Abstract
The accuracy of the fibrotic plaque segmentation is vital in identifying the coronary artery stenosis. In this paper, we address an automated approach (APDE-GMM) for separating the fibrotic plaque area of intravascular optical coherence tomography (IV-OCT) images. Under this approach, an objective function consisting of a new energy functional with Rayleigh distribution and the negative log-likelihood function of Gaussian mixture model (GMM) is developed. Also, the study presents an adaptive diffusivity function where the gradient threshold can be associated to suppress the effect of speckle noise. The parameter estimation is carried out by the expectation–maximization technology. In addition, this paper derives a fourth-order partial differential equation (PDE) via Euler–Lagrange equation to obtain the optimal solutions. It has been compared to other segmentation approaches on synthetic and clinical IV-OCT images. The results demonstrate that APDE-GMM segmentates more accurately.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
Intravascular optical coherence tomography (IV-OCT) image is an intracoronary detecting technique which has high resolution and low radiation. Perfect segmentation of the fibrotic plaque area in IV-OCT images can provide useful information of coronary artery stenosis. As a result, doctors could get a more reliable diagnostic of coronary atherosclerotic heart disease (CAD).
Relevant IV-OCT image segmentation methods have been widely reported in recent years. Zahnd et al. [1] segmented the fibrotic plaque via a front propagation scheme which runs in a 4D multi-parametric space to identify the healthy status. Segmentation IV-OCT using support vector machine (SVM) was found in the literature [2]. The theory of anisotropic diffusion was also investigated in IV-OCT image segmentation [3]. Celi et al. modeled fibrotic plaque using Ostu’s method and mathematical morphology [4]. Recently, convolutional neural networks (CNN), such as ResNet50-V2, have been applied successfully to IV-OCT images with plaque [5]. These methods require a large number of images for training. In addition, finite mixture model (FMM) technique, for instance, Gaussian mixture model (GMM), Student’s-t mixture model (SMM) have been addressed [6,7,8,9]. Some researches [6, 10] incorporated pixel position information into GMM through Markov random field (MRF), so that their methods are highly resistant to noise. Cheriyan et al. [7] combined the independent component analysis (ICA) with GMM for unsupervised medical image segmentation. Due to the incorporation of ICA, the computation of their method was expensive. Although statistical methods have been widely applied to various image segmentation, no report has been found on detecting the fibrotic plaque from IV-OCT using FMM so far.
Due to the clinical IV-OCT images suffering from the heavy speckle noise, some researches apply partial differential equation (PDE) on IV-OCT images for denoising [11,12,13,14,15,16]. In [11], the fourth-order PDE with a nonlinear hyperbolic diffusion was used for eliminating the impact of noise. However, this approach converges slowly. Another PDE with two-dimension Gaussian filter was introduced in [12]. The work of [13] introduced an algorithm where a nonlinear hyperbolic diffusion-combined Gaussian kernel was utilized for image denoising, but it results in higher calculation cost. These researches show that the PDE-based denoising method can effectively remove noise while preserving image edge [14]. Reference [15] reported an improved algorithm using fourth-order PDE with edge noise interior (ENI). This method exhibits good robustness to different levels of speckle noise. But it needs to count the number of homogeneous pixels in the neighborhood, which is a hard work. Recently, Kumar et al. [16] proposed a PDE-based fuzzy c-mean (FCM) algorithm in order to assist in eliminating the effect of Poisson noise. Their method helps to get rid of the block artifact in the process of cell segmentation.
In this paper, we propose a hybrid framework for IV-OCT image segmentation. Comparing with other existing algorithms, this framework has the following properties: (1) this study develops a unsupervised image segmentation approach where the negative log-likelihood function of GMM is designed within the framework of a new energy functional with Rayleigh distribution; (2) the integrand of the proposed energy functional is divided into two parts: the likelihood function of Rayleigh distribution and the adaptive diffusivity function with respect to gradient; (3) it recommends applying adaptive diffusivity function with the gradient threshold to withstand the effect of speckle noise; (4) from the computational perspective, we derive a fourth-order PDE for iteratively finding the optimal solutions through Euler–Lagrange equation; (5) The M-step of EM algorithm is applied to optimize model parameters of GMM.
The rest of the article is organized as follows. A review of the GMM is introduced in Sect. 2. Section 3 describes the main concepts of our approach. Section 4 provides more details about its implementation. The experimental results could be found in Sect. 5, and conclusions are summarized in Sect. 6.
