1 Introduction

Microfluidic systems are used in many applications, including medical testing, drug delivery, chemical analysis, chip cooling, etc. These systems have the advantages of small volume, low cost, high throughput analysis. The small fluid volumes are often pumped and controlled or otherwise manipulated in these systems (Laser and Santiago 2004). Micropumps are essential components in the microfluidic systems and are used to manipulate, transport and control the precise quantity of fluid in terms of microlitre and millilitre (Singh et al. 2015). Micropumps play a crucial role in drug delivery applications by transporting the drug from the drug reservoir to the target place with high performance, accuracy and reliability (Wang and Fu 2018). Micropumps have been developed on various principles for many different applications viz. drug delivery and biomedical assays.

Recently, various micropumps are reported which are based on different actuation mechanisms and principles involving piezo-electric, electro-magnetic, electro-osmotic, shape memory alloy, electrostatic, etc. (Sen et al. 2007; Amirouche et al. 2009; Zhou and Amirouche 2011). Among various actuation mechanism, the piezoelectric (PZT) actuation offers several advantages such as large stroke displacement, fast response time and compact in design. However, it has a low force which can be improved by using a stack actuator. A model of valveless micropump which consists of a chamber and different diffuser designs was analyzed (Stemme and Stemme 1993). A flat walled planar design with the nozzle/diffuser arranged in the same plane as that of the pump chamber was studied (Olsson et al. 1995). The flow rate and pressure characteristics were studied using simulation as well as experiments for biometric piezoelectric pump (de Lima et al. 2009). PMMA and PDMS based micro diffuser/nozzle were fabricated and characterized for the flow and pressure profiles across the elements (Chen et al. 2003, 2008). The micropump performance characteristics have been investigated with respect to dimensions, membrane and actuator materials using the multi-field analysis with ANSYS CFX (Nisar et al. 2008). An experimental study of nozzle/diffuser micropump design using some novel no-moving-part valves was carried out to find an improved design of nozzle/diffuser valves (Yang et al. 2012). The driving performance of the piezoelectric actuator has been simulated using ANSYS software, and the relationship between structural parameters and center displacement/frequency of piezoelectric actuator have been obtained (Guo et al. 2012). PDMS based electromagnetically actuated valveless micropump was fabricated and detailed analysis of the magnetic actuation force and the flow rate of the micropump was carried out (Yamahata et al. 2005). A shape memory alloy (SMA) actuator and PDMS elastic tube were used to realize a simple peristaltic micropump design (Sassa et al. 2012). The deflected behaviour of unimorph circular piezoelectric diaphragm actuators under electrical loading was investigated. Further, factors which affect actuators performance were thoroughly examined (Mo et al. 2006). The deflection of a circular diaphragm in case of a PZT actuator having a smaller diameter than the diaphragm was discussed (Dau et al. 2009). Valveless diaphragm micropumps employ diffuser/nozzle elements with the direction-dependent flow. Further, the diffuser efficiency and the flow rectification ability is dependent on principle dimensions of the diffuser including divergence angle, diffuser length and neck width. Hence, the shape optimization of the microfluidic pump using fluid–structure interaction (fsi) module in COMSOL Multiphysics (Pawar et al. 2016). Numerical modelling of PDMS micropump behaviour using the FSI along with viscoelastic material model which is the appropriate assumption for PDMS material was demonstrated (Gidde and Pawar 2017). Design optimization of an electromagnetic actuation-based valveless micropump for drug delivery application using fsi module and validation of optimal electromagnetic valveless micropump using experimental analysis were carried out (Gidde et al. 2019).

From the above literature survey, it is evident that simulation and experimental based analysis of piezo-electric actuation based valveless micropumps have been addressed previously by researchers. Although, considerable work on piezoelectric actuation based valveless micropump, investigations based on fully coupled electro-fluid–structural (pzd and fsi physics interface) interactions is not performed till date due to the complexities in respect of coupling two physics. This paper focuses on the investigation of piezoelectric actuation based valveless micropump to find optimal design configuration of the micropump. The proposed study is divided into six sections including problem formulation, computational formulation, simulation and parametric studies, results and discussion, limitations of the piezoelectric micropump and conclusions.

