similar observation was presented by Gottardi et al. (1999) for circular footings on sand under general planar loading. The maximum value H = 0.11Vult and occur at V/Vult = 0.48. It is worthwhile noting that the experimental values for Hmax are of the order of 0.12Vult (Gottardi and Butterfield 1993). The comparison of the present results with the existing solutions shows that the numerical simulations are very close to the results of Loukidis et al. (2008). However, the present solutions overestimate the results given by Hansen (1970) and Vesić (1975).

Fig. 9
figure 9

Comparison of present V–H failure envelopes with those of Loukidis et al. (2008), Vesić (1975) and Hansen (1970) for φ = 30° and ψ = φ

3.4 Effect of Load Inclination on the Bearing Capacity of Embedded Strip Footing

3.4.1 Depth Factor

The finite difference results are also used to derive depth factors dγ. This is achieved by dividing the bearing capacities obtained for the footings at depth D by that obtained for the surface footing (dγ = Vult, D/B/Vult, D/B=0). Figure 10 shows the depth factor against D/B for the three values of friction angle φ considered. The relationship between dγ and D/B is almost perfectly linear. Figure 9 proves that the degree of embedment affects significantly the bearing capacity of the foundation for a given value of frictional angle φ. More importantly it is seen that dγ is greater than 1 and increases with increasing D/B for all values of friction angle φ. The values of dγ proposed by Meyerhof (1963), Hansen (1970), Vesić (1975) and Lyamin et al. (2007) (for φ = 30°) are also presented. The depth factor dγ was taken as 1 by both Vesic (1973) and Hansen (1970), as seen in Table 1. Conceptually, a value of dγ = 1 means that the Nγ term refers only to the slip mechanism that forms below the base of the footing as explained by Lyamin et al. (2007). The values of depth factor found by finite difference analyses are larger than those proposed by Meyerhof (1963), Hansen (1970) and Vesić (1975) when the results of Lyamin et al. (2007) overestimate the influence of the embedment.

Fig. 10
figure 10

Comparison of present dγ values with those obtained from the expressions available in the literature

3.4.2 Inclination Factor

The effect of load inclination on bearing capacity of embedded strip footing in cohesionless soil is presented in Fig. 11. In this case, the load inclination factor iγ, defined as the ratio of the limit load for embedded footings under inclined loading Vult,α≠0 to that of the embedded footing under centered vertical loads iγ = Vult(α≠0, D/B≠0)/Vult(α=0, D/B≠0). Figure 11 shows the inclination factors obtained by swipe analyses for different values of ratios D/B (0 (surface), 0.25, 0.5, 0.75 and 1). It is seen that for small values of load inclination the embedment depth does not significantly affect iγ. However, for higher values of load inclination, the embedment depth produces inclination factors larger than those obtained for a surface footing; consequently, the footing embedment reduces the effect of load inclination.

Fig. 11
figure 11

Inclination factors of embedded footings for φ = 30° and ψ = φ

3.4.3 Failure Envelopes

Figure 12 shows failure envelopes under combined vertical and horizontal load for each of the embedment ratios considered: D/B = 0 (surface), 0.25, 0.5, 0.75 and 1. As seen from Fig. 12a, the expansion of failure envelopes indicates the increased load-carrying capacity available with increased embedment ratio. The figure also clearly shows good agreement between the probe and swipe results, especially for D/B ≤ 0.75. The normalized yield surface presented in Fig. 12b shows that the shape of the envelopes appears similar but is not unique. The size of the normalised envelope increases with increasing embedment ratio.

Fig. 12
figure 12

Comparison between the present V–H failure envelopes from probe and swipe analyses for D/B = 0, 0.25, 0.5, 0.75, 1 for φ = 30°

3.4.4 Failure Mechanisms

Figure 13 shows the contours of maximum shear strain for both surface and embedded footings under vertical or inclined loading. The elastoplastic finite difference analysis clearly show that different mechanisms depending on the loading conditions. It is noted that under displacement control, it is not possible to maintain a constant and predetermined value of the ratio H/V (tan α) throughout the analysis, for this a close values of α are presented. The size of the shear zone decreases with increasing of the load inclination. As seen from Fig. 13, for pure vertical loading (α = 0), there is a triangular elastic wedge immediately underneath the footing and the shear zone is similar to the failure mechanism found by Prandtl (1920) and Terzaghi (1943). However, more α > 0, the failure mechanism is asymmetrical and confined to one side of the footing for higher values of α. Also, it is observed that the value of the maximum magnitude of the displacement vectors varies with the depth of embedment: for larger depth the maximum displacement is higher.

Fig. 13
figure 13

Contours of maximum shear strain for different load inclinations for φ = 35°

4 Conclusions

The finite-difference code FLAC (2005) was used to study the bearing capacity for strip footing embedded in frictional soil under inclined loading. The soil used in the model was assumed to be a Mohr–Coulomb material with associative flow rule non- associative flow rules. Both probe-type and swipe-type analyses were carried out to identify failure envelopes under vertical and horizontal loading. The results are presented in terms of ultimate limit states. The numerical results are compared with ultimate loads predicted by the theories of Meyerhof, Hansen and Vesić and the available results published in the literature.

From the numerical study performed it is confirmed that the bearing capacity factor Nγ is very sensitive to the value of friction angle φ. The dilation angle has significant influences on the values of the bearing capacity factor Nγ. This effect is very important for higher values of the friction angle. The bearing capacity factors increases with the increasing of the dilation angle. The values of dilatation angle ψ affect the displacement vectors at failure of the strip footing, the displacements decrease with decreasing dilation angle.

The shape of the yield surface in V–H plane is well described by a parabolic form, as observed previously by Gottardi et al. (1999). The size and shape of the normalized V–H yield surface depends on the value of dilation angle. The normalized failure envelopes obtained with the associative flow rule, using the probe-type analyses are in very good agreement with those computed by swipe-type analyses; however, the discrepancy widens for non-associative flow rule. The finite difference analyses show that the size of failure envelopes for an embedded strip footing, under vertical and horizontal loading varies with the depth of embedment. The contours of the maximum shear strain prove the existence of one sided failure mechanism for higher values of α, with the formation of an asymmetrical elastic wedge. The values of iγ obtained from the present study for a surface footing are in good agreement with the solutions reported by Loukidis et al. (2008). For higher values of load inclination the factor iγ depends on the depth of embedment.