Introduction

Chromium, due to its wide usage in various industries such as electroplating, tanning, textile, and leather, is released into the environment in the form of treated industrial wastewater (Patterson and Passino 1987; Owlad et al. 2009). In the natural environment, chromium occurs in two oxidation states; Hexavalent chromium or Cr(VI) in the oxoanion form and Trivalent Chromium or Cr(III). Cr(VI) is highly mobile and toxic species when compared to Cr(III) which has low solubility and mobility (Koujalagi et al. 2013). Chromium is associated with various chronic and acute health effects in the human population including lung cancer, dermatitis, skin irritation and epigastric pain (NIEHS 2011; Sharma et al. 2012). As a consequence, the maximum permissible limit in drinking water is 0.01 mg/L for Cr(VI) and 0.10 mg/L for total Chromium (USEPA 2011), and in wastewater, its limit is 0.05 mg/L (USEPA 2013). Thus, Cr(VI) removal from drinking water is essential and carried out by various techniques namely, coagulation and sedimentation, electrocoagulation (Golder et al. 2007), precipitation (Guo et al. 2006), crystallization, Membrane filtration, Reverse osmosis (Hafez and El-Mariharawy 2004; Perez-González et al. 2012; Fu and Wang 2011), ion exchange (Galan et al. 2005), adsorption (Jabeen et al. 2011), bioremediation (Xie et al. 2013), phytoremediation (Narayani and Vidya 2012; Miao and Yan 2013) etc. However, these methods are limited by costly technology, high operational and maintenance cost, skilled labour requirement: particularly in membrane filtration, and sludge disposal (Sharma et al. 2009; Hu et al. 2011). Of these methods, adsorption is the most appropriate, effective and versatile method for chromium removal.

Diverse form of organic, inorganic and natural bio-based materials were used for the removal of chromium, either as Cr(VI) and or Cr(III) by adsorption process such as, various biowaste (Parlayici and Pehlivan 2015; Kwak et al. 2015), chitosan fibres (Li et al. 2015), graphene (Jabeen et al. 2011), resin (Fu et al. 2013), Fly ash (Vaid et al. 2013), clay (Yadav et al. 2016; Fu et al. 2015) etc. Cellulose is a recalcitrant sustainable natural polymer, which has potential use as bio-adsorbent for various environment pollutants (Singha and Guleria 2014). However, cellulose has poor adsorption for Cr(VI) as such. Though, the modification of polymer surface with various functional moieties, like magnetic polyaniline nanocomposite cellulose (Qiu et al. 2015), Amidoximated Cellulose (Saliba et al. 2000), cellulose functionalized with quaternary ammonium moieties (Gurgel et al. 2009), cellulose anion exchanger with tertiary amine (Anirudhan et al. 2009), styrene grafted cellulose microsphere (Zhang et al. 2012), Oxidised polyaniline cellulose fibre composite (Liu et al. 2013) etc. have been used for Cr(VI) adsorption. These derivatives show ion exchange or electrostatic interaction based adsorption for Cr(VI) oxoanion. However, these functional materials have the disadvantage of being costly, non-biodegradable and may release toxic secondary metabolites during the life cycle of the material.

Nanoscale zerovalent iron (nZVI) has a high surface area which leads to high reactivity andmakes it an ideal sorbent for contaminant treatment (Crane and Scott 2012; Mukherjee et al. 2015; Stefaniuk et al. 2016). However, usage of nZVI in remediation is limited by either of the two phenomenon namely, agglomeration due to magnetic property of iron and surface passivation (Ponder et al. 2000). Surface passivation leads to the formation of iron oxide layer upon exposure to oxygen in the air, leading to loss of activity of the sorbent. Thus, various stabilizers and immobilizers have been studied for the stability of zerovalent iron nanoparticles (Trujillo-Reyes et al. 2014; Yadav et al. 2016). Polysaccharide-based stabilizers like starch (Alidokht et al. 2011), Chitosan (Horzum et al. 2013), Calcium alginates (Bezbaruah et al. 2009) and CMC (Singh et al. 2011) have been used in stabilizing and immobilizing iron nanoparticles. Most of these stabilizers are either water soluble or have enhanced microbial degradation susceptible to release and destabilize the nZVI. Recently, Datta et al. (2014) synthesized filter paper immobilized nZVI, that shows 64% Cr(VI) removal efficiency.

