Introduction

Gluten detection is an outstanding problem because of its relation with coeliac disease (CD) and gluten-related allergies or intolerances. CD is one of the most prevalent autoimmune diseases affecting 1 % of population and is related to genetic factors and triggered by the ingestion of gluten [1]. The only treatment for CD is the strict following of a lifelong gluten-free diet. Because of the seriousness of the CD and its prevalence, EU legislation enforces the labelling of food that may contain gluten-containing cereals and allows to label as gluten-free products those containing less than 20 ppm of gluten [2]. However, there is no universal agreement on what the term gluten free means. For example, Spanish Federation of CD Patients Associations (FACE) establishes a gluten-free certification, which assures that the product contains less than 10 ppm of gluten. However, there are especially sensitive patients who can develop symptomatology after the ingestion of minimal amounts of gluten that makes those limits insufficient. The lowering of the existent limits is being frustrated by the need for more sensitive and reliable gluten detection methods to be applied in the food industry.

The development of gluten detection methods has to confront some challenges because of the nature of the analytical problem. The first one is the lack of a clearly defined chemical target, as gluten is the popular name given to major storage proteins of certain dietary grains. Gliadins, the alcohol-soluble fraction of wheat gluten, and homologous proteins in barley, rye and possibly oats, globally termed as prolamins, are the main target in gluten analysis. Additionally, during food processing, the proteins composing gluten may suffer alterations induced by thermal or enzymatic treatments. Gluten proteins have a relatively large amount of –SH-containing amino acids. These residues form intrachain S–S bonds that suffer different changes depending on the thermal food processing. Breaking of the S–S intrachain bonds and formation of new ones between different chains originates a polymeric structure with low solubility, avoiding quantitative extraction of the proteins and affecting its further analysis [3]. The most common sample treatment involves extraction of gluten prolamins using a 60 % ethanol solution. This extraction is not capable of fully dissolving gluten in heat-processed foods [4]. In order to overcome this problem, different extraction solutions have been developed, incorporating a reducing reagent, for breaking interchain S–S bonds, and chaotropic agents, to solubilise gluten proteins in the extraction solution [4, 5]. The most used extraction mixture, called ‘cocktail’, is composed of 2-mercaptoethanol and guanidine hydrochloride [5]. Another important alteration of the proteins occurs when food processing involves treatments in which gluten can be hydrolysed. In the production of starch and syrup and in brewery, enzymatic processing breaks down the proteins into small peptides that are also toxic for CD patients [68]. These immunotoxic small peptides must also be detected to estimate the toxicity of these products for coeliac patients.

Enzyme-linked immunosorbent assays (ELISAs) are the currently accepted methods for gluten determination in foods. Several antibodies targeting different fragments of gluten proteins are employed [912]. Despite their many positive characteristics, the traditional sandwich ELISA is not suitable for quantifying gluten in hydrolysed foods because it requires the presence of at least two epitopes in the target molecule, which is unlikely in the fragments obtained after hydrolysis. To overcome this drawback, competitive immunoassays have been developed based on the R5 antibody and using as calibration standard gliadin [4] or a mixture of whole protein and hydrolysed fragments [13] or on the G12 antibody and tracing the calibration curve using whole gliadin [11]. However, neither the sandwich assays nor the competitive ones are fully compatible with the cocktail extraction solution because their components may denature the protein receptor [14]. A non-protein receptor for gliadin would thus contribute to the improvement of gluten detection methods.

With the aim of solving this problem, we have recently obtained a panel of aptamers for specific binding to gliadin [15]. These non-protein receptors, obtained against one of the main immunogenic gluten peptides known as 33-mer [7], are able to bind not only the peptide used as a target for selection but also the whole protein and homologous ones in rye, barley and oats, suggesting that they might serve as viable receptors for the detection of gluten in foods at concentrations below the 20 ppm threshold proposed by the Codex Alimentarius Commission. Here, we expand this approach developing and validating two electrochemical competitive assays on magnetic particles for the determination of gluten. These assays rely on the use of two of the selected aptamers, i.e. Gli 4, the ligand with the highest affinity towards gliadin, and Gli 1 the most abundant in the selection pool, whose binding to the peptide may be kinetically favoured. Their analytical performance is comparatively evaluated and validated against gliadin-ELISA kits. Both assays are complementary, proving to be reliable tools for sensitive detection of gluten in a wide variety of foods, including heat-treated and hydrolysed ones.

