Abstract
Here, we establish a CT-radiomics based method for application in invasive, orthotopic rodent brain tumour models. Twenty four NOD/SCID mice were implanted with U87R-Luc2 GBM cells and longitudinally imaged via contrast enhanced (CE-CT) imaging. Pyradiomics was employed to extract CT-radiomic features from the tumour-implanted hemisphere and non-tumour-implanted hemisphere of acquired CT-scans. Inter-correlated features were removed (Spearman correlation > 0.85) and remaining features underwent predictive analysis (recursive feature elimination or Boruta algorithm). An area under the curve of the receiver operating characteristic curve was implemented to evaluate radiomic features for their capacity to predict defined outcomes. Firstly, we identified a subset of radiomic features which distinguish the tumour-implanted hemisphere and non- tumour-implanted hemisphere (i.e, tumour presence from normal tissue). Secondly, we successfully translate preclinical CT-radiomic pipelines to GBM patient CT scans (n = 10), identifying similar trends in tumour-specific feature intensities (E.g. ‘glszm Zone Entropy’), thereby suggesting a mouse-to-human species conservation (a conservation of radiomic features across species). Thirdly, comparison of features across timepoints identify features which support preclinical tumour detection earlier than is possible by visual assessment of CT scans. This work establishes robust, preclinical CT-radiomic pipelines and describes the application of CE-CT for in-depth orthotopic brain tumour monitoring. Overall we provide evidence for the role of pre-clinical ‘discovery’ radiomics in the neuro-oncology space.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Introduction
Glioblastoma (GBM) is an invasive, heterogeneous, and incurable malignancy1,2 with patients demonstrating a low median life expectancy (< 2 years). Radiological imaging is an integral aspect of disease management. Indeed, non-invasive monitoring methods are essential in the neuro-oncology setting, due to the intrinsic difficulties associated with intracranial biopsy3. In this context, Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) underpin diagnosis4, longitudinal disease management, and monitoring of therapeutic response5. Nevertheless, while MRI is considered the ‘standard of care’ imaging modality in the clinic, the diagnostic value of CT imaging remains pertinent6,7. Specifically, patients with suspected intracranial malignancies undergo CT at first diagnosis, during radiotherapy treatment planning, and when MRI is precluded (e.g. due to the presence of pacemaker, or older aneurysm clips)6.Response Assessment in Neuro-Oncology (RANO) criteria which are implemented in the assessment of patient CT and MRI scans8,9 facilitate meaningful disease surveillance, evaluation of radiographic response and progression9, and represent the gold standard for first-line treatment response evaluation in GBM.
Radiomic analysis of medical images is a disruptive methodology which allows the extraction of quantitative features from radiological scans. Overall, radiomics has emerged as a powerful method to gain clinically relevant insights into tumour biology, patient prognosis and treatment prediction. In the context of brain tumours, radiomic feature analysis may enhance the use of the RANO criteria (as highlighted by the emergence of the ‘Artificial Intelligence and Imaging Response (AI-RANO) Criteria’10). Moreover, radiomics11,12 has been shown to support clinical assessment of glioma staging13,14, characterisation of GBM tumour heterogeneity15 and may reveal critical information underpinning tumour phenotype16,17, response and progression. Most recently, radiomic analysis which has largely focused on MR-based radiomic feature assessment, has been ‘reverse translated’ to pre-clinical scan data18.
In the present study we sought to establish a CT-radiomics pipeline for application in the monitoring of pre-clinical GBM models. Specifically, we demonstrate the utility of pre-clinical CT-radiomics to distinguish image features and characteristics which are not visible by eye. Importantly, we show that CT-radiomic features facilitate differentiation of the tumour implanted hemisphere when compared to the non-tumour implanted hemisphere on CE-CT scans. Additionally, we show that, rodent-derived CT-features interrogated in a clinical dataset manifest analogous trends in feature distribution (i.e. similarly increased intensity), suggesting a mouse-to-human species conservation (a conservation of radiomic features across species18). Moreover, our hypothesis generating study indicates that radiomic features may assist in the identification of tumours by CE-CT earlier than is possible by visual assessment of pre-clinical CT images (Fig. 1).
Results
CT-radiomic workflow for analysis of orthotopic GBM tumours
To begin, we performed longitudinal CE-CT imaging of U87R-Luc2 orthotopic tumour bearing NOD/SCID mice (n = 10, Fig. S1a) (Figs. 2a, S1c). Tumour-bearing mice underwent CE-CT imaging (Figs. 2d, S1c) at three-weekly intervals. Mice were monitored until reaching humane endpoint (Fig. S1a). Upon visual inspection (blinded/randomized), 16% of CE-CT images were identified as positive for tumour presence (Fig. S1d). Throughout, tumour growth was monitored via weekly BLI (Fig. 2b) and tumour presence was confirmed post mortem via immunohistochemistry (IHC). IHC analysis further confirmed a consistent phenotype across all animals with no significant difference in proliferation (Ki67) or vessel density (CD31). (Fig. S1b). In all, tumours were detectable using BLI one week (Week-1) following tumour implantation (Fig. 2c). In contrast, tumours were only detectable upon visual inspection in 16% of CE-CT images overall, with none detectable by eye before week 6 (Fig. S1d). As expected, these data confirm that BLI is a more sensitive method for pre-clinical intracranial tumour detection than CE-CT imaging19,20,21,22. Interestingly, mouse 9 (M9) displays both a strong BLI signal at day 75 (Fig. 2c) and an extended survival time compared to other animals (76 days vs 50.5 days median survival; Supplementary Figure S1a). Indeed, visual inspection of M9 at the time of euthanasia highlighted the presence of a tumour located in close proximity to the skull, thus underpinning this antipodal relationship between BLI signal and survival time (Fig. 2c; anecdotal observation).
