1 Introduction

The commercially prepared partial dentures are removable or of fixed type depending on patient health, age, glucose level, etc. [1]. Dentures may have clasps and metal frameworks designed to hold the denture in the oral cavity as artificial replacement [2]. In spite of the fact that clinician’s ability and experience play a noteworthy part in forming and creation of partial denture [3], clinician’s final judgment still prevails on the exactness of the final denture prepared [4]. Also, the fabrication of partial dentures and metal frameworks includes manual procedure that requires skill and experience and may take quite a while to finish [5,6,7]. However, sometimes partial dentures provide less power of chewing as that of natural teeth and may be risky and irritating [8]. Computer-aided design/computer-aided manufacturing (CAD/CAM) advancements in the dentistry may help overcome issues of manual work [9, 10]. Reverse engineering (RE) under CAD/CAM involves the process of creating a three-dimensional (3D) CAD component by capturing the surface outline shapes of physical component for designing by extricating the design sequence of current part and the process sequence of manufacturing and design is re-engineered [11,12,13,14]. Earlier, digital casts depended upon subtractive methods, which were widely used for construction of dental restorations and sacrificial patterns [15]. Delivering higher- and more-uniform-quality dentures/metal frameworks relied exclusively on CAD/CAM techniques and was used commercially for producing/standardizing dentures with low production and labour costs in less time [16]. Nowadays, additive manufacturing (AM) techniques have progressed vastly in dental applications with accurate and high-rate production [17, 18]. These techniques have the ability to overcome identified disadvantages such as fit problems caused by CAD/CAM techniques. Since 1990s, AM techniques were used in dentistry to construct complex shaped 3D models [19]. AM in dentistry is called as perfect fit and different applications have been successfully proposed due to the high reproducibility and quality. Some of the examples are maxillofacial implants, partial dentures, metal frameworks surgical guides, zirconia dentures, full denture and wax patterns for different prosthetic aids [20,21,22]. Latest studies using AM techniques allow digital dental 3D surveying prior to the fabrication of dentures and sacrificial pattern frameworks [23]. The AM techniques such as fused deposition modelling (FDM), vat polymerization, selective laser sintering (SLS), pro-jet printing, digital light projection (DLP), material jetting and fused filament deposition (FFF) are very commonly used in clinical dentistry. The AM approach has some advantages in dentistry such as elimination of inter-operator variation, repeatability, manufacturing time reduction and low cost [24,25,26]. The FDM process has capability for producing cost-effective tailor-made products at low cycle time that are best suited for dental applications [27, 28]. In the past some researchers have prepared denture samples using double distilled water and sea water with higher W/P ratio (than recommended by commercial manufacturers) that has significant effects on the setting time, hardness and compressive strength [29]. Similarly, dimensional accuracy by comparison of different die materials has good response by using AM technology [30, 31]. Surface finish is also a considerable factor in the cast restoration margin evenness/fineness [32, 33]. In dentistry the dental casting alloys are classified mainly into high noble alloys (gold and platinum), noble alloys (silver, gold and copper) and base metal alloys (Ni-based, Co-based and Ti-based). For metal restoration and crown making, base metal alloys may be used [34, 35].

In clinical dentistry commercially, gold alloys (high noble alloys) have been used. However, Ni–Cr-based alloys replace the other alloys irrespective of their excellent properties due to less cost involved. Among other alloys, Ni–Cr became popular also because of their capability of producing light and thin frameworks with excellent mechanical properties and satisfactory corrosion resistance [36,37,38]. Mechanical properties have some effect on Ni–Cr-based alloy with respect to casting and melting procedures [39]. The published literature outlined that W, H of water and weight proportion of N in Ni–Cr-based alloy are some of the main factors that affect the output properties of partial dentures made by AM and cast by centrifugal casting (CC). However, hitherto, very less work has been reported for fabrication of partial dentures by FDM (one of the AM techniques) and cast by CC from multifactor optimization viewpoint. The aim of this study is to ascertain the conditions for optimum values of ∆d, Ra and HV. Further, multifactor optimization has been employed from field engineer viewpoint so that the finally prepared partial dentures can be commercially used without further required iterations.

2 Methodology and experimentation

In the present work, patient-specific biomedical component (dental crown) has been selected as the benchmark as shown in figure 1.

Figure 1
figure 1

Benchmark component.

