Abstract
We demonstrate a simple and flexible technique to efficiently activate micro/nano-electromechanical systems (MEMS/NEMS) resonators at their fundamental and higher order vibration modes. The method is based on the utilization of the amplified voltage across an inductor, L, of an LC tank resonant circuit to actuate the MEMS/NEMS resonator. By matching the electrical and mechanical resonances, significant amplitude amplification is reported across the resonators terminals. We show experimentally amplitude amplification up to twelve times, which is demonstrated to efficiently excite several vibration modes of a microplate MEMS resonator and the fundamental mode of a NEMS resonator.
Similar content being viewed by others
Introduction
Electrostatically actuated MEMS/NEMS resonators have demonstrated great potential in wide range of applications, such as sensors1,2,3, communication devices4,5, logic gates6,7,8, and quantum measurements9,10,11,12. This can be attributed to their low power consumption, ease of fabrication, and compatibility with complementary metal-oxide-semiconductor (CMOS) fabrication processes13,14. However, these devices suffer from low signal-to-noise ratio due to the reduced capacitive area for actuation and detection. Also, exploiting higher order vibration modes of MEMS/NEMS resonant structures requires high voltages that cannot be attained using conventional function generators and power supplies. Sensitivity of a resonant sensor can be increased by shrinking their size; preferably to the nanometer range. However, this reduces the capacitive area available for actuation/detection, and dramatically increases the resonator stiffness, hence, the corresponding actuation voltages.
Different dynamical principles have been investigated to enhance the sensitivity of resonator-based sensors, such as bifurcations, jumps, instabilities (for example pull-in)15,16,17,18, higher order modes excitations19,20, and sub-harmonic and super-harmonic resonances21. However, these techniques require high actuation voltages, which often are above the standard range of conventional function generators and on-chip power supplies. Employing active electronics to amplify the signal increases the device footprint, power consumption, and cost. Moreover, amplifiers have limited gain at high frequencies. Parametric excitation has been explored to achieve mechanical amplification22,23. However, it requires special structural designs (to enable modulating the stiffness) and ultra-low damping conditions. Hence, it is of crucial importance to develop flexible, simple, and CMOS compatible techniques to boost the actuation force to excite MEMS/NEMS resonators at their fundamental and higher order modes.
Electrical resonant circuits composed of inductor (L) and capacitor (C) connected in series or parallel have been employed as sensors in wide range of applications including temperature monitoring24, chemical detection25, and pressure sensing26. The concept is based on tracking the shift in the electrical resonant frequency or impendence variation due to the change in a physical stimulus. Matching the electrical resonance frequency of an LC tank circuit, fLC, with the mechanical resonance frequency of a NEMS resonator, fm, has shown to enable the sensitive detection of the motional response of an array of NEMS resonators27, increase the efficiency of microwave detection11,28, and has also been proposed for energy harvesting29,30. The amplified voltage across the capacitor of an LC tank circuit has been exploited to measure the position of the microstructure, and amplify the on-chip available voltage31. It has also been used to stabilize the movable parallel plate beyond the traditional pull-in point32. In addition, in our previous work, we utilized the electrical resonance phenemenon to amplify the response of a single port MEMS structure33.
Electrical resonance occurs when the excitation frequency matches the electrical resonance frequency of the LC tank circuit at which the circuit reactance goes to zero. At this driving frequency, the current flowing in the circuit gets amplified, which leads to an amplified voltage across the individual components (capacitor, inductor) of the LC tank circuit. Thus, the device experiences the voltage amplification due to electrical resonance leading to large vibration amplitude, which is desirable for sensing, actuation, and energy harvesting. Although many studies have explored the LC tank circuits in wide range of applications, there is a lack of thorough understanding of the potential of this technique in activating MEMS and NEMS resonators and their higher order modes. To demonstrate the flexibility and effectiveness of this technique, we investigate its utilization in three different scenarios (case studies). In the first, we match the LC tank resonance frequency, fLC, with the different mechanical resonance frequencies fm of a microplate resonator by tuning an external inductor L. In the second case study, we employ the mixed frequency excitation technique, at which the resonator is excited using a multifrequency signal composed of two AC sources, vAC1 and vAC2 of frequencies f1 and f2, respectively, superimposed to a DC voltage. Due to the quadratic nature of the electrostatic actuation, the frequency spectrum of the resulting signal contains the following six frequency components (f1, f2, 2f1, 2f2, f1 + f2, and f1 − f2). The LC resonance is matched with one of the excitation frequencies f1 = fLC, while the mechanical resonance is excited by the combination resonance (f1 ± f2) = fm 34,35. In the third case study, we use the mixing scheme and demonstrate an efficient actuation of a nanobeam near its fundamental mode.