Next, preclinical GBM radiomic feature extraction pipelines were established (Figs. 1, 3). Delineation of reconstructed CE-CT images in DICOM format was performed using PMOD software (version 3.9; PMOD Technologies). A threshold was determined per image to exclude bone from generated bounding boxes (Fig. 3a). 3D Volume of interests (VOIs) were delineated for both the right hemisphere (RH; tumour-implanted hemisphere, whole hemisphere delineated) and left hemisphere (LH; non-tumour-implanted hemisphere, whole hemisphere delineated) of each animal. ROI binary masks were generated and stored in a 3D volume NIfTI format. Feature extraction via PyRadiomics successfully extracted a total of 833 features for both LH and RH (Fig. 3b) including: shape (n = 14), first order statistics (n = 18), gray level cooccurrence matrix (GLCM) (n = 22), gray level run length matrix (GLRLM) (n = 16), gray level size zone matrix (GLSZM) (n = 16), gray level dependence matrix (GLDM) (n = 14) and neighbouring gray tone difference matrix (NGTDM) (n = 5). Wavelet filtering was subsequently applied to these features. Shape features were excluded from all analyses (Fig. S2). Definitions for radiomics features are available online within the Pyradiomics documentation (https://pyradiomics.readthedocs.io/en/latest/features.html). Notably, while inclusion of wavelet filtering of images increases data dimensionality, recent studies have demonstrated that inclusion of wavelet features increases the reproducibility and repeatability of radiomic signatures23.
Selection of CT radiomic features which discriminate tumour vs normal tissue
We first confirmed that novel preclinical GBM CT-radiomic pipelines facilitate discrimination of tumour presence within the tumour-implanted hemisphere of the brain (RH). To this end we examined whether CT-radiomic features may assist in distinguishing between non-tumour-implanted (LH) and tumour-implanted (RH) rodent brain regions across each timepoint. Specifically, we assessed inter-hemisphere (LH vs RH) features at week-3, week-6 and week-9/12 (Fig. 4a). Comparison of LH and RH features via recursive feature analysis (RFE) (Fig. S3a–c), identified a panel of wavelet filtered first order, ngtdm, glcm, glszm and glrlm features which effectively differentiate between LH and RH (Fig. 4a, Fig. S3d–f). In all (Fig. 4a), significantly altered features (n = 2–5) were identified and performance in validation set generated an AUC > 0.7. By way of summary, Fig. 4b tabulates features identified as the best feature subset following RFE analysis. Taken together, CT-radiomic features may therefore assist in distinguishing between the tumour-implanted hemisphere and non-tumour-implanted hemisphere in orthotopic rodent GBM models. Furthermore, these tumour-region specific features may facilitate confirmation of tumour growth when BLI is unavailable.
Performance of preclinical CT-radiomics features in patient datasets: proof of concept
To ascertain preclinical-clinical feature relevance and investigate mouse-to-human species conservation, pre-clinical, tumour-specific features were assessed in an exploratory, publicly available patient CE-CT cohort (n = 10) downloaded from ‘The Cancer imaging archive’ (TCIA) (Fig. 4c,d, S7). This cross-sectional cohort comprises a 1:2.3 ratio of female to male patients. Moreover 60% of patients were > 60 years of age upon diagnosis, with 30% of patients surviving > 1 year post diagnosis. IDH/MGMT status was unavailable for this cohort (supplementary Fig. S7). Features identified as significantly altered (n = 11 features) in the inter-hemisphere (LH/non-tumour-implanted hemisphere vs RH/tumour-implanted hemisphere) analyses were univariately analysed between normal and tumour regions of clinical GBM CT images. As summarised in Fig. S4, several features show altered distributions in tumour regions, with wavelet HLL first order maximum (p = 0.00833) significantly altered between normal and tumour regions. Moreover, wavelet LHL glszm zone entropy displayed increased intensity (p = 0.08768) in tumour regions (Fig. 4d). Markedly, analogous trends towards increased intensity in tumour vs normal clinical CT regions of these features tentatively suggests feature conservation across species.
