Abstract
Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction is an important problem after creation of shunts. Most commonly, TIPS recanalization is performed via the jugular vein approach. Occasionally it is difficult to cross the occlusion. We describe a hybrid technique for TIPS revision via a direct transhepatic access combined with a transjugular approach. In two cases, bare metal stents or polytetrafluoroethylene (PTFE)-covered stent grafts had been placed in TIPS tract previously, and they were completely obstructed. The tracts were inaccessible via the jugular vein route alone. In each case, after fluoroscopy or computed tomography-guided transhepatic puncture of the stented segment of the TIPS, a wire was threaded through the shunt and snared into the right jugular vein. The TIPS was revised by balloon angioplasty and additional in-stent placement of PTFE-covered stent grafts. The patients were discharged without any complications. Doppler sonography 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites. We conclude that this technique is feasible and useful, even in patients with previous PTFE-covered stent graft placement.
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Transjugular intrahepatic portosystemic shunt (TIPS) is an effective treatment to control the sequelae of portal hypertension [1]. However, shunt dysfunction is a common problem, arising in up to 50% of patients when bare metal stents are used [2]. It is less frequent in case polytetrafluoroethylene (PTFE)-covered stent graft were used [3], but may occur in 17% of patients treated with covered stents [4]. The standard shunt revision technique is angioplasty or additional stent placement via the jugular vein approach; however, the access to the shunt is sometimes difficult [5].
We describe our experience with two cases in which an occluded TIPS, inaccessible via the jugular vein route, was recanalized by transhepatic direct puncture of the TIPS tract combined with a transjugular pull-through technique.
Case 1
A 68-year-old woman had undergone TIPS in December 1998 to treat primary biliary cirrhosis complicated by ruptured esophageal varices. Two overlapping bare metal stents (8 mm/65 mm and 10 mm/65 mm; Easy Wallstent; Boston Scientific, Natick, MA) had been placed in the TIPS tract from the right portal vein into the right hepatic vein. Subsequently the esophageal varices disappeared, and the patient remained asymptomatic for 11 years. In August 2009, endoscopy showed the recurrence of esophageal varices (grade 2). Doppler ultrasonography revealed complete occlusion of the TIPS tract and increasing ascites. The Child-Pugh score of this patient was 5 (Child A) at this time. We first attempted to access the shunt via the right internal jugular vein; however, catheter insertion into the proximal end of the shunt was impossible (Fig. 1A). To avoid a second TIPS procedure, recanalization of the occluded shunt via a transhepatic approach was considered. Under conventional fluoroscopy guidance, the stented TIPS tract was transhepatically punctured with an 18-cm-long 18G catheter needle (Cook, Bloomington, IL) via a right intercostal approach in the midaxillary line. Once direct TIPS tract puncture through the interspaces between the stent struts was successful, contrast medium was manually injected via the puncture needle to confirm proper needle position within the stent. Thereafter a 0.035-inch guide wire (Radiofocus; Terumo Europe, Leuven, Belgium) was inserted and successfully negotiated through the occlusion into the inferior vena cava followed by insertion of a 5F catheter (AC-1; Cook).
At this stage, a 10F sheath (Cook) was placed into the superior vena cava from the right internal jugular vein (Fig. 1B). A 30-mm snare (AndraMed, Reutlingen, Germany) was introduced via the jugular access to grasp the transhepatically placed guide wire in the right atrium (Fig. 1C) and to withdraw it through the transjugular sheath, leaving the distal end outside the patient. After reinforcement of the sheath by insertion of the inner coaxial 10F catheter, the sheath was advanced into the TIPS. (Fig. 1D). Once that sheath was lying safely within the proximal end of the stent, the catheter was exchanged for a second 0.035-inch hydrophilic guide wire (Radiofocus), which was then easily advanced into the main trunk of the portal vein. Then the pull-through guide wire was pulled back, leaving the tip of transhepatic catheter outside the TIPS tract. Injection of contrast medium showed intimal hyperplasia within the stent.