As shown in Fig. 1, an external tunable inductor, L, and ER switch are connected in series with the MEMS device, to form the electrical resonance circuit. Closing the ER switch will deactivate the electrical resonance. The electrical resonance circuit characteristic equation is given as follow:
where R is the total resistance in the circuit which composed from the internal resistances of the different componenets, Ro, and the inductor internal resistance RL, Q is the electric charge, and C is the overall system capacitance composed of the device capacitance, Co, and the cables parasitic capacitance, Cp. By solving Eq. (1), the steady state voltage across the device, VC, can be obtained using Eq. (2)
When the input frequency, f, matches the electrical resonant frequency,\({f}_{LC}=\frac{1}{2\pi \sqrt{LC}}\), the reactance of the inductor and capacitor cancels each other, hence maximizing the current flowing in the circuit. At resonance, the voltage across the device is increased by a factor of QLC as shown in Eq. (3)
where QLC is the quality factor of the electrical resonance circuit defined as
Materials and Methods
Fabrication
Figure 2(a) shows a schematic of the fabricated clamped-clamped free-free microplate of length (l) 400 µm, width (w) 150 µm, holes diameter (d) 60 µm, and spacing (S) 55 µm. The perforations reduce the time required to fully release the microplate and decrease the influence of squeeze film damping. The microplate is composed of polyimide layer of thickness 4.2 µm coated from top and bottom with Chrome and Gold layers of 50 nm and 200 nm thicknesses, respectively. The lower electrode is divided into six parts; each one can be separately accessed for electrical connection. The proposed design facilitates the excitation of higher order modes by connecting different portions of the lower electrode to excite the desired mode shape19. The upper and lower electrodes are separated by a 3.3 µm air gap. The detail of the fabrication process can be found in36. When the two electrodes are connected to external excitation voltage, the microplate vibrates in the out of plane direction.
Figure 2b shows an SEM image of the nanobeam resonator of length (l) 14.7 µm, width (w) 680 nm, thickness (t) 1.5 µm, and gap (g) 360 nm. The detail of the nanobeam fabrication process can be found in37.
Experimental setup
To demonstrate the flexibility and simplicity of the proposed actuation technique, we utilize different characterization schemes, direct excitation33 and frequency mixing4. In the direct excitation scheme, we utilize a network analyzer (Agilent E5071C) to actuate the resonator with an AC signal, vAC = VAC cos 2πft, connected to an inductor L, which is connected to the drive electrodes. For the microplate, we utilize two electrodes to actuate the resonator and other four electrodes to sense the output motional current as depicted in Fig. 3. This configuration allows the excitation of the first out of plane mode ω11 as well as the higher order mode ω32. Using a low noise amplifier (LNA), we amplify the output signal before connecting it to the input port of the network analyzer for the transmission signal measurement. Also, a laser Doppler vibrometer is used to measure the amplitude of vibration of the microplate due to different level of voltages and input frequencies. Using LabVIEW, the recorded signal is post-processed to generate the frequency response curves. The microplate is biased with a DC voltage VDC connected to the upper electrode and tested at vacuum condition, P = 60 mTorr.
In the mixing technique, in addition to the tools utilized in the direct excitation technique, we utilize a bias tee to connect an additional AC source, vAC2 = VAC2 cos 2πf2t, with the bias DC voltage, which is then connected to the upper electrode. Also, a spectrum analyzer is used to record the generated output signal as shown in Fig. 3. In addition, to characterize the nanobeam, we employ a probe station, ST-500 JANIS, under controlled pressure and temperature conditions.