2 A review of GMM
In order to label the L pixels of an image into K parts, the GMM assumes that each observation \({x_i}\) is independent of the label \({{\Omega } _j}\). In this case, the density function of each \({x_i}\) can be described by
where \({\Pi } =\{{{\pi }_{ij}}\}\), \(i=(1,2,\dots ,L)\), \(j=(1,2,\dots ,K)\) is the set of prior probability, which satisfies the constraints
and \({{\pi }_{ij}}\) indicates the possibility of the pixel \({{x}_{i}}\) belongs to the jth label. In (1), \(g({{x}_{i}}|{{{\theta } }_{j}})\) denotes the multivariate Gaussian probability density function (PDF) with mean \(\mu _{j}\) and covariance \(\varSigma _{j}\)
where \({{\theta }_{j}}\) represents the parameter set \(\{\mu _{j},\varSigma _{j}\}\), and \(|\varSigma _{j}|\) is the determinant of \(\varSigma _{j}\). Thus, the joint conditional PDF of observation data \(X=({{x}_{1}},{{x}_{2}},\dots ,{{x}_{L}})\) can be modeled using
The parameters associated with the GMM are usually estimated using EM scheme. Therefore, one needs to maximize the following log-likelihood function of the GMM.
3 Proposed method
In this section, a hybrid framework is proposed for IV-OCT image segmentation, which blends the fourth-order nonlinear PDE and GMM. We start by developing an adaptive speckle noise filter based on fourth-order PDE.
The speckle noise of IV-OCT images follows the Rayleigh distribution [17]. This problem is described as
where u and \(\bar{u}\) are the restored and observed initial images with size of \(m\times n\), respectively. In this case, the maximum likelihood estimate of u can be obtained by minimizing \(p(u|\bar{u})\).
Based on this, the energy functional is defined as follows
where \(\lambda \) is a regularization parameter, and \({{\nabla }^{2}}\) stands for Laplacian operator. In Cartesian coordinates
This paper would establish a function with respect to the smoothness of the image as implemented by \(|{{\nabla }^{2}}u|\). According to the physical theory of diffusion, the second term of the right-hand side of (8) is defined by
where \(s=|{{\nabla }^{2}}u|\). This study defines an adaptive nonlinear diffusivity function, given by
Generally, the diffusivity function \(\phi (s)\) is a monotonically decreasing function, since the idea is to reduce smoothing at edge where \(|{{\nabla }^{2}}u|\) is large. Following this, the gradient threshold \(\eta (u)\) is defined as
where \(||\cdot ||\) represents Euclidean distance, mean \(||\nabla u||\) denotes the mean value of \(||\nabla u||\), and med \(||\nabla u||\) stands for the median value of \(||\nabla u||\), \(\beta \) is a regularized parameter, and N is the number of iterations. In Fig. 1, we exhibit an experiment to compare the smoothing properties of classical Y–K diffusivity function [18] to ours. The diffusivity function of Y–K model is independent to iterations (see Fig. 1a). Figure 1b depicts the plots of our adaptive diffusivity function with parameters \(\alpha =0.5\), \(\beta =0.05\). These diffusivity functions are applied to noisy image that exists because of the speckle noise (intensity \(5\%\)). For fair comparison of the performance, the iteration number of two models is set equal. As shown in Fig. 1f, the proposed diffusion function achieves a better result with more noise removal, with our adaptive diffusivity function, each region could be smoothed well.
When constructing this adaptive diffusivity function, all the following items should be considered. (i) The diffusivity function \(\phi (s)\) follows a downward trend with increasing of smoothing term \(|{{\nabla }^{2}}u|\) (Laplacian of u); (ii) as iteration increases, the plot of diffusivity function \(\phi (s)\) moves down; (iii) at the beginning of iteration, image contained excessive noise, the higher diffusivity ought to be chosen in this case; (iv) as \(|{{\nabla }^{2}}u|\) increases, the impact of parameters N, \(\alpha \) and \(\beta \) on diffusivity function \(\phi (s)\) will be weakened, and \(\phi (s)\) converges to zero. Again, we observe from Fig. 1 that our adaptive diffusivity function meets all these properties.
