Abstract
An inherent problem with microfluidic filters is the tendency to clog, especially when applied to cells due to their geometrical complexity, deformability, and tendency to adhere to surfaces. In this work, we handle live algal cells of high complexity without signs of clogging, achieved by exploiting hydrodynamic interactions around trilobite-shaped filtration units. To characterize the influence of cell complexity on the separation and concentration mechanisms, we compare the hydrodynamic interactions to those of synthetic, rigid microparticles. We discover that simple rolling along the filter structures, which prevents clogging for particles, cannot be applied to cells. Instead, we find that inertial effects must be employed to minimize the filter interactions and that this modification leads to only a minor reduction in device performance.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
A well established field in microfluidics is particle enrichment and fractionation (Beech et al. 2012; Lenshof and Laurell 2010; Sajeesh and Sen 2014), with many promising technologies such as filtration (Chen et al. 2014; Maria et al. 2015; Jiang et al. 2018), deterministic lateral displacement (Huang et al. 2004; Loutherback et al. 2010; Liu et al. 2010; McGrath et al. 2014), inertial microfluidics (Godino et al. 2015; Hood et al. 2016; Ghadami et al. 2017), and centrifugation (Morijiri et al. 2013; Al-Faqheri et al. 2017). Combinations of the above-mentioned methods have also been demonstrated (Marchalot et al. 2014; Jiang et al. 2016; Prabhakar et al. 2015; Kim et al. 2009). Owing to the ease of operation and scalability (Dijkshoorn et al. 2017), industrial applications range from algal harvesting (Barros et al. 2015; Olgae 2015), where high throughputs are essential, to more conventional lab-on-a-chip applications such as diagnostics (Nam et al. 2016; Warkiani et al. 2015; Maria et al. 2017). However, most of these technologies are developed to manipulate synthetic microspheres or simple, rigid cells such as yeast cells, and the ability to handle particles with a high degree of complexity in shape, deformability, and surface properties can, therefore, be limited.
For example, microfilters and cross-flow filters are commonly employed for concentration of sphere-like, fixed cells, but fibers and flagella of many living microorganisms including algal cells dramatically increase the risk of clogging due to agglomeration of biomaterial and fouling near the filter structures (Babel and Takizawa 2010). However, by utilizing hydrodynamic interactions to increase the apparent particle size, particles comparable in size to the pores can be directed away from the filter structures, which greatly reduce the tendency to clog. The most widely used technique to increase the apparent particle size is rotation. Sugaya et al. (2011) utilized velocity shear near the channel wall in a hydrodynamic filter to induce a tumbling mode for rods, which increased their virtual size. However, since rotation is most efficient in the absence of inertia, the achievable throughput of this method can be limited.
In a popular alternative to microfiltration called deterministic lateral displacement, cells are displaced laterally by the use of pillar obstructions. This method shows promising behavior for blood cell enrichment and for dewatering of micro-algae, but alignment with pillar structures reduces the degree of lateral drift which, in turn, reduces the separation efficiency (Beech et al. 2012). To hinder the alignment, Holm et al. (2011) suggested to use channels that were shallower than the diameter of disk-shaped blood cells, but reductions in the channel depth can lead to high-pressure losses and, hence, restricts the achievable throughput. In addition, low-velocity zones downstream of pillars can lead to agglomeration.
As an alternative to the above-mentioned techniques, the technology presented here instead employs the arrays of trilobite-shaped, cross-flow filtration units (Fig. 1) and was exploited by Dong et al. (2011) to enrich cancer cell with concentration ratios as high as 4. However, the throughput was only 2 ml/min and the applicability of this study to real-life situations is limited, since only fixed (dead) cells were used. In a more recent work, Honsvall et al. (2016) used the same trilobite filter to harvest both live and fixed micro-algae cells and reported successful enrichment for simple, rigid, sphere-like cells. However, attempts to concentrate complicated, non-spherical, or flexible cells were unsuccessful, because these either slipped through or clogged the filtration channels.
We have previously used a simplified version of the trilobite filter to demonstrate how hydrodynamic interactions between particles and tunable flow fields can be utilized to improve concentration and filtration performance and to hinder clogging (Mossige et al. 2016). By means of flow visualizations and velocimetry measurements (\(\upmu\)PIV), we identified optimal flow conditions. In our most recent article (Mossige et al. 2018), we implemented these flow conditions for size-based concentration and separation of synthetic microspheres with throughputs as high as 32 ml/min. Two distinctively different separation regimes were reported based on particle size and degree of inertia.
This article extends the previous works by demonstrating concentration of complex, live algal cells of varying size, shape, and deformability. While maximizing concentration ratios, we show that clogging is avoided and demonstrates the enrichment of cells which are smaller than the filter pores. These achievements are realized by utilizing the inertial effects, which are rarely exploited in microfluidic filters. We visualize cell trajectories by fluorescence imaging to characterize the interaction between algae, filter units, and flow fields. By comparison with results obtained using synthetic microspheres, we isolate the effect of shape, deformability, and surface properties on the separation dynamics and device performance. Finally, we utilize the difference in separation mode and inertia to separate flexible, rod-like cells from rigid, disk-like cells.