Starting from the benchmark as shown in figure 1, this study is formally divided into 12 steps/stages to prepare the final cast of partial dentures. The process of casting of partial denture begins with a dental impression of the patient’s teeth (stage 1). This dental impression prepared was further used for formal diagnostic impression/cast. After obtaining appropriate dental impression/cast, gypsum, high-strength stone also known as artificial stone is used to make the final cast of teeth mould (stage 2). The dental investment (refractory material) is mixed (mixture of bonded investment and water) by taking three different W by weight (100/12, 100/15, 100/18) using different H of water (pH-3, pH-7, pH-10). An optical scanner (three-dimensional (3D) representation) collected the surface information (exact size and shape) of the plaster cast (teeth mould) of the patient in the form of digital data and were saved in 3D software, which were then used to shape the partial denture framework and pre-process the data with reference to the scanned digital model. The CAD model of the partial denture has been made, and then converted into a standard triangulation language (STL) file to build the partial denture of ABS (material) with FDM (stages 3–5). Thereafter, attachment of sprue and ring liner placement are done in the crucible before investing. After this, investment is poured slowly around the pattern tree in the crucible (stages 6–7). Burn-out and baking process of investment by placing in a muffle furnace for 1.5 h at 900°C was performed in subsequent stages (stages 8–9). A Ni–Cr-based alloy was used for castings of partial denture on the induction casting set-up (stages 10–11). After solidification, the final casting fitted on the denture mould was procured (stage 12, figure 2). Based on previous literature, a cause and effect diagram has been prepared for predicting best settings of input parameters (see figure 3). The levels selected for various parameters are shown in table 1.

Figure 2
figure 2

Steps involved in making partial denture.

Figure 3
figure 3

Cause and effect diagram.

Table 1 Input parameters and levels for experimentation.

The Δd value of one critical dimension of 10.70 mm was selected as a benchmark (see figure 1). A Mitutoyo-SJ-410 roughness tester (as per ISO-1997 at 0.5 mm/s stylus speed and 0.25 mm cut-off length) was used to measure the benchmark component values of Ra, and Δd was measured using a Mitutoyo Vernier calliper (accurate up to 0.01 mm). The hardness of the cast has been measured using a micro-Vickers (HV) hardness tester.

For preparation of denture through CC, parameters were selected and altered as per Taguchi L9 orthogonal array. After getting all the observations in the form of outputs from the mechanical testing, results were analysed for multifactor optimization and ANOVA analysis using MINITAB© software. Table 2 shows the chemical composition of the Ni–Cr alloy for casting of partial dentures. Based upon table 1, table 3 shows the control log of experimentation based upon Taguchi L9 orthogonal array and the outputs Δd, Ra and HV.

Table 2 Ni–Cr alloy (%) for casting of partial denture.

3 Results and discussion

Further based upon table 3, table 4 shows the signal to noise ratio of Δd (SNRA1), Ra (SNRA2) and HV (SNRA3).

Table 3 Results of output parameters according to Taguchi L9 orthogonal array.

Based upon table 4, figure 4 shows the main effects plot for mean S/N ratios for Δd, Ra and HV. As observed from figure 4, for Δd, best settings are W of 100/12, pH-7 with 61% of N in Ni–Cr alloy. Since Δd, Ra have been computed for lower the better type case, the W of 100/12 is but obvious as less proportion of water results in less contraction after solidification and hence less dimensional deviations and better surface finish. The pH of 7 provides a neutral binding agent and the least proportion of N in Ni–Cr alloy results in better dimensional as well as surface roughness, which may be because of more grain refinement (the same may be ascertained from photomicrographs). For Ra, the best settings are W 100/15, pH-7 with 65% of N. For HV the best settings are W 100/15, pH-10 with 61% of N.

Table 4 SNRA data of output parameters according to Taguchi L9 orthogonal array.
Figure 4
figure 4

Main effects plot for mean S/N ratios for (Δd, Ra, HV). Note: Δd, Ra have been computed for lower the better type case and HV for higher the better type case.

Tables 5 and 6, respectively, show the ranking of input parameters (based upon responses of S/N ratios) and percentage contributions for Δd, Ra and HV.

Table 5 Response of S/N ratios for output parameters.
Table 6 Percentage contribution for various responses.

As observed from table 6, W has the maximum contribution for ∆d and Ra, whereas for HV the maximum contribution is N. These results are at 95% confidence level.

Further response optimization for all the three S/N ratios given in table 3 has been performed using Minitab software (see table 7). For maximization of all the S/N ratios, equal weight and importance has been given. The fit for the same has been calculated in table 8. As observed from table 8, the composite desirability for the proposed model is 0.698139, which gives promising outcomes to the best settings for all responses as a whole.

Table 7 Response optimization: SNRA3, SNRA2 and SNRA1.
Table 8 Best setting obtained with best signal to noise ratios.

Based upon multi-regression analysis, multi-response predictor has given an optimized setting for the best results (see table 9).

Table 9 Optimum values proposed by the software for castings.