Results
Case 1
For the initial characterization, we actuate the microplate with a white noise signal while recording the amplitude at different points along the device surface. Figure 4a shows the measured frequency response and the corresponding mode shapes. In this work, we exploit the LC tank concept to actuate the first mode at ω11 = 131.2 kHz and the higher order mode ω32 = 712.6 kHz. Using the direct excitation scheme at VAC = 0 dBm (316 mV), we measure the frequency response of the electrical resonance circuit for different inductance values, as shown in Fig. 4b. The circuit is composed of the external inductor L, the microplate capacitance C0, the parasitic capacitance from the external cables Cp, and the resistance of the circuit R. As shown in Fig. 4b, the electrical resonance values at L1 = 4 mH is fe1 = 138 kHz, and at L2 = 145 µH is fe2 = 723.5 kHz, which are approximately equal to the mechanical resonance near the first mode ω11 and the higher order mode ω32, respectively. Exact matching of the electrical and mechanical resonances is a challenging task and limited by the availability of tunable inductor with fine steps. Using the experimental setup demonstrated in Fig. 3, without the spectrum analyzer and the second AC source, VAC2, we sweep the excitation frequency around the mode of interest while simultaneously recording the response from the laser Doppler Vibrometer and the network analyzer. As shown in Fig. 5a, by connecting L1, the electrical resonance gets activated near the first vibrational mode frequency of the microplate. Thus, the actuation voltage across the MEMS device is amplified, hence, the maximum amplitude of vibration, Wmax, increases by eight times compared to the off-resonance case for the same input voltages. The figure also shows that a slight increase in the input voltage drives the resonator into the nonlinear regime (hardening). Figure 5b shows the network analyzer data, which demonstrate the advantage of the proposed technique in elevating the output current above the noise level and detecting the resonance frequency of the resonator compared with very low signal-to-noise ratio in the case of no electrical resonance (no ER).
Next, L1 is replaced with L2 to allow for simultaneous activation of electrical resonance and the mode ω32. Figure 6a shows the results near the higher order mode at which 12 times amplification factor is reported. Note that in the case of deactivated electrical resonance, the available voltage is not enough to actuate the resonator, and the output motional current is buried in the noise as shown by the blue curve in Fig. 6b. Even increasing the input signal to VAC = 0 dBm (316 mV) did not reveal a clear resonance peak. One can note that the reported vibration amplitudes amplifications obtained by laser measurements in Figs 5(a) and 6(a) are different from those obtained electrically in Figs 5(b) and 6(b). This is due to the imperfect background signal subtraction (the post-processing of transmission signal magnitude) in the electrical measurement results.
Case 2
To demonstrate the flexibility of the proposed technique and to overcome the requirement of matching the electrical and mechanical resonances, we utilize the mixing excitation scheme, Fig. 3. We select inductor L = 220 µH such that the corresponding electrical resonance fe = 632 kHz is far from the mechanical resonance frequencies reported in Fig. 4a. The frequency of the first source vAC1 is tuned at the electrical resonance, f1 = 632 kHz while the frequency of the second source vAC2 is swept such that the combinational frequency of difference type (f2 − f1) is swept around the first mode of vibration ω11 = 131.2 kHz. As shown in Fig. 7a,b, employing the electrical resonance increased the maximum amplitude of vibration by a factor of 6. The spectrum analyzer results, Fig. 7c, demonstrate the significance of the proposed technique in raising the response signal above the noise level compared with noisy response without the electrical resonance.
Case 3
Finally, we demonstrate the potential of the proposed technique to actuate a nanostructure. To this end, we use the LC tank circuit to activate the fundamental mode of a clamped-clamped nanobeam resonator shown in Fig. 2a. As shown in Fig. 8a, we employ the mixing excitation technique to characterize the nanobeam. To form the electrical resonant circuit, we connect a 10 pF external capacitor between the sense and drive electrode and an inductor between the drive electrode and the network analyzer such that the electrical resonance is at fe = 297 kHz. The first source frequency is fixed at the electrical resonance frequency f1 = fe = 297 kHz. The second source frequency, f2, is swept to search for the condition when f1 + f2 = fm = 19.6 MHz. VAC1 is fixed at −5 dBm (177.8 mV) and VAC2 is fixed at 23 dBm (4.466 V). The DC voltage is fixed at 50 V. The spectrum analyzer results, Fig. 8b, show the ability of the technique in revealing the resonance frequency of the nanobeam at 19.6 MHz compared with no response in the case of deactivated electrical resonance. The reported results demonstrate the importance of this technique in revealing the resonance frequency of nanobeam and increasing the quality factor, which enhances the sensitivity of resonator-based sensors.
Conclusions
We show a simple technique based on LC tank resonant circuit to amplify the electrostatic voltage without using active electronics to efficiently actuate MEMS/NEMS resonators. Several case studies have been presented to show the effectiveness, simplicity, and flexibility of this technique to activate higher order modes of a microplate and the fundamental mode of vibration of a nanobeam. By matching the electrical resonance frequency with the microplate higher order mode of vibration, twelve times amplitude amplification is reported using the same input voltages. Employing this technique eliminated the need of bulky active amplifiers that need external power supply to operate them. Also, active amplifiers are limited by their low gain at high frequencies. To demonstrate the flexibility of the method and overcome the requirement of matching the electrical and mechanical resonance frequency, we employed the mixing excitation technique, where theoretically any inductor value can be utilized. However, using small inductor values with a low resistance value results into a higher quality factor and hence higher voltage gain. Also, we demonstrated the effectiveness of this technique in activating nanoresonators and improving the signal to noise ratio. The amplified electrical actuation force facilitates the exploration of nonlinear phenomena, such as parametric resonances, subharmonic and superharmonic resonances, and higher order modes of stiff nanoresonators, which require high actuation voltages that are usually not available or attainable. The proposed technique can be also extended to amplify the forcing of other actuation mechanism, such as piezoelectric and magnetic.