2 Concentration and separation principle for synthetic particles
Figure 1 shows how hydrodynamic principles around trilobite-shaped filtration units are utilized for concentration and separation. The filtrate flow is guided through slits (\(25\,\upmu \hbox {m}\)) between turbine blade-shaped pillars, while the separation particles, which are visualized by streaklines, are guided around the trilobites and directed onto a different outlet, where the concentrate is collected. These particles interact with the pillars; however, the strong shear flow in the accelerated flow region between trilobites induces particle rotation, which prevents clogging.
The combination of the incoming feed flow and the suction flow through the filtrate outlets creates a saddle point of converging streamlines (see Fig. 1b). In Mossige et al. (2016), we found that clogging can be prevented and that concentration ratios are maximized when the saddle point is positioned directly downstream of the trilobite unit, as is the situation in (b). Since the flow has to go around the trilobites, a filtration layer with thickness T is formed, and in Mossige et al. (2018), we showed that clogging is avoided when the flow is tuned, so that T is made smaller than the particle. As illustrated in (b), this flow configuration can be exploited to concentrate large (red) spheres and simultaneously separate them from green ones, which are smaller than the slits, because the latter type of particle simply follows the flow of filtrate.
By utilizing flow inertia, which is attained by increasing the feed flow rate, Q, it is possible to concentrate particles which are smaller than the slit width, and this principle is shown in (c) and in (d). Owing to inertial effects in (c), the particle cannot follow its associated streamline; instead, it bumps against the filtration pillars and is, thus, carried downstream without entering the filtration slits [see schematic in (d)]. This phenomenon is similar to the situation experienced by many frustrated golf players when the golfball has too much inertia to enter the hole without bouncing off. Farther downstream, when the ’golfball’ (green particle) approaches the trilobite rear end, the combination of high fluid inertia and streamline curvature leads to lateral migration away from the filter structures. Both golfball bouncing and lateral migration serve to increase the apparent (hydrodynamic) particle diameter above the size of the slit widths, because particles which are smaller than the slits are prevented from entering the filtrate. A drawback of this method compared to the low-velocity rolling used to concentrate the large red spheres in (b) is that the concentration ratio is reduced, due to the necessary reduction of the filtrate layer thickness T.
The array of 13 side-by-side trilobite separation units on the microfluidic chip used in this work (d) are distributed across the 10 mm-wide main channel (30 mm long and \(90\,\upmu \hbox {m}\) deep). Each trilobite is \(460\,\upmu \hbox {m}\) wide and \(1155\,\upmu \hbox {m}\) long. The filtrate liquid flows through the trilobite outlets and is directed out of the device through another channel underneath the row of trilobites. The inlet, ‘IN’, and concentrate outlet, ‘OUT’, are connected to the main channel via distribution channels and the chip is sealed with a 0.30 mm-thick glass slide.
3 Experiments
3.1 Experimental setup
The two parameters used to modify the flow fields and manipulate the migration of particles are the feed and filtrate flow rates, which are denoted as Q and \(Q_\mathrm{f}\), respectively. The filtrate flow layer, which has thickness T and dictates the cut-off size, is manipulated by tuning the ratio of these two flow rates. An increase in the relative amount of filtrate to feed fluid, \(Q_\mathrm{f}\)/Q, leads to a thickening of T, while a decrease leads to a thinning of T. A user-controlled pressure system (MFCS-EZ, Fluigent) is employed to modify the flow rates and these are controlled using laboratory scales (ML 303 T, Mettler Toledo) to weigh the accumulated liquid in respective reservoirs. The flow fields are easily reproduced, because the flow rates are proportional to the reservoir pressures, and the maximum achievable throughput with our system is 32 ml/min. Any signs of clogging are detected by continually monitoring the flow rates and by visually inspecting the filter during the experiments.
By illuminating particles by green light, produced by passing white light through an excitation filter (ZET532/10\(\times\), Chroma), they become fluorescent and emit a strong optical signal against the dark background. A beam splitter (z532rdc, Chroma) and an emission filter (HQ 580/60, Chroma) serve to further improve the optical signal by filtering out the excitation wavelengths. Live algae are intrinsically fluorescent, which allows us to study their dynamics without doping them with fluorescent material. Since doping leads to algal death, which dramatically changes their mechanical properties (for example, they generally become stiffer and more dense), it is preferred to avoid it if possible.
By capturing long-exposure images of algal cell and particle trajectories, we characterize the hydrodynamic interactions and separation mechanisms. We use an upright microscope (BX43, Olympus) in combination with a 10\(\times\)-objective (Olympus PlanC N 10 \(\times\) /0.25) and a CCD camera (pco.4000, pco) for imaging, and we determine the cell and particle concentrations by counting the number of cells inside equally sized drops (2 \(\upmu\)l) deposited onto glass slides. We calculate the concentration ratios as the number of particles in the concentrate fluid divided by the number of particles in the feed, measured per unit volume of fluid.