Since logarithm is a monotonically increasing function, we take the negative logarithm of the likelihood function as an energy function. By introducing the posterior probability \(z_{ij}\), minimizing the negative log-likelihood function in (5) leads to minimizing the following expression
where the posterior probability \(z_{ij}\) at the current iteration is
Generally, classical GMM cannot deal with noise properly. It is because GMM does not consider the spatial correlation of pixels. Speckle noise exists elsewhere in real IV-OCT images, so the fourth-order PDE based on Rayleigh distribution is introduced here. Finally, the APDE-GMM is implemented by minimizing the following objective function:
where \(\lambda \) is a regularized parameter. As shown in Fig. 2, the fusion model illustrated here is an iterative strategy. It incorporates denoising and segmentation in a single produce.
4 Implementation issues
In the following, we discuss the numerical approximation of the proposed method. The proposed objective function J is the linear sum of the energy functional \(J_1\) and the negative log-likelihood function \(J_2\). Then, minimizing the objective function J in (15) is equivalent to minimizing \(J_1\) and \(J_2\), respectively. In this study, Euler–Lagrange equation and EM algorithm are, respectively, applied to minimize energy functional \(J_1\) and the negative log-likelihood function \(J_2\). Thus,
The efficient implementation of the APDE-GMM depends on the correct estimation of the parameter \(u_{mn}\). According to variational method, if an optimal estimation of \(u_{mn}\) exists, it satisfies the Euler–Lagrange equation. Based on this, from the objective function (16), we have
This PDE may be solved numerically using a finite difference scheme. Letting \({{\gamma }_{mn}}=\phi (|{{\nabla }^{2}}u_{mn}|){{\nabla }^{2}}u_{mn}\), the second term of left-hand side of (17) becomes
with
where h is step length. Considering that the problem of \(||\cdot ||\) is Euclidean distance, the function \(\eta (u)\) of (12) becomes
Taking h = 1, we have the numerical approximation about (17) in the following form
where
Next, we are going to discuss the optimization of parameters \(\mu _{j}\), \(\varSigma _{j}\) and \(\pi _{ij}\). The EM technique is utilized to find the optimal parameters. To satisfy GMM, the observed data x is L-length 1D \(u_{mn}\), here, \(L=NM\). For mean \(\mu _{j}\), the optimal value of it occurs when the partial derivative of objective function J with respect to \(\mu _{j}\) is zero
Eventually, we get the mean \(\mu _{j}\) at the (\(t+1\)) iteration step.
Similarly, the estimation of covariance is worked out via \(\varSigma _{j}\) which satisfies
Then, letting \(\partial J\text {/}\partial \varSigma _{j}=\text {0}\), the update of covariance \(\varSigma _{j}\) at the (\(t+1\)) iteration is as follows
As for priori probability \({{\pi }_{ij}}\), we use the Lagrange multiplier v for each pixel. Calculate the derivative of objective function J with \({{\pi }_{ij}}\) and set the result to zero.
From the above, the estimation of prior \({{\pi }_{ij}}\) is given by
The computation process of APDE-GMM is summarized as:
- 1.
Initialize: label K, step \(\varDelta t\), mean \(\mu _{j}\), covariance \(\varSigma _{j}\), and prior \(\pi _{ij}\).
- 2.
Compute the estimated image \(u_{mn}\) using (21)
- 3.
E-step: Calculate the posterior probability \(z_{ij}\) by (14)
- 4.
M-step: Update parameters \(\mu _{j}\), \(\varSigma _{j}\), and \(\pi _{ij}\) using (24), (26), and (28), respectively.
- 5.
Check the convergence of the objective function J in terms of (16). If the converging condition is not satisfied, we need to go back to step 2 and recalculate the value of objective function J until it converges.
When the objective function J converges, the label \({{\Omega }_{j}}\) of each pixel \({{x}_{i}}\) can be obtained by calculating the posterior probability \(z_{ij}\), and then the image segmentation can be completed. Each pixel \({{x}_{i}}\) satisfies the following conditions:
5 Experiments
In this section, the evaluation of APDE-GMM is conducted using three synthetic images (\(256\times 256\) pixels) and twenty IV-OCT images from nine CAD patients (eight males and one female). These IV-OCT images (\(300\times 300\) pixels) were collected by a C7 model OCT scanner (St. Jude Medical, USA), which was provided by the Department of Cardiology at Peking Union Medical College Hospital, China. The plaque areas of some typical lesion images are manually labeled by cardiologists in this hospital as the ground truth. With regard to the experimental environment, the hardware environment is 2.30 GHz Intel Core i5-6300HQ CPU, NVIDIA GeForce GTX 960M GPU, and 8.00 GB DDR4 memory, and the software environment is Windows 10 operating system and MATLAB 2016a software. For comparison, the following several metrics are involved: (a) Misclassification Ratio (MCR), Jaccard Similarity (JS), Dice Similarity Coefficient (DISC) and Probabilistic Rand Index (PRI).