Evaluation of CT radiomic features for early tumour detection
We lastly sought to determine if CT-radiomic features could support tumour detection as early as experimental BLI (Week-1) or prior to tumour detection by visual assessment of CT images. To achieve this, we applied both conventional (Fig. 5) and delta radiomics (Fig. 6) approaches. Specifically we assessed radiomic features in our initial CT scan at week-3, where tumours were not visually detectable and compared to week-6 and week-9/12. A five-feature classifier was identified upon comparison of the tumour-implanted hemisphere (RH) early timepoint features at week-3 and week-6 (Performance in validation set; AUC: 0.86, 95% CI 0.53–1), which may be capable of distinguishing between early RH timepoints (Fig. S5a). Furthermore, comparison of mid (Week-6) and late (Week-9/12) features within the tumour-implanted hemisphere (RH) identifies a five-feature classifier (including both original and wavelet filtered features) with a performance in validation set of AUC: 0.81 (95% CI 0.43–1; Fig. 5b, S5c). In contrast, analysis of week-3 and week-9/12 features within the tumour region (RH) did not generate an effective classifier for differentiation between mid- and late timepoints (Performance in validation set; AUC: 0.38, 95% CI NA-NA). Here the ROC curve indicates inverted performance (Fig. S5b). By way of summary, Fig. 5b tabulates features identified as the best feature subset following RFE analysis (Fig. S5d–f). Taken together, these data demonstrate that radiomic features from the CE-CT scans may assist in earlier discrimination of the tumour-implanted hemisphere. Moreover, CT-radiomic features can identify the tumour-implanted hemisphere 3–6 weeks before tumours are detectable on visual inspection of images. (NB: longitudinal radiomic features were not verified in clinical datasets due to the absence of a longitudinal clinical imaging dataset).
Evaluation of CT delta radiomic features for early tumour detection
We next evaluated whether analysis of net feature change between normal tissue (LH) and tumour region (RH) could improve the ability of CT-radiomic features to determine tumour presence. Here, the Boruta algorithm, where features compete with shadow attributes rather than among themselves, was applied (Fig. S6). Firstly, comparison of week-3 and week-9/12 delta radiomic features (DRFs) identified two features significantly altered between timepoints as ‘confirmed important’ (Z-score of feature > Maximum Z-score among shadow attributes). This analysis identified original glcm Joint Entropy as significantly increased (p = 0.001954) and original gldm small dependence high gray level emphasis as significantly decreased (p = 0.03301) in week-9/12 compared to week-3 (Fig S6a,b). Comparison of week-3 and week-6 DRFs, and week-6 and week-9/12 DRFs, rejected all other features as potential classifiers (Figs. 6, S6a). Figure 6 illustrates DRFs identified following timepoint comparison. Overall, these data indicate that normalisation to the corresponding hemisphere in which there is no tumour presence, and therefore delta radiomics, may indeed improve the utility of CT-radiomic features for early tumour detection in certain contexts. As above, features now require verification in longitudinal, clinical patient datasets.
Discussion
In the current study we have established preclinical CT-radiomic workflows and have shown that CT-radiomic features have the potential to distinguish the tumour-implanted hemisphere from the non-tumour-implanted hemisphere, thereby supporting early detection of tumours during longitudinal analysis. Moreover in a proof of concept study we have successfully translated preclinical radiomic pipelines to patient datasets. In this context, pre-clinical CT-features interrogated in clinical datasets demonstrated analogous trends in intensities (i.e. similarly increased intensity in regions of tumour tissue), suggesting species conservation30.
Firstly, we employed the invasive24, orthotopic U87R-Luc2 GBM model (xenograft) to optimise preclinical brain tumour radiomic pipelines and identify radiomic features which may indicate tumour presence. Initially, CE-CT images were visually assessed, with only 16% of tumours visually discernible on average (Fig. S1d). We next interrogated CE-CT images to optimise radiomic feature analysis and assess if radiomic features could assist in discrimination of the tumour-implanted hemisphere compared to the non- tumour-implanted hemisphere. Strict reduction of redundant features (removal of shape and highly inter-correlated features) and implementation of robust statistical methods were employed throughout this study. Moreover, open-source software and tools were implemented to ensure reproducibility of the preclinical pipeline. When radiomic features in tumour and normal tissue were compared, we identified a three-feature classifier which putatively discriminates between the non-tumour-implanted hemisphere (LH) and tumour-implanted hemisphere (RH) regions. Aligning with previous studies, here LLH firstorder total energy wavelet feature was identified. Total Energy is the value of Energy feature, scaled by the voxel volume (cubic mm)25, and has previously been identified as significantly altered between Grade II and III gliomas (MRI)26. Similarly, GLCM cluster shade (measure of skewness and uniformity) which is significantly increased (representing greater asymmetry about the mean) in tumour regions in our analyses has been utilised in the discrimination of high grade and lower grade primary brain tumours27. Therefore, these features may collectively facilitate discrimination of tumour-implanted and non-tumour implanted hemispheres. Further validation in larger cohorts is now required.
Next, features identified in preclinical CE-CTs were assessed in an exploratory, clinical TCGA-TCIA cohort of newly diagnosed GBMs28. As no robust longitudinal clinical datasets were available for analysis, radiomic features identified as discriminators of normal vs tumour tissue, were univariately assessed for alterations between normal and tumour regions. Analogous trends in First Order Maximum (indicative of the maximum gray level) and Zone Entropy feature intensity (a higher zone entropy value indicates more texture heterogeneity) across animal and patient CTs were identified, suggesting species conservation. Moreover, entropy has been previously shown to correlate with glioma grade27, further indicating features identified in the preclinic may indeed translate to the clinic.