There is a 10\(\%\) uncertainty in the calculation of the enrichment ratio performances, where the main error contribution comes from uncertainties in determining the particle and cell concentrations. Temporal fluctuations and mass flow variations between experiments count for only 1\(\%\) of the uncertainty, due to repeatable and stable flow fields.
3.2 Algal cells used in the experiments
The algal cells, see Table 1 and Fig. 2, are chosen to maximize the variability in size, shape, and deformability. The two marine species, Prorocentrum minimum (M1) and Protoceratium reticulatum (M2), are nearly spherical; M1 (13 by \(17\,\upmu \hbox {m}\)) is smaller than the \(25\,\upmu \hbox {m}\) filtration slits, and M2 (29 by \(30\,\upmu \hbox {m}\)) is larger than the slits, while the two freshwater species, Cryptomonas rostratiformis (F1) and Micrasterias truncata (F2), have complex shapes; F1 is rod-shaped (19 by \(41\,\upmu \hbox {m}\)) and F2 is disk-shaped (37 by \(77\,\upmu \hbox {m}\)). Furthermore, M1, M2, and F2 are rigid, while F1 is flexible, and cell type M1, M2, and F1 are swimming organisms (for more information about the motility of cells, see the "Appendix").
3.3 Calibration using test particles
Prior to the algae cells experiments, we verified the system for separation and concentration of rigid polymer beads (Cospheric LLC, CA, USA), called ‘test spheres’, with the following mean diameters: 21, 24, 32 and \(69\,\upmu \hbox {m}\), see Table 2. Since these particles are neutrally buoyant in the immersion medium, which is DI water, their hydrodynamic interactions with the flow fields are not influenced by density differences, which can give rise to additional inertial contributions. Live algal cells, on the other hand, are typically somewhat heavier than their immersion medium (Table 1), but, since this density difference is typically only about \(5\%\) (Kamykowski et al. 1992), these contributions are weak. Consequently, the effects of density differences were well within the \(\sim 10\%\) measurement uncertainty of the experiments, and thus, comparison between particles and cells was feasible.
By finding the minimum applied inflow that ensured concentration without clogging for each of the four test particle sizes, we identified maximum concentration ratios (CR). The results are presented in Table 2. By employing a least square fit to the four data points, CR was found to be proportional to the particle diameter squared, and hence, concentration efficiency increases rapidly with size. Test particles smaller than pores were concentrated by inertial migration, and spheres larger than pores were concentrated by low-velocity rolling along the filtration pillars. The applied flow rates that maximized CR served as reference for the subsequent testing with complex algal cells.
Long-range hydrodynamic interactions can increase the effective viscosity of the fluid. Since an increase in viscosity reduces particle inertia, which must be maintained to ensure maximized concentration performance (maximized CR), high particle concentrations can reduce the device performance. By comparing flow fields obtained with test particles to flow fields obtained without using test particles, we found that adding particles did not alter the flow fields. This convenient result is mainly due to the low particle concentrations in the feed fluid (\(< 10^{-4}\) by weight, see Table 2), ensuring that long-range hydrodynamic interactions between particles are negligible. For these calibration measurements, we performed streakline visualizations using \(1\,\upmu \hbox {m}\) tracers that follow the fluid flow accurately.
4 Results
4.1 Cell enrichment
- M1: :
-
Figure 3a, b shows trajectories of the sphere-like M1 cells, which are visualized by streaklines. In (a), these small cells (13 by \(17\,\upmu \hbox {m}\)) follow the flow of filtrate passively through the filtration slits, because the velocity is too low to induce lateral drift, which is necessary for separation from the filtrate stream and, hence, to concentrate them. In (b), the velocity is increased to about 2 m/s, achieved by employing the maximum feed flow rate of 32 ml/min. The velocity increase leads to lateral drift away from pillars in the downstream (curved) region of the trilobite filtration units due to increased inertia. However, a finite number of cells still slipped through the slits between the first pillars, because the velocity was not sufficiently high to trigger the golfball effect, which is used to bounce particles away from pillars and into the bulk flow.
- M2: :
-
Figure 3c shows the result of an attempt to concentrate the larger M2 cell (29 by \(30\,\upmu \hbox {m}\)) by low-velocity rolling along pillars, which is the method used to concentrate large test particles. As is evident from the image, interactions between cells and pillar structures lead to clogging, especially in the upstream region. Hence, interactions with pillars resulting from attempts to roll the cells over filtration pillars must be avoided. In (d), the velocity is increased compared to the situation in (c). The velocity increase induced the lateral drift of cells, which, in turn, reduced the degree of pillar interactions and thus served to prevent clogging.
- F1: :
-
Figure 4 shows trajectories of the rod-like F1 cell. In (a), the cells simply follow the flow through the pillar slits, because the velocity is too low to separate them from the filtrate stream. In (b), the velocity is increased, which lead to lateral migration across streamlines in the downstream region and hence to successful concentration of cells. However, during impact with pillars, these flexible cells deform instead of being deflected into the bulk flow by means of golfball migration. Therefore, although high velocities were employed, there was still a finite amount of cells that slipped through the first filtration gaps, as is evident from the visualization in (b).