In an alternate approach cellulose has been used as a sustainable immobilizer has been utilized for various nanoparticles, including, TiO2 (Duan et al. 2015), Cu, Ni (Kotelnikova et al. 2007), silver, gold, platinum (Cai et al. 2008) and nZVI (Raychoudhury et al. 2012). However, its usage and applications in nZVI is limited in its study. The poor solubility of cellulose in water and organic solvents restricts their broad application. However, the dissolution of cellulose in ionic liquid (Swatloski et al. 2002; Zhu et al. 2006) has broadened its usage in various application including, fuel cell (Sajana et al. 2014), sensing (Hines et al. 2008), bioethanol (KleinKlein-Marcuschamer et al. 2011; Fitz-Patrick et al. 2010), environmental remediation (Liu et al. 2012), nanoelectronic devices (Seid et al. 2012). However, limited studies have been carried out in the synthesis of cellulose immobilized nanomaterials in the ionic liquid. Gelesky et al. (2009) synthesized Pt and Rh nanoparticle immobilized on cellulose acetate film using ionic liquid 1-n-Butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (BMI.NTf2). Similarly, magnetic cellulose-chitosan hydrogel has been synthesized using ionic liquid by Liu et al. (2012), which showed high removal efficiency for Pb2+, Fe2+ and Cu2+ ions.

Recently, we reported unusual adsorption of Cr(VI) up to 562.8 mg/g of nZVI by cellulose immobilized nZVI material synthesized in an aqueous medium (Sharma et al. 2015). Thus in continuation, the present study investigates the Cr(VI) adsorption characteristics of nZVI loaded cellulose (CI-1-3) synthesized by borohydride reduction with simultaneous co-precipitation of polymer from the ionic liquid.

Materials and methods

Microcrystalline cellulose Avicel PH-101® obtained from Sigma Aldrich (St. Louis, USA) and all other chemicals used in the study were of analytical purity. Deionized water was used for the preparation of chemical and reagent. Total chromium and hexavalent chromium in adsorption studies were determined using diphenylcarbazide method (APHA 2005). Iron estimation of CI-1-3 was carried out by phenanthroline method, upon HNO3/H2SO4 digestion of the sample (Harvey Jr. et al. 1955).

Physical characterization of cellulose immobilized nZVI (CI-1-3)

Fourier Transformed Infrared (FTIR) spectra of Microcrystalline Cellulose (MCC), dried CI-1-3 and chromium adsorbed CI-1-3 were recorded on an FTIR (BRUKER TENSOR 27). Transmission Electron Microscope (TEM) analysis was obtained on Technai200 kV TEM. Morphological characterization was carried out by Scanning Electron Microscope (FE-SEM) using Carl Ziess, Merlin Compact 6073. CI samples were coated with gold before the SEM analysis. Electron Dispersive X-rays spectroscopy (EDX) analysis performed on Oxford maxN. CI samples were coated with gold before the SEM analysis. Magnetization studies were performed on a Vibrating Sample Magnetometer (VSM) (Lakeshore Model: 7404, USA) with the maximum magnetizing field of 1.2 Tesla in an inert vacuum atmosphere. Thermogravimetric analysis (TGA) was carried out at a heating rate of 10 °C/min up to 500 °C using a Shimadzu TG-60H TG analyzer under N2 environment. Powdered X-ray diffraction (XRD) analysis was carried with CuKα radiation (kp = 1.54056 Å) and X-ray photoelectron spectroscopy (XPS) analysis (VG Multilab 2000-Thermo Scientific, UK, K-Alpha) with a multi-channel detector, which can endure high photonic energies from 0.1 to 3 keV). CHN elemental analysis for chromium adsorbed CI-2 was carried out using Thermo-Finningan elemental analyser. Chromium solution upon adsorption analysed by U–Vis Spectrophotometer at a wavelength of 540 nm.

Adsorption experiments

The adsorption experiments for Cr(VI) using CI-1-3 was carried out in triplicate. For this, a stock solution (1 mM) was prepared in deionized water by dissolving 294 mg of K2Cr2O7 in 1000 mL of deionized water. Standard Cr(VI) solution 1–10 mg/L, were prepared for adsorption study. To a 100 mL of Cr(VI) solution (1–10 mg/L), 10 mg of CI-1-3 were added and incubated at 25 ± 2 °C and 200 rpm for 24 h. The samples were filtered using Whatman filter paper 1 and analysed by the dipheylcarbazide method at a wavelength of 540 nm using U–Vis spectrophotometer. The optimization study was carried out for parameters like pH, dose and initial concentration. pH of the Cr(VI) solution was maintained at 3, 5, 7, 8 and 10 using 1 N HCl and/or NaOH solution at Cr(VI) concentration of 5 mg/L with a dose of 100 mg/L of CI-1-3. The dose experiment was carried out using 3 mg/L of chromium solution at the optimum of pH 3 with varying amount of CI-1-3 (50, 100, 200 and 400 mg/L).

