Abstract
This paper presents a comprehensive second law-based thermodynamic analysis of a heavy oil-fired high-pressure boiler used in a steam power plant. The entire boiler region is divided into four zones to determine the magnitudes of energy loss and irreversibility taking place in these zones so that measures may be taken to reduce them. The energy analysis reveals that the maximum loss of combustion energy of the fuel takes place in the last zone where the exhaust gasses leave the chimney and taken away by these gases, whereas the exergy analysis reveals that the irreversibility rate in the first zone, i.e., furnace region, is the highest as compared to that in other zones. In this zone, 29.26 % of the fuel exergy is destroyed, while the energy loss is zero. In the chimney zone, where the energy loss is the maximum, the exergy destruction is just 4.64 %. Therefore, the real loss is actually taking place in the boiler furnace due to the generation of entropy. The chemical reactions between the fuel and air are the main cause of irreversibility. Decreasing either the percentage of excess combustion air or the exhaust gas temperature or both will cause the irreversibility rate in the furnace to decrease.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Boiler is a major component of a steam power plant. In the boiler, steam is generated at the desired rate and at the desired pressure and temperature by burning fuel in its furnace. The performance of the power plant depends a great deal on the performance of the boiler. It is a complex integration of furnace, evaporator, superheater, economizer, and air preheater along with various auxiliaries such as burners, fans, pumps, and chimney. The demand for the higher efficiency of the boiler and associated plant is continuously increasing due to diminishing fossil fuel resources and growing concerns for the environment. This requires improvement in the boiler design. Before any effort to improve the boiler design is undertaken, a thorough thermodynamic analysis of the boiler under consideration is required to locate the areas of maximum thermodynamic losses. The areas of maximum thermodynamic losses are the areas which have the maximum potential for improvement.
The traditional method of thermodynamic analysis is based on the first law of thermodynamics in which an energy balance is applied on the system under consideration, e.g., [1]. Energy balances provide no information about internal losses and changes in energy quality during a process. The second law analysis, also called exergy analysis, overcomes this short coming of the first law and is based on the concept of exergy defined as the maximum useful work that can be obtained in a process in which the system comes to equilibrium with the surroundings or attains the dead state [2, 3]. In this analysis, an exergy balance is applied to a process or a system to know how much of the exergy input to the system under consideration has been utilized and how much has been lost. The loss of exergy or irreversibility provides a quantitative measure of process inefficiency.
A number of researchers have made contributions to the theory and practice of exergy analysis [2, 4–12]. Many researchers have applied this analysis to study and improve the thermodynamic performance of steam power plants. Nag and De [13] applied a thermodynamic analysis based on the minimization of entropy generation to the optimal design and operation of a heat recovery steam generator (HRSG) generating saturated steam for a combined gas and steam power cycle. Dincer and Al-Muslim [14] conducted a thermodynamic analysis of a Rankine cycle reheat steam power plant in terms of the first law of thermodynamic analysis (i.e., energy analysis) and the second law analysis (i.e., exergy analysis), using a spreadsheet calculation technique. Sengupta et al. [15] conducted exergy analysis of a coal-based 210-MW thermal power plant. Kopac and Hilalci [16] studied the effect of ambient temperature on the efficiency of the regenerative and reheat Catalagzı steam power plant in Turkey. Aljundi [17] conducted energy and exergy analysis of a 66-MW steam power plant unit in Jordan that uses heavy oil as fuel. Teerawat and Adisorn [18] determined best design and operating conditions for the maximum power plant efficiency of both subcritical and supercritical pulverized coal-fired power plants. Guo and Yang [19] established models for energy analysis, entropy analysis, and exergy analysis for a boiler operating under unsteady conditions. Singh and Kaushik [20] carried out the exergy analysis of a 67.5-MW unit of a pulverized coal-fired steam power plant situated in India. This analysis has also been successfully applied to improve and innovate other power generation systems such as gas turbine cycles [21], gas–steam combined cycle [22], Kalina cycles [23–25], absorption power/cooling combined cycles [26], and cogeneration [27]; and various other systems such as solar-assisted ground-source heat pump greenhouse heating system [28], low-temperature solar thermal electric generation using regenerative organic Rankine cycle [29], solar cookers [30], waste heat recovery system with Canopus heat exchanger in an industrial refrigeration and air-conditioning unit [31], domestic refrigerator using eco-friendly R290/R600a refrigerant mixture [32], and solar air heater [33].