2 Problem formulation

2.1 Working principle

Figure 1 illustrates the principle of working of valveless micropump. Based on diaphragm deflection (upward/downward), there are two modes namely supply and pump modes during one cycle. In the supply mode, the diaphragm deflects in upward direction which creates a negative pressure inside the chamber.

Fig. 1
figure 1

Working principle of a valveless micro-pump

During this mode of operation, the fluid flows into the chamber through the inlet and outlet. However, the loss of kinetic energy in the forward direction (diffuser action) is less than that of loss of kinetic energy in the reverse direction (nozzle action). Consequently, the fluid entering from the inlet is more than the fluid entering from the outlet. Therefore, the fluid is supplied into the chamber from the inlet. During the pump mode, the diaphragm deflects in downward direction which increases the pressure of the fluid inside the chamber. As a result, the fluid from the chamber exits through the inlet and outlet. However, the fluid exiting from the outlet is more than the fluid exiting from the inlet as a result of the difference in the loss of the kinetic energy in the forward and reverse direction. Further, the difference in the pressure drop across the nozzle and diffuser elements during one cycle causes a flow rectification (Liu et al. 2011).

2.2 Optimization methodology

Micropumps’ capability to transport or manipulate or control fluid in accurate volume along with the likelihood of integration with other systems depends upon design parameters viz. structural, functional and operating parameters. The structural design parameters and operating parameters are detailed in Table 1. The optimization methodology used to find the optimal values of design parameters and operating conditions is depicted in Fig. 2.

Table 1 Geometrical parameters and their ranges
Fig. 2
figure 2

Optimization methodology

Simulations are carried out to find optimal design parameters for the valveless micropump. In this study, the effect of the principle dimensions of the diffuser element including diffuser angle, diffuser length, neck width, and pump chamber depth and chamber diameter, and thickness of diaphragm on the micropump characteristics such as flow rate and back pressure is analyzed. Finally, the micropump with the optimal parameter set of dimensions is studied for the flow rate and back pressure performance characteristics.

2.3 Micropump performance characteristics

To enhance the micropump performance, the number of parameters need to be optimized. The maximum flow rate and maximum back pressure are the most important output performance characteristics of the micropump. The maximum flow rate is the volume of fluid per unit time delivered by the pump at zero back pressure whereas the maximum pressure the pump can work is known as the maximum back pressure. Often, the maximum flow rate is obtained when the pump is working at zero back pressure. At the maximum back pressure, the flow rate of the pump becomes zero wherein the back pressure opposes the work done by the pump.

Flow rectification efficiency is one of the vital aspects considered in the design of a valveless micropump. It depends upon the flow in forward and reverse direction through the diffuser/nozzle element during one cycle. Accordingly, the flow rectification efficiency of the valveless micropump is expressed using Eq. (1) as given below (Singhal et al. 2004):

$$ {\eta_r} = \frac{{{Q_+ } - {Q_- }}}{{{Q_+ } + {Q_- }}} $$
(1)

where ηr is the flow rectification efficiency of the micropump. Q+ and Q are fluid flow in the forward direction and fluid flow in the reverse direction, respectively. Thus, the flow rectification efficiency of the micropump manifests the ability of the micropump to generate flow in a preferential direction. The flow rate is calculated using Eq. (2) as given below (Gidde et al. 2019):

$$ {Q_{net}} = \frac{1}{2}\mathop \int \limits_0^T {Q_{outlet}} - {Q_{inlet}} $$
(2)

The difference between the outlet pressure and inlet pressure is known as back pressure. In other words, back pressure or pressure head is defined as the difference between the heads at the outlet and the inlet (Nguyen and Wereley 2006).

$$ {h_{max}} = {Z_{outlet}} - {Z_{inlet}} $$
(3)

2.4 Piezoelectric actuator

Piezoelectric materials generate electrical charge when stress is applied known as direct piezoelectric effect and mechanical strain when an electrical field is applied known as converse piezoelectric effect. PZT actuators convert electrical voltage into mechanical displacement. PZT actuators are divided in three basic categories namely, axial actuators (mode: d33), transversal actuators (mode: d31), flexural actuators (mode: d31). These actuators are used as vital components in various electromechanical systems. On the basis of application, the actuator configuration can vary greatly. Axial and transversal piezoelectric actuators have high stiffness and can be optimized for controlled movements and high forces.