Kinetic study of Cr(VI) by CI-1-3

Adsorption of Cr(VI) using CI-1-3 was analysed by contact time study for optimization of equilibration time and kinetics of adsorption. To a 100 ml solution of 20 mg/L Cr(VI) was added 10 mg of CI-1-3 and incubated at 25 ± 2 °C, 200 rpm for 24 h. A small aliquot was drawn and analyzed at various time intervals, i.e. 30, 60, 120, 180, 240, 360, 480, 600, 840 and 1440 min and diluted accordingly for analysis. The concentration of Cr(VI) adsorbed was plotted as a function of time. The data was studied for its pseudo-first order and pseudo-second-order kinetic behaviour.

Interference study for Cr(VI) adsorption by CI-2

To a 50 ml of 6 mg/L Cr(VI) solution was added the desired volume of stock solution of various salts. The solution was adjusted to pH 3 with makeup to give a 3 mg/L Cr(VI) with various salts were maintained at 10, and 100 mg/L and CI-2 amount of 200 mg/L were added and incubated at 25 ± 2 °C, 200 rpm for 24 h.

Regeneration study of chromium by CI-2

The chromium concentration of 1000 mg/L with 1 g/L of CI-2 was used for the regeneration study at pH 3 for 24 h at 25 ± 2 °C. After 24 h of reaction, the chromium solution was decanted from the CI-2 material. Without any further treatment, the CI-2 was used for adsorption of the chromium from a fresh Cr(VI) solution. The filterate was collected separately upon adsorption. The above said method was repeated 4 times with the residue containing CI-2, with fresh Cr(VI) solution. The filtrate collected were analyzed for Cr(VI) using phenanthroline method.

Result and discussion

Synthesis and characterization of CI-1-3

The ionic liquid [BMIM]Cl was prepared using the method reported by Crowhurst et al. 2003. The CI-1-3 was synthesized by dissolution of cellulose in [BMIM]Cl, a desired amount of FeCl3 followed by dropwise addition of aqueous NaBH4 to furnished CI-1, CI-2 and CI-3 (6, 12 and 24% w/w) with instantaneous reduction of iron with simultaneous precipitation of cellulose and nZVI (Scheme 1).

Scheme 1
scheme 1

Synthesis of microcrystalline cellulose immobilized nZVI (CI-1-3)

The iron content of the CI-1-3 were analyzed using phenanthroline method (Harvey Jr. et al. 1955). The analysis revealed iron loading in CI-1-3 to be 6.4, 12.02 and 24%, respectively. The result indicated the presence of iron in CI composite is proportional to the amount of FeCl3 used for synthesis.

Stability study of CI-1-3 and microcrystalline cellulose immobilized nZVI synthesized in water (C-nZVI)

CI-2 and C-nZVI (Sharma et al. 2015), respectively with 12% w/w iron loading on cellulose were studied for their stability upon a stay in groundwater sample (Fig. 1a). CI-2 was stable for 48 h, whereas C-nZVI turned brown in 10 h, i.e. an oxide of iron was formed in the presence of water. Apart from this CI-2 showed better air stability with more than a year shelf life (Fig. 1b), whereas C-nZVI was found to lose its activity within 30 days under ambient conditions. This stability of CI-2 over C-nZVI is accounted for the stabilization of iron nanoparticle by its immobilization in cellulose bulk.

Fig. 1
figure 1

a Stability of CI-2 and C-nZVI in tap water (pH − 8.15 TDS = 970 mg/L) upon standing for 48 h and b CI-2 after 90 days under ambient conditions

Characterization of microcrystalline cellulose immobilized nZVI (CI-1-3)

SEM analyses were carried out for the morphological characterization of cellulose immobilized zerovalent iron nanoparticle (CI-1-3) (Fig. 2a–c). SEM images of the CI-1-3 showed that the iron nanoparticles were immobilized on cellulose polymer. The size of the nZVI particles lie in the range of 20–100 nm and were spherical in shape. SEM image of CI-1 (Fig. 2a) showed that fewer nZVI particles were embedded on the cellulose surface with limited surface occupancy of nZVI on the polymer, leaving large surface area of polymer unoccupied due to the lower amount of iron. However, there is an increase in the density of nZVI on the surface of cellulose with lesser surface remaining unoccupied incase of CI-2. The nZVI were found to be agglomerated on the surface of cellulose due to the magnetic properties of Fe0 (Ponder et al. 2000) (Fig. 2b). Upon increasing the iron content to 24% w/w in CI-3, there is a significant change in the morphology and arrangement of nZVI on the cellulose surface. The iron particles were extremely agglomerated to form a plate-like structure on the surface of cellulose. Due to the high concentration of iron, the particles synthesized were submicron-sized particles, and no space was left unoccupied on the cellulose surface. The images suggest that water is a precipitating solvent for cellulose and addition of aqueous NaBH4 solution to the cellulose-Fe(II) solution in the ionic liquid lead to a reduction of iron and precipitation of cellulose simultaneously, thus leading to variedly embedded CI-1-3.