MCR calculates the proportion of misclassified pixels in total pixels, which is defined below:
MCR takes its value between 0 and 100, while the closer the MCR value is to zero, the more the segmentation result approaches to the ground truth.
DISC provides another similarity measurement of two sample sets.
where TP is the number of true positives, FN is the number of false negatives and FP is the number of false positives. DISC ranges from 0 to 100, while a higher value indicates better performance.
JS is a statistic used for testing the similarity. It applies the overlap degree between the segmentation result and the actual to evaluate the algorithm performance.
where \({{S}_\mathrm{seg}}\) and \({{S}_\mathrm{gt}}\) stand for segmentation result and ground truth, respectively. JS takes value between 0 and 1, the closer JS is to 0, the poorer the segmentation result is.
Next, we adopt PRI to compare the similarity of two different ways.
where L is the number of observations. If pixel i and j belong to the same class in evaluated image, the value of \({c}_{ij}\) is one. Otherwise, its value is zero. \({p}_{ij}\) is the ground truth probability that pixel i and j belong to the same class. PRI value ranges from 0 to 1, while a smaller value represents a more accurate segmentation result.
5.1 Effect of parameters \(\alpha \) and \(\beta \) in diffusivity function
According to (11) and (12), the gradient threshold \(\eta (u)\) is proportional to diffusivity function \(\phi (s)\). Therefore, in order to satisfy the requirement of \(\phi (s)\), we need to choose the appropriate parameters \(\alpha \) and \(\beta \) for \(\eta (u)\). We first discuss the influence of two parameters \(\alpha \) and \(\beta \) on the \(\eta (u)\). Figure 3 displays the plots of diffusivity function \(\phi (s)\) with different values of \(\alpha \) and \(\beta \). When both \(\alpha \) and \(\beta \) are smaller, \(\eta (u)\) will be smaller in the whole iteration. On the contrary, \(\eta (u)\) will remain larger throughout the iteration. Therefore, from Fig. 3, it can be seen that the first choice (\(\alpha =0.2\), \(\beta =0.02\)) led to weak smoothing effect on its early iterations among all the test cases. For the results obtained with the sixth set (\(\alpha =1\), \(\beta =0.1\)), we found the heavy denoising performance may be carried out throughout the iteration process. It is because, in this case, a larger value is assigned to diffusivity function \(\phi (s)\). Based on the above results, we noted that the diffusivity function \(\phi (s)\) might provide a relatively better denoising properties while we take \(\alpha \) from 0.4 to 0.6, and \(\beta \) set its value in [0.04, 0.06]. This is the reason why we set parameters \(\alpha =0.5\) and \(\beta =0.05\) in the following experiments.
5.2 Experiments with synthetic images
To test the behavior of APDE-GMM, the experiment is first conducted on three synthetic images with different levels of complexity, which is illustrated in Fig. 4. We would like to compare the performance with several existing algorithms based on the model of clustering or FMM. In this regard, this paper considers the standard GMM [19], FCM [20], SMM [21], fast and robust spatially constrained Gaussian mixture model (FRSCGMM) [22] and fourth-order PDE-based fuzzy c-means (AFPDEFCM) [16]. For all of these approaches, the same iterations are used. The first row demonstrates original images corrupted by speckle noise (intensity 5\(\%\)). The proposed APDE-GMM results are compared with those produced by the above-mentioned algorithms shown in Fig. 4. All approaches can successfully label these images. However, we also observe that noise is still in the results obtained using GMM, SMM and FCM. They might not consider the spatial relationship between neighboring pixels. FRSCGMM removes noise effectively, but the visual effect of the edge seems too smooth. Besides, the segmentation result also indicates that AFPDEFCM is efficient in dealing with noise. This could be because of the use of Y–K diffusivity function. From Fig. 4, we can conclude that the APDE-GMM outperforms the other comparison approaches in the quality of image. It reduces the effect of noise significantly. This may be due to the application of adaptive diffusion function.