The predicted setting is 2, 2, 1, which could be demonstrated as the 2nd level of W, i.e., (100/15), 2nd level of H of water, i.e., pH-7 and 1st level of N, i.e., 61%. The values obtained at this level are supposed to be the best values. Finally, after regression analysis based on outputs of S/N ratio a linear model (regression equation) has been suggested.

3.1 Regression equation

3.1a Regression equation for SN ratio of ∆d:

$$ {\text{SNRA}}1 = 22.714 + 3.243W\_100/12{-}2.187W\_100/15-1.056W\_100/18-1.170H\_3 + 3.009H\_7-1.840H\,{\text{value}}\_10 + 0.843N\_61 + 0.391N\_65-1.233N\_70. $$
(1)

Here W100/12, W_100/15, W_100/18, H_3, H_7, H_10, N_61, N_65 and N_70 have been taken from table 4. After putting the values form table 4 in Eq. (1), final maximized value has been obtained.

$$ \begin{aligned} & {\text{SNRA}}1 = 22.714 + \left( {3.243 \times 25.96} \right){-}\left( {2.187 \times 20.53} \right){-}\left( {1.056 \times 21.66} \right){-}\left( {1.170 \times 21.54} \right) + \left( {3.009 \times 25.72} \right){-}\left( {1.840 \times 20.87} \right) + \left( {0.843 \times 23.56} \right) + \left( {0.391 \times 23.10} \right){-}\left( {1.233 \times 21.48} \right), \\ & {\text{SNRA}}1 = 55.32743\,\,({\text{predicted}}\,{\text{value}}). \\ \end{aligned} $$

Similarly, for SN ratio of ∆d, final minimum value of the property has been predicted with the help of the following relations:

Following Eq. (2) and putting values in it from table 4

$$ {\text{SN}}\,{\text{ratio}} = {-}\,10\log X\,\,({\text{standard}}\,{\text{equation}}\,{\text{for}}\,{\text{finding}}\,{\text{SN}}\,{\text{ratio}}) $$
(2)
$$ \begin{aligned} & \;\;55.32743 = {-}\,10 \, \log X \\ & X = 10^{{{-}5.532743}} \\ & X = 2.93263 \times 10^{{{-}6}} . \\ \end{aligned} $$

Now put the value of X in the next equation:

$$ X = \left( {1/n} \right)\sum Y^{2} $$
(3)
$$ \begin{aligned} 2.93263 \times 10^{{{-}6}} & = Y^{2} \,\,\left( {{\text{here}}\,n = 1} \right) \\ & Y^{2} = 2.93263 \times 10^{{{-}6}} \\ & Y = 0.001712492 \, ({\text{minimum}}\,{\text{value}}\,{\text{of}}\,\Delta d) \\ \end{aligned} $$

where Y is the value of the property.

Similarly, for SN ratio of Ra, final minimum value of the property has been predicted with the help of the following relations.

3.1b Regression equation for SN ratio of Ra:

$$ {\text{SNRA}}2 = {-}16.02{-}\left( {0.56 \times {-}16.58} \right) + \left( {2.92 \times {-}13.10} \right){-}\left( {2.37 \times {-}18.39} \right){-}\left( {1.72 \times {-}17.74} \right) + \left( {1.77 \times {-}14.25} \right){-}\left( {0.05 \times {-}16.07} \right){-}\left( {1.08 \times {-}17.10} \right) + \left( {0.99 \times {-}15.03} \right) + \left( {0.09 \times {-}15.93} \right), $$
(4)
$$ {\text{SNRA}}2 = 6.8455. $$

Rewriting Eq. (2) and putting values in it from table 4

$$ {\text{SN}}\,{\text{ratio}} = {-}10\log X\,\,({\text{standard}}\,{\text{equation}}\,{\text{for}}\,{\text{finding}}\,{\text{SN}}\,{\text{ratio}}) $$
$$ \begin{aligned} & 6.8455 = {-}10 \, \log X \\ & \,\,X = \, 10^{{{-}0.68455}} \\ & \,\,X = \, 0.206752134. \\ \end{aligned} $$

Now put value of X in the next equation:

$$ \begin{aligned} & X = \left( {1/n} \right)\sum Y^{2} \\ 0.206752134 = Y^{2} & \left( {{\text{here}}\,n = \, 1} \right) \\ & Y^{2} = 0.206752134 \\ & Y = 0.454700048 \, ({\text{minimum}}\,{\text{value}}\,{\text{of}}\,R_{a} ). \\ \end{aligned} $$