- F2: :
-
Figure 5a shows an attempt to concentrate disk-shaped F2 cells by low-velocity rolling over the filtration pillars, which is the separation technique used for large test particles. The applied flow rate, 10 ml/min, is the same as was used to concentrate \(69\,\upmu \hbox {m}\) particles, which are comparable in size to the diameter of these disk-shaped cells (\(77\,\upmu \hbox {m}\)). However, since these cells are pushed against the trilobite head, by a favorable pressure gradient near the stagnation point, they align with the wall, and thus, any tendency to roll is suppressed. An unfortunate result of the alignment is clogging of the first filter slit, since the cells slide along the trilobite, while passively following the filtrate flow. Although the clogged cell seen in the image prevents further clogging by deflecting the other cells into the bulk stream, an increase in the inflow rate is required to remove clogging altogether.
In (b), the flow rate is increased to \(Q=18\,\hbox {ml/min}\), which is the flow rate used to concentrate \(32\,\upmu \hbox {m}\) test spheres, which are comparable in size to the cell thickness (\(37\,\upmu \hbox {m}\)). The velocity increase from (a) to (b) leads to a strong shear flow as well as to an adverse pressure gradient near the first filtration pillars [see also the cartoon in (d)]. The combination of these two mechanisms induces in-plane rotation (forward flipping), which results in a new orientation of the cell, where the largest cell face is now pointing against the incoming flow. A strong lift force resulting from the new orientation pushes the cell away from pillars and into the accelerated flow region between trilobites. Further downstream, the cell experiences out-of-plane rotation and resumes the orientation which it held the upstream of the trilobite unit.
Carefully conducted experiments showed that the velocity in (b) was higher than necessary to avoid clogging. Thus, clog prevention was possible with lower inflow rates than the employed \(Q = 18\,\hbox {ml/min}\), and hence, an increase in concentration ratio was possible. In (c), the critical inflow rate is used, \(Q_\mathrm{critical} = 14\,\hbox {ml/min}\). With \(Q_\mathrm{critical}\), the velocities were still sufficiently high to induce in-plane cell rotation, which is necessary to prevent clogging; however, the rotation occurs farther downstream than in (b).
4.2 Performance of cell enrichment
Figure 6a is a plot of the maximum achievable CR without clogging. The red dots are the data points obtained using test particles (21, 24, 32, and \(69\,\upmu \hbox {m}\)) and the solid line is a second-order fit to the obtained four data points, showing excellent agreement (\(R^2 = 0.9997\)). An attempt to achieve higher CR than is indicated by the solid line would result in clogging, because it can only be achieved by reducing the inflow rate. The maximum achievable CRs for algae are indicated by image symbols and circles; images indicate longest algae dimension and circles indicate shortest dimension.
Comparisons of the hydrodynamic diameters of cells to the physical dimensions (width, length, and diameter) enable the evaluation of the effect of cell complexity, e.g., different shapes, on the concentration performance. For example, when the hydrodynamic diameter is larger than the physical dimensions, it means that the cell shape helps to increase the CR, while if the hydrodynamic diameter is smaller than the physical measures, then the opposite is true. By convention, the CR of an algal cell with hydrodynamic diameter of \(a_\mathrm{H}\) is exactly equal to that of a test sphere with diameter of a. The CR curve was used to calculate \(a_H\), by the method shown in (b), and the results are presented in (c). Comparisons between the virtual and physical dimensions of algae are presented in Table 3.
4.2.1 Cells with simple shapes
For sphere-like M2 cells (29 by \(30\,\upmu \hbox {m}\)), the hydrodynamic diameter is smaller than the physical dimensions, which means that the CR is not as high as that of a rigid sphere of similar size. The reason for the efficiency deficit is that the M2 cell cannot be concentrated by low-velocity rolling over the filtration pillars as these types of interactions lead to clogging, which is most likely due to the particularly rough cell surface. To avoid clogging, the degree of pillar interactions must be reduced, and therefore, the M2 cell must be concentrated by lateral migration instead of rolling, which is attained by employing high flow velocities. Unfortunately, the required velocity increase necessary to obtain the sufficient amount of inertia leads to a slight reduction in CR, caused by the resulting thinning of the filtrate layer (Table 4).
For the small M1 cell (13 by \(17\,\upmu \hbox {m}\)), the hydrodynamic diameter is larger than the physical dimensions, which indicates that the cell complexity actually increases the concentration efficiency. However, this positive result should be read with some skepticism, since it was found by extrapolation; the test sphere diameters used to create the CR curve range from 69 to \(21\,\upmu \hbox {m}\), while the M1 cell is 13 by \(17\,\upmu \hbox {m}\), which is outside this range of particle sizes.