In the exergy analysis of the coal-fired steam power plant carried out by Singh and Kaushik [20], it was found that the maximum destruction of fuel exergy occurs in the boiler system where about 63 % of fuel exergy is destroyed. Therefore, in this work, a heavy oil-fired high-pressure boiler of a steam power plant is considered and divided into four subregions. Energy and exergy analysis of each subregion has been carried out separately to determine the magnitude of energy and exergy losses taking place in each subregion. The aim of this study is to identify the locations of thermodynamic inefficiencies in different zones of the considered boiler and to assess their magnitude and causes.
Boiler description
The schematic diagram of the boiler under consideration is shown in Fig. 1. It is a heavy fuel oil-fired, natural circulation, artificial draft, water-tube boiler. Water at 200–250 °C (depending on the operating pressure of the boiler) from the high-pressure feed-water heater enters the economizer and leaves it as a two-phase mixture of low dryness fraction. It then enters the steam drum. From the steam drum, it flows through insulated downcomers into the headers situated outside the furnace. The whole furnace region is surrounded by tubes backed by refractory walls. The headers are connected to these tubes so that water flows through them and these tubes act as risers. The water in the riser tubes receives heat from the combustion gases mainly by radiation. As the burned gases move upward and secondary air is added, the effect of radiation is reduced and the convection becomes predominant. The heat transfer in this zone takes place by convection as well as radiation. So, radiant and convective evaporators are located in this zone. As the gases travel further, the heat transfer takes place purely by convection and the temperature is the highest here. Therefore, superheater is located in this zone. As the gases transfer most of their heat to the evaporating water and superheating steam, their temperature reduces. Therefore, in this zone, heat recovery units like economizer and air preheater are located. The circulation of water in the tubes of the boiler is caused by natural convection due to density difference caused by the temperature gradient. The arrangement of parallel tubing is used to reduce the pressure loss and to have better control over the quality of steam. A combination of forced and induced draft is provided by means of two fans known as FD Fan and ID Fan. The specifications and the operating data of the boiler are presented in Table 1.
Net calorific value and standard chemical exergy of fuel
Number of kmols of various components in 100 kg mass of fuel
Number of kmols of a component in 100 kg mass of fuel is given by
Using the equation above, the number of kmols of C, H2, S, O2, and N2 in 100 kg mass of fuel is calculated as 6.975, 5.075, 0.1175, 0.0375, and 0.041, respectively.
Chemical equations for complete combustion of fuel
The chemical equations for the combustion of combustible components of fuel can be written as
Stoichiometric air–fuel ratio
Air contains 21.0 % oxygen and 79 % nitrogen by volume. Therefore, for each kmol of oxygen, 3.76 kmol of nitrogen is involved.
Therefore, the number of kmols of air required for complete combustion of 100 kg of fuel can be given as,
Therefore, the theoretical mass of air required for complete combustion of 100 kg of fuel can be given as,
Theoretical air–fuel ratio on a mass basis can be given as,
Actual air–fuel ratio
The boiler uses 30 % excess air to ensure complete combustion of fuel.
Therefore,
Mass flow rate of air
Mass flow rate of air,
Number of kmols of products for the combustion of 100 kg of fuel
From the combustion equations, for 100 kg of fuel, \( n_{{{\text{CO}}_{2} }} = 6.975 \), \( n_{{{\text{H}}_{2} {\text{O}}}} = 5.075 \), and \( n_{{{\text{SO}}_{2} }} = 0.1175 \) kmol.