To test the performance of a model, only visual comparison is not enough and the segmentation results need to be evaluated through quantitative metrics. Here, two quality assessment metrics PRI and MCR are implemented to evaluate the difference between the ground truth and the segmented results. The results are listed in Tables 1 and 2. One can discover that PRI stays above 0.9847 to all test images, which confirm the efficiency of the APDE-GMM. In addition, FCM, GMM and SMM get the poor results in terms of PRI and MCR. MCR values of our method can remain more stable and lower than the other methods.
To compare APDE-GMM with the above methods, the influence of different noise levels on them is discussed. Figure 5 displays the average MCR and PRI of three images for all approaches. The intensity of speckle noise ranges from 1 to 9%. It can be found that the AFPDEFCM with Y–K diffusivity function performs better than those of FRSCGMM. However, the latter is more robust to speckle noise than FCM, GMM, and SMM. In addition, as evident from Fig. 5, the APDE-GMM outperforms other methods with the lowest MCR. It is due to the fact that this method applies an adaptive diffusivity function as well as statistics-based GMM, which is able to model the intensity distribution of an image more accurately. Hence, based on all results reported by this experiment, we can preliminarily summarize that the APDE-GMM achieves better segmentation results.
5.3 Experiments with IV-OCT images
In this subsection, we first conduct the application of the APDE-GMM on clinical IV-OCT images, and some of corresponding results are given in Fig. 6. The images in the first and second rows are original images, and ground truth, respectively. It can be observed that our approach detects accurately the fibrotic plaque from vessel lumen of coronary artery. This is due partly to the fact that adaptive diffusivity function provides better noise removal and edge preservation, so that our method can overcome the effect of heavy speckle noise on the results. Besides, to quantitatively assess the performance of APDE-GMM, this experiment also investigates the performance of GMM with spatial information extracted from saliency map (GMM-SMSI) [23], which considers the spatial relationship between pixels. All these methods are evaluated on twenty IV-OCT images. The results are depicted in Fig. 7. We have found that APDE-GMM performs very well for the fibrotic plaque segmentation. Also, the performance of both GMM-SMSI and FRSCGMM is better, but not significant, compared to the SMM and GMM. With respect to MCR and PRI values, it should be remarked that FCM provides poor performance.
The last experiment provided here is to demonstrate the accuracy of the APDE-GMM for various lesion IV-OCT images, and experiments are carried out on twenty IV-OCT images using our model compared with other methods. Figure 8 exhibits a visual comparison of partial segmentation results. We can observe that our method gives competitive results for these test images. The results indicate that the APDE-GMM can maintain a good balance between edge preservation and image denoising. To further investigate the advantages of APDE-GMM in detecting fibrotic plaque, this paper gives quantitative analysis in terms of JS and DISC, and results are illustrated in Fig. 9. By comparing, the performance of our model is still better than other six approaches.
6 Conclusions
This paper presented an unsupervised IV-OCT image segmentation approach based on GMM and the fourth-order PDE. In this scheme, an adaptive diffusivity function was incorporated into PDE, so that our method can effectively remove high-level speckle noise. The proposed APDE-GMM achieved accurate IV-OCT image segmentation compared with well-known algorithms, and results proved that APDE-GMM may assist doctor in diagnosis of CAD. Future work will improve the proposed model in order to separate various types of plaque better, such as calcified plaque.
