Abstract
Deep brain stimulation (DBS) is an invasive therapeutic option for patients with Parkinson’s disease (PD) but the mechanisms behind it are not yet fully understood. Animal models are essential for basic DBS research, because cell based in-vitro techniques are not complex enough. However, the geometry difference between rodents and humans implicates transfer problems of the stimulation conditions. For rodents, the development of miniaturized mobile stimulators and adapted electrodes are desirable. We implanted uni- and bipolar platinum/iridium electrodes in rats and were able to establish chronical instrumentation of freely moving rats (3 weeks). We measured the impedance of unipolar electrodes in-vivo to characterize the influence of electrochemical processes at the electrode-tissue interface. During the encapsulation process, the real part of the electrode impedance at 10 kHz doubled after 12 days and increased almost 10 times after 22 days. An outlook is given on the quantification of the DBS effect by sensorimotor behavioral tests.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Keywords
References
Adler, A., Amyot, R., Guardo, R., Bates, J.H., Berthiaume, Y.: Monitoring changes in lung air and liquid volumes with electrical impedance tomography. Journal of Applied Physiology 83(5), 1762–1767 (1997)
Braak, H., Braak, E.: Pathoanatomy of Parkinson’s disease. Journal of Neurology 247(2), II3–II10 (2000)
Benabid, A.L., Pollak, P., Louveau, A., Henry, S., de Rougemont, J.: Combined (thalamotomy and stimulation) stereotactic surgery of the VIM thalamic nucleus for bilateral Parkinson disease. Applied Neurophysiology 50(1-6), 344–346 (1987)
Foster, K.R., Schwan, H.P.: Dielectric properties of tissues and biological materials: a critical review. Critical Reviews in Biomedical Engineering 17(1), 25–104 (1989)
Gimsa, J., Habel, B., Schreiber, U., van Rienen, U., Strauss, U., Gimsa, U.: Choosing electrodes for deep brain stimulation experiments – electrochemical considerations. Journal of Neuroscience Methods 142(2), 251–265 (2005)
Gimsa, U., Schreiber, U., Habel, B., Flehr, J., van Rienen, U., Gimsa, J.: Matching geometry and simulation parameters of electrodes for deep brain stimulation experiments – numerical considerations. Journal of Neuroscience Methods 150(2), 212–227 (2006)
Grill, W.M., Mortimer, J.T.: Electrical properties of implant encapsulation tissue. Annals of Biomedical Engineering 22(1), 23–33 (1994)
Henning, J.: Wirkungen der tiefen Hirnstimulation – Analyse der Gen- und Proteinexpression in einem optimierten Rattenmodell. Dissertation. University of Rostock (2007)
Harnack, D., Winter, C., Meissner, W., Reum, T., Kupsch, A., Morgenstern, R.: The effects of electrode material, charge density and stimulation duration on the safety of high-frequency stimulation of the subthalamic nucleus in rats. Journal of Neuroscience Methods 138(1-2), 207–216 (2004)
Kerner, T.E., Paulson, K.D., Hartov, A., Soho, S.K., Poplack, S.P.: Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects. IEEE Transactions on Medical Imaging 21(6), 638–645 (2002)
Journal of Neurophysiology 99(6), 2902–2915 (2008)
Lempka, S.F., Miocinovic, S., Johnson, M.D., Vitek, J.L., McIntyre, C.C.: In vivo impedance spectroscopy of deep brain stimulation electrodes. Journal of Neural Engineering 6, 046001, 11 (2009)
Lempka, S.F., Johnson, M.D., Moffitt, M.A., Otto, K.J., Kipke, D.R., McIntyre, C.C.: Theoretical analysis of intracortical microelectrode recordings. Journal of Neural Engineering 8(4), 045006 (2011)
Macdonald, J.R.: Impedance spectroscopy. Annals of Biomedical Engineering 20(3), 289–305 (1992)
Nowak, K.A., Mix, E., Gimsa, J., Strauss, U., Sriperumbudur, K.K., Benecke, R., Gimsa, U.: Optimizing a rodent model of Parkinson’s disease for exploring the effects and mechanisms of deep brain stimulation. Parkinson’s Disease, 414682 (2011)
Paxinos, G., Watson, C.: The rat brain in stereotaxic coordinates. Academic Press, San Diego (1998)
Strauss, U., Zhou, F.W., Henning, J., Battefeld, A., Wree, A., Köhling, R., Haas, S.J., Benecke, R., Rolfs, A., Gimsa, U.: Increasing extracellular potassium results in subthalamic neuron activity resembling that seen in a 6-hydroxydopamine lesion
Wintermantel, E., Ha, S.W.: Medizintechnik mit biokompatiblen Werkstoffen und Verfahren, 3rd edn., pp. 134–135. Springer, Berlin (2002)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Badstübner, K., Kröger, T., Mix, E., Gimsa, U., Benecke, R., Gimsa, J. (2013). Electrical Impedance Properties of Deep Brain Stimulation Electrodes during Long-Term In-Vivo Stimulation in the Parkinson Model of the Rat. In: Gabriel, J., et al. Biomedical Engineering Systems and Technologies. BIOSTEC 2012. Communications in Computer and Information Science, vol 357. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-38256-7_19
Download citation
DOI: https://doi.org/10.1007/978-3-642-38256-7_19
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-38255-0
Online ISBN: 978-3-642-38256-7
eBook Packages: Computer ScienceComputer Science (R0)