4.2.2 Cells with complex shapes
The hydrodynamic diameter of the rod-like F1-cell is \(22.2\,\upmu \hbox {m}\), and the similarity with the width (\(19\,\upmu \hbox {m}\)) indicates that influences of the length (\(41\,\upmu \hbox {m}\)) on the concentration mechanism are secondary; however, they are not negligible. The similarity with the width is due to alignment with the upstream body of the trilobite, resulting from a favorable pressure gradient, causing the smallest cell length (the width) to face the incoming flow.
Also for the disk-shaped F2 cell, the concentration ratio is dictated by the shortest cell dimension, seen as the almost identical value of the width, w, and \(a_\mathrm{HYD}\). Again, the reason for this similarity is alignment with the trilobite head, which causes the cell to slide along the wall, with the smallest cell face pointing against the direction of the flow. The alignment suppresses any tendency of the cell to flip or rotate to increase its hydrodynamic diameter beyond its width.
4.3 Comparison with previous work and prospects of upscaling
As mentioned in the Introduction, higher concentration ratios than reported in Table 3 were demonstrated by Dong et al. (2011), using a modified version of our microfluidic device. However, the focus of our work is enrichment of complex cells without clogging, achieved by employing tunable flow fields, rather than maximization of concentration ratios. Another important difference between our works is the total number of employed trilobites. While Dong et al. (2011) made use of as much as 700 units, yielding a concentration ratio of 0.005 per trilobite, only 13 units were used in the current experiments, yielding a value of 0.09 for the same performance metrics. Thus, our work represents an improvement.
To further enhance the concentration performance of our design, one could simply add rows of trilobites. To compensate for the removal of fluid through the additional trilobite filter outlets, one could make use of a contracting main channel to maintain the velocities needed to prevent clogging.
Finally, owing to the simple chip layout, the technology has potential for parallelization. A substantial increase in throughput is, therefore, possible, which enables implementation in industrial processes where several cubic meters of fluid are processed every minute. Industries where high throughputs are essential include micro-algal harvesting and ocean tech industries with applications such as micro-plastic removal.
4.4 Cell sorting
The results of cell enrichment using individual algal cells are strong indications that fractionation from a mixture of different species is possible. To test this hypothesis, we mixed large test spheres with small test spheres and performed fractionation. This initial testing was followed by sorting of real cells, and the results were then compared to study the effect of cell complexity on the fractionation performance.
4.4.1 Calibration and validation with test spheres
Figure 7a shows a streakline visualization where 32 and \(69\,\upmu \hbox {m}\) spheres were successfully separated from \(21\,\upmu \hbox {m}\) spheres. With the employed feed flow rate, \(Q = 21\,\hbox {ml/min}\), the velocities were sufficiently high to induce clog-preventing rolling over the pillars for \(32\,\upmu \hbox {m}\) spheres. Note that the filtration layer T was also approximately \(32\,\upmu \hbox {m}\), which marks the clog-free cut-off size. Since the \(69\,\upmu \hbox {m}\) spheres were much larger than the cut-off and due to the increased inertia as compared to \(32\,\upmu \hbox {m}\) spheres, they were not able to follow streamlines. Consequently, they followed a more or less straight trajectory around the trilobite-shaped filtration units. In stark contrast to the large \(69\,\upmu \hbox {m}\) spheres, the smaller \(21\,\upmu \hbox {m}\) spheres accurately followed the flow, because the velocities were too low to induce inertial migration across streamlines and away from the filter units. Hence, \(21\,\upmu \hbox {m}\) spheres were carried by the filtrate through the filtration slits. As a convenient result of the difference in inertia and separation mode for different particle sizes, small particles were effectively separated from their larger counterparts without the signs of clogging.
Optimally, the velocities used for fractionation are sufficiently high to prevent clogging of large particles, yet small enough that the inertial effects are negligible for small particles, allowing them to follow the filtrate flow passively. In the case of negligible inertia, there is no concentration of small particles, resulting in an equal number of particles in the filtrate, concentrate, and feed solutions, measured per unit volume of fluid. The results obtained using rigid, simple test spheres show no measurable difference in particle concentration between inflow, concentrate, and filtrate, which implies complete separation of particles (100\(\%\) efficiency).
A major strength of the reported separation technology and employed operation is that the filtrate flow is insensitive to changes in feed flow rate. As reported in Mossige et al. (2018), the filtrate flow is constant and equal to 2 ml/min regardless of inflow rate, which is considered as high for microfluidic separators. With a volumetric concentration of particles of \(10^{-4}\) in the feed, which is a common concentration, 40,000 particles of size \(21\,\upmu \hbox {m}\) are separated per minute.
4.4.2 Fractionation of complex cells
To verify that our geometry can be used to sort the live algal cells of distinctively different shape, size, and deformability, we mixed soft, rod-like F1-cells with rigid, disk-like F2-cells in the inflow and performed fractionation, see the streakline visualizations in Fig. 7b. We applied the flow rate required to concentrate the latter type of cell by separation from the filtrate stream without clogging, namely \(Q=14\,\hbox {ml/min}\). Our results show that no clogging occurred and that there were no F2 cells in the filtrate, which is to be expected as these cells are larger than the slits.