In case of transversal piezoelectric actuators, electrical field/charge is applied in thickness direction and mechanical strain/stress in direction of plane is produced (Kanda et al. 2017). This converse piezoelectric effect is utilized for actuating micropump diaphragm. Displacement in radial direction occurs when voltage is applied to an actuator. When this displacement is blocked, a blocking force (a measure of the stiffness of actuator) is developed. As a result of this blocking force, diaphragm gets deflected in upward and downward direction during suction and pump mode of the micropump. Figure 3 shows a schematic of piezoelectric actuator composed of a PZT layer, a brass substrate, glue/epoxy layer and a PDMS diaphragm.

Fig. 3
figure 3

Schematic of three dimensional piezoelectric actuator

3 Computational formulation

The brief description of the numerical modelling of the piezoelectric valveless micropump is described in this section. COMSOL Multiphysics 5.0 was used to model the piezoelectric valveless micropump which is capable of performing fluid flow analysis using piezoelectric (pzd) and fluid–structure interaction (fsi) Multiphysics interface modules.

3.1 Model geometry

The schematics of a piezoelectric actuation based valveless micropump is presented in Fig. 4. The depth of the pump chamber and the nozzle-diffuser elements is H. A piezoelectric actuator comprises different elements namely a brass disc of thickness tbr as supporting layer and piezo element of thickness tpzt and diameter dpzt which is glued to the diaphragm using epoxy glue layer of thickness te.

Fig. 4
figure 4

Schematic of front view and top view of a piezoelectric actuation based valveless micropump

3.2 Governing equation

The two physics interface modules namely, piezoelectric devices (pzd) for the electro-structural parts and fluid–structure interaction (fsi) for fluid and structure domains, (Revathi and Padmanabhan 2016) respectively were used to model the whole piezoelectric actuation based valveless micropump. The piezoelectric actuator consists of the piezoelectric disc and the thin elastic plate of brass material. Using AC voltage, the radial strain is generated in a piezoelectric disc which will cause the surface of the brass plate glued with the piezoelectric disc to bend. Consequently, deflection occurs in the PDMS diaphragm of a valveless micropump. The magnitude of deflection of diaphragm is small in comparison with the its diameteter. Hence, it is governed by small deflection theory of plates. The governing equation of the transverse deflection for the elastic pump diaphragm can be expressed as (Cui et al. 2008).

$$ {D_f}{\nabla^4}W\; + \;{\rho_d}\frac{{{\partial^2}W}}{{\partial {t^2}}} = {f_{act}} - P $$
(4)

where,

$$ {D_f} = \;\frac{{E{t_d}^3}}{{12\left( {1 - {\nu^2}} \right)}} $$
(5)

Df is the flexural stiffness, ∇4 is the 2-dimensional double Laplacian operator, E is the Elastic modulus, ν is the Poisons ratio of the diaphragm material, td is the thickness of the diaphragm, and ρd is the density of the diaphragm material. fact is the periodic actuating force due to the strain of the actuator, and P is the dynamic pressure exerted on the diaphragm by the liquid. In this case, the pump diaphragm is assumed to be clamped to the brass plate. The flow is considered as an incompressible laminar flow, which can be described using the Navier–Stokes Eq. (6) and the mass continuity Eq. (7) (Fan et al. 2005).

$$ {\rho_f}\frac{D\vec V}{Dt} = \;{\rho_f}\vec g + \mu {\nabla^2}\vec V - \nabla P $$
(6)
$$ \;\;\;\;\frac{{\partial {\rho_f}}}{\partial t} + \;\left( {\vec V\;.\nabla } \right){\rho_f} = 0 $$
(7)

where, ρf is the density of the liquid; \( \overrightarrow V \) is the velocity vector; μ is the viscosity of the liquid.