After sequential balloon dilatation of the entire TIPS tract with 6- and 8-mm balloon catheters (Fox Plus; Abbott Molecular, Des Plaines, IL), a 10 × 80-mm Viatorr stent graft (WL Gore, Flagstaff, AZ) was placed inside the bare metal stent, thereby extending the TIPS tract to the orifice of the right hepatic vein (Fig. 1E). Final pressure measurements showed gradients between the portal vein and vena cava of 24 mmHg with and 14 mmHg without balloon occlusion of the TIPS tract. Before the transhepatic catheter was withdrawn, a 3F catheter was inserted coaxially, and the puncture tract was embolized with a single 3-mm microcoil (Tornado; Cook) and 1 ml of a mixture of n-butyl-2-cyanoacrylate (Histoacryl; B Braum, Melsungen, Germany) and iodized oil (Lipiodol Ultra-Fluid; Guerbet, Roissy, France) at a 1:1 ratio. Polymerization within the catheter was avoided by filling it with glucose 50% before embolization. Four days later, the patient was discharged from the hospital without any complications. Doppler sonography 6 weeks after TIPS revision showed unimpaired patency of the TIPS tract and the disappearance of ascites.
Case 2
A 55-year-old man had undergone a TIPS procedure in August 2004 to treat alcoholic liver cirrhosis complicated by uncontrolled ascites and esophageal varices (Grade 2). An 8 × 70-mm Viatorr stent graft with a 50-mm PTFE-covered portion (WL Gore) had been placed in the TIPS tract. In 2007, complete TIPS tract obstruction was detected during routine ultrasound. Because the patient had recurrent esophageal varices (grade 2) but was otherwise asymptomatic, the patient was treated conservatively, and no interventional treatment was performed. In December 2009, he experienced severe abdominal distension due to ascites, and esophageal varices became more serious (grade 3). The Child-Pugh score of this patient was 7 (Child B) at this time. Consequently, it was decided to recanalize the TIPS.
At first, we attempted to access the shunt via the right internal jugular vein, which proved to be inaccessible via this approach (Fig. 2A). Thus, fluoroscopy-guided transhepatic puncture of the stent graft with a 30-cm-long 22G Chiba needle was tried, applying the same technique as described in patient 1. However, the cirrhotic liver was so rigid that the puncture needle could not be directed into to the stent graft lumen. Even though a fine needle was used, the patient bled from the puncture site, as demonstrated by computed tomography (CT). Bleeding subsided spontaneously without sequelae.
One week later, recanalization was attempted again. This time, the TIPS tract was punctured under CT–fluoroscopy guidance (Somatom Definition; Siemens, Erlangen, Germany) with a 19G coaxial needle (Sika-Med, Wiehl, Germany). An anterior access route was chosen to avoid passage of the ascites, which surrounded the right lobe of the liver (Fig. 2B). After the needle tip was placed in the stent graft lumen, a 0.035-inch hydrophilic guide wire (Radiofocus) was inserted and placed in the TIPS tract and deeply into the portal vein. The position of the guide wire was confirmed by use of a CT scout view. After fixation of the needle with sterile tape, the patient was transferred to the angiography suite and the following procedure was performed by using a similar technique as described in patient 1 (Fig. 2C). There were two difficulties. First, the membrane of the stent proved to be an obstacle for insertion the 5F catheter. Rotation of the catheter finally allowed advancement of the catheter into the TIPS tract. Second, because the tract had to be punctured far proximally, it was difficult to direct the catheter to the proximal end of the occluded stent. This was finally accomplished by the use of a 5F van Schie 4 catheter (Cook). The occlusion was overcome after probing with a straight 0.035-inch spiral guide wire and finally with the aid of a 0.035-inch hydrophilic guide wire (Radiofocus).
Contrast injection during the procedure proved that only the unstented section of the hepatic vein was occluded as a result of tissue overgrowth, whereas the segment stented with the stent graft was patent. There was no significant thrombus within the Viatorr endoprosthesis, nor any thrombi in the distal bare end. Therefore, the proximal part of the TIPS tract was dilated with a 4-cm-long, 8-mm balloon (Fox Plus; Abbott) and extended into the hepatic vein by using a 10 × 50-mm Viatorr stent graft (WL Gore) (Fig. 2D). The portocaval gradients with and without balloon occlusion of the TIPS tract were 29 and 18 mmHg, respectively. Final portography showed complete unimpaired patency of the TIPS. Before removal of the transhepatic catheter, the puncture tract was also embolized with n-butyl-2-cyanoacrylate/lipiodol as described above. The next day, the patient was discharged with improvement of the abdominal distension. Doppler sonography and endoscopy 6 weeks after TIPS revision confirmed patency in the TIPS tract and the disappearance of ascites and esophageal varices.
Literature Review
All English-language literature describing secondary interventional procedures for treating TIPS stenosis and occlusion were searched in Medline database, and all relevant references cited in the identified articles were reviewed. Twenty-one articles, published from 1992 to 2008, including two review articles, were found (Table 1). The most commonly applied technique for treating TIPS stenosis and occlusion is recanalization via the jugular vein approach with a hydrophilic guide wire. Alternative therapeutic strategies are as follows: (1) transjugular access via a Colapinto needle (Cook) for extra support [5, 6]; (2) transjugular direct stent puncture via a Rosch-Uchida needle (Cook) [5]; (3) transhepatic stent puncture [5, 7]; (4) creation of new parallel shunt [8–12]; (5) creation of new shunt by the so-called gun sight approach [13]; (6) creation of a new shunt via direct cavoportal puncture [14]. In large-sample-size studies, the success of TIPS recanalization was reported in 56 (89%) of 63 patients [11], 30 (91%) of 33 patients [10], and 16 (89%) of 18 patients [9]. Techniques for completion of TIPS tract recanalization include thrombolysis [15], mechanical thrombectomy [16], balloon dilatation, self-expandable bare metal stent [2, 5, 9–11], balloon-expandable stent [17, 18], and PTFE-covered stent graft [12, 19–24]. Recently, several articles showed that PTFE-covered stent grafts demonstrate excellent uninterrupted patency after TIPS revision.
Discussion
Shunt dysfunction after TIPS creation is a well-known complication, the result of thrombosis or intimal hyperplasia within the stent or at the nonstented portion of the hepatic vein [12]. The latter seemed to be the primary cause of obstruction in both of our patients. When bare metal stents were used, shunt dysfunction may occur in more than 50% of patients [2]. With currently available PTFE-covered stent grafts, the rate of hemodynamically significant in-stent stenosis or stent occlusion within the first year after treatment dropped to 11% and 6%, respectively [4]. The Wallstent (bare metal stent) in the first patient was patent for remarkably long time. Despite the improved shunt patency, with PTFE-covered stent grafts, shunt dysfunction remains a major issue in TIPS treatment.
In the case of TIPS dysfunction, shunt recanalization is preferred to the creation of a new TIPS tract. Recanalization is usually attempted via the transjugular, or less commonly via the transfemoral, venous approach. However, it is occasionally difficult to cross the occlusion with a purely endovascular approach because of the location of the stent and angulation in relation to the hepatic vein [5]. In 1994, Haskal and Cope first described a transhepatic approach for TIPS revision, in which a 22G needle advanced percutaneously through the liver into the lumen of the stent [7]. This technique is quick and simple to perform under conventional fluoroscopy; the stent provides a good radiopaque and tactile intrahepatic target. Therefore, in patient 1, a technique modified according to Haskal and Cope was successfully applied by means of conventional fluoroscopic guidance.
Fluoroscopically guided transhepatic puncture, however, may be both difficult and risky because of ascites and tissue induration due to liver cirrhosis. Ultrasound guidance may be helpful in principle, but CT is certainly the most accurate technique under these circumstances. CT was chosen for puncture because it provides excellent information on the spatial relationship between the target and its adjacent organs and vessels. In addition, CT-fluoroscopy helps to reduce the number of unsuccessful punctures because of its 3-D imaging at a high spatial resolution. A ventral access route was chosen to avoid passage of the ascites and because of the shorter distance from the cutaneous entry point to the stent graft. A 19G coaxial needle was used to minimize needle bending, as occurs in fine needles, for the initial unsuccessful puncture and to increase pushability. By combining these techniques, the needle was successfully placed into the stent graft lumen with a single puncture, even in this patient with severe cirrhotic liver and ascites.
As mentioned above, PTFE-covered stent grafts seem to be useful for ensuring long-term TIPS patency, although in patient 1, patency of the Wallstent was astonishingly long. Some reports directly compared the use of PTFE-covered stent grafts with bare metal stents and showed the advantage of stent graft in terms of shunt patency and clinical outcome [4, 25]. When attempting transhepatic TIPS revision in the presence of a stent graft, one has to consider whether a needle can penetrate the wall of the stent graft. Theoretically, a bare stent offers less resistance to a percutaneous puncture. To our knowledge, there are no previous reports in which transhepatic puncture of the TIPS stent graft was performed. With a rigid 19G needle, we successfully punctured through the PTFE-covered stent graft. Only the insertion of a 5F catheter met some resistance.
Bloss et al. reported the recanalization of TIPS, and portal and splenic venous occlusions via the direct transhepatic approach in one instance [26]. They concluded that the transhepatic approach was preferable in their case of chronic occlusion, as it was in patient 2. Moreover, this technique may also be useful for portal vein recanalization if inaccessible via the jugular vein.
In both of our patients, the transhepatic puncture tract was embolized with a mixture of n-butyl-2-cyanoacrylate and lipiodol to avoid bleeding after removal of the catheter. This is safer in patients with ascites and increased tendency to bleed. In patient 1, a microcoil was placed first to prevent migration of n-butyl-2-cyanoacrylate and lipiodol through the interspaces of the bare stent into the shunt. In patient 2, the use of a coil was omitted because of the presence of the stent graft.
Previous reports have indicated the risk of severe encephalopathy and acute liver failure after TIPS revision [5, 27]. In both of our cases, there were no sequelae during 6 weeks’ follow-up.
Review of the literature indicates that over the last decade, the reported number of TIPS recanalization procedures decreased. There is thus evidently a decreasing need for TIPS recanalization, presumably because of the use of PTFE-covered stent grafts. In addition, the lessons learned from the past tell us that the hepatic vein should be stented long enough to the entrance into the inferior vena cava to avoid tissue overgrowth of the proximal stent end.
In conclusion, TIPS revision via percutaneous transhepatic puncture in combination with a transjugular pull-through technique approach is feasible and useful, even in PTFE-covered stent grafts. If it is successful, it eliminates the need for creation of a second TIPS. CT-guided puncture can be particularly helpful in transhepatic puncture of the TIPS in complex situations, such as the presence of liver cirrhosis and ascites.
References
Haskal ZJ, Rees CR, Ring EJ et al (1997) Reporting standards for transjugular intrahepatic portosystemic shunts. J Vasc Interv Radiol 8:289–297
Haskal ZJ, Pentecost MJ, Soulen MC et al (1994) Transjugular intrahepatic portosystemic shunt stenosis and revision: early and midterm results. AJR Am J Roentgenol 163:439–444
Nishimine K, Saxon R, Kichikawa K et al (1995) Improved transjugular intrahepatic portosystemic shunt patency with PTFE-covered stent-grafts: experimental results in swine. Radiology 196:341–347
Charon JM, Alaeddin FH, Plimpalwar SA et al (2004) Results of a retrospective multicenter trial of the Viatorr expanded polyetrafluuoroethylene-covered stent-graft for transjugular intrahepatic portosystemic shunt creation. J Vasc Interv Radiol 15:1219–1230
Ferral H, Banks B, Wholey M et al (1998) Techniques for transjugular intrahepatic portosystemic shunt revision. AJR Am J Roentgenol 189:1041–1047
Gordon RL, LeBerge JM, Ring EJ et al (1993) Recanalization of occluded intrahepatic portosystemic shunts: use of the Colapinto needle. J Vasc Interv Radiol 4:441–443
Haskal ZJ, Cope C (1994) Combined transhepatic and transvenous approach to hepatic vein stenosis after transjugular intrahepatic portosystemic shunt (TIPS). Cardiovasc Interv Radiol 17:173–175
Haskal ZJ, Ring EJ, LaBerge JM et al (1992) Role of parallel transjugular intrahepatic portosystemic shunts in patients with persistent portal hypertension. Radiology 185:813–817
Hausegger KA, Sternthal HM, Klein GE et al (1994) Transjugular intrahepatic portosystemic shunt: angiographic follow-up and secondary interventions. Radiology 191:177–181
Sterling KM, Darcy MD (1997) Stenosis of transjugular intrahepatic portosystemic shunts: presentation and management. AJR Am J Roentgenol 168:239–244
Saxon RR, Ross PL, Mendel-Hartvig J et al (1998) Transjugular intrahepatic portosystemic shunt patency and the importance of stenosis location in the development of recurrent symptoms. Radiology 207:683–693
Cura M, Cura A, Suri R et al (2008) Cause of TIPS dysfunction. AJR Am J Roentgenol 191:1751–1757
Haskal ZJ, Duszak R Jr, Furth EE (1996) Transjugular intrahepatic transcaval portosystemic shunt: the gun-sight approach. J Vasc Interv Radiol 7:139–142
Seong CK, Kim YJ, Shin TB et al (2001) Transcaval TIPS in patients with failed revision of occluded previous TIPS. Korean J Radiol 2:204–209
Darcy MD, Vesely TM, Picus D et al (1992) Percutaneous revision of an acutely thrombosed transjugular intrahepatic portosystemic shunt. J Vasc Interv Radiol 3:77–82
Schmitz-Rode T, Vorwerk D, Marschall HU et al (1994) Portal vein thrombosis after occlusion of transjugular intrahepatic portosystemic shunt: recanalization with the impeller catheter. J Vasc Interv Radiol 5:467–471
Cope C, Baum RA, Haskal ZJ (1996) Balloon occlusion portography to diagnose new-onset left hepatic vein thrombosis and widening of an existing Wallstent TIPS by Palmaz stent for recurrent portal hypertension and variceal bleeding. Cardiovasc Interv Radiol 19:368–370
Kuhlman CG, Patel NH, Johnson MS et al (2002) Use of balloon-expandable stents in transjugular intrahepatic portosystemic shunts in cases of Wallstent endoprosthesis technical failure and revision of shunt senosis. J Vasc Interv Radiol 13:405–408
Saxon RR, Timmermans HA, Uchida BT et al (1997) Stent-grafts for revision of TIPS stenoses and occlusion: a clinical pilot study. J Vasc Interv Radiol 8:539–548
Haskal ZJ (1999) Improved patency of transjugular intrahepatic portosystemic shunts in humans: creation and revision with PTFE stent-grafts. Radiology 213:759–766
Sze DY, Vestring T, Liddell RP et al (1999) Recurrent TIPS failure associated with biliary fistulae: treatment with PTFE-covered stents. Cardiovasc Interv Radiol 22:298–304
Cejna M, Peck-Radosavljevic M, Thurnher S et al (2002) ePTFE-covered stent-grafts for revision of obstructed transjugular intrahepatic portosystemic shunt. Cardiovasc Interv Radiol 25:365–372
Haskal ZJ, Weintraub JL, Susman J (2002) Recurrent TIPS thrombosis after polyethylene stent-graft use and salvage with polytetrafluoroehylene stent-graft. J Vasc Interv Radiol 13:1255–1259
Rossi P, Salvatori FM, Fanelli F et al (2004) Polytetrafluoroethylene-covered nitinol stent-graft for transjugular intrahepatic portosystemic shunt creation: 3-year experience. Radiology 231:820–830
Jung HS, Kalva SP, Greenfield AJ et al (2009) TIPS: comparison of shunt patency and clinical outocomes between bare stents and expanded polytetrafluoroethylene stent-grafts. J Vasc Interv Radiol 20:180–185
Bloss MF, Lenz J Jr, Gemery J (2003) Combined transabdominal and transjugular recanalization of thrombosed TIPS, portal and proximal splenic veins. Cardiovasc Interv Radiol 26:189–191
Radeleff B, Sommer CM, Schawo S et al (2008) Acute liver failure after a late TIPS revision. Cardiovasc Interv Radiol 31:209–214
Conflict of Interest Statement
The authors declare that they have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tanaka, T., Günther, R.W., Isfort, P. et al. Pull-Through Technique for Recanalization of Occluded Portosystemic Shunts (TIPS): Technical Note and Review of the Literature. Cardiovasc Intervent Radiol 34, 406–412 (2011). https://doi.org/10.1007/s00270-010-9874-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00270-010-9874-2