The streakline visualization shows that the rod-shaped F1 cells followed the filtrate stream passively through the filtration slits, which is because the velocity is sufficiently low that inertial effects were small. However, due to some degree of pillar interactions caused by the fact that the cell is longer than the slit width (length is \(41\,\upmu \hbox {m}\), while slits are \(25\,\upmu \hbox {m}\)), there were 13\(\%\) fewer cells per unit volume in the filtrate than in the feed. Hence, the separation efficiency was 87\(\%\), which is comparable to the separation efficiency obtained using rigid spheres (100\(\%\) efficiency).
With 16,000 F1 cells per milliliter of feed fluid, a filtration flow rate of 2 ml/min, and a separation efficiency of 87\(\%\), the fractionation rate is close to 28,000 cells per minute. With smaller cells than the F1 cell, for example with the M2 cell, even higher fractionation rates can be expected due to an increased number of cells in the feed fluid and higher separation performance, because these cells follow the flow more accurately.
5 Conclusion
A separation technology consisting of trilobite-shaped filters was used for enrichment and sorting of four types of live algae cells which were distinctively different in size, shape, and deformability. The flow was tuned to maximize concentration ratios without clogging. Optimal flow conditions were identified for each cell type by means of streakline visualizations and controlled flow rate measurements.
Unlike synthetic microspheres, algal cells cannot be concentrated by low-velocity rolling along the filter structures, since these interactions lead to clogging. Instead, inertial flow fields are employed to achieve cross-streamline migration and golfball bouncing away from the filters. For one of the species in our study, namely the sphere-like M2 cell, the high flow rate needed to obtain the sufficient amount of inertia to prevent clogging leads to a slight reduction in concentration ratio because of a reduction in the ratio of filtrate to feed fluid. However, for the remaining three cells types, including complex rod-shaped and disk-shaped cells, the obtained performances were comparable to that of synthetic particles, when evaluated by the shortest cell dimension.
Finally, differences in the degree of inertia and deformation during impact with pillars were utilized to sort large disk-shaped algal cells from small, flexible rod-like cells. The smaller rod-like cells were sorted at a rate of 28,000 cells per minute, conserving the excellent fractionation characteristics reported previously for synthetic microspheres.
References
Al-Faqheri W, Thio THG, Qasaimeh MA, Dietzel A, Madou M, Al-Halhouli A (2017) Particle/cell separation on microfluidic platforms based on centrifugation effect: a review. Microfluid Nanofluidics 21(6):102. https://doi.org/10.1007/s10404-017-1933-4
Babel S, Takizawa S (2010) Microfiltration membrane fouling and cake behavior during algal filtration. Desalination 261(1):46–51. https://doi.org/10.1016/j.desal.2010.05.038. http://www.sciencedirect.com/science/article/pii/S001191641000353X
Barros AI, Gonçalves AL, Simões M, Pires JC (2015) Harvesting techniques applied to microalgae: a review. Renew Sustain Energy Rev 41:1489–1500. https://doi.org/10.1016/j.rser.2014.09.037. http://www.sciencedirect.com/science/article/pii/S1364032114008107
Beech JP, Holm SH, Adolfsson K, Tegenfeldt JO (2012) Sorting cells by size, shape and deformability. Lab Chip 12:1048–1051. https://doi.org/10.1039/C2LC21083E
Chen CC, Chen YA, Liu YJ, Yao DJ (2014) A multilayer concentric filter device to diminish clogging for separation of particles and microalgae based on size. Lab Chip 14:1459–1468. https://doi.org/10.1039/C3LC51345A
Dijkshoorn J, Schutyser M, Wagterveld R, Schroën C, Boom R (2017) A comparison of microfiltration and inertia-based microfluidics for large scale suspension separation. Sep Purif Technol 173:86–92. https://doi.org/10.1016/j.seppur.2016.09.018. http://www.sciencedirect.com/science/article/pii/S1383586616317099
Dong T, Yang Z, Su Q, Tran NM, Egeland EB, Karlsen F, Zhang Y, Kapiris MJ, Jakobsen H (2011) Integratable non-clogging microconcentrator based on counter-flow principle for continuous enrichment of caski cells sample. Microfluid Nanofluidics 10(4):855–865. https://doi.org/10.1007/s10404-010-0717-x
Edvardsen B, Moy F, Paasche E (1990) Hemolytic activity in extracts of Chrysochromulina polylepis grown at different levels of selenite and phosphate. In: Granéli E, Sundstrøm B, Edler L, Anderson DM (eds) Toxic marine phytoplankton. Elsevier, New York, pp 284–289
Eppley R, Holmes R, Strickland J (1967) Sinking rates of marine phytoplankton measured with a fluorometer. J Exp Mar Biol Ecol 1:191–208