The boiler uses 30 % excess air. Therefore, O2 in the products of combustion is given by,
Nitrogen does not take part in the combustion. Therefore, N2 in the products of combustion is same as that present in the fuel and incoming air, i.e.,
Mass flow rate of gases
Mass of a gaseous component of the products per 100 kg of fuel is given by,
Using the equation above, the masses of CO2, H2O, N2, O2, and SO2 can be calculated. The total mass of combustion gases formed per 100 kg of fuel is the sum of the masses of all the gaseous components.
Therefore, the mass flow rate of combustion gases is given by,
where,
Mass of ash/soot
Net calorific value of fuel
The net calorific value of fuel is found to be 40.1 MJ kg−1.
Chemical exergy of fuel
For finding the chemical exergy of the fuel, the method explained by Kaushik and Singh [34] has been followed. The ratio of standard specific chemical exergy to the net calorific value for liquid fuels without moisture content is given by [2]
Therefore, the standard specific chemical exergy of the fuel is given by
Using the above relations, the standard specific chemical exergy of fuel is found to be 42.9 MJ kg−1.
Various zones in the boiler
A high-pressure boiler is a very complex assembly of certain components like burners, evaporators, superheaters, economizers, air heaters, and others. The functions of these components are interrelated. Energy and exergy losses in these components are also different. Therefore, for the purpose of accurate analysis and to assess the magnitude and exact location of maximum thermodynamic losses, the entire boiler region has been divided into four zones:
- Zone I:
-
This zone includes the furnace region in which the combustion of fuel is assumed to be adiabatic and at constant pressure
- Zone II:
-
It is the region of medium to high temperature in which evaporator, superheater, and economizer are located. Here, the heat transfer takes place between the hot products of combustion and water
- Zone III:
-
It is the region of comparatively lower temperature in which air preheater is located. Here, the heat transfer takes place between hot gases and air. Pressure remains constant at p0
- Zone IV:
-
This is the region of mixing of the products of combustion with ambient air
Thermodynamic modeling and analysis
Assumptions
-
1.
A steady-state operation of the boiler is considered.
-
2.
The boiler furnace, the evaporator section, and the air preheater section are perfectly insulated from the surroundings so that no heat loss takes place in zones I, II, and III.
-
3.
In zone I, where the furnace is located, the dissociation of the combustion products at high temperature is neglected.
-
4.
The work required by ID and FD fans is neglected.
-
5.
The only loss of heat energy is taking place through the exhaust gases.
-
6.
Pressure drops in pipe lines are neglected.
Zone I
Mass balance
Molar flow rates of the reactants for the given fuel consumption rate and with combustion with 30 % excess air are determined and presented in Table 2.
The mass balance for the control volume (zone I) is given by
or
By applying the mass balance, the molar flow rate of the components of the products of combustion is determined and presented in Table 3.
Energy balance
The energy balance for any combustion process taking place in a control volume is given by
As the reactants are fuel and air, Eq. (16) can be rewritten as
For zone I, there is no heat transfer across the boundary of the control volume and no shaft work is done, i.e., \( \dot{Q}_{\text{CV}} = 0,\;\dot{W}_{\text{s}} = 0 \).
As fuel is supplied at standard temperature (T 0 = 298.15 K) and standard pressure (p 0 = 0.101325 MPa), \( \bar{h}_{{{\text{Ph}},{\text{f}}}} = 0 \)
Therefore, the energy equation becomes
or
Therefore,
As isobaric heat capacity of a gas is a function of temperature, its value will vary as the temperature varies. Therefore, to get accurate result, the above equation is to be solved by iteration. In any iteration, the value of isobaric heat capacity for a particular gas is to be taken corresponding to the value of temperature. We have to keep on doing iterations till the difference between two successive values of temperature is negligibly small.