3.1c Regression equation for SN ratio of HV:

$$ {\text{SNRA}}3 = 44.7041{-}\left( {0.2718 \times 44.43} \right) + \left( {0.4166 \times 45.12} \right){-}\left( {0.1448 \times 44.56} \right){-}\left( {0.2220 \times 44.48} \right){-}\left( {0.1386 \times 44.57} \right) + \left( {0.3606 \times 45.06} \right) + \left( {0.4016 \times 45.11} \right) + \left( {0.3324 \times 45.04} \right){-}\left( {0.7341 \times 43.97} \right), $$
(5)
$$ {\text{SNRA}}3 = 45.978499. $$

Rewriting Eq. (2) and putting values in it from table 4

$$ \begin{aligned} {\text{SN}}\,{\text{ratio}} = & {-}10\log X\,\,({\text{standard}}\,{\text{equation}}\,{\text{for}}\,{\text{finding}}\,{\text{SN}}\,{\text{ratio}}) \\ & \quad \quad 45.978499 = {-}10\log X \\ & \quad \quad \,\,X = 10^{{{-}4.5978499}} \\ & \quad \quad \,\,X = 2.52435 \times 10^{{{-}5}} . \\ \end{aligned} $$

Now put value of X in the next equation:

$$ \begin{aligned} & X = \left( {1/n} \right)\sum 1/Y^{2} \\ 2.52435 \times 10^{{{-}5}} = & 1/Y^{2} \,\,({\text{here}}\,n = 1) \\ & \quad \quad \quad Y^{2} = 1/2.52435 \times 10^{{{-}5}} \\ & \quad \quad \quad Y = 199.0329362\,\,({\text{maximized}}\,{\text{value}}\,{\text{of}}\,{\text{HV}}). \\ \end{aligned} $$

The predicted value of S/N ratios that comes out after solving the model equation has values very near to the obtained/deduced values in table 3. Hence, this verifies the validity of the macro-model. Figure 5 shows the optimization plot after regression analysis based on outputs of SN ratios.

Figure 5
figure 5

Optimization plot.

In order to ascertain the metallurgical properties, photomicrographs were taken [40] for all sets of experiments as per table 3 using a metallurgical microscope at ×100 magnifications. Figure 6 shows the photomicrographs for all nine samples as per table 3.

Figure 6
figure 6

Photomicrographs of final nine castings on magnification (×100).

The grain size and porosity were also examined on greyscale. Table 10 shows the grain size no. G against grain size diameter as per ASTM E1382 and porosity (%) as per ASTM B276.

Table 10 Grain size and porosity of 9 experiments.

As observed from table 10, experiment no. 4 has minimum porosity followed by experiment no. 6. Further, actual average grain size diameter for experiment no. 6 is the smallest; also the hardness observed is maximum (see table 3). This may be because of combined effect of porosity level and average grain size.

To correlate hardness with dendrite structure, comparison of samples 6 and 7 has been made (see figure 7). As observed from figure 7 at low magnification (× 30), surface texture is observed to have more waviness, whereas at high magnification (× 400) dendrite size and spacing observed are of large dimensions. The average grain size diameter for experiment number 6 was Φ37.8–44.9 µm and for experiment number 7 it was Φ63.50–75.50 µm; corresponding porosity for experiment number 6 was 40.2% and for experiment number 7 it was 66.52%. Hence, average grain size of partial denture cast in experiment no. 6 is relatively fine with less % of porosity in comparison with cast prepared in experiment no. 7 with high % of porosity. Hence, the partial denture cast with coarse grains in experimental no. 7 resulted in less hardness as compared with partial denture cast with fine grain structure in experiment no. 6. These results are in line with the observations made by other investigators [18, 31, 32, 40,41,42].

Figure 7
figure 7

Photomicrographs of experiments 6 and 7.

In order to ascertain the chemical composition of cast components, figure 8 shows the XRD graph with 61% of N (for sample no. 6 as per table 3), which confirms the presence of alloying elements in final functional prototype as per table 2.

Figure 8
figure 8

XRD graph for exp. no. 6.

4 Conclusions

This study highlights the multifactor optimization for mechanical properties of Ni–Cr-based partial dentures prepared by AM assisted with CC. The regression equations have been deduced for predicting the S/N ratios and output parameters.

The results of study suggest that for controlling the dimensional features and surface roughness of the partial dentures, the most important factor is ‘W’ followed by ‘N’ in Ni–Cr alloy.

For hardness of partial dentures, the most important factor is ‘N’.

The proposed optimized settings resulted in more uniform grain size of Φ37.8–44.9 µm and controlled porosity level of 40.2% acceptable in clinical dentistry.

Finally, from overall multifactor optimization viewpoint for field applications the best settings are W-100/15, H-pH7 and N-61%Ni proportion in Ni–Cr alloy.