Ghadami S, Kowsari-Esfahan R, Saidi MS, Firoozbakhsh K (2017) Spiral microchannel with stair-like cross section for size-based particle separation. Microfluid Nanofluidics 21(7):115. https://doi.org/10.1007/s10404-017-1950-3
Godino N, Jorde F, Lawlor D, Jaeger M, Duschl C (2015) Purification of microalgae from bacterial contamination using a disposable inertia-based microfluidic device. J Micromech Microeng 25(8):084002. http://stacks.iop.org/0960-1317/25/i=8/a=084002
Holm SH, Beech JP, Barrett MP, Tegenfeldt JO (2011) Separation of parasites from human blood using deterministic lateral displacement. Lab Chip 11:1326–1332. https://doi.org/10.1039/C0LC00560F
Honsvall BK, Altin D, Robertson LJ (2016) Continuous harvesting of microalgae by new microfluidic technology for particle separation. Bioresour Technol 200:360–365. https://doi.org/10.1016/j.biortech.2015.10.046. http://www.sciencedirect.com/science/article/pii/S0960852415014492
Hood K, Kahkeshani S, Di Carlo D, Roper M (2016) Direct measurement of particle inertial migration in rectangular microchannels. Lab Chip 16:2840–2850. https://doi.org/10.1039/C6LC00314A
Huang LR, Cox EC, Austin RH, Sturm JC (2004) Continuous particle separation through deterministic lateral displacement. Science 304(5673):987–990. https://doi.org/10.1126/science.1094567. http://www.sciencemag.org/content/304/5673/987.abstract. http://www.sciencemag.org/content/304/5673/987.full.pdf
Jiang M, Mazzeo AD, Drazer G (2016) Centrifuge-based deterministic lateral displacement separation. Microfluid Nanofluidics 20(1):17. https://doi.org/10.1007/s10404-015-1686-x
Jiang Y, Yu Z, Huang X, Chen R, Chen W, Zeng Y, Xu C, Min H, Zheng N, Cheng X (2018) A multilayer lateral-flow microfluidic device for particle separation. Microfluid Nanofluidics 22(4):40. https://doi.org/10.1007/s10404-018-2053-5
Kamykowski D, Reed RE, Kirkpatrick GJ (1992) Comparison of sinking velocity, swimming velocity, rotation and path characteristics among six marine dinoflagellate species. Mar Biol 113(2):319–328. https://doi.org/10.1007/BF00347287
Kim HC, Park J, Cho Y, Park H, Han A, Cheng X (2009) Lateral-flow particle filtration and separation with multilayer microfluidic channels. J Vac Sci Technol B Microelectron Nanometer Struct Process Meas Phenom 27(6):3115–3119. https://doi.org/10.1116/1.3258155
Kotai J (1972) Instructions for preparation of modified nutrient solution Z8 for algae. Publication 8-11169. Norwegian Institute for Water Research, Blindern, Norway
Lenshof A, Laurell T (2010) Continuous separation of cells and particles in microfluidic systems. Chem Soc Rev 39:1203–1217. https://doi.org/10.1039/B915999C
Liu L, Loutherback K, Liao D, Yeater D, Lambert G, Estevez-Torres A, Sturm JC, Getzenberg RH, Austin RH (2010) A microfluidic device for continuous cancer cell culture and passage with hydrodynamic forces. Lab Chip 10:1807–1813. https://doi.org/10.1039/C003509B
Loutherback K, Chou KS, Newman J, Puchalla J, Austin RH, Sturm JC (2010) Improved performance of deterministic lateral displacement arrays with triangular posts. Microfluid Nanofluidics 9(6):1143–1149. https://doi.org/10.1007/s10404-010-0635-y
Marchalot J, Fouillet Y, Achard JL (2014) Multi-step microfluidic system for blood plasma separation: architecture and separation efficiency. Microfluid Nanofluidics 17(1):167–180. https://doi.org/10.1007/s10404-013-1296-4
Maria MS, Kumar BS, Chandra TS, Sen AK (2015) Development of a microfluidic device for cell concentration and blood cell-plasma separation. Biomed Microdevices 17(6):115. https://doi.org/10.1007/s10544-015-0017-z
Maria MS, Chandra TS, Sen AK (2017) Capillary flow-driven blood plasma separation and on-chip analyte detection in microfluidic devices. Microfluid Nanofluidics 21(4):72. https://doi.org/10.1007/s10404-017-1907-6
McGrath J, Jimenez M, Bridle H (2014) Deterministic lateral displacement for particle separation: a review. Lab Chip 14:4139–4158. https://doi.org/10.1039/C4LC00939H
Morijiri T, Yamada M, Hikida T, Seki M (2013) Microfluidic counterflow centrifugal elutriation system for sedimentation-based cell separation. Microfluid Nanofluidics 14(6):1049–1057. https://doi.org/10.1007/s10404-012-1113-5
Mossige EJ, Jensen A, Mielnik MM (2016) An experimental characterization of a tunable separation device. Microfluid Nanofluidics 20(12):160. https://doi.org/10.1007/s10404-016-1826-y
Mossige EJ, Jensen A, Mielnik MM (2018) Separation and concentration without clogging using a high-throughput tunable filter. Phys Rev Appl 9(054):007. https://doi.org/10.1103/PhysRevApplied.9.054007
Nam J, Shin Y, Tan JKS, Lim YB, Lim CT, Kim S (2016) High-throughput malaria parasite separation using a viscoelastic fluid for ultrasensitive pcr detection. Lab Chip 16:2086–2092. https://doi.org/10.1039/C6LC00162A