References
Chaste, J. et al. A nanomechanical mass sensor with yoctogram resolution. Nature nanotechnology 7, 301–4 (2012).
Cho, H., Yu, M.-F., Vakakis, A. F., Bergman, L. A. & McFarland, D. M. Tunable, broadband nonlinear nanomechanical resonator. Nano letters 10, 1793–8 (2010).
Olcum, S., Cermak, N., Wasserman, S. C. & Manalis, S. R. High-speed multiple-mode mass-sensing resolves dynamic nanoscale mass distributions. Nature communications 6, 7070 (2015).
Ark-Chew, W. & Nguyen, C. T. C. Micromechanical mixer-filters (“mixlers”). Journal of Microelectromechanical Systems 13, 100–12 (2004).
Bannon, F. D., Clark, J. R. & Nguyen, C. T. C. High-Q HF microelectromechanical filters. IEEE Journal of Solid-State Circuits 35, 512–26 (2000).
Mahboob, I. & Yamaguchi, H. Bit storage and bit flip operations in an electromechanical oscillator. Nature Nanotechnology 3, 275 (2008).
Hafiz, M. A. A., Kosuru, L. & Younis, M. I. Microelectromechanical reprogrammable logic device. Nature communications 7, 11137 (2016).
Guerra, D. N. et al. A Noise-Assisted Reprogrammable Nanomechanical Logic Gate. Nano Letters 10, 1168–71 (2010).
Sillanpää, M. A., Sarkar, J., Sulkko, J., Muhonen, J. & Hakonen, P. J. Accessing nanomechanical resonators via a fast microwave circuit. Applied Physics Letters 95, 011909 (2009).
Irish, E. K. & Schwab, K. Quantum measurement of a coupled nanomechanical resonator–Cooper-pair box system. Physical Review B 68, 155311 (2003).
Bagci, T. et al. Optical detection of radio waves through a nanomechanical transducer. Nature 507, 81 (2014).
Sillanpää, M. A., Roschier, L. & Hakonen, P. J. Inductive Single-Electron Transistor. Physical Review Letters 93, 066805 (2004).
Sam, J., Kumar, J., Tetteh, E. A. & Braineard, E. P. A study of why electrostatic actuation is preferred and a simulation of an electrostatically actuated cantilever beam for mems applications. International Journal of Engineering Sciences & Emerging Technologies 6(5), 441–446 (2014).
Younis, M. I. MEMS Linear and Nonlinear Statics and Dynamics, (Springer, 2011).
Kumar, V. et al. Bifurcation-based mass sensing using piezoelectrically-actuated microcantilevers. Applied Physics Letters 98, 153510 (2011).
Nguyen, V.-N., Baguet, S., Lamarque, C.-H. & Dufour, R. Bifurcation-based micro-/nanoelectromechanical mass detection. Nonlinear Dynamics 79, 647–62 (2015).
Bouchaala, A. et al. A smart microelectromechanical sensor and switch triggered by gas. Applied Physics Letters 109, 013502 (2016).
Jaber, N., Ilyas, S., Shekhah, O., Eddaoudi, M. & Younis, M. I. Resonant Gas Sensor and Switch Operating in Air With Metal-Organic Frameworks Coating. Journal of Microelectromechanical Systems 27, 156–163 (2018).
Jaber, N., Ramini, A., Carreno, A. A. & Younis, M. I. Higher order modes excitation of electrostatically actuated clamped–clamped microbeams: experimental and analytical investigation. Journal of Micromechanics and Microengineering 26, 025008 (2016).
Dohn, S., Sandberg, R., Svendsen, W. & Boisen, A. Enhanced functionality of cantilever based mass sensors using higher modes. Applied Physics Letters 86, 233501 (2005).
Ali, H. N. & Mohammad, I. Y. Dynamics of MEMS resonators under superharmonic and subharmonic excitations. Journal of Micromechanics and Microengineering 15, 1840 (2005).