3.3 Boundary conditions

The fixed and zero displacement boundary conditions were applied at the edges of the diaphragm. To ensure zero relative motion at the interface between the diaphragm, layer of epoxy glue, brass disc and PZT element the “always bonded boundary condition” has been employed. The PZT element is actuated using a sinusoidal voltage (Singh et al. 2015).

$$ V\left( t \right) = {V_o}\sin \left( {2\pi {f_{act}}t} \right)\; $$
(8)

The pressure boundary condition is employed at both inlet and outlet, and a no-slip boundary condition is applied at the walls. The working fluid used for the simulation is assumed to be incompressible, and the flow of fluid within the micropump is assumed as laminar one.

4 Simulation and parametric studies

A detailed discussion on the grid independency test, micropump operation, flow rectification, influence of design parameters on the flow rate, response of optimal design configuration of micropump to the pressure flow characteristics and influence of voltage on the flow rate are described in this section. Three-dimensional simulations of the piezoelectric simulations are performed using pzd and fsi interface modules to determine the optimal set of dimensions and the operating conditions. The two domains namely, structural domain and fluid domain were coupled and meshed using grid system consisting of hexahedral elements. Simulations were run for few cycles to confirm about cycle-to-cycle variation in performance characteristics of the micropump. The grid independency test was carried out for the base model with the dimensions depicted in Table 2. Accordingly, results of the diaphragm deflection and flow rate at sinusoidal voltage of 50 V (peak-to-peak) and actuation frequency of 100 Hz were compared.

Table 2 Physical and geometrical parameters of the piezoelectric valveless micropump employed in simulations

Four grid refinement levels were compared during grid independency test and the comparison is shown in Table 3. The error is estimated by using Eq. (9) (Xia et al. 2016).

Table 3 Grid independency test at actuating voltage and frequency of 50 V and 100 Hz, respectively for diaphragm deflection and flow rate
$$ \% \;error = \left| {\frac{{{F_2} - {F_1}}}{F_1}} \right| \times 100 $$
(9)

where F1 is the value of diaphragm deflection/net flow rate for the finest grids and F2 is the value of diaphragm deflection/net flow rate for other grids. It can be observed that the  % errors for diaphragm deflection and net flow rate are 0.06% and 0.34%, respectively between grid systems 3 and 4. Based on this, the grid composed by hexahedral elements having maximum size and minimum size of 0.116 mm and 0.0125 mm, respectively was used to carry out simulations.

Figure 5 shows deflection contours of the diaphragm across its diameter i.e. transient analysis at 0.0025 s and 0.0075 s during supply mode and pump mode wherein maximum deflection of the diaphragm occurs. Here, the diaphragm deflection is maximum at the center and zero at the edges as expected conceptually. During the supply mode, the diaphragm deflects in upward direction and fluid enters from both inlet and outlet through diffuser elements. During the pump mode, the diaphragm deflects in downward direction and subsequently fluid exits from the inlet and outlet through diffuser elements.

Fig. 5
figure 5

Contours of diaphragm deflection across its diameter a upward direction and b downward direction

It can be observed from Fig. 6 that the fluid entering through diffuser/nozzle element at the inlet during the supply mode is more than that of the flow exiting during the pump mode as a result of flow rectification caused as a result of difference in the pressure drop across nozzle and diffuser elements.

Fig. 6
figure 6

Simulation results of flow through diffuser/nozzle: velocity vectors a the flow entering into the chamber through diffuser element (Q+) at the inlet and b the flow exiting from the chamber through diffuser element (Q) at the inlet

The variation in deflection of diaphragm as a function of time at 50 V with 100 Hz actuating frequency i.e. transient response of diaphragm deflection for two cycles is represented in Fig. 7. It is noted that the diaphragm deflection is more in supply mode as compared to the diaphragm deflection in pump mode. The maximum diaphragm deflection is 2.4966 µm at 0.0025 s during supply mode. However, its magnitude is slightly decreased during pump mode and is 2.4891 µm at 0.0075 s. This decrease in maximum diaphragm deflection during pump mode is due to the presence of the fluid within the pump chamber. Additionally, the flow rectification can be clarified with the help of the transient response of flow rate through inlet and outlet during supply and pump modes as shown in Fig. 8. It clearly reveals that during the supply mode (Time period: 0 to 0.005 s), the fluid entering through the inlet (Q+) into the pump chamber is more than the fluid entering through the outlet (Q) into the pump chamber. In contrast, during the pump mode (Time period: 0.005 to 0.01 s), the fluid leaving through the outlet (Q+) is more than that of the fluid leaving through the inlet (Q).

Fig. 7
figure 7

Transient response: diaphragm deflection versus time during two cycles at actuation voltage of 50 V with actuation frequency of 100 Hz

Fig. 8
figure 8

Transient response: flow rate through the inlet and outlet as a function of time during two cycles at actuation voltage of 50 V with actuation frequency of 100 Hz

4.1 Influence of parameters on the flow rate

The influence of the various design parameters on the net flow rate needs to be studied to identify the optimal design parameters for the micropump. Hence, the response of the various design parameters to the net flow rate is discussed in this section.

The flow rate as a function of divergence angle is represented as shown in Fig. 9a. It can be observed that for the smaller values of divergence angle, the flow rectification through diffuser element is low as resistance offered by nozzle and diffuser is same. The net flow rate increases with increase in the value of divergence angle. This trend is continued up to 2θ ≤ 9 for the range of divergence angle studied here (6° to 12°).

Fig. 9
figure 9

Parametric studies: flow rate as a function of a divergence angle, b diffuser length, c neck width, d chamber depth, e chamber diameter and f diaphragm thickness, at actuation voltage of 50 V with actuation frequency of 100 Hz

However, at much higher divergence angles, i.e. 2θ > 9°, a decrease in the net flow rate occurs which may due to the flow separation. Hence, the divergence angle of 9° is found to be optimum. The influence of the diffuser length, Ld on the net flow rate is shown in Fig. 9b. The deviation in flow resistance between the nozzle and diffuser elements is less at lower values of diffuser length, Ld. This results in very low flow rectification accordingly the net flow rate is decreased. In line with this, the pressure drop also increases at higher values of Ld. Consequently, the net flow rate starts decreasing beyond diffuser length of 1.2 mm. Hence, the optimum nozzle-diffuser length Ld is 1.2 mm. The influence of the neck width, Wn on the net flow rate is shown in Fig. 9c. The net flow rate is found to be less at lower values as well as at the higher values of neck width. This trend in net flow rate is due to the chocking effect at lower values of neck width and flow separation effect at higher values of neck width. Hence, the optimal value of the neck width is 100 µm.

Pump chamber diameter and depth are the two critical geometrical parameters which affect flow rate capability of the mechanical micropump. The response of the chamber depth, H to the net flow rate has been studied by varying the chamber depth in the range 100–400 µm in the step of 50 µm as shown in Fig. 9d. The flow rate increases with the increase in chamber depth up to specific value due to the reduction in the flow losses. However, larger chamber depth prevents complete transfer of energy from the diaphragm into the fluid present in the pump chamber due to the increased damping characteristic as a result of more fluid. Here, flow rate reduces with increase in the chamber depth beyond 300 μm. The response of pump chamber diameter on the net flow rate is depicted in Fig. 9e. An increase in the chamber diameter also improves the flow rate due to increase diaphragm’s swept volume. It can be clarified using Eq. (10) as given below (Singh et al. 2015):

$$ {{\Delta }}V = \frac{\pi }{6}{W_o}D_c^2 $$
(10)

where, Wo denotes the total maximum deflection of the diaphragm. In order to minimize the dead volume, pump chamber diameter should be kept minimum (Nguyen and Wereley 2002).

It is important to note that the pump chamber diameter cannot increase beyond particular limit due to certain space and size related constraints which in turn limits the size of the micro-devices. Further, small diameter facilitates pump to be used in Lab on a Chip application. Hence, for proposed design, the optimal pump chamber diameter is 12 mm.

The net flow rate as a function of diaphragm thickness is presented in Fig. 9(f). The diaphragm thickness has linear relationship with the net flow rate, i.e. with increase in diaphragm thickness, the net flow rate decreases. This is due to the fact that the deflection of the diaphragm reduces with the increase in the thickness as the thicker diaphragm has more resistance to deflect. Further, it is well known that the swept volume of the diaphragm is a function of diaphragm deflection which in turn determines the amount of fluid pumped. However, diaphragm thickness cannot reduce beyond a certain limit due to the problems arising from self-sagging and stiction of the diaphragm surface (Mohith et al. 2018) and it would be difficult to manufacture thin diaphragm of thickness around 100 µm and also it would be to handle as well. There may be possibility of reliability issues under fatigue conditions. Hence, in the proposed micropump design, the thickness of the diaphragm is selected to be 150 µm.

4.2 Optimal micropump design configuration

In the previous section, the influence of micropump’s geometrical parameters on the net flow rate is analysed. The optimal and other fixed design parameters used to carry out characterization of the micropump are given in Table 4.

Table 4 Optimal and fixed design parameters

The two performance characteristics namely, the net flow rate and the back pressure are used to characterize the performance of the micropump. In fact, the influence of the actuation frequency on the net flow rate needs to be studied to determine the required operating conditions. It is required to achieve the desired flow for particular microfluidics application.

4.3 Pressure flow characteristics

The flow rate delivered by micropump is dependent on the various geometrical as well as operating parameters including the ratio of actuating frequency and natural frequency of the diaphragm, density of the working fluid and diaphragm, size of nozzle/diffuser elements, size of the chamber and size of the diaphragm. The resonant frequency of the diaphragm based micropump decrease with the nozzle/diffuser slenderness ratio and it increases with divergence angle of the diffuser/nozzle, high aspect ratio, and thickness ratio (Zhou and Amirouche 2009). Initially, at actuation voltage of 50 V (peak to peak value), the influence of actuating frequency within the range 0–175 Hz on the flow rate has been investigated.

The simulation result in terms of the flow rate as a function of actuation frequency is depicted in Fig. 10. At the beginning, the flow rate increases with the increase in the actuation frequency. The flow rate reaches a maximum value of 20 µl/min at an actuation frequency of 150 Hz and beyond fact= 150 Hz, the flow rate decreases. The trend of initial increase in the flow rate up to 150 Hz frequency can be elucidated with the help of simulation results for pressure inside the pump chamber at different actuation frequency as shown in Fig. 11. These results indicate that the pressure applied to the diaphragm and consequently pressure inside the micropump chamber increases with increase in the frequency (Singh et al. 2015). This is due to the fact that the force generated by the piezoelectric actuator increases with the actuating frequency (Revathi and Padmanabhan 2018).

Fig. 10
figure 10

Water flow rate as a function of actuation frequency at zero backpressure

Fig. 11
figure 11

Transient response: variation of pressure inside the micropump chamber as a function of actuating frequency for 100 Hz, 125 Hz and 150 Hz, respectively during one cycle

The maximum flow rate with zero back pressure is observed at the actuation frequency of 150 Hz. By keeping voltage and other parameters constant, for the actuation frequency beyond 150 Hz, the sudden decrease in the flow rate is observed. This is due to the fact that the maximum displacement of the diaphragm is much larger at the resonant frequency than at frequencies lower or higher than the resonant frequency of the actuating mechanism. This higher displacement results in higher swept volume consequently flow rate is more at 150 Hz and decreases beyond the 150 Hz. Further, small damping is observed at actuation frequency equal to the natural frequency of the actuating mechanism.

In practical applications, the flow characteristics with respect to back pressure are of significant importance and are different due to change in the layout of microfluidic systems used in different applications. Hence, the influence of back pressure on the flow rate was investigated at actuation frequency of 150 Hz and sinusoidal voltage of 50 V (peak-to-peak). The pressure flow characteristics of micropump are represented in Fig. 12. The results indicate micropump’s capability in terms of maximum flow rate and maximum back pressure. At the zero back pressure, the maximum flow rate observed is 20 µl/min, whereas a back pressure of 200 Pa is observed. Further, the effect of excitation voltage on the maximum flow rate and back pressure has been studied and accordingly pressure flow characteristics are represented as shown in Fig. 12.

Fig. 12
figure 12

Water flow rate as a function of back pressure

With increasing the excitation voltage, the flow rate increases to 24 µl/min at zero back pressure and maximum back pressure of 225 Pa can be attained. This is clarified with the help of diaphragm deflection as a function of actuation voltage shown in Fig. 13.

Fig. 13
figure 13

Transient response: intensification in diaphragm deflection as a function of actuation voltage at constant actuating frequency of 150 Hz for two cycles

Here, the diaphragm deflection at actuation voltage of 70 V is higher than that of its magnitude corresponding to the 50 V. Hence, the net flow rate delivered by the micropump can be varied with respect to the application by controlling the actuation voltage to the piezo-actuator. This adjustable flow rate characteristic of the piezoelectric micropump makes it a suitable candidate for drug-delivery applications.

5 Limitations of piezoelectric micropump

The exciting voltage of the piezoelectric actuators is proportional to the size and is limited in practical work. The displacement, force, and actuating voltage are vital parameters in case of the piezoelectric actuator (Nguyen and Truong 2004; Park et al. 2013; Pan et al. 2015; Zhang et al. 2013). Most piezoelectric diaphragm micropumps utilize a piezo disk which directly glued on the pump diaphragm. The piezo disc works in the quasi-static state. Consequently, both operating frequency and the volume change of the micropump induced by the diaphragm deflection are small. For improving the performance of piezoelectric actuators, effective methods are adopted, which includes increasing actuation frequency and raising the amplitude of the displacement. Consequently, enhanced performance can be achieved at a higher frequency. Another approach includes increasing the actuating voltage to increase the amplitude. However, the excitation voltage also has a limit. Hence, these micropumps require more sophisticated driver electronics.

6 Conclusions

In this paper, the numerical investigation of three Dimensional piezoelectric actuation based valveless micropump is reported. It is well-intentioned that the micropump performance characteristics namely flow rate and back pressure are predominately influenced by geometrical parameters as well as operating conditions. The micropumps' performance can be enhanced through proper choice of geometrical and operating conditions.

Based on the extensive simulations performed in this study, the following conclusions are drawn which highlight the findings in respect of proposed piezoelectric actuation based valveless micropump:

  1. 1.

    Simulation results of velocity vectors at diffuser/nozzle configuration show that the flow entering into the pump chamber through the inlet during the supply mode is more as compared to the flow exiting the inlet during the pump mode. This represents flow rectification property of the nozzle/diffuser elements.

  2. 2.

    In a nutshell, it is clear that the micropump performance is affected by principal dimensions of nozzle/diffuser, pump chamber dimensions and diaphragm dimensions. There are certain threshold values of these parameters which are required for desired performance.

  3. 3.

    The dimensions of optimal diffuser/nozzle geometry are divergence angle = 9°, diffuser length = 1.2 mm and neck width = 0.100 mm. The optimal chamber depth is found to be 300 µm. On the basis of space and size constraints of Microfluidic Chip/Lab on a Chip devices, the specified values for chamber diameter and diaphragm thickness are 12 mm and 150 µm, respectively.

  4. 4.

    The initial increment in flow rate with respect to actuation frequency up to the fundamental frequency of an optimal micropump design configuration has been observed. This increase has been clarified in terms of increase in pressure inside the pump chamber with increase in the frequency from 100 to 150 Hz.

  5. 5.

    On the basis of simulation results, for optimal design configuration, the maximum flow rate observed is 20 µl/min when operating at actuation voltage and actuation frequency of 50 V and 150 Hz, respectively with zero back pressure. Further, the micropump is capable to attain the maximum back pressure of 200 Pa.

  6. 6.

    For the actuation voltage and actuation of frequency of 70 V and 150 Hz, respectively, the maximum flow rate observed is 24 µl/min at zero back pressure and the maximum back pressure of 225 Pa is attained. This intensification in micropump’s characteristics is due to increase in diaphragm’s deflection, which in turn results in higher swept volume.

  7. 7.

    Voltage-based flow rate characteristics facilitate its suitability for drug delivery applications.

7 Future studies

In this regards, an attempt can be made to understand effect of diaphragm material, design, geometry and loading method on the pressure flow charcteristics.