Materials and methods

Reagents

DNA aptamers (5′→3′), both labelled in 5′ with biotin, Gli 4: (CCAGTCTCCCGTTTACCGCGCCTACACATGTCTGAATGCC) and Gli 1: (CTAGGCGAAATATAGCTACAACTGTCTGAAGGCACCCAAT), were obtained from Integrated DNA Technologies (IDT, Leuven, Belgium).

Unmodified (LQLQPFPQPQLPYPQPQLPYPQPQLPYPQPQPF; 33-mer) and biotinylated (LQLQPFPQPQLPYPQPQLPYPQPQLPYPQPQPFHHHHHH-lysine-biotin; biotin-33-mer) peptides and QQPFP were purchased from Biomedal (Sevilla, Spain).

Streptavidin modified magnetic beads with a binding capacity of 4 nmol mL−1 of free biotin (Dynabeads® MyOne™ streptavidin C1, 1 μm Φ, 10 mg mL−1) were provided by Life Technologies (Madrid, Spain). Gliadin standard solutions were prepared using the gliadin standard provided by the Working Group on Prolamin Analysis (PWG) and acquired to R-Biopharm. Streptavidin-peroxidase conjugate (Str-HRP2, 176 units mg−1 peroxidase activity) was obtained from Thermo Fisher (Madrid, Spain). Reagents for buffer preparation, guanidinium hydrochloride, mercaptoethanol, polyvinylpyrrolidone, fish gelatine and enzymatic substrate 3,3′,5,5′-tetramethylbenzidine (TMB) liquid substrate system for ELISA were purchased from Sigma-Aldrich. Solutions were prepared using Milli-Q purified water.

Procedures

Modification of streptavidin-coated magnetic beads

An aliquot of 50 μL of the streptavidin-magnetic bead stock solution was washed twice with BLmod (1 mL phosphate-buffered saline (PBS) + 0.01 % Tween 20) for 2 min and then resuspended in 1 mL of 2 μM biotinylated 33-mer in BLmod. The tube was incubated for 30 min at 30 °C in a Thermomixer (Eppendorf Ibérica, Spain) under continuous shaking. After that, the beads were washed twice in BLmod and blocked with 500 μM biotin in BLmod for 30 min. After two new washing steps, they were reconstituted in 500 μL binding solution (BS) (50 mM Tris (pH 7.4) + 0.25 M NaCl + 5 mM MgCl2) and used within the same day.

Competitive assay

For Gli 1 assay, 30 μL of modified magnetic beads was incubated in 500 μL of BS with 250 nM of the biotinylated aptamer and selected amounts of calibration standard (or 10 μL of the extracted sample) for 30 min at 30 °C in a Thermomixer under shaking. After that, the beads were washed twice with BS solution containing 0.01 % Tween 20 (BST) and incubated with an excess of enzymatic conjugate (2.5 μg mL−1 Str-HRP2) in 500 μL of BST for 30 min at 30 °C under shaking. Finally, the beads were washed twice with BST and once with BS and resuspended in 30 μL of BS.

For Gli 4 assay, 10 μL of modified magnetic beads was incubated in 1 mL of BS with 250 nM of the biotinylated aptamer and selected amounts of calibration standard (or 20 μL of the extracted sample) for 30 min at 30 °C in a Thermomixer under shaking. After that, the beads were washed twice with BST and incubated with an excess of enzymatic conjugate (2.5 μg mL−1 Str-HRP2) in 1 mL of BST for 30 min at 30 °C under shaking. Finally, the beads were washed twice with BST and once with BS and resuspended in 10 μL of BS.