Fig. 2
figure 2

SEM images of a CI-1, b CI-2 and c CI-3; TEM images of d CI-1, e CI-2 and f CI-3

TEM analysis of CI-1-3 was carried out for the characterization of iron immobilization on the surface and core of cellulose. TEM images of CI-1-3 showed an embedding of nZVI on the cellulose framework (Fig. 2d–f), with increasing concentration of iron-loaded on to cellulose. The image of CI-2 shows chain like agglomeration of nZVI embedded in cellulose. This indicates the reduction of iron being faster than MCC precipitation. In comparison to CI-2, CI-3 showed increased deposition of iron on the surface of cellulose with fewer iron particles occupying the core of cellulose. This suggests that upon increasing the loading of iron, the precipitation of cellulose was faster than the reduction of iron. As the reduction occurs in two steps, whereby reduction of Fe(III) to Fe(II) is fast and spontaneous whereas further reduction of Fe(0) is slow. Thus, upon increasing the concentration of iron in CI-3, complete reduction of Fe(III) to Fe(0) does not take place to precipitate iron before the precipitation of cellulose, leading to superficial immobilization of iron onto cellulose.

FTIR studies were carried out for establishing the surface interaction between nZVI and Microcrystalline cellulose in CI-1-3 as given in Fig. 3. MCC was characterized by the presence of absorption bands at 3424 cm−1 which corresponds to hydrogen bonded hydroxyl groups (Lu and Hsieh 2010). Upon immobilization of nZVI on MCC, a shift in the absorption band with narrowing, centered at 3357, 3360 and 3400 cm−1, respectively, for CI-1, 2 and 3 were observed. This narrowing of the absorption band in this region shows the interaction of hydroxyl moieties of cellulose with nZVI in these materials. This interaction could be elaborated as of the kind Fe…..HO (Jones et al. 1998; He et al. 2007). The absorption band at 946 and 825 cm−1 incase of CI-1-2 is accounted to the shift in the C-Ostr due to the strong hydrogen bonded interaction between MCC and nZVI (Xiao et al. 2009). However, the adsorption band at 946 cm−1 is absent incase of CI-3 because of the high amount of iron create inter-particle interaction between iron thereby aggregating nZVI and compromising interaction between nZVI and MCC.

Fig. 3
figure 3

FTIR spectra of a MCC and CI-1-3, b CI-2 and Cr(VI) adsorbed CI-2, c magnetization curve of CI-2 and CI-2 after adsorption of Cr(VI), d XRD pattern of CI-2

The FTIR spectrum of chromium adsorbed CI-2, showed a band broadening in the region of 3000–3400 cm−1 corresponding to the weakening of hydrogen bonding between the nZVI and MCC. A band broadening at 1200 cm−1 corresponds to C-Ostr stretching. This suggests that due to change in the surface morphology of the iron nanoparticle, there is a significant change in the binding of the nZVI to the surface of the MCC (Sharma et al. 2015). The two characteristic absorption bands of C-Ostr at 946 and 825 cm−1 disappeared in case of CI-2 upon chromium adsorption. Further, a new absorption band was observed at 1740 cm−1 in case of chromium adsorbed CI-2, which is accounted to the carbonyl moiety. This carbonyl functional group suggests the formation of cellulose dialdehyde (Kim et al. 2004; Sharma et al. 2015). For the investigation of dialdehyde formation, CHN analysis of Cr adsorbed CI-2 was carried out upon oxime derivatization. The presence of 0.47% of nitrogen confirms the formation of dialdehyde upon adsorption of Cr by CI-2 (Fig. S7). Thus, it confirms the in situ reductive regeneration of nZVI in case of CI-2, similar to that reported for cellulose immobilized nZVI synthesized in a water medium (Sharma et al. 2015).

The magnetic property of CI-2 and its chromium adsorbed residue was verified by VSM studies as depicted in Fig. 3c. The saturation magnetization moment of Cr adsorbed CI-2 (6 emu/g) is higher than CI-2 (3 emu/g), which is less than that of nZVI (Jabeen et al. 2011). The material CI-2 shows superparamagentic property, that has no corecivity and residual magnetization (Dalla Vecchia et al. 2009). This could be accounted to the immobilization and encapsulation of nZVI by cellulose in the synthesis process, which upon Cr(VI) adsorption is regenerated by in situ reduction by cellulose which weakens the binding between the exposed cellulose–dialdehyde and nZVI leading to the characteristic increase in the magnetization.