Olgae (2015) Comprehensive report on attractive algae product opportunities. http://www.oilgae.com/ref/report/non-fuel-algae-products.html
Prabhakar A, Kumar YVBV, Tripathi S, Agrawal A (2015) A novel, compact and efficient microchannel arrangement with multiple hydrodynamic effects for blood plasma separation. Microfluid Nanofluidics 18(5):995–1006. https://doi.org/10.1007/s10404-014-1488-6
Sajeesh P, Sen AK (2014) Particle separation and sorting in microfluidic devices: a review. Microfluid Nanofluidics 17(1):1–52. https://doi.org/10.1007/s10404-013-1291-9
Sugaya S, Yamada M, Seki M (2011) Observation of nonspherical particle behaviors for continuous shape-based separation using hydrodynamic filtration. Biomicrofluidics 5(2):024103. https://doi.org/10.1063/1.3580757
Warkiani ME, Tay AKP, Khoo BL, Xiaofeng X, Han J, Lim CT (2015) Malaria detection using inertial microfluidics. Lab Chip 15:1101–1109. https://doi.org/10.1039/C4LC01058B
Acknowledgements
This project was funded by Trilobite Microsystems A/S and The Research Council of Norway—Project number 232148. Support was also received from the Norwegian micro- and nanofabrication Facility (NORFAB) infrastructure project. All measurements were conducted at the Hydrolab at the Department of Mathematics at the University of Oslo in Norway. Thanks to SINTEF MiNaLab for manufacturing the microfluidic chips, to Vladyslava Hostyeva at NIVA and Bente Edvardsen at Department of Biosciences, UiO, for providing the algal cultures and the growth media. Also thanks to Rita Amundsen at Department of Biosciences, UiO, for overlooking the cultures. Thanks to our lab engineer Olav Gundersen for assistance with the pressure system and to Dag Dysthe at the Department of Physics (UiO) for lending us the camera, and thanks to Lailai Zhu in the Complex Fluids group at Princeton University for general feedback on the manuscript.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Appendix
Appendix
1.1 Swimming behavior of algae
The marine dinoflagellates (M1,M2) have two flagella and have a helical swimming pattern. C. rostratiformis (F1) has two flagella, the forward with thin hairs is dragging the cell forward while erected. Figure 8 shows trajectories of the fastest swimmer used in this study, namely algae of P. reticulatum (M2). Figure 8a was obtained using a 4 \(\times\) objective and Fig. 8b was obtained using a 10 \(\times\) objective, and the exposure time of both images was 5 s. Based on the length of the streaks, the swimming speed is estimated to \(\sim 0.15\,\hbox {mm/s}\), which is negligible compared to the speed of cells in the flow field around the separation units (\(\sim 2\,\hbox {m/s}\)). Therefore, the swimming activity of cells used in this study does not influence the separation dynamics.
To be able to be stationary in the liquid without sinking or rising and to ease the task of swimming, the densities of the swimming organisms are only about \(5\%\) higher than that of water. The F2 cell is not a swimmer, but its disk-shaped body enables migration across streamlines, which allows it to be easily transported by whirls and currents over large distances. To fully exploit this transportation method, this cell is also nearly neutrally buoyant.
1.2 Algal cultures
The micro-algae used in this study were obtained from the Norwegian Culture Collection of Algae. The marine dinoflagellates P. minimum (strain UIO 089) and P. reticulatum (strain UIO 232) were isolated from the Oslofjorden, Skagerrak, Norway, in 1986 and 2001, respectively. The freshwater micro-algae M. truncata (strain NIVA-CHL 34) was isolated from River Storelva, Ringerike, in S. Norway in 1978 and C. rostratiformis (strain NIVA-3/81) from Lake Helgetjernet in 1981.
The marine cultures were grown in the algal medium IMR \(\frac{1}{2}\) medium (Eppley et al. 1967), supplemented with 10 nM selenium (Edvardsen et al. 1990) with salinity of 25 PSU. The freshwater algal strains were grown in the medium Z8 (Kotai 1972) or a modified Z8 medium. The media were sterilized by pasteurization at \(80\,^{\circ }\hbox {C}\) for 20 min. All four strains were grown at \(16\,^{\circ }\hbox {C}\) under fluorescence white light with an irradiance of approximately \(50\,\upmu \hbox {mol}\) photons/\(\hbox {m}^{2}/\hbox {s}\), and a 14h:10h light:dark cycle. They were grown as batch cultures in 5 l Erlenmeyer flasks and harvested in the exponential or beginning of stationary growth phase.
Rights and permissions
About this article
Cite this article
Mossige, E.J., Edvardsen, B., Jensen, A. et al. A tunable, microfluidic filter for clog-free concentration and separation of complex algal cells. Microfluid Nanofluid 23, 56 (2019). https://doi.org/10.1007/s10404-019-2209-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10404-019-2209-y