Amperometric measurement

The resuspended beads (10 μL) were captured on screen-printed carbon electrodes (DropSens, Oviedo, Spain) placing a magnet under the working electrode, and the electrochemical cell was covered with 40 μL of 3,3′,5,5′-tetramethylbenzidine + H2O2 substrate. The enzymatic reaction was developed for 30 s, and the enzymatically obtained product was measured by chronoamperometry at 0 V using a μAutoLab type II potentiostat (Eco Chemie, The Netherlands).

Extractions

For the extraction of flours and no heat-processed foods, 0.8 g of flour or homogenised food sample was placed in a 15-mL Falcon tube and washed with an aqueous solution of 2 M NaCl. After 20 min of shaking at room temperature (RT), the tube was centrifuged in a Heraeus Multifuge 1 L-R (Thermo Scientific) for 15 min at 7500g and the supernatant was discarded. Prolamins were extracted twice with 60 % ethanol solution. For this purpose, 4 mL of ethanol solution was added to the tube and the mixture was incubated at RT during 20 min and then centrifuged for 15 min at 7500g, and both supernatants were combined.

Some food samples were also extracted as follows: 0.25 g of the ground sample was mixed with 2 mL of cocktail solution (250 mM mercaptoethanol, 2 mM guanidine in 0.1× PBS). The suspension was incubated in an oven at 50 °C for 40 min. Once at room temperature, 3 mL of ethanol was added and extraction in a shaker was extended for 1 h. Finally, the samples were centrifuged at 2500g for 30 min and the supernatant was used in the analysis. The sample containing chocolate was extracted in the presence of 0.25 g of gelatin and 0.1 g of polyvinylpyrrolidone, which were added to 0.25 g of the ground sample before the extraction.

Results and discussion

We chose a competitive assay format, well suited to detect both intact protein and small protein fragments, using two previously selected aptamers targeting the immunotoxic α2-gliadin fragment, 33-mer [15]. Magnetic microparticles are employed as support for the sensing phase to take advantage of the efficient magnetic separation offered by this platform, which facilitates subsequent exhaustive washing steps, thus minimising major problems associated with non-specific interactions. The preparation of the sensing phase is very simple. A commercially available 33-mer, modified at its carboxy-terminus with a biotin, is immobilised onto the surface of streptavidin-modified magnetic particles, and then, the unoccupied sites of streptavidin are blocked with biotin. The analytical assay we developed using this platform comprises the following steps (Fig. 1): first, the sample and the biotin-labelled aptamer are incubated with a fixed amount of the modified magnetic beads. In this step, the analyte from the test solution competes with the immobilised peptide for a limited amount of the aptamer. As a result, part of the biotin-aptamer is specifically captured and separated from the sample after applying an external magnetic field. In order to detect the bound aptamer, particles are incubated in a second step with a streptavidin-peroxidase conjugate containing two molecules of enzyme per streptavidin as a reporter molecule. Finally, the enzyme activity on the surface is electrochemically quantified by magnetically entrapping the modified beads onto a screen-printed carbon electrode. After the addition of tetramethylbenzidine and hydrogen peroxide, we measured by chronoamperometry the reduction of the product enzymatically produced. The higher the concentration of gliadin in the sample, the lower is the reduction current we obtain.

Fig. 1
figure 1

Schematic representation of the competitive aptamer-based assay for gliadin determination

Assay optimization

To obtain optimal conditions for the competitive assay, the concentration of biotin-aptamer was first selected, fixing the amount of magnetic particles modified with the peptide in 0.06 mg mL−1. In this study, different concentrations of the aptamers in the range 0.5 nM–2 μM were tested without protein or peptide in solution. This analysis produces typical binding curves for both aptamers (Fig. 2). Two hundred fifty nanomolar of the aptamer, the concentration that yield around 50 % of the maximum obtained signal, was selected for competition. In the absence of the aptamers, we observe only a small reduction current (0.4 ± 0.1 μA), which confirmed that the contribution of the non-specific interaction of Str-HRP2 conjugate is not significant. The assay also gives negligible responses when it is performed using a randomised biotinylated DNA library at a 250 nM concentration level. Conversely, we registered a maximum signal value of 4.7 ± 0.1 and 3.6 ± 0.1 μA for Gli 4 and Gli 1, respectively, at this aptamer concentration. These results are consistent with the specific interaction of both aptamers with the immobilised peptide and a higher affinity for the Gli 4 aptamer [15].

Fig. 2
figure 2

Binding curves of aptamers Gli 4 (filled circle, dashed line) and Gli 1 (empty square, solid line) to 33-mer peptide immobilised onto magnetic beads through biotin-streptavidin interaction

The second variable we took into consideration is the composition of the competition buffer. To evaluate the effect of ethanol in the aptamer/peptide interaction, we performed the competitive assay in a buffer containing different concentrations of this alcohol. The presence of 1.2 % of ethanol, which will correspond to a 1:50 dilution of samples extracted using 60 % ethanol, increases the maximum signal obtained while the blank is not affected. The improved signal amplitude at 1.2 % ethanol can be explained, given the apolar nature of the peptide modifying the surface of the beads, which may cause their slight aggregation. A small amount of ethanol may act as a disaggregating agent, favouring the aptamer/peptide interaction. Consistent with this, the competitive assay achieves improved signal decrease with this amount of ethanol in the buffer. At 3 % of ethanol, the binding of Gli 1 to the peptide decreases to about 35 % of the maximum, while Gli 4 interaction is less affected, which again is in agreement with the lower affinity constant for the peptide-Gli 1 reaction.

Therefore, the best performance in terms of sensitivity is obtained, employing 0.06 mg mL−1 of the modified beads and 250 nM of the aptamer, in the presence of 1.2 % ethanol. Upon the addition of 10 μg L−1 of PWG standard to the competition buffer in the presence of Gli 1, 13 % of signal decrease is observed with a coefficient of variation of 6 %. Under the same conditions, Gli 4 gives rise to higher sensitivity with about 20 % of decrease at the same concentration of PWG. We find, however, that this aptamer leads to worse reproducibility, more than 15 % of relative standard deviation (RSD) at 10 μg L−1, probably related to the fact that a higher tendency of the 33-mer-modified magnetic particles to aggregate is observed with this aptamer. To overcome this difficulty, we performed the competitive assay with Gli 4 using a higher dilution of the magnetic beads during the competition, i.e. 0.01 mg mL−1, while maintaining the amount of beads on the electrode surface for measurement (10 μg). In this way, the sensitivity of the assay was not affected and precision was improved, with a RSD of 6 % for 10 μg L−1 of PWG.

Analytical performance

The performance of both aptamers in competitive assays under the optimum conditions was compared using PWG gliadin or 33-mer peptide as standards. The selection of the standard for calibration has to be carefully done to avoid deviations in the value obtained. The most used calibration and validation standard is PWG gliadin, a material obtained after processing of 28 different cultivars of wheat [16]. We used this material as a gliadin standard to obtain the calibration curve.

In Fig. 3a, the current intensities obtained after challenging the modified beads with increasing concentrations of PWG using both aptamers is depicted. As expected, the Gli 4 aptamer gives rise to higher currents than the Gli 1 aptamer as a result of the difference in affinity.

Fig. 3
figure 3

Calibration curves for the competitive assay (a) using Gli 4 (filled circle, dashed line) and Gli 1 (empty square, solid line) aptamers with PWG gliadin as a standard and (b) using the Gli 1 aptamer with PWG gliadin (empty square, solid line) and 33-mer peptide (filled circle, dashed line) as standards

Data were fitted to a four-parameter logistic (Eq. 1)

$$ y=A+\frac{\left(B-A\right)}{1+{\left(\frac{x}{{\mathrm{EC}}_{50}}\right)}^p} $$
(1)

where A is the response at an infinite concentration of analyte, B is the response at a zero concentration of analyte, EC50 is the concentration of analyte that corresponds to the 50 % of the maximum signal, and p is the Hill slope that represents the slope at the inflexion point of the sigmoidal curve. Due to the low solubility of gliadin in aqueous solution, concentrations higher than 1 μg L−1 were not assayed, which precluded the observation of the complete sigmoidal curve. The best fitting was obtained, fixing parameter A to zero, and the equations are the following:

$$ \begin{array}{l}I\left(\mu A\right) = (3.60)/\left(1+{\left(\left.\left[\mathrm{P}\mathrm{W}\mathrm{G}\ \left({\upmu \mathrm{g}\ \mathrm{L}}^{-1}\right)\right]\right)/721\right)}^{0.5}\right);\ r=0.980\ \mathrm{f}\mathrm{o}\mathrm{r}\ \mathrm{G}\mathrm{l}\mathrm{i}\ 1\kern0.24em \mathrm{and}\hfill \\ {}I\left(\mu A\right)=(5.17)/\left(1+{\left(\left[\mathrm{P}\mathrm{W}\mathrm{G}\ \left({\upmu \mathrm{g}\ \mathrm{L}}^{-1}\right)\right]/273\right)}^{0.6}\right);\ r=0.997\ \mathrm{f}\mathrm{o}\mathrm{r}\ \mathrm{G}\mathrm{l}\mathrm{i}\ 4.\hfill \end{array} $$

The limit of detection of each assay was calculated as the concentration that gives the 95 % of the maximum signal and corresponds to 4.9 μg L−1 of gliadin when using Gli 1 as a recognition element and 0.5 μg L−1 of gliadin when using Gli 4. Taking into account the sample extraction, the dilution of the extract and the gliadin-to-gluten ratio, the limit of detection in the real samples can be calculated in order to verify whether the methods meet the requirements to evaluate the accomplishment of the EU legislation. The overall sample dilution is 1:500, and the content of gliadin in gluten is considered as 50 % [17], though the values ranging from 32 to 67 % have been found [18]; so, the limit of detection expressed in gluten for each assay is 4.9 and 0.5 ppm for Gli 1 and Gli 4, respectively. Those values are below the limits needed to check the legislation accomplishment and are similar or slightly lower than competitive immunoassays even those currently marketed [4, 11, 1921].

The repeatability of the assays calculated as the coefficient of variation at 1 and 10 μg L−1 of gliadin concentration were 7 and 8 %, respectively, for the Gli 1 aptamer and 9 and 6 %, respectively, for Gli 4. The inter-assay reproducibility, calculated with the signal obtained for 10 μg L−1 in three different days is 9.5 % for Gli 1 assay and 6 % for Gli 4 assay.

Competitive assays are specifically designed for the hydrolysed samples where the proteins are digested to small peptides containing a single epitope for the antibody. The competitive format of R5 antibody uses a peptide fragment (QQPFP) as a standard even though the equivalence between peptide fragments and the intact protein is lacking [13]. This precludes the conversion of the results into gluten content as required in the legislation [17]. On the contrary, the competitive G12 assay uses the intact protein [11]. We have previously found a correlation between Sigma gliadin and 33-mer using G12 antibody in an electrochemical competitive immunoassay [20]. Therefore, the feasibility of using 33-mer peptide as a standard for the competitive apta assay was studied. In Fig. 3b, the response of Gli 1-based method to increasing concentrations of 33-mer is shown and compared with the calibration plot using PWG both expressed in nanomolar. It is apparent that the aptamer recognises the peptide, but at much larger concentrations than the intact protein, which indicates that PWG contains several binding sites in its structure. However, the number of those ‘aptatopes’ would be very high, about 200, which seems unrealistic. In our previous work, two binding sites for antibody G12 were found in each gliadin standard, which is reasonable. Recently, we have found that Gli 1 exhibits positive cooperativity when binding to PWG, which can explain the apparent higher affinity towards the intact protein even taking into consideration the presence of several binding sites [22].

On the contrary, proper calibration plots using the Gli 4 aptamer as a recognition element and the 33-mer peptide as a standard were not obtained. This fact is attributed to microscopic aggregation of the beads in the presence of this aptamer. Therefore, the Gli 1 aptamer was selected as the receptor for subsequent testing of hydrolysed samples.

The response of Gli 1 aptamer to the recognition epitope of the official R5 method, that is, the pentapeptide QQPFP [23], was also tested. This specific sequence is not present in the immunodominant 33-mer peptide used for aptamer selection, but it is present in wheat, rye and barley prolamins. The aptamer was able to recognise this peptide, but at much higher concentrations than 33-mer (above 1 μM), which suggests a much lower affinity accordingly to its absence in the selection target.

Cross-reactivity against other cereals and grains

Not only wheat proteins are toxic for coeliac disease patients; prolamins from barley and rye have almost the same toxicity. However, the toxicity of oat for coeliac patients is still controversial [24, 25 and citation therein], so oat prolamins also have to be evaluated towards the quantification of the toxicity in food products. For this reason, it is necessary to evaluate the response of the competitive assays using Gli 1 and Gli 4 aptamers against prolamins from other toxic cereals and the selectivity against non-CD-triggering cereals and grains. Because of the unavailability of prolamin standards or reference materials from other grains, the ethanol-soluble fraction was extracted from each grain flour. After the extraction, the total protein present in the solution was quantified using the Bradford method and PWG as standard, obtaining a content in prolamin for each extract as follows: wheat 5.4 mg mL−1, rye 4.6 mg mL−1, barley 5.2 mg mL−1 and oat 4.7 mg mL−1. All the extracts were diluted at different levels to obtain the desired protein concentration in the competition buffer. As it can be seen in Fig. 4, both assays with Gli 1 and Gli 4 recognise gliadins (wheat), hordeins (barley) and secalins (rye) in a similar extension within the experimental error. However, the response to avenins (oat) is different. The Gli 1 aptamer is not able to bind oat proteins, while the Gli 4 aptamer recognises avenins, but with less affinity than the rest of prolamins from CD-toxic cereals. This result is interesting because the antibodies G12 and A1, which are also raised against the 33-mer peptide, weakly bind to avenins, although 33-mer is not present in their sequence [26]. The sensitivity order to prolamins was, however, different: hordeins ≈ gliadins > secalins > > avenin for G12 and hordeins ≈ rye > gliadin > > avenins for the aptamers. In our case, differences between hordeins, gliadins and secalins are less pronounced in both cases. The official R5 method does not respond to the controversial oat prolamins [10].

Fig. 4
figure 4

Response of the competitive assay expressed as a percentage of the maximum signal obtained in the absence of protein to different toxic prolamins from wheat (filled diamond, red line), rye (filled square, blue line), barley (filled circle, green line) and oats (empty square, black line) using Gli 1 (a) and Gli 4 (b) aptamers

It is also important to ensure the non-response of the developed method against proteins from non-toxic flours such as soya, maize and rice often used as substitutes of toxic cereals to elaborate CD-safe food. To evaluate the cross-reactivity, the response to increasing concentrations of proteins extracted from soya, maize and rice flours was assayed. In all the concentration ranges, the analytical responses expressed as the current percentage of the maximum current obtained in the absence of protein were around 100 %. Specifically, percentages obtained with Gli 1 assay were as follows: soya 112 ± 11 %, maize 135 ± 26 % and rice 112 ± 9 %. For the Gli 4 assay, these were as follows: soya 125 ± 37 %, maize 121 ± 36 % and rice 113 ± 25 %. According to this, aptamers do not cross react with non-toxic proteins.

Application of the competitive assays to food samples

The competitive methods developed are sensitive and selective enough to be applied to gluten determination in gluten-free labelled foods in order to evaluate the compliance with the law and to provide more information to the consumer. To do this, we tested the samples provided by two external laboratories. All of them had unknown gluten content. The samples provided by laboratory I were divided, according to the information given by the company, in two groups: non-hydrolysed samples (Table 1) to be quantified using the Gli 4 assay that is more sensitive, and hydrolysed samples (Table 2) to be quantified using the Gli 1 assay, the peptide-responsive one. The liquid samples were just diluted with 60 % ethanol, and the solid samples were extracted with the conventional extraction procedure using 60 % ethanol, which is the method recommended by the commercial kit based on G12, the antibody used by the company for comparison. The samples are considered positive when the gluten content is above the limit of quantification of the method used in each case, even in cases where the samples meet gluten-free specifications (less than 20 ppm gluten).