Karabalin, R. B., Feng, X. L. & Roukes, M. L. Parametric Nanomechanical Amplification at Very High Frequency. Nano Letters 9, 3116–23 (2009).
Mahboob, I. & Yamaguchi, H. Piezoelectrically pumped parametric amplification and Q enhancement in an electromechanical oscillator. Applied Physics Letters 92, 173109 (2008).
Ong, K. G., Grimes, C. A., Robbins, C. L. & Singh, R. S. Design and application of a wireless, passive, resonant-circuit environmental monitoring sensor. Sensors and Actuators A: Physical 93, 33–43 (2001).
García-Cantón, J., Merlos, A. & Baldi, A. A wireless LC chemical sensor based on a high quality factor EIS capacitor. Sensors and Actuators B: Chemical 126, 648–54 (2007).
Chen, P. J., Saati, S., Varma, R., Humayun, M. S. & Tai, Y. C. Wireless Intraocular Pressure Sensing Using Microfabricated Minimally Invasive Flexible-Coiled LC Sensor Implant. Journal of Microelectromechanical Systems 19, 721–34 (2010).
Truitt, P. A., Hertzberg, J. B., Huang, C. C., Ekinci, K. L. & Schwab, K. C. Efficient and Sensitive Capacitive Readout of Nanomechanical Resonator Arrays. Nano Letters 7, 120–6 (2007).
Massel, F. et al. Microwave amplification with nanomechanical resonators. Nature 480, 351 (2011).
Abdelmoula, H. & Abdelkefi, A. The potential of electrical impedance on the performance of galloping systems for energy harvesting and control applications. Journal of Sound and Vibration 370, 191–208 (2016).
Abdelmoula, H. & Abdelkefi, A. Investigations on the presence of electrical frequency on the characteristics of energy harvesters under base and galloping excitations. Nonlinear Dynamics 89, 2461–79 (2017).
Cagdaser, B. & Boser, B. E. Low-Voltage Electrostatic Actuation With Inherent Position Feedback. Journal of Microelectromechanical Systems 21, 1187–96 (2012).
Cagdaser, B. & Boser, B. E. Resonant drive for stabilizing parallel-plate actuators beyond the pull-in point. In: The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS ‘05., pp 688–92 Vol. 1 (2005).
Hasan, M. H., Alsaleem, F. M., Jaber, N., Hafiz, M. A. A. & Younis, M. I. Simultaneous electrical and mechanical resonance drive for large signal amplification of micro resonators. AIP Advances 8, 015312 (2018).
Jaber, N., Ramini, A. & Younis, M. I. Multifrequency excitation of a clamped–clamped microbeam: Analytical and experimental investigation. Microsystems &Amp; Nanoengineering 2, 16002 (2016).
Jaber, N., Ramini, A., Hennawi, Q. & Younis, M. I. Wideband MEMS resonator using multifrequency excitation. Sensors and Actuators A: Physical 242, 140–5 (2016).
Arevalo, A. et al. A versatile multi-user polyimide surface micromachinning process for MEMS applications. In: 10th IEEE International Conference on Nano/Micro Engineered and Molecular Systems, pp 561–5 (2015).
Kazmi, S. N. R. et al. Tunable nanoelectromechanical resonator for logic computations. Nanoscale 9, 3449–57 (2017).
Acknowledgements
We acknowledge financial support from King Abdullah University of Science and Technology.
Author information
Authors and Affiliations
Contributions
M.A.H. and N.J. conceived the idea and designed the experiments. S.N.R.K. fabricated the Nano devices. N.J. and S.I. fabricated the microplate. N.J., M.A.H. and S.N.R.K. performed the experiments. N.J. M.A.H. and M.I.Y. prepared the manuscript. M.H.H. and F.A. contributed in developing concept and provided input to the manuscript, and M.I.Y. supervised the project.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Jaber, N., Hafiz, M.A.A., Kazmi, S.N.R. et al. Efficient Excitation of Micro/Nano Resonators and Their Higher Order Modes. Sci Rep 9, 319 (2019). https://doi.org/10.1038/s41598-018-36482-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-36482-1
- Springer Nature Limited
This article is cited by
-
An asymmetric mode-localized mass sensor based on the electrostatic coupling of different structural modes with distributed electrodes
Nonlinear Dynamics (2022)
-
Analytical modeling of mechanical behavior for MEMS/NEMS-based single-clamped multilayer resonators with symmetrical complex shapes
Microsystem Technologies (2021)
-
Investigation of on-chip integrated inductors fabricated in SOI-MUMPs for RF MEMS ICs
Analog Integrated Circuits and Signal Processing (2020)