Lastly, our results indicate that CT-radiomic features could support earlier detection of tumour presence when features were compared between timepoints (early RH (tumour-implanted hemisphere)-timepoint (Week-3 vs Week-6) comparison, and RH-mid (Week-6) and RH-late (Week-9/12)). Here we identified a number of wavelet gray level emphasis features (a higher value indicates a greater concentration of high gray-level values present) which have been shown to have prognostic utility when considered alongside GBM clinical predictors29. Moreover, identified among these features, NGTDM Coarseness (A measure of average difference between the center voxel and its neighbourhood—higher values indicates a more uniform texture) has been shown to be significantly altered in the early thermographic detection of breast cancer30. Overall, these data suggest that comparison of pre-clinical CT-radiomic features across timepoints represents a viable strategy for identification of imaging biomarkers for early brain tumour detection. Indeed, interrogation and verification of these features in longitudinal datasets which incorporate clinical characteristics such as IDH mutation and MGMT methylation status, patient age and overall survival as additional variables is now warranted. Notably, raw radiomic features values vary in intensity between datasets due to inter-scanner differences and key differences between clinical and pre-clinical scanners (E.g. scan energies, voxel size etc.). Therefore future expanded preclinical-clinical studies, which multivariately assess CT-radiomic features, will require harmonisation of data (E.g. via the ComBAT method).
To refine and further exploit the availability of longitudinal data, relative net change in preclinical GBM CT-radiomic features was also studied31. It has previously been shown that Delta radiomic features (DRF; ∆) may generate an improved performance compared to standard radiomics signatures32. DRF analysis was therefore implemented to interrogate DRF ability to facilitate early tumour prediction. Interrogation of net relative differences between LH and RH identified a number of features of importance. Among the features identified by the Boruta algorithm, GLCM Joint entropy (randomness/variability in neighbourhood intensity values) has previously been identified as indicative of oesophageal tumour stage33. Overall, the identification of these features indicates that CT-features representative of heterogeneity may be a suitable marker for tumour presence in preclinical orthotopic GBM CE-CTs.
While small animal CT imaging is not without challenges, including diffuse tissue margins and relatively poor soft tissue contrast34,35, we have established a clinically relevant CT-radiomics pipeline for application in rodent brain tumour models. Notably, while the RANO criteria have not yet been translated to the preclinical setting, the clinical Response Evaluation Criteria in Solid Tumours (RECIST) criteria23 has been adapted for use in PDX clinical trials (mRECIST)24,25, indicating the strong value in the preclinical translation of clinical workflows, and ultimately improving translatability of preclinical models. Indeed, application of both conventional and delta CT-radiomics may enhance the utility of CT when applied to rodent brain tumour models, which may thus represent a clinically relevant and viable alternative to invasive biological sampling. Importantly, randomisation of outcomes throughout these analyses resulted in undefined AUC’s and CIs, indicating that despite relatively low cohort animal numbers in certain cases, the established feature analysis pipeline produced rational predictions.
Overall, limitations of this study include relative low sample numbers in both preclinical (experimental group numbers limited due to study design and adherence to the 3Rs) and clinical cohorts (lack of availability of public, longitudinal GBM CE-CT datasets). Future studies will require test–retest analyses to ensure robustness and reliability of features over time. In addition, studies which implement an expanded panel of GBM models, directly comparing tumour size (via harvested tissue and IHC), tumour infiltration pattern (to account for tumour growth within the needle tract) and radiomic features, are warranted. Moreover, these studies would benefit from comparative, quantitative MRI to assist in overcoming discrepancies arising in the estimation of tumour burden and tumour progression when BLI is used alone, and when tumours are located close to the skull36,37. These studies will underpin the future application of specific, tumour-region CT-radiomic features in earlier tumour detection. Therefore, to build on this hypothesis generating work, additional studies are now warranted. These studies should implement more frequent, longitudinal CT imaging, more adequately powered preclinical imaging groups and comparative MR imaging. Likewise, studies of radiomic features in a panel of GBM PDXs could yield classifiers which are progressively more clinically translatable compared to xenograft GBM models38. Finally, development of deep learning methods to remove labour intensive and oftentimes subjective tumour segmentation is required.
In conclusion, this study demonstrates a promising role for pre-clinical CT-radiomic pipelines. Our data supports the application of a pre-clinical CT-radiomics strategy as an alternative monitoring method for rodent brain tumour models when BL and MR imaging is unavailable. Notably, we illustrate that identified radiomic features have capacity for translation to clinical images, indicating that preclinical models may provide discovery platform for clinically relevant radiomic features. Overall, we demonstrate the potential for preclinical CT-radiomic classifiers to support the detection of orthotopic brain tumours which are otherwise difficult to detect visually.
Methods
Cell culture
The invasive24,39 human GBM cell line U87R-Luc2 (gift from Peter Forsyth, Moffitt Cancer Center, Tampa, FL) was cultured in Dulbecco’s Modified Eagle’s Medium (DMEM) F12 supplemented with 10% fetal bovine serum and 400 mg/mL G41822.
GBM orthoxenograft studies
In vivo studies were licensed and approved by the Heath Products Regulatory Authority (License number AE18982/P123) and University College Dublin’s Animal Research Ethics Committee (Protocol number P17-21). Animal experiments were carried out under Directive 2010/63/EU of the European Parliament on protection of animals used for scientific purposes. All sections of this manuscript adhere to ARRIVE Guidelines.
In vivo studies, which adhere to the PREPARE guidelines, were performed at the University College Dublin specific pathogen free (SPF) facility. Mice imported from Charles River UK (Cambridge, UK) were housed in groups of 4–6 in individually ventilated cages (Techniplast, London, UK) and given access to food and water ad libitum. A 12 h light/12 h dark cycle, 40–50% humidity and temperature of 18–22 °C were maintained throughout. Environmental enrichment of red polycarbonate houses, pura wooden chew stick, nesting material and clear plastic tunnels were provided. Animals were visually assessed daily to monitor overall health status. Experimental animal cohort numbers were calculated based on Workman et al.40.
For tumour implantations, NOD/SCID (4–6 weeks; female; 18–22 g) were anesthetized with O2/isoflurane mixture (1.5% isoflurane in 100% O2) and fixed in a stereotaxic frame. 2 × 105 of U87R-Luc2 cells (NOD/SCID [n = 20]) were orthotopically implanted at a depth of 2 mm into the right hemisphere (RH) as previously described22. Adverse effects were scored on a multi-category scale and a rodent coma scale monitored neurological status.
In vivo data were analysed using GraphPad Prism (GraphPad Software, San Diego, CA USA) or Excel (Microsoft, Redmond, WA, USA). Student’s t-test, and ANOVA were performed to assess statistical significance. Statistical analysis of in vivo data was performed using a log-rank test for survival studies with p < 0.05 deemed significant.
In vivo study design
A cohort of U87R-Luc2 tumour-bearing mice (n = 10) underwent repeated CE-CT imaging at week-3, week-6, week-9 and week-12 post implantation (Fig. 2a). Late timepoint (Week-9 and Week-12) images were combined for analyses due to low number of remaining animals (n = 3 and n = 2 remaining at Week-4).
Bioluminescence imaging: Weekly BLI was performed22 with an IVIS Spectrum (Perkin Elmer, Waltham, MA, USA) as previously described. Imaging was carried out under anesthesia (1.5% isoflurane/100% O2) on a heated stage. 15 min prior to imaging, mice received 150 mg/kg luciferin (Perkin Elmer, Waltham, MA, USA) via subcutaneous injection. A 1 s reference image was taken (binning = 4, F-stop = 1). Living Image software (V4.3.1, Perkin Elmer Waltham, MA, USA) was utilised for BLI image analysis and average radiance (p/s/cm2/sr) was analysed.
Immunohistochemistry
Post-mortem, whole brains were excised, rinsed in Dulbecco’s-(D)PBS solution and fixed in 4% formaldehyde (48 h). Tissues were embedded in paraffin and 5 μm thick sections cut. Routine hematoxylin and eosin (H&E) staining was performed to facilitate histological evaluation. Standard immunohistochemistry methods were used to stain for Ki67 and CD-31 (Mouse IgG; 1:150 dilution; Cell Signaling Technology, London, UK).
Preclinical CT Image acquisition and reorientation
Longitudinal CT images were acquired on the TRIUMPHX-O-CT system (LabPet 4, X-O CT) (1.5% isoflurane/100% O2). 0–1 min prior to imaging 300ul warmed iodine based-contrast (300 mg iodine/mL41) was administered via intravenous lateral tail-vein injection. CE-CT images were acquired at 50 kV, 200 projections, voxel size 120 µm, FOV 61.44 mm, slice thickness 2 mm and 88 µA. Delineation of each reconstructed CT DICOM was carried out using PMOD (version 3.9; PMOD Technologies). DICOMs were reoriented to the same focal plane for visual assessment (Fig. S1). To prevent inter-observer variability, two experts semi-automatically delineated regions of interest (ROI). 3D Volume of interests (VOIs) were delineated for both right hemisphere (RH; tumour-implanted hemisphere) and the left hemisphere (LH; non-tumour-implanted hemisphere), with a threshold determined per image to exclude bone from the generated bounding boxes. Specifically, features that completely represent the tumour-implanted hemisphere were selected via segmentation of the right hemisphere (RH). Features that represent the non-tumour-implanted hemisphere were selected via segmentation of the left hemisphere (LH).
Patient CT Image acquisition and segmentation
Cross-sectional and publicly available GBM patient CT (n = 10) images were downloaded from The Cancer Genome Atlas Glioblastoma Multiforme (TCGA-GBM) data collection42 (The Cancer imaging archive (TCIA)28 (https://www.cancerimagingarchive.net/)). Tumour and normal tissue were manually delineated from baseline (pre-treatment) scans (Fig. 4e) using the polygon tool and thresholding in ITKSnap software34.
CT-radiomic feature extraction
Radiomic features are extracted over the whole ROI representing the left or right hemisphere using PyRadiomics (V2.7.7) (Harvard Medical School, Boston, MA, USA)25. Extraction parameters applied were: original = {}, wavelet = {}, bin width = 25, correctMask = true, interpolator = 2, resampledPixelSpacing = [2.5, 0.390625, 0.390625] (‘Extraction Parameter File’, Supplementary Materials). A fixed bin width of 25 was used for discretisation of the image grey level. Feature classes extracted (n = 843 total features) include First Order Statistics, Shape-based features, Gray Level Cooccurence Matrix (GLCM), Gray Level Run Length Matrix (GLRLM), Gray Level Size Zone Matrix (GLSZM), Neighbouring Gray Tone Difference Matrix (NGTDM), Gray Level Dependence Matrix (GLRLM), and finally the same features extracted from wavelet filtered versions of images. Mathematical definitions of each feature is located in online pyRadiomics documentation.
Analytical pipeline
R software (version 3.5.2, R Foundation for Statistical Computing, Vienna, Austria; http://www.r-project.org) was employed for all the statistical analysis.
Reduction of preclinical data dimensionality: To avoid overfitting (large number of extracted features (n = 843) and low sample number can find many spurious correlations), all shape features were removed (n = 14, Fig. S2; highly conserved between LH and RH). Remaining features underwent predictive analysis38 as follows. In all, outcome was assigned (0-LH; Normal tissue, 1-RH; tumour tissue) and datasets partitioned into training and validation cohort (80%:20% random split). Inter-correlated features were removed (determined in training dataset by pairwise Spearman correlation (> 0.8543) and removal of most highly correlated features). Reduction of clinical data dimensionality: All shape features (n = 14) were removed from downstream analyses.
Analysis of preclinical data: A decision tree-based recursive feature elimination method was applied to the training dataset, and recursive feature elimination performed using the recursive feature elimination (RFE) function (Caret package, version 6.0–8441; Cross-Validated (CV) via Repeated CV, five-fold, repeated 5 times). Most informative and non-redundant CT-radiomic features were selected to train a random forest, and to measure performance area under the receiver operator characteristic (ROC) curve (AUC) was calculated (pROC version 1.15.3). AUC, sensitivity and specificity are reported for each RCV (Fig. 3b). R packages implemented throughout are tabulated within supplementary materials (Supplementary Table 1). Assignment of randomised outcomes and re-analysis via the aforementioned pipeline was subsequently performed to validate detection of signal vs noise (Data not shown). Analysis of clinical data: CT-radiomic features identified in the analyses of preclinical data (LH/non- tumour-implanted hemisphere vs RH/tumour-implanted hemisphere analysis) were univariately analysed across normal and tumour regions of segmented clinical GBM CT images. Trends in feature intensity between tumour and normal regions were identified and demonstrated via box plot. Longitudinal radiomic features were not verified in clinical datasets due to the absence of a longitudinal clinical imaging dataset.
Delta Radiomic analysis: Feature-level changes were calculated by the relative net change between features from LH and RH (∆features = [featuresRH-featuresLH]/featuresLH). The Boruta algorithm44 (version 7.0.0), which implements a wrapper around a random forest classification algorithm, was employed to identify delta radiomic features of importance (Fig. S6) across timepoints (Week-3, -6, -9/12). Importance scores were generated across features and Tentative Rough Fix performed to assess weaker features. Features ‘confirmed important’ exhibit a feature Z-score > Maximum Z-score among shadow attributes.
Ethics approval and consent to participate
Protocols were approved by the University College Dublin Animal Research Ethics Committee. Animal experiments were carried out under Directive 2010/63/EU of the European Parliament on protection of animals used for scientific purposes. All sections of this manuscript adhere to ARRIVE Guidelines. All methods were carried out in accordance with relevant guidelines and regulations.
Data availability
The datasets analysed during this study are available from the corresponding author on reasonable request.
Abbreviations
- 95% CI:
-
95% Confidence interval
- AUC:
-
Area under the curve
- BLI:
-
Bioluminescence imaging
- CRC:
-
Colorectal cancer
- CT:
-
Computed tomography
- GBM:
-
Glioblastoma
- MRI:
-
Magnetic resonance imaging
- OS:
-
Overall survival
- VOI:
-
Volume-of-interest
References
White, K. et al. New hints towards a precision medicine strategy for IDH wild-type glioblastoma. Ann. Oncol. https://doi.org/10.1016/j.annonc.2020.08.2336 (2020).
White, K. et al. Identification, validation and biological characterization of novel Glioblastoma Tumour Microenvironment subtypes: Implications for precision immunotherapy. Ann. Oncol. https://doi.org/10.1016/j.annonc.2022.11.008 (2022).
Sottoriva, A. et al. Intratumor heterogeneity in human glioblastoma reflects cancer evolutionary dynamics. Proc. Natl. Acad. Sci. USA 110(10), 4009–4014. https://doi.org/10.1073/pnas.1219747110 (2013).
Shukla, G. et al. Advanced magnetic resonance imaging in glioblastoma: A review. Chin. Clin. Oncol. 6(4), 40–40. https://doi.org/10.21037/cco.2017.06.28 (2017).
Ellingson, B. M., Wen, P. Y., Van Den Bent, M. J. & Cloughesy, T. F. Pros and cons of current brain tumor imaging. Neuro Oncol. https://doi.org/10.1093/neuonc/nou224 (2014).
Lundy, P. et al. The role of imaging for the management of newly diagnosed glioblastoma in adults: A systematic review and evidence-based clinical practice guideline update. J. Neurooncol 150(2), 95–120. https://doi.org/10.1007/s11060-020-03597-3 (2020).
Singh, H., Maurya, V. & Gill, S. S. Computerised tomography features in gliomas. Med. J. Armed Forces India 58(3), 221–225. https://doi.org/10.1016/S0377-1237(02)80134-4 (2002).
Chinot, O. L. et al. Response assessment criteria for glioblastoma: Practical adaptation and implementation in clinical trials of antiangiogenic therapy. Curr. Neurol. Neurosci. Rep. 13(5), 347. https://doi.org/10.1007/s11910-013-0347-2 (2013).
Wen, P. Y. et al. Updated response assessment criteria for high-grade gliomas: Response assessment in neuro-oncology working group. J. Clin. Oncol. 28(11), 1963–1972. https://doi.org/10.1200/JCO.2009.26.3541 (2010).
Rudie, J. D., Rauschecker, A. M., Bryan, R. N., Davatzikos, C. & Mohan, S. Emerging applications of artificial intelligence in neuro-oncology. Radiology 290(3), 607–618. https://doi.org/10.1148/radiol.2018181928 (2019).
Beig, N., Bera, K. & Tiwari, P. Introduction to radiomics and radiogenomics in neuro-oncology: Implications and challenges. Neurooncol. Adv. https://doi.org/10.1093/noajnl/vdaa148 (2020).
Sanduleanu, S. et al. Tracking tumor biology with radiomics: A systematic review utilizing a radiomics quality score. Radiother. Oncol. 127(3), 349–360. https://doi.org/10.1016/j.radonc.2018.03.033 (2018).
Skogen, K. et al. Diagnostic performance of texture analysis on MRI in grading cerebral gliomas. Eur. J. Radiol. 85(4), 824–829. https://doi.org/10.1016/j.ejrad.2016.01.013 (2016).
Skogen, K., Ganeshan, B., Good, C., Critchley, G. & Miles, K. Measurements of heterogeneity in gliomas on computed tomography relationship to tumour grade. J. Neurooncol. 111(2), 213–219. https://doi.org/10.1007/s11060-012-1010-5 (2013).
Hu, L. S. et al. Multi-parametric MRI and texture analysis to visualize spatial histologic heterogeneity and tumor extent in glioblastoma. PLoS One 10(11), 1–14. https://doi.org/10.1371/journal.pone.0141506 (2015).
Zhang, L., Giuste, F., Vizcarra, J. C., Li, X. & Gutman, D. Radiomics features predict cic mutation status in lower grade glioma. Front. Oncol. 10(June), 1–16. https://doi.org/10.3389/fonc.2020.00937 (2020).
Beig, N. et al. Radiogenomic analysis of hypoxia pathway reveals computerized MRI descriptors predictive of overall survival in glioblastoma. Med. Imag. Comput. Aided Diagn. https://doi.org/10.1117/12.2255694 (2017).
Zinn, P. O. et al. A coclinical radiogenomic validation study: Conserved magnetic resonance radiomic appearance of periostin-expressing glioblastoma in patients and xenograft models. Clin. Cancer Res. 24(24), 6288–6299. https://doi.org/10.1158/1078-0432.CCR-17-3420 (2018).
Abdelwahab, M. G., Sankar, T., Preul, M. C. & Scheck, A. C. Intracranial implantation with subsequent 3D in vivo bioluminescent imaging of Murine gliomas. J. Vis. Exp. https://doi.org/10.3791/3403 (2011).
Maes, W. et al. In vivo bioluminescence imaging in an experimental mouse model for dendritic cell based immunotherapy against malignant glioma. J. Neurooncol. 91(2), 127–139. https://doi.org/10.1007/s11060-008-9691-5 (2009).
Yahyanejad, S. et al. Complementary use of bioluminescence imaging and contrast-enhanced micro-computed tomography in an orthotopic brain tumor model. Mol. Imaging https://doi.org/10.2310/7290.2014.00038 (2014).
Jarzabek, M. A. et al. In vivo bioluminescence imaging validation of a human biopsy-derived orthotopic mouse model of glioblastoma multiforme. Mol. Imaging 12(3), 1–12. https://doi.org/10.2310/7290.2012.00029 (2013).
Kothari, G. et al. The impact of inter-observer variation in delineation on robustness of radiomics features in non-small cell lung cancer. Sci. Rep. https://doi.org/10.1038/s41598-022-16520-9 (2022).
Johnston, A. L. M. et al. The p75 neurotrophin receptor is a central regulator of glioma invasion. PLoS Biol. 5(8), e212. https://doi.org/10.1371/journal.pbio.0050212 (2007).
van Griethuysen, J. J. M. et al. Computational radiomics system to decode the radiographic phenotype. Cancer Res. 77(21), e104–e107. https://doi.org/10.1158/0008-5472.CAN-17-0339 (2017).
Çinarer, G., Gürsel, B. & Haşim, A. Prediction of glioma grades using deep learning with wavelet radiomic features. Appl. Sci. https://doi.org/10.3390/APP10186296 (2020).
Qin, J. B. et al. Grading of gliomas by using radiomic features on multiple magnetic resonance imaging (MRI) sequences. Med. Sci. Monit. 23, 2168–2178. https://doi.org/10.12659/MSM.901270 (2017).
F. W. Prior et al., ‘TCIA: An information resource to enable open science’, in 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), IEEE, Jul. 2013, pp. 1282–1285. https://doi.org/10.1109/EMBC.2013.6609742.
Park, J. E. et al. Radiomics prognostication model in glioblastoma using diffusion- and perfusion-weighted MRI. Sci. Rep. https://doi.org/10.1038/s41598-020-61178-w (2020).
Malkov, S. et al. Mammographic texture and risk of breast cancer by tumor type and estrogen receptor status. Breast Cancer Res. https://doi.org/10.1186/s13058-016-0778-1 (2016).
Jeong, J. et al. Machine-learning based classification of glioblastoma using delta-radiomic features derived from dynamic susceptibility contrast enhanced magnetic resonance images. Quant. Imaging Med. Surg. 9(7), 1201–1213. https://doi.org/10.21037/qims.2019.07.01 (2019).
Chang, Y. et al. An investigation of machine learning methods in delta-radiomics feature analysis. PLoS One 14(12), 1–14. https://doi.org/10.1371/journal.pone.0226348 (2019).
Brancato, V. et al. Impact of radiogenomics in esophageal cancer on clinical outcomes: A pilot study. World J. Gastroenterol. 27(36), 6110–6127. https://doi.org/10.3748/wjg.v27.i36.6110 (2021).
Yahyanejad, S. et al. ‘Complementary use of bioluminescence imaging and contrast-enhanced micro-computed tomography in an orthotopic brain tumor model. Mol. Imaging 13, 7290 (2014).
Molotkov, A. et al. 3D optical/CT as a preclinical companion imaging platform for glioblastoma drug development. Drug Deliv. 27(1), 1686–1694. https://doi.org/10.1080/10717544.2020.1833381 (2020).
S. C. Jost, L. Collins, S. Travers, D. Piwnica-Worms, and J. R. Garbow, ‘Measuring brain tumor growth: A combined BLI/MRI strategy’.
Bausart, M. et al. Mismatch between bioluminescence imaging (BLI) and MRI when evaluating glioblastoma growth: Lessons from a Study Where BLI Suggested “Regression” while MRI Showed “Progression”. Cancers https://doi.org/10.3390/cancers15061919 (2023).
O’Farrell, A. C. et al. Implementing systems modelling and molecular imaging to predict the efficacy of BCL-2 inhibition in colorectal cancer patient-derived xenograft models. Cancers https://doi.org/10.3390/cancers12102978 (2020).
Connor, K. et al. Targeting the rhogef βpix/cool-1 in glioblastoma: Proof of concept studies. Cancers 12(12), 1–19. https://doi.org/10.3390/cancers12123531 (2020).
Workman, P. et al. Guidelines for the welfare and use of animals in cancer research. Br. J. Cancer 102(11), 1555–1577. https://doi.org/10.1038/sj.bjc.6605642 (2010).
Kirschner, S. et al. Imaging of orthotopic glioblastoma xenografts in mice using a clinical CT scanner: Comparison with micro-CT and histology. PLoS One https://doi.org/10.1371/journal.pone.0165994 (2016).
Zanfardino, M., Pane, K., Mirabelli, P., Salvatore, M. & Franzese, M. TCGA-TCIA impact on radiogenomics cancer research: A systematic review. Int. J. Mol. Sci. https://doi.org/10.3390/ijms20236033 (2019).
Peerlings, J. et al. Stability of radiomics features in apparent diffusion coefficient maps from a multi-centre test-retest trial. Sci. Rep. 9(1), 1–10. https://doi.org/10.1038/s41598-019-41344-5 (2019).
Kursa, M. B. & Rudnicki, W. R. Feature selection with the boruta package. J. Stat. Softw. 36(11), 1–13. https://doi.org/10.18637/jss.v036.i11 (2010).
Acknowledgements
We sincerely thank the Beaumont hospital Neuropathology department for their contribution to this manuscript and the project which provided the foundation for this study.
Funding
This study was financially supported by an RCSI Industry Seed Fund Award (RCSI) and a Beaumont hospital (BH) foundation award. A.T.B. and K.W. were further supported by the “GLIOTRAIN” (http://www.gliotrain.eu) award, a Horizon 2020 Research and Innovation program funded under the Marie Skłodowska-Curie ETN initiative (Grant Agreement #766069). J.C. was supported by the Beaumont Hospital Cancer Research and Development Trust. A.T.B is further supported by a Higher Education Authority North–South Research Programme “RadCOL”. Research was further funded by the Health Research Board (ILP-POR-2022–007). The authors acknowledge financial support from Brain Tumour Ireland (to ATB) . A private research funding donation to ATB and KS is also acknowledged.
Author information
Authors and Affiliations
Contributions
The following contributions were made by the authors; study conceptualization: A.T.B; funding acquisition: A.T.B.; methodology, A.T.B. H.C.W., P.L.; investigations and formal analysis, K.C., E.C., K.W., L.P.S., J.C., K.J.S., S.K., A.I.; resources: W.M.G., F.B., J.B.C., J.H., D.O’B.; writing-original draft preparation, K.C., A.T.B.; writing-review and editing, all authors especially K.C., E.C., H.C.W., and A.T.B. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Connor, K., Conroy, E., White, K. et al. A clinically relevant computed tomography (CT) radiomics strategy for intracranial rodent brain tumour monitoring. Sci Rep 14, 2720 (2024). https://doi.org/10.1038/s41598-024-52960-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-024-52960-1
- Springer Nature Limited