Table 1 Samples extracted with ethanol 60 % and analysed with Gli 4 aptamer. They were compared with a G12 method carried out by the external laboratory
Table 2 Analysis of liquid hydrolysed samples using the Gli 1-based competitive method and comparison with the values provided by the external laboratory

The samples identified as positive with the reference methods are, in general, positive with our method. There are two apparent exceptions, both liquid non-hydrolysed samples (liquids C and H). These are gluten-free samples that were spiked with gluten by the external laboratory in a blind assay. The recovery values we found for these samples are close to 100 % even in the case of sample C, spiked with a gluten concentration very near to the limit of quantification of our method. So, we can conclude that our method does not present false-negative results. Only one out of the five liquid non-hydrolysed samples analysed (liquid A) was negative by the G12 immunoassay. In this sample, our method detected gluten, but with a content below the 20 ppm threshold level. This difference may be due to the improved sensitivity of our method with respect to G12. Gliadin levels measured in the solid non-hydrolysed samples were comparable with levels detected using the G12 assay in 50 % of the samples (three out of six). Both methods showed non-detectable gluten in a rice sample. In general, our method detects higher gluten content than did the G12 kit. Interestingly, the three discordant samples are negative by the G12 assay and positive by our method. These differences can be explained by variations in the extracted target compounds detected using the two assays.

Attending to the results for hydrolysed samples (Gli 1 assay, Table 2), there is a good correlation between the results provided by the external analysis and those obtained using the competitive assay developed in this work. This correlation demonstrates the applicability of the competitive assay based on the Gli 1 aptamer to quantify gluten in the hydrolysed samples. Only a false-positive result was obtained, corresponding to a sample of a gluten-free beer. It is accepted that the samples where the gluten content differs most are the hydrolysed ones because the value obtained strongly depends on the target sequence detected [27]. In a previous study, hordein content in gluten was comparatively assessed using ELISA and MS [28]. This study reveals significant differences between both methods, showing that 10 % of the tested beers give ELISA gluten contents below the limit of quantification, but near-average hordein content by MS. Our assay, using an aptamer that detects hordeins [15], could be an alternative for this kind of samples.

Solid samples provided by laboratory II (Table 3) were extracted alternatively with the conventional 60 % aqueous ethanol extraction method and with cocktail solution to evaluate the influence of reducing and denaturing agents on our method. The results were compared with values obtained with the official method (R5) provided by the company after carrying out the analysis with the Gli 4 competitive method and with an independent analysis performed by a certified Spanish company for gluten analysis (laboratory III). Most of the values obtained with R5 antibody were comparable with those obtained with our method after ethanol extraction except for cappuccino, where a false-positive result is observed. Again, this is probably due to the increased sensitivity of our method. The influence of the cocktail solution on the aptamer-based competitive method was studied. In general, higher results were obtained with the cocktail solution, probably because of a larger yield of the extraction. The exception was the sample containing chocolate, even though PVP and fish gelatin were used to assist the extraction. The discrepancy between the analysis using the same procedure is remarkable, which is an indication of the difficulty of such samples. Additional discrepancies are observed in corn flake samples which would led to labelling as gluten free according to one of the laboratories, but not to the other. Our results with ethanol extraction are in agreement with laboratory II and are closer to laboratory III after cocktail extraction for one of them. Therefore, it can be concluded that the alteration of the protein conformation during the extraction procedure does not significantly affect its recognition by the aptamer (no false negative detected) and the cocktail solution is compatible with our aptamer-based competitive method unlike competitive immunoassays.

Table 3 Samples analysed with the assay using the Gli 4 aptamer after two different extraction protocols and compared with the R5 method carried out by two independent laboratories

Conclusions

The combination of magnetic beads and aptamers as receptors has been proven to be an attractive method for the sensitive quantification of gluten, with a detection limit of 0.5 ppm in the case where the aptamer (Gli 4) with the highest binding affinity to the protein is employed and of 4.9 ppm when using Gli 1, the most abundant aptamer. The assays can quantify gluten in food samples below the legally established limits for the labelling of gluten-free products. The Gli 4-based method is compatible with the cocktail extraction method, allowing the quantification of gluten in heated foods. The assay using the Gli 1 aptamer can quantify gluten in the hydrolysed samples. Both methods are complementary and can be valuable tools in the determination of gluten in foods intended for coeliac patients.