References
Zahnd, G., Hoogendoorn, A., Combaret, N., et al.: Contour segmentation of the intima, media, and adventitia layers in intracoronary OCT images: application to fully automatic detection of healthy wall regions. Int. J. Comput. Assist. Radiol. Surg. 12, 1923–1936 (2017)
Guo, X., Tang, D., David, M., et al.: A machine learning-based method for intracoronary OCT segmentation and vulnerable coronary plaque cap thickness quantification. Int. J. Comput. Methods 15(1), 1–12 (2018)
Xu, M., Cheng, J., Wong, D.W.K.: Automatic image classification in intravascular optical coherence tomography images. In: Proceedings of IEEE Region 10 Conference (TENCON), pp. 1544–1547 (2016)
Celi, S., Berti, S.: In-vivo segmentation and quantification of coronary lesions by optical coherence tomography images for a lesion type definition and stenosis grading. Med. Image Anal. 18(7), 1157–1168 (2014)
Xu, M., Cheng, J., Li, A., et al: Fibroatheroma identification in intravascular optical coherence tomography images using deep features. In: Proceedings of Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 1501–1504 (2017)
Ji, Z., Huang, Y., Xia, Y., et al.: A robust modified Gaussian mixture model with rough set for image segmentation. Neurocomputing 266, 550–565 (2017)
Cheriyan, M.M., Prawin, A.M., Kumar, A.: Blind source separation with mixture models—a hybrid approach to MR brain classification. Magn. Reson. Imaging 54, 137–147 (2018)
Banerjeel, A., Maji, P.: Constrained Students’ \(t\)-distribution based mixture model for robust image segmentation. J. Math. Imaging Vis. 60(3), 355–381 (2018)
Liu, Z., Song, Y., Xie, C., et al.: A new clustering method of gene expression data based on multivariate Gaussian mixture models. Signal Image Video Process. 10(2), 359–368 (2016)
Ahmadvand, A., Kabiri, P.: Multispectral MRI image segmentation using Markov random field model. Signal Image Video Process. 10(2), 251–258 (2016)
Barbu, T.: Nonlinear fourth-order hyperbolic PDE-based image restoration scheme. In: Proceedings of IEEE International Conference on e-Health and Bioengineering, pp. 19–21 (2015)
Barbu, T.: A hybrid nonlinear fourth-order PDE-based image restoration approach. In: Proceedings of International Conference on System Theory, Control and Computing, pp. 754–756 (2016)
Barbu, T.: Additive noise removal using a nonlinear hyperbolic PDE-based model. In: Proceedings of International Conference on Development and Application Systems, pp. 1–5 (2018)
Heydari, M., Karami, M.R., Babakhani, A.: A new adaptive coupled diffusion PDE for MRI Rician noise. Signal Image Video Process. 10(7), 1212–1218 (2016)
Soorajkumar, R., Kumar, P.K., Girish, D.R., et al: Fourth order PDE based Ultrasound despeckling using ENI classification. In: Procedings of International Conference on Signal Processing and Communication, pp. 1–5 (2016)
Kumar, R., Srivastava, S., Srivastava, R.: A fourth order PDE based fuzzy c-means approach for segmentation of microscopic biopsy images in presence of poisson noise for cancer detection. Comput. Methods Programs Biomed. 146, 59–68 (2017)
Schmitt, J.M.: Optical coherence tomography (OCT): a review. IEEE J. Sel. Top. Quantum Electron. 5(4), 1205–1215 (1999)
You, Y.L., Kaveh, M.: Fourth-order partial differential equations for noise removal. IEEE Trans. Image Process. 9(10), 1723–1730 (2000)
Titterington, D.M., Smith, A.F.M., Makov, U.E.: Statistical Analysis of Finite Mixture Distributions. Wiley, Hoboken (1985)
Trivedi, M.M., Bezdek, J.C.: Low-level segmentation of aerial images with fuzzy clustering. IEEE Trans. Syst. Man Cybern. 16(4), 589–598 (1986)
Sfikas, G., Nikou, C., Galatsanos, N.: Robust image segmentation with mixtures of Student’s-\(t\) distributions. In: Proceedings of IEEE International Conference on Image Processing, pp. 273–276 (2007)
Nguyen, T.M., Wu, Q.M.J.: Fast and robust spatially constrained Gaussian mixture model for image segmentation. IEEE Trans. Circuits Syst. Video Technol. 23(4), 621–635 (2013)
Bi, H., Tang, H., Yang, G., et al.: Accurate image segmentation using Gaussian mixture model with saliency map. Pattern Anal. Appl. 21(3), 869–878 (2018)
Acknowledgements
The authors would like to thank the anonymous reviewers and the associate editor for their insightful comments that significantly improved the quality of this paper. This work was supported by the National Nature Science Foundation of China under Grant 61872143.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Wang, P., Zhu, H. & Ling, X. Intravascular optical coherence tomography image segmentation based on Gaussian mixture model and adaptive fourth-order PDE. SIViP 14, 29–37 (2020). https://doi.org/10.1007/s11760-019-01520-6
Received:
Revised:
Accepted:
Published:
Issue Date: