Abstract
Early migration has reportedly been predictive for later implant failure. Using four different migration patterns, this study aimed to analyse migration behaviour of the two types of implant fixation—cemented and cementless—throughout the process of loosening. Migrational behaviour of 69 revised stems (49 cemented, 20 uncemented) was analysed retrospectively with EBRA-FCA (Einzel-Bild-Röntgen-Analyse, Femoral Component Analysis). Uncemented stems failed after early and late onset migration alike, while late migration was the predominant pattern in cemented stems. Mean prosthetic failure after early migration occurred 5.8 (±4.4) years postoperatively due to insufficient primary stability. Initially stable stems with late onset migration were revised after 12.4 (±4.5) years. Measurement of early migration was found to be a valuable tool to screen short-term and mid-term failure. In the long run the method’s sensitivity decreased. Late onset migration, however, preceded long-term failure by a mean of three years.
Résumé
Le but de cette étude est de rapporter les migrations précoces en rapport avec une prévision d’échec des implants. Pour cela, nous avons utilisé quatre groupes de PTH avec différentes migrations à propos du devenir de deux types de fixation des implants, cimentés ou non cimentés. l’évolution de la migration sur 69 prothèses (pièces fémorales 49 cimentées, 20 non cimentées) ont été analysées de façon rétrospective selon la méthode EBRA-FCA les pièces fémorales non cimentées peuvent présenter des échecs précoces et tardifs, alors que les prothèses cimentées ne présentent que des échecs tardifs. L’échec le plus fréquent est la migration qui se fait en moyenne à 5,8 (±4,4) ans post-opératoire en relation avec une insuffisance de stabilité primaire. Les pièces fémorales stables ont une migration beaucoup plus tardive et ne sont révisées qu’après 12,4 ans (±4,5). la mesure de la migration précoce permet de dépister les échecs à court et moyen terme. La méthode décrite est fiable, les migrations tardives cependant sont précédées d’un échec à long terme et ont évolué pendant au moins trois ans avant la reprise.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Early migration has been shown to be predictive for late aseptic failure in numerous studies [4, 7–10, 13, 16, 17]. Previous publications primarily aimed to identify threshold values of early migration for prediction of later aseptic failure. Freeman and Plante-Bordeneuve [4] recognised a migration threshold of 1.2 mm per year during the first two years. Walker et al. [17] found a rate of failure of 95% for stems with a subsidence of more than 2.6 mm two years postoperatively. Kärrholm et al. [7] used RSA (radiostereometric analysis) [14] and calculated a risk of 50% if the implant had subsided more than 1.2 mm within the first two years. The risk increased to 95% if a threshold of 2.4 mm was exceeded. Krismer et al. [10] used EBRA-FCA (Einzel-Bild-Roentgen-Analyse, Femoral Component Analysis) [2] for migration analysis. The authors identified a threshold value of 1.5 mm after two years as a predictive factor for aseptic failure. Implants without migration, on the other hand, showed good long-term performance. These results were confirmed by other authors [3, 6, 12]. More importantly, Krismer and associates identified four types of migration patterns: early onset of migration with continuous subsidence, secondary stabilisation after early migration, late onset of migration after an initial stable period, and stability throughout the whole process of observation [10]. These patterns, however, were mainly derived from a large number of clinically stable stems. Due to lack of a greater quantity of failed stems, information about migrational behaviour throughout aseptic implant failure was poor.
The purpose of this study was to identify the modalities of subsidence in failing femoral components. Special attention was given to the influence of stem fixation (cemented versus cementless) on the overall migration pattern.
Material and methods
Patients
All patients undergoing primary total hip arthroplasty and consecutive revision surgery for aseptic loosening were included in the study. Between January 1996 and December 2004, 124 femoral components were revised and confirmed to be loose at the time of surgery. Implant infection was ruled out by bacteriological analysis in all cases. Retrospective migration measurement was obtained by using routine follow-up radiographs preceding revision surgery. As EBRA-FCA [2] was applied, radiographs which technically were not comparable were eliminated by the method’s comparability algorithms. A minimum of four radiographs per series were needed to obtain representative results. Fifty-five patients had less than four comparable X-rays between primary implantation and revision, leaving 69 cases of 20 uncemented and 49 cemented stems for migrational analysis. All primary implantations had been performed by nine independent experienced surgeons via a standardised lateral transgluteal approach in supine position [1]. Implant types are listed in Table 1.
When comparing the two groups (cemented versus cementless) no significant differences were found in terms of patient gender or implant side (t-test: p = 0.85 and p = 0.29 respectively). Patients with cemented implants were significantly older than those with a cementless implant, at the time of the primary intervention (60.2 years ± 8.7 versus 55.4 ± 6.9 years; t-test: p < 0.05) as well as at the time of revision surgery (70.9 ± 8.2 versus 64.1 years ± 7.1, p < 0.01). The two groups were comparable in terms of time to revision (cementless 8.7 years ± 5.4; cemented 10.7 years ± 4.9; p = 0.09), showing a tendency towards earlier failure in cementless stems.
Migration measurement
Implant migration was measured in conventional anterior–posterior radiographs of the hip. Analogous images were digitised with a VXR-8 Film Digitizer (Vidar Systems Corporation, Herndon, Virginia, USA). Digitally archivated radiographs were accessed with the IcoView 1.7.4.26 program (IcoServe Information Technologies, Innsbruck, Austria). EBRA-FCA (2003/SP2) was the method of choice for migration measurement in this retrospective study; it reaches a specificity of 100% and a sensitivity of 78% for detection of migration of one or more millimetres. The systemic error of the method is ±1.5 mm, Cronbach’s coefficient α for interobserver variance is reportedly 0.84 [2], and the method was shown to have sufficient precision to detect clinically relevant migration [18].
Migration behaviour was classified according to the four patterns (A–D) described by Krismer et al. [10]. Pattern A was defined by early onset migration with continuous subsidence, while pattern B represents a secondary stabilisation after two years. Pattern C was defined by late onset migration two or more years after implantation. Pattern D implied no detectable migration at all. Early migration was described as detectable migration within the first two postoperative years by Freeman and Plante-Bordeneuve [4]. Detectable migration was considered as migration of 1.5 mm or more according to the accuracy of the method.
Radiographic material consisted of a total of 584 X-rays in 69 series. Radiographs were taken three, six, and twelve months after implantation and at consecutive annual checkups. The series contained a mean of 8.5 radiographs (±3.7) without significant difference between uncemented and cemented implants (t-test p = 0.4). Comparability limits of EBRA-FCA were set at 3 mm. For this reason a total of 23 radiographs (3.8%) were excluded from calculations.
The sensitivity of the method is defined as: sensitivity=true positive/(true positive+false negative), employing migration patterns introduced by Krismer et al. [10] (see Table 2). Sensitivity was calculated for every year of the entire observation period. Specificity had already been identified at 80% by Krismer et al. [10] and was not re-evaluated here, as false positive and true negative groups (stable stems) were not subjects of this study.
Statistics
Statistical analysis was performed with the SPSS 11.0 statistical software package (SPSS Inc., Chicago, Illinois, USA). Gaussian distribution was tested with the Kolmogorov Smirnov test. Quantitative variables are described by mean and standard deviation (mean ± SD) in cases of normal distribution, otherwise with median and interquartiles; mean values of the subgroups were compared with Student’s t-test or Mann-Whitney test, respectively. A 0.05 level of significance was used for all analyses.
Results
For cementless stems, the dominating pattern of implant loosening was early onset of migration (type A, 11/20 or 55%; see Table 3); whereas the cemented stems tended towards a late onset migration pattern (type C, 30/49 or 61%). The share of prostheses with failure after early onset migration was far smaller in this group. For the remaining cemented implants, EBRA-FCA detected no migration throughout the entire process of loosening (pattern D). In these cases, implant failure was not a consequence of subsidence but of other factors (see Table 4). Despite the difference in mean onset of migration (t-test p < 0.01), cementless and cemented stems were comparable in terms of stem survival (p = 0.07) and total amount of migration (p = 0.12).
Stems with early migration (pattern A) showed analogous migrational behaviour in cemented and uncemented implants (onset of migration, p = 0.67; total migration, p = 0.78; stem survival, p = 0.23), as well as stems with late onset migration (pattern C; migration onset, p = 0.09; total migration, p = 0.51; and stem survival, p = 0.63).
If, however, implants with early migration onset (pattern A) were compared with late migrating implants (pattern C), differences became evident regardless of type of fixation. An implant with early onset of migration was revised before an implant with late migration onset had even started to subside (migration onset, p < 0.01). Stems with migration pattern A were revised at a mean of 6.6 (±3.8) years earlier than stems with migration pattern C (stem survival, p < 0.01). Late onset subsidence preceded revision surgery at a mean of 3.4 (±0.3) years (cementless 5.4 ± 1.5 years; cemented 2.8 ± 0.2 years).
In a second analysis, sensitivity of migration measurement was calculated for every year of the entire observation period. All implants, which had been revised during the first three years, had undergone early migration. Sensitivity was 100% throughout this follow-up period, but decreased subsequently (see Fig. 1). Uncemented implants showed a higher percentage of early migrators. Consequently, migration measurement was more sensitive for cementless stems. For these stems, sensitivity of the method was 100% through seven postoperative years and was still 90% by the 12th year. Due to the higher share of late migrating stems in cemented implants, sensitivity decreased much faster in this group.