The XRD pattern of CI-2 showed a characteristic peak of metallic iron (Fe0) at 2θ = 44.8° (index 110) on cellulose surface (Fig. 3d). Further, the reflections at 2θ = 22.7 and 35.0° suggest the existence of cellulose in cellulose-I crystalline form (Yu et al. 2013; de Morais Teixeira et al. 2010).

Thermogravimetric analysis (TGA) and differential thermogravimetric analysis

The thermal stability of CI-2 and CI-3 were studied and compared with Microcrystalline cellulose (MCC) by TGA and DTA analysis (Fig. 4a, b). MCC underwent thermal degradation in the temperature range of 300–350 °C (up to 90% weight loss) while CI-2 degraded in two stages in the temperature range of 270–280 °C and 300–345 °C. Similarly, CI-3 degraded in the temperature range of 290–370 °C in the first stage and 390–480 °C in the second stage. The degradation of CI-2–3 at lower temperature establishes its poor stability in comparison to MCC. The lower weight loss in case of CI-2 and 3 with respect to MCC at temperature > 350 °C, is due to the oxidation of Fe0 to Fe3O4 (Yadav et al. 2016; Yu et al. 2013). The difference in the degradation temperature of CI-2 and CI-3 is accounted to the presence of high amount of iron in CI-3. This high amount of iron creates agglomeration in CI-3, due to which outer iron surface is oxidized and prevents oxidation of iron core. A part of CI-2 and CI-3 degraded at a higher temperature, which is accounted to the oxidation of charred carbon residues on the oxidized iron. The residue left in case of CI-2 and CI-3 was 38 and 42%, respectively. The higher ash content in case of CI-3 is accounted to the higher loading of iron. However, the weight loss in case of CI-2 and CI-3 is lower than that of MCC, as char formation occur in the presence of iron. The Cr adsorbed CI-2 showed degradation similar to MCC. The Cr adsorbed CI-2 showed thermal degradation of cellulose in a narrow temperature range of 280–350 °C, which is significantly similar to the TG pattern of cellulose dialdehyde (Kim and Kuga 2001). There is no significant change observed up to 500 °C, which indicates that iron is in completely oxidized form. But the residual content was significantly higher as compared to CI-2 and MCC, which accounts for the oxidation of iron and adsorption of Cr(VI).

Fig. 4
figure 4

a TGA and b DTA analysis of MCC, CI-2 and CI-3 and Cr adsorbed CI-2

The DTA curve of MCC shows heat loss in the temperature range from 100 to 330 °C, further heat gain was observed at a temperature of 358 °C (Fig. 4b). Upon loading of iron on cellulose, incase of CI-2, heat gain was observed at a temperature of 275 and 405 °C. At a temperature interval of 450–500 °C, drastic heat loss was observed in case of CI-2, whereas, CI-3 showed heat loss at a temperature of 300 °C, further high heat loss was observed at 475 °C. The lower heat loss in CI-2 is due to the presence of lower amount of iron for oxidation as compared to CI-3. The agglomeration of iron on the cellulose surface prevents the cellulose oxidation. Upon adsorption of chromium on CI-2, a significant amount of heat loss was observed at a temperature of 315 °C, and in the temperature range of 475–500 °C. This suggests the formation of chromium-iron complex.

X-ray photoelectron spectroscopy (XPS) analysis

The XPS analysis of CI-2 and CI-3 in Fig. 5 shows depth profile of Fe0, Fe(II or III), O, C and Cr of the particles with 12 and 24% w/w of loading of iron without and with adsorbed chromium (Fig. 5a–d). For precise determination of the features of the peaks in each spectrum, all spectra are deconvoluted via Voigt curve fitting within the Shirley background. The photoelectron peak corresponding to the binding energy of Fe(2P3/2) and Fe(2P1/2) observed at 710.21 and 723.37 eV, respectively (Wen et al. 2014; Li and Zhang 2007), ascertains the existence of iron in the zero-valence state (Fe0). Pilot peaks at 716.02 and 731.40 eV correspond to the binding energy of Fe2O3 that reveals the nZVI surface was covered with a small layer of iron oxide. The binding energy peak, observed at 531.0 and 528.57 eV corresponds to the binding energy of OH group of cellulose and Fe–O layer of iron on the surface, respectively (Manning et al. 2007; Devan et al. 2011, 2016, 2017; Moulder 1992). The double peak features of C(1s) core level located at a binding energy of 284.7 and 286.6 eV confirm the presence of carbon on cellulose as C–C and C–O–C bond, respectively (Matuana et al. 2001). Moreover, the absence of Cr has been confirmed in CI-2 sample (Fig. 5d).

Fig. 5
figure 5

High-resolution XPS spectra for the core level of a C, b O, c Fe and d Cr for the sample CI-2

Upon adsorption of Cr onto CI-2 as well as CI-3, the photoelectron peak of Fe(2p) core levels showed no shift in the binding energy of Fe(2P3/2) and Fe(2P1/2), indicates the presence of Fe0 (Figs. 6a, 7a). Figure 6b depicts the peaks corresponding to core levels of Cr(2P3/2) and Cr(2P1/2) at a binding energy of 575.86 (Halada and Clayton 1991) and 585.49 eV (Li et al. 2008). However, the comparison of CI-2 with chromium adsorbed CI-2, showed an increase in the intensity of the peak located at a binding energy of 715.49 and 731.98 eV, respectively, corresponding to Fe(2P1/2) and Fe(2P3/2) of Fe(III/II), (Fig. 6a). This suggests the increase in the Fe(II/III) concentration in Cr adsorbed CI-2.

Fig. 6
figure 6

High-resolution XPS spectra of chromium adsorbed CI-2 (blue) and CI-3(black) depicting the binding energy spectrum of a iron, b chromium. (Color figure online)

Fig. 7
figure 7

High-resolution XPS spectra of chromium adsorbed CI-3 depicting the binding energy spectrum of a iron, b chromium and c oxygen

A comparison of CI-2 and Cr adsorbed CI-2 showed an increase in the intensity of binding energies corresponding to Cr, confirmed the presence of adsorbed chromium on the surface of the material (Figs. 5d, 6b). The peaks observed at a binding energy of 575.86 and 585.49 eV suggest the presence of chromium in the Cr(III) state. Thus, during adsorption of chromium onto CI-2, Fe0 is oxidized to Fe(II or III), reducing Cr(VI) in the solution to Cr(III) mmobilized on surface of nZVI immobilized on cellulose. This, in turn, leads to the formation of a precipitate of Fe(II or III)–Cr(III) oxide. Similar variation was observed for Cr(III) in case of chromium adsorbed CI-3 (Fig. 7b). Further, Cr adsorbed CI-3 showed a satellite peak at 531.72 eV and an intense peak at 530.11 eV, is attributed to OH and oxides, respectively in the material (Fig. 7c) (Devan et al. 2010; Moulder 1992). A comparison of the peak intensities of OH and oxide in CI-2 and chromium adsorbed CI-3 showed an increase in the intensity of the oxide peak and decrease in the intensity of hydroxyl peak. The increase in oxide indicates the oxidation of zero-valent iron as well as oxidation of cellulose. However, lowering of the intensity of binding energy peak corresponding to OH at 531.72 eV confirms the oxidation of cellulose or presence of hydroxyl groups in CI-2 (Devan et al. 2009).

Adsorption studies

Effect of pH on Cr(VI) adsorption

In adsorption process, pH plays a vital role, particularly for ionic species like Cr(VI). Thus, CI-2 was studied for the effect of pH on the Cr(VI) removal by reductive–adsorption in the pH range 3–10. The result of the adsorption, in terms of the Cr(VI) removal efficiency is as given in Fig. 8. The CI-2 was found to remove Cr(VI) with an efficiency of 36.8, mg/g at pH 3 which is reduced to 2.4 mg/g at pH 10 (Fig. 8a). Thus, the removal efficiency was observed to be maximum under acidic conditions. This could be explained by, the surface protonation of nZVI leading to positively charged surface favoring electrostatic interaction with Cr(VI) oxoanion (Jabeen et al. 2011). Further, the protonation of chromate ion reduces the anion-nZVI electrostatic repulsion thus facilitating adsorption at low pH (Gheju 2011; Li et al. 2008). But, as the pH increases, the availability of protons is significantly decreased reducing the electrostatic attraction between Cr(VI) and nZVI. It was further observed that CI-2 suspension is primarily black in color/appearance. It undergoes a significant change in the color upon treatment with Cr(VI) solution. This change of color signifies the oxidation of Fe0 to Fe(III) and formation of Cr(III)–Fe(III) hydroxide precipitates (Powell et al. 1995).

Fig. 8
figure 8

Effect of a pH by Cr(VI) = 5 mg/L, CI-2 = 100 mg/L, b initial Cr(VI) concentration = 1–10 mg/L, CI-2 = 100 mg/L, pH-3, c Langmuir and d Freundlic adsorption isotherm for CI-2-3 for adsorption of Cr(VI), e contact time using Cr(VI) = 20 mg/L, CI-2-3 = 100 mg/L, f effect of Vaious Anions and Cations in the concentration of 1 × 10−3 M on Cr(VI) (3 mg/L) adsorption by 100 mg/L of CI-2

Effect of dosage of CI-2 on Cr(VI) adsorption

The efficiency for Cr(VI) removal increased from 34.73 to 83.85%, upon increasing the CI-2 dosage from 50 to 100 mg/L as depicted in Fig. S3. However, when the dosage of CI-2 was further increased to 200 and 400 mg/L, there was a significant increase in the removal efficiency of Cr(VI) which reaches a saturation level at 91.92 and 93.68%, respectively. Thus, the optimum dose for the adsorption experiment was fixed at 100 mg/L Cr(VI) in an aqueous solution maintained at pH 3.

Effect of Cr(VI) concentration on adsorption by CI-1, 2 and 3

Cr(VI) adsorption was studied for CI-1-3 as shown in Fig. 8b. 100 mL of 1 to 10 mg/L range of chromium concentration were treated with 100 mg/L CI-1-3 at pH 3. The result showed CI-2 had higher removal efficiency than CI-3 followed by CI-1 (Table 1).

Table 1 Comparison of Langmuir and Freundlich constant for CI-1-3

Adsorption Isotherm studies

Langmuir and Frendulich adsorption isotherm were used to determine the adsorption equilibrium between the nZVI and Cr(VI). The adsorption behavior of CI-1-3 was carried out for Cr(VI) as given in Fig. 8c, d, which is fitted to a linear model of Langmuir and Freundlich isotherm using equation 1 and 2. The Langmuir and Freundlich adsorption isotherm was best fitted for Cr(VI) adsorption using CI-1-3. The isotherm of CI-2 and CI-3 showed a linear fit for the plot between 1/Ceq and 1/qe as shown in Fig. 8c. The isotherm plot for CI-3 is shown in supplementary Fig. S2. The maximum adsorption (qmax) was found to be 28.57, 58.82 and 38.48 mg of Cr(VI)/g for CI-1, 2 and 3, respectively (Table 2). The normalized adsorption value (qn) was calculated according to the percentage of iron loading on to CI-1-3 using equation given below:

$${\text{Normalized}}\,{\text{adsorption}}\,{\text{q}}_{{{\text{n}} }} = \frac{{{\text{q}}_{\text{e}} }}{{\% {\text{Fe}}}} \times 100$$

The normalized value for Cr(VI) is 476, 490 and 160 mg of Cr(VI)/g of nZVI for CI-1, 2 and 3, respectively. CI-2 showed higher normalized removal efficiency for Cr(VI) than CI-3, which is the optimum loading for the Cr(VI) adsorption. The higher removal efficiency of CI-2 is comparable to that of CI-1, which accounts for the retain surface dispersion and nZVI activity on the cellulose surface. However, in case of CI-3, the iron particles are aggregated on the surface of cellulose, thus lowering the interaction between nZVI and cellulose surface leading to lower adsorption efficiency.

Table 2 Kinetics constant for adsorption of chromium on CI-2 and CI-3

Kinetics equilibrium study

The removal efficiency for Cr(VI) (20 mg/L) increased from 4.18 to 47.74% upon increasing the contact time from 30 min to 24 h as depicted in Fig. 8e. The optimal removal efficiency was achieved at 11 h. In comparison to the literature on nZVI, the CI-3 showed slower Cr(VI) removal kinetics, which could be accounted to the lesser exposure of polymer embedded nZVI particles for adsorption of the Cr(VI).

The kinetic data showed best fit with the pseudo-second-order kinetic model for upon adsorption of Cr(VI) ions using CI-2 and CI-3 (Fig. S4 and S5). The result further showed that the rate constant was 9.2 × 102 and 2 × 102 g−1 mg−1 h for CI-2 and CI-3, respectively. The results indicate the better rate of adsorption by CI-2 to the extent of 4000 times better than that of CI-3. This may be accounted for the formation of micron-sized aggregates of iron.

Study of interference of ions on chromium adsorption

As CI-2 was prepared to immobilize and stabilize nZVI for groundwater and wastewater application. The CI-2 showed substantial adsorption for Cr(VI) from aqueous solution. Thus, it is essential to study the potential interference from major anions and cations present in the groundwater system. Thus, for the study of interference various anions using sodium salts of Cl, PO43−, SO42− and NO3 and cations using chloride salts namely Fe2+, Ca2+, K+ and Na+ in the concentration of 1 × 10−4, 1 × 10−3 and 1 × 10−2 M were used. The CI-2 dose of 200 mg/L were added to 3 mg/L of Cr(VI) solution containing 1 × 10−4, 1 × 10−3 and 1 × 10−2 M solution of various anions and cation maintained at pH 3. There was no significant change observed in the adsorption of Cr(VI) in the presence of anions; chloride and nitrate, and in presence cations, of Na+, K+, and Ca2+ as shown in Fig. S6. The effect of various anions and cations (1 × 10−3 M) is shown in Fig. 8f. However, anions PO −34 , SO42− and cation Fe2+, ions in the concentration of 1 × 10−3 M showed strong synergistic effect leading to the efficient removal of Cr(VI) ions. This synergistic effect could be accounted to the precipitation of the reduced chromium as Cr(SO4)3 and CrPO4, thus reducing the surface passivation of cellulose immobilized nZVI. The synergistic effect of Fe2+ ions could be accounted to the increased Cr(VI) reduction, subsequently followed by the adsorption in case of CI-2 (Kim et al. 2012).

Regeneration study of Cr(VI) by CI-2

In the regeneration study of Cr(VI) adsorption using CI-2, four successive generation of usage of CI-2 for Cr(VI) reductive adsorption was found to be significant. The result showed 44.63% of Cr(VI) removal in the first cycle which was reduced to 22.6% in the second cycle. The adsorption efficiency was lost significantly at third and subsequent cycles in the range 6.56–4.64% (Fig. 9).

Fig. 9
figure 9

Regenration study of cellulose immobilized nZVI composite CI-2 (1 g/L) for Cr(VI) (pH = 3, 1 L, 1 g/L, 24 h, 200 rpm) adsorption

Discussion

The significantly high adsorption efficiency of chromium by CI-1-3 is due to reductive regeneration of zerovalent iron as cellulose is oxidized to form dialdehyde which regenerate zerovalent iron. Upon comparison of the loading characteristics of the CI-1-3, an increase in Cr(VI) adsorption up to twofold upon increasing the iron loading on cellulose from 6 to 12% is observed. Further increase in iron loading to 24%, a significant drop in the adsorption capacity of material was observed in case of CI-3. This trend in Cr(VI) adsorption upon loading was compared for normalized adsorption, similar normalized adsorption was observed in case of CI-1 and CI-2, approximately with a threefold higher Cr(VI) adsorption in comparison with CI-3. This characteristic adsorption behaviour of CI-1-3 could be attributed to the particle size of nZVI as well as the maximum coverage on the surface of cellulose. The particle sizes of ZVI immobilized on cellulose were characterized by nanodimension in case of CI-1 and-2, whereas incase of CI-3 the ZVI were plate shaped with size ranging in submicron. Similar results reported by Uzum et al. (2009) and Yadav et al. (2016), where the immobilized nZVI showed an optimum adsorption up to a certain loading onto the immobilizer, were observed with various other adsorbates like Cu(II), Co(II), As(V) As(III) etc. Similar loading characteristics has been studied by Uzum et al. (2009) on Cu(II) and Co(II) ions adsorption using 50–20% w/w nZVI loaded Kaolinite, an increase in the normalized adsorption of Co(II) was observed upon decreasing the nZVI loading on kaolinite. On the other hand, the interactive surface coverage area for nZVI with cellulose could not be ruled out, as cellulose plays a vital role in the regeneration of nZVI during the adsorption of Cr(VI) oxoanion. Further investigations would be required to be carried out to establish the influence of interaction surface coverage between nZVI and cellulose on the adsorption of various heavy metals.

The performance of the material CI-2 was examine by comparing the results obtained in the present study with other adsorbent normalized for the nZVI loading is depicted in Table 3. With material CI-2 obtained normalized adsorption efficiency up to 490 mg/g of nZVI for chromium, which is higher than the nZVI based adsorbents as well as the polymer functionalized material.

Table 3 Comparative evaluation of adsorption capacity of chromium by various adsorbent

Conclusion

The materials CI-1-3 synthesize using ionic liquid–water binary mixture showed better water and air stability. The effect of iron loading and the application of these materials on the chromium adsorption were investigated. The material CI-2 containing 12% w/w iron showed highest removal efficiency than CI-3 (24% w/w) and almost equal efficiency as CI-1. This is accounted to the loading behavior of iron on the cellulose surface and reaction mechanism involving iron regenerate by in situ oxidation of cellulose. The CI-I (6% w/w) and CI-2 found to have suitably spread on the cellulose with the formation of spherically shaped nZVI. In case of CI-3, higher amount of iron lead to formation of micron size particles by aggregation of nZVI particles, which decreased the adsorption efficiency of the material for chromium. The experimental data were best fitted to Langmuir and Freundlich adsorption isotherm. The adsorption process reached the adsorption equilibrium at 11 h, and the data followed pseudo second order kinetic model.