Abstract
We present an evaluation of five diffusion filters for liver vessel enhancement in 3D CTA datasets of the liver. 3D CTA liver images are generally noisy, with limited contrast between vessels and parenchyma, especially for the small vessels. We investigate the performance of five (an)isotropic diffusions filters: Regular Perona-Malik, Coherence-Enhancing Diffusion, Edge-Enhancing Diffusion, Hybrid Diffusion with Continuous Switch and Vessel Enhancing Diffusion on a set of 14 abdominal CTA clinical datasets. The evaluation is based on signal to noise improvement. A parameter optimization is performed on 7 training images, after which the optimal versions of the filters are compared on 7 test images. The results demonstrate that all the diffusion filters improve SNR of the images and Hybrid Diffusion with Continuous Switch and Vessel Enhancing Diffusion gives the largest increase in SNR.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
References
Lesage, D., Angelini, E.D., Bloch, I., Funka-Lea, G.: A Review of 3D Vessel Lumen Segmentation Techniques: Models, Features and Extraction Schemes. Med. Image Anal. 13, 819–845 (2009)
Freiman, M., Joskowicz, L., Sosna, J.: A Variational Method for Vessels Segmentation: Algorithm and Application to Liver Vessels Visualization. In: Proc. of SPIE, vol. 7261, p. 72610H (2009)
Drechsler, K., Laura, C.O.: Comparison of Vesselness Functions for Multiscale Analysis of the Liver Vasculature. In: 10th IEEE International Conference on Information Technology and Applications in Biomedicine, pp. 1–5. IEEE Press, New York (2010)
Erdt, M., Raspe, M., Suehling, M.: Automatic Hepatic Vessel Segmentation Using Graphics Hardware. In: Dohi, T., Sakuma, I., Liao, H. (eds.) MIAR 2008. LNCS, vol. 5128, pp. 403–412. Springer, Heidelberg (2008)
Lehmann, K.S., Ritz, J.P., Valdeig, S., Schenk, A., Holmer, C., Peitgen, H.O., Buhr, H.J., Frericks, B.B.: Portal Vein Segmentation of a 3D-Planning System for Liver Surgery - In Vivo Evaluation in a Porcine Model. Ann. Surg. Oncol. 15, 1899–1907 (2008)
Selle, D., Preim, B., Schenk, A., Peitgen, H.O.: Analysis of Vasculature for Liver Surgical Planning. IEEE Trans. Med. Imaging 21, 1344–1357 (2002)
Alhonnoro, T., Pollari, M., Lilja, M., Flanagan, R., Kainz, B., Muehl, J., Mayrhauser, U., Portugaller, H., Stiegler, P., Tscheliessnigg, K.: Vessel Segmentation for Ablation Treatment Planning and Simulation. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010, Part I. LNCS, vol. 6361, pp. 45–52. Springer, Heidelberg (2010)
Manniesing, R., Viergever, M.A., Niessen, W.J.: Vessel Enhancing Diffusion: A Scale Space Representation of Vessel Structures. Med. Image Anal. 10, 815–825 (2006)
Weickert, J.A.: Coherence-Enhancing Diffusion Filtering. Int. J. Comput. Vis. 31, 111–127 (1999)
Mendrik, A.M., Vonken, E.J., Rutten, A., Viergever, M.A., van Ginneken, B.: Noise Reduction in Computed Tomography Scans Using 3-D Anisotropic Hybrid Diffusion with Continuous Switch. IEEE Trans. Med. Imaging 28, 1585–1594 (2009)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Manh Luu, H., Moelker, A., Klink, C., Mendrik, A., Niessen, W., van Walsum, T. (2012). Evaluation of Diffusion Filters for 3D CTA Liver Vessel Enhancement. In: Yoshida, H., Hawkes, D., Vannier, M.W. (eds) Abdominal Imaging. Computational and Clinical Applications. ABD-MICCAI 2012. Lecture Notes in Computer Science, vol 7601. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-33612-6_18
Download citation
DOI: https://doi.org/10.1007/978-3-642-33612-6_18
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-33611-9
Online ISBN: 978-3-642-33612-6
eBook Packages: Computer ScienceComputer Science (R0)