Discussion
Migration measurements as a method of evaluating implant performance have been shown to correlate with the incidence of late aseptic failure [8, 11, 13]. However, the main weakness of these studies was their relative short-term follow-up, rarely covering the first postoperative decade [4, 7, 10, 15, 17], whereas the majority of the stems in our study (39/69 or 56.5%) demonstrated late onset migration with a mean survival of 12.4 years. Migration of these implants did not occur before implants with early migration had already been revised for aseptic failure. By following a collective of failed stems throughout the entire time span from implantation to revision surgery, this study was able to observe the patterns of migration. Our results confirmed previously published threshold values for prediction of aseptic loosening [4, 7, 10, 11, 17] with one important exception. They were only valid for implants which had undergone short-term to mid-term failure. Implants with prolonged survival had rarely shown early migration. These findings are in contrast to Mjöberg’s postulation [11] that late migration does not exist and was only late detection of early migration. He saw migration as a result of lacking primary osteointegration and attributed it to thermal necrosis during intraoperative polymerisation of bone cement. Our study outlines the existence of late onset of migration, independent from stems with early migration, occurring with both cementless and cemented fixation techniques. These findings have important implications in the understanding of the durability of implant fixation. More specifically, late onset migration probably represents a fatigue failure of the bone–implant interface in cementless stems, fatigue failure at the cement–bone interface, or cement cracking in cemented stems. Early migration, on the other hand, can be interpreted as a consequence of primary instability due to poor technique or implant design.
Due to its high sensitivity throughout the first postoperative years, the measurement of early migration is a reliable screening method for short-term and mid-term implant failure. Late fatigue failure cannot be predicted by measuring early migration. Late migration onset during long-term follow-ups, however, preceded implant revision by three years.
References
Bauer R, Kerschbaumer F, Poisel S, Oberthaler W (1979) The transgluteal approach to the hip joint. Arch Orthop Trauma Surg 95:47–49
Biedermann R, Krismer M, Stöckl B, Mayrhofer P, Ornstein E, Franzén H (1999) Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement Einzel-Bild-Roentgen-Analyse Femoral-Component-Analysis. J Bone Joint Surg [Br] 81:266–272
Eingartner C, Heigele T, Dieter J, Winter E, Weise K (2003) Long-term results with the BiContact system - aspects to investigate and learn from. Int Orthop 27:11–15
Freeman MAR, Plante-Bordeneuve P (1994) Early migration and late aseptic failure of proximal femoral prostheses. J Bone Joint Surg [Br] 76:432–438
Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components. A radiographic analysis of loosening. Clin Orthop 141:17–27
Hamadouche M, Witvoet J, Porcher R, Meunier A, Sedel L, Nizard I (2001) Hydroxyapatite-coated versus grit-blasted femoral stems. A prospective, randomised study using EBRA-FCA. J Bone Joint Surg [Br] 83:979–987
Kärrholm J, Borssén B, Löwenhielm G, Snorrason F (1994) Does early micromotion of femoral stem prostheses matter? 4–7 year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg [Br] 76:912–917
Kärrholm J, Snorrason F (1993) Subsidence, tip, and hump micromovements of noncoated ribbed femoral prostheses. Clin Orthop 287:50–60
Kobayashi A, Donnelly WJ, Scott G, Freeman MAR (1997) Early radiological observations may predict the long-term survival of femoral hip prostheses. J Bone Joint Surg [Br] 79:583–589
Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C (1999) The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-Femoral Component Analysis. J Bone Joint Surg [Br] 81:273–280
Mjöberg B (1991) Fixation and loosening of hip prosthesis: a review. Acta Orthop Scand 62:500–508
Meek RM, Michos J, Grigoris P, Hamblen DL (2002) Mid-term results and migration behaviour of a ti-alloy cement stem. Int Orthop 26:356–360
Nistor L, Blaha JD, Kjellström U, Selvik G (1991) In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis. Clin Orthop 269:220–227
Selvik G (1989) Roentgen stereophotogrammetry: a method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl 232:1–51
Søballe K, Toksvig-Larsen S, Gelineck J, Fruensgaard S, Hansen ES, Ryd L, Lucht U, Bünger C (1993) Migration of hydroxyapatite coated femoral prostheses: a roentgen stereophotogrammetric study. J Bone Joint Surg [Br] 75:681–687
Stoeckl B, Brabec E, Wanner S, Krismer M, Biedermann R (2005) Radiographic evaluation of the Duraloc cup after 4 years. Int Orthop 29:14–17
Walker PS, Mai SF, Cobb AG, Bentley G, Hua J (1995) Prediction of clinical outcome of THR from migration measurements on standard radiographs: a study of cemented Charnley and Stanmore femoral stems. J Bone Joint Surg [Br] 77:705–714
Wilkinson JM, Hammer AJ, Elson RA, Stockley I, Eastell R (2002) Precision of EBRA-digital software for monitoring implant migration after total hip arthroplasty. J Arthroplasty 17:910–916
Acknowledgment
All authors certify that they have no commercial associations (e.g. consultancies, stock ownership, equity interest, patient/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article. No funds have been received or will be received in connection with the submitted article. No professional or financial affiliations have been perceived or will be perceived to have biased the presentation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kroell, A., Beaulé, P., Krismer, M. et al. Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation. International Orthopaedics (SICOT) 33, 1501–1505 (2009). https://doi.org/10.1007/s00264-008-0701-1
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00264-008-0701-1