By iteration procedure, we get
Values of ‘molar isobaric heat capacity for enthalpy’ for different gases at different temperatures are obtained from [2].
Exergy balance
The exergy balance for any control volume is given by
For the zone I, \( \dot{Q}_{\text{CV}} = 0,\;\dot{W}_{\text{s}} = 0 \). The reactants (fuel and air) enter the control volume at inlet, and the products of combustion leave at exit.
Therefore, Eq. (21) can be written as
Therefore, irreversibility rate in zone I is given by
Specific exergy of fuel
Specific exergy of the fuel is the sum of specific physical and chemical exergies,
As fuel is supplied at environmental state (p 0, T 0), its physical exergy is zero, i.e., Ψ Ph, f = 0As T f = T 0 = T 0 = 298.15 K and p f = p 0 = p 0 = 0.101325 MPa, the specific chemical exergy of fuel will be its standard specific chemical exergy, i.e., \( \psi_{{{\text{Ch}},{\text{f}}}} = \psi_{{{\text{Ch}},{\text{f}}}}^{0} \)Therefore,
Specific exergy of air
Molar specific exergy of air at inlet to zone I is the sum of specific physical and chemical exergies
As air consists of reference gases such as N2, O2, and CO2 which are at their partial pressures, its molar specific chemical exergy is zero, i.e., \( \bar{\psi }_{{{\text{Ch}} \cdot {\text{g}}_{2} }} = 0 \)
The molar specific physical exergy of air at inlet to zone I is given by [2]
Since, pressure of air at inlet to zone I, i.e., \( p_{{{\text{g}}_{2} }} = p_{0} = p^{0} = 0.101325\,{\text{MPa}} \), the second term on the right-hand side of Eq. (27) will become zero.
Specific exergy of products of combustion
Molar specific exergy of products of combustion is the sum of specific physical and chemical exergies
The molar specific physical exergy of products of combustion at exit from zone I is given by [2]
Since combustion is taking place at constant pressure p 2 = p 0 = 0.101325 MPa, in Eq. (29), \( \bar{R}T_{0} \ln \left( {\frac{{p_{{{\text{g}}_{3} }} }}{{p_{0} }}} \right) = 0 \).
Values of ‘molar isobaric exergy capacity’ for different gases at different temperatures are obtained from [2].
The molar specific chemical exergy of products is given by [2]
Values of standard molar specific chemical exergy of components of the products of combustion are obtained from [2].
Zone II
Mass balance
The mass balance or equation of continuity for the zone II is given byFor the gas passage,
For the water passage,
Energy balance
The energy balance for the control volume with no chemical reaction is given by
or
or
Since it is purely a physical process and there is no change in chemical composition of the two fluid streams, there will be no change in the enthalpy of devaluation of fluids between inlet and exit, i.e., h d,i = h d,e
Therefore, Eq. (35) becomes
or
For the zone II, \( \dot{Q}_{\text{CV}} = 0,\;\dot{W}_{\text{s}} = 0 \)
From Eqs. (31), (32), and (38), we get
or
or
By iteration procedure, we get
Exergy balance
The exergy balance for any control volume is given by Eq. (21)
For the zone II, \( \dot{Q}_{\text{CV}} = 0,\;\dot{W}_{\text{s}} = 0 \). Therefore, the exergy balance equation for this zone can be written as
or
From Eqs. (31), (32), and (44), we get
Therefore, irreversibility rate in zone II is given by,
Since the process taking place in zone II is purely a physical process and there is no change in chemical composition of the two fluid streams, \( \bar{\psi }_{{{\text{Ch}},{\text{P}}_{2} }} = \bar{\psi }_{{{\text{Ch}},{\text{P}}_{3} }} \) and \( \psi_{{{\text{Ch}},{\text{w}}_{2} }} = \psi_{{{\text{Ch}},\text{s}_{3} }} \).
Therefore,
Equation (29) has been used for finding the molar specific physical exergy of products of combustion at inlet to zone II. The same equation can be used for finding the molar specific physical exergy of products of combustion at exit from zone with a slight change that the temperature in this case is \( T_{{\text{g}_{4} }} \).
Now,
Zone III
Mass balance
The mass balance or equation of continuity for zone III is given byFor the gas passage,
For the air passage,
Energy balance
The energy balance is given by Eq. (36)For the zone III, \( \dot{Q}_{\text{CV}} = 0 \) and \( \dot{W}_{\text{s}} = 0 \).
Therefore,
or
From Eqs. (49), (50), and (52),
or
or
Therefore,
By iteration procedure, we get
Exergy balance
For zone III, \( \dot{Q}_{\text{CV}} = 0 \) and \( \dot{W}_{\text{s}} = 0 \). Therefore, Eq. (43) is applicable for this zone also which can be further written as
From Eqs. (49), (50), and (57),
Therefore, irreversibility rate in zone III is given by,
Since the process taking place in zone III is purely a physical process and there is no change in chemical composition of the two fluid streams, \( \bar{\psi }_{{{\text{Ch}},{\text{P}}_{3} }} = \bar{\psi }_{{{\text{Ch}},{\text{P}}_{4} }} \) and \( \bar{\psi }_{{{\text{Ch}},{\text{a}}_{1} }} = \bar{\psi }_{{{\text{Ch}},{\text{a}}_{2} }} \).
Therefore,
The molar specific physical exergy of products of combustion at inlet and exit from zone III can be calculated by Eq. (29) by using temperatures \( T_{{{\text{g}}_{4} }} \) and \( T_{{{\text{g}}_{5} }} \), respectively.
As air enters zone III at environmental state (p 0, T 0), its physical exergy is zero, i.e., \( \bar{\psi }_{{{\text{Ph}},{\text{g}}_{1} }} = 0 \). The molar specific physical exergy of air at exit from zone III can be calculated by Eq. (27).
Zone IV
In this zone, all the exergy of gases given by \( \dot{X}_{{{\text{g}}_{5} }} \) is lost through dissipation (mixing, cooling, etc.).
Hence, irreversibility rate in zone IV is given by,
Therefore, total irreversibility rate in the boiler is given by,
Energy and exergy efficiencies of the boiler
Energy efficiency of the boiler is given by
Since the function of the boiler is to increase the exergy of the stream of water by taking exergy of the fuel as input, its exergy efficiency is given by
Results and discussion
The considered boiler was analyzed considering the environmental temperature and pressure of 298.15 K and 100.8 kPa, respectively, as reference conditions. The results of the exergy analyses are summarized in Table 4.
The only loss of heat energy has been assumed to be taking place through the exhaust gases. The energy efficiency of the boiler under consideration is (94.81 %). This efficiency is based on the lower heating value (LHV) of the fuel which assumes that the water vapor formed during combustion leaves as vapor itself so that it takes into account the losses occurring in the boiler furnace due to moisture present in the fuel. The energy analysis reveals that maximum combustion energy of the fuel is lost in zone IV of the boiler and taken away by the exhaust gases. So, from the point of view of energy analysis, the major loss of energy occurs in zone IV.
Energy efficiency and the energy losses are based on the first law of thermodynamics and do not provide a true picture of the processes taking place in the boiler. This analysis also does not tell anything about the quality of energy going waste along with the exhaust gases. Actually, the loss of energy through exhaust gases is thermodynamically insignificant due to its low quality. Moreover, this loss cannot be avoided completely as the flue gases are to be discharged into the atmosphere at higher temperature to remain above dew point temperature to prevent acid corrosion problems and for proper dispersion of exhaust gases into the atmosphere [35].
The exergy analyses of different zones of the boiler have been carried out at reference environmental condition of T o = 298.15 K and p o = 100.8 kPa. The exergy efficiency of the boiler under consideration is found to be 43.93 %. The irreversibility rates in various zones and exergy efficiency of the boiler expressed as percent of fuel exergy input are presented in Table 4 and are illustrated in the bar diagram in Fig. 2. The exergy flow and irreversibility rates in different zones are shown in the Grassmann diagram in Fig. 3. It is found that the irreversibility rate in the zone I is the highest as compared to that in other zones. In this zone, 29.26 % of fuel exergy is destroyed, while the energy loss is zero. In zone II, the exergy destruction is 21.58 %. In the chimney zone, where the energy loss is the maximum, the exergy destruction is just 4.64 %. Therefore, the real loss is actually taking place in the boiler furnace due to the generation of entropy. The chemical reactions between the fuel and the air are the main cause of irreversibility. The performance of the boiler can, therefore, be improved by reducing the thermodynamic irreversibility in the furnace and in the vaporization zone.
Conclusions
Fossil fuel resources are being depleted quickly due to increasing energy demand. Therefore, there is a need to use these resources judiciously to extend their life. This is possible by improving the efficiency of fuel-burning systems. Moreover, the pollution hazard arising out of fossil fuel burning has also necessitated the improvement in the efficiency of these systems. In view of this, the designers of the boilers and energy experts should consider the second law or exergy analysis in designing this equipment. This analysis enables one to evaluate quantitatively the causes of thermodynamic irreversibilities of thermal and chemical processes. Poor thermodynamic performance is the results of exergy destructions in combustion and heat-transfer processes. In the present work, the method for the calculation of chemical exergy of heavy fuel oil and the method of carrying out exergy analysis of a boiler have been presented.
In the boiler under consideration, the maximum energy loss was found in the zone IV, while maximum destruction of fuel exergy was found in the zone I (29.26 %) followed by zone II (21.58 %) where the heat energy loss has been assumed to be zero. So, the real loss is taking place in zone I. Therefore, based on the exergy analysis, it can be concluded that the components that should be considered for improvement in the plant are the boiler furnace and the evaporator section. Furnace, being the major source of irreversibility, has the largest improvement potential as compared to other components of the boiler. The evaporator section being the second largest destroyer of exergy also needs careful attention. The chemical reaction between air and fuel in the combustion process is the main source of irreversibility in the boiler furnace. Decreasing the temperature difference between the reactants and the products will cause the irreversibility rate in the boiler furnace to decrease. This can be achieved by decreasing the percentage of excess combustion air and increasing the inlet air temperature further by utilizing the exhaust heat further.
It would be worthwhile to note that the methods and the work presented herein will prove to be useful to the analysts and researchers not only in conducting the exergy analysis of any other boiler but also helping in analyzing other combustion systems as well.
Abbreviations
- \( \bar{C}_{\text{p}}^{\text{h}} \) :
-
Mean molar isobaric heat capacity for enthalpy of a gas/kJ kmol−1 K−1
- \( \bar{C}_{\text{p}}^{\psi } \) :
-
Mean molar isobaric exergy capacity of a gas/kJ kmol−1 K−1
- FD:
-
Forced draft
- g 1, g 2 …g 6 :
-
Nodal points in air and gas passage
- h :
-
Specific enthalpy/kJ kg−1
- \( h_{\text{Ph}} \) :
-
Specific physical enthalpy/kJ kg−1
- \( h_{\text{d}} \) :
-
Specific enthalpy of devaluation/kJ kg−1
- \( \bar{h}_{\text{Ph}} \) :
-
Molar specific physical enthalpy/kJ kmol−1
- H :
-
Enthalpy/kJ
- ID:
-
Induced draft
- \( \dot{I} \) :
-
Irreversibility rate/kW
- \( \bar{h}_{\text{d}}^{0} \) :
-
Standard molar specific enthalpy of devaluation/kJ kmol−1
- m :
-
Mass of a component in 100 kg mass of fuel/kg
- M :
-
Molecular mass
- \( \dot{m} \) :
-
Mass flow rate/kg s−1
- n :
-
Number of kmols of a component in 100 kg mass of fuel
- \( \dot{n} \) :
-
Molar flow rate/kmol s−1
- \( \left( {\text{NCV}} \right)^{0} \) :
-
Net calorific value of fuel/kJ kg−1
- \( p \) :
-
Absolute pressure/Pa
- \( \dot{Q} \) :
-
Heat-transfer rate/kW
- \( \bar{R} \) :
-
Universal gas constant (=8.31451 kJ kmol−1 K−1)
- s :
-
Specific entropy/kJ kg−1 K−1
- \( T \) :
-
Absolute temperature/K
- w 1, w 2 :
-
Nodal points in the water and steam passage
- \( \dot{W}_{\text{s}} \) :
-
Shaft work done rate/kW
- x :
-
Mole fraction
- \( \dot{X} \) :
-
Exergy flow rate/kW
- \( \psi \) :
-
Specific exergy/kJ kg−1
- \( \psi_{\text{Ph}} \) :
-
Specific physical exergy/kJ kg−1
- \( \psi_{\text{Ch}} \) :
-
Specific chemical exergy/kJ kg−1
- \( \bar{\psi } \) :
-
Molar specific exergy/kJ kmol−1
- \( \bar{\psi }_{\text{Ph}} \) :
-
Molar specific physical exergy/kJ kmol−1
- \( \bar{\psi }_{\text{Ch}} \) :
-
Molar specific chemical exergy/kJ kmol−1
- \( \psi_{\text{Ch}}^{0} \) :
-
Standard specific chemical exergy/kJ kg−1
- ∆:
-
Used for a change in any parameter
- a :
-
Air
- CV:
-
Control volume
- d :
-
Devaluation
- e :
-
Exit
- f :
-
Fuel
- g :
-
Gas
- g 1, g 2 …g 6 :
-
For the nodal points in air and gas passage
- i :
-
Inlet
- j :
-
A component
- P :
-
Product
- R :
-
Reactant
- w 1, w 2 :
-
For the nodal points in the water and steam passage
- 0:
-
For environmental state
- I, II, III, and IV:
-
Zones in the boiler
- 0:
-
For standard state
References
Singh OK, Panwar NL. Effects of thermal conductivity and geometry of materials on the temperature variation in packed bed solar air heater. J Therm Anal Calorim. 2013;111:839–47.
Kotas TJ. The exergy method of thermal plant analysis. London: Butterworths; 1985.
Sonntag RE, Borgnakke C, Van Wylen GJ. Fundamentals of classical thermodynamics. New York: Wiley; 2000.
Gaggioli RA, Petit PJ. Use the second law first. ChemTech. 1977;7:496–506.
Ahern JE. The exergy method of energy system analysis. New York: Wiley; 1980.
Szargut J, Morris DR, Steward FR. Exergy analysis of thermal, chemical, and metallurgical processes. New York: Hemisphere; 1988.
Moran MJ. Availability analysis: a guide to efficient energy use. New York: ASME Press; 1989.
Moran MJ, Sciubba E. Exergy analysis: principles and practice. J Eng Gas Turbines Power. 1994;116:285–90.
Bejan A. Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architecture. Int J Energy Res. 2002;26:545–65.
Moran MJ, Shapiro HN. Fundamentals of engineering thermodynamics. 5th ed. New York: Wiley; 2003.
Szargut J. Exergy method: technical and ecological applications. Southampton: WIT Press; 2005.
Dincer I, Rosen MA. Exergy: energy, environment and sustainable development. Oxford: Elsevier; 2007.
Nag PK, De S. Design and operation of a heat recovery steam generator with minimum irreversibility. Appl Therm Eng. 1997;17:385–91.
Dincer I, Al-Muslim H. Thermodynamic analysis of reheat cycle steam power plants. Int J Energy Res. 2001;25:727–39.
Sengupta S, Datta A, Duttagupta S. Exergy analysis of a coal-based 210 MW thermal power plant. Int J Energy Res. 2007;31:14–28.
Kopac M, Hilalci A. Effect of ambient temperature on the efficiency of the regenerative and reheat Catalağzı power plant in Turkey. Appl Therm Eng. 2007;27:1377–85.
Aljundi IH. Energy and exergy analysis of a steam power plant in Jordan. Appl Therm Eng. 2009;29:324–8.
Teerawat S, Adisorn A. Simulation and optimization of coal-fired power plants. Energy Proced. 2009;1:3851–8.
Guo X, Yang Y. Thermodynamic models and energy distribution of single-phase heated surface in a boiler under unsteady conditions. Front Energy. 2011;5(1):69–74.
Singh OK, Kaushik SC. Variables influencing the exergy based performance of a Steam Power Plant. Int J Green Energy. 2013;10:257–84.
Khaliq A, Kaushik SC. Second-law based thermodynamic analysis of Brayton/Rankine combined power cycle with reheat. Appl Energy. 2004;78(2):179–97.
Sanjay Y, Singh O, Prasad BN. Energy and exergy analysis of steam cooled reheat gas–steam combined cycle. Appl Therm Eng. 2007;27:2779–90.
Kalina AI. Combined cycle system with novel bottoming cycle. ASME J Eng Gas Turbines Power. 1984;106:737–42.
Singh OK, Kaushik SC. Energy and exergy analysis and optimization of kalina cycle coupled with a coal fired steam power plant. Appl Therm Eng. 2013;51(1–2):787–800.
Singh OK, Kaushik SC. Reducing CO2 emission and improving exergy based performance of natural gas fired combined cycle power plants by coupling Kalina cycle. Energy. 2013;55:1002–13.
Zheng D, Chen B, Qi Y, Jin H. Thermodynamic analysis of a novel absorption power/cooling combined-cycle. Appl Energy. 2006;83:311–23.
Wang J, Dai Y, Gao L. Exergy analyses and parametric optimizations for different cogeneration power plants in cement industry. Appl Energy. 2009;86:941–8.
Ozgener O, Hepbasli A. Exergoeconomic analysis of a solar assisted ground-source heat pump greenhouse heating system. Appl Therm Eng. 2005;25:1459–71.
Gang P, Jing L, Jie J. Analysis of low temperature solar thermal electric generation using regenerative Organic Rankine Cycle. Appl Therm Eng. 2010;30:998–1004.
Pandey AK, Tyagi VV, Park SR, Tyagi SK. Comparative experimental study of solar cookers using exergy analysis. J Therm Anal Calorim. 2012;109:425–31.
Kaushik SC, Panwar NL, Reddy VS. Thermodynamic evaluation of heat recovery through a Canopus heat exchanger for vapor compression refrigeration (VCR) system. J Therm Anal Calorim. 2012;110:1493–9.
Saravanakumar R, Selladurai V. Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a. J Therm Anal Calorim. 2014;115:933–40.
Chamoli S, Thakur NS. Exergetic performance evaluation of solar air heater having V-down perforated baffles on the absorber plate. J Therm Anal Calorim. 2014;117:909–23.
Kaushik SC, Singh OK. Estimation of chemical exergy of solid, liquid and gaseous fuels used in thermal power plants. J Therm Anal Calorim. 2014;115:903–8.
Nag PK. Power plant engineering. New Delhi: Tata McGraw-Hill Publishing Company Limited; 2007.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Singh, O.K. Assessment of thermodynamic irreversibility in different zones of a heavy fuel oil fired high pressure boiler. J Therm Anal Calorim 123, 829–840 (2016). https://doi.org/10.1007/s10973-015-4959-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10973-015-4959-4