The purpose of our work was to evaluate contrast-detail performance for a range of full field digital mammography systems using Hotelling observer SNR analysis and ascertain whether it can be considered an alternative to CDMAM evaluation. Five FFDM systems were evaluated, which differed in generation (age), Automatic Exposure Control (AEC) behaviour, tube/target combination and detector type. Contrast-detail performance was first analysed using CDMAM phantom analysis and then using the Hotelling observer SNR methodology. The Hotelling observer SNR was calculated for input signal originating from gold discs of varying thicknesses and diameters and then used to estimate the threshold gold thicknesses for each diameter as per CDMAM analysis. There were small differences between the two techniques, especially in small diameter details, which can be attributed to structural characteristics of the CDMAM phantom. The Hotelling observer SNR technique showed lower variability than results from CDMAM analysis. Overall, the Hotelling observer SNR methodology showed variations in the FFDM systems performance consistent with previous findings, demonstrating its value as a performance assessment metric.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
References
Van Engen, R., Young, K., Bosmans, H., Thijssen, H.: The European protocol for the quality control of the physical and technical aspects of mammography screening. Euref, Luxembourg (2006)
Young, K., Johnson, B., Bosmans, H., Van Engen, R.: Development of minimum standards for image quality and dose in digital mammography. In: Digital Mammography IWDM 2004, Durham NC, USA (2005)
Young, K., Alsager, A., Oduko, J., Bosmans, H., Verbrugge, B., Geerste, T., et al.: Evaluation of software for reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6913, p. 69131C (2008)
Young, K.C., Cook, J.J.H., Oduko, J.M., Bosmans, H.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: Proc. SPIE, vol. 6142, p. 614206 (2006)
Sandrik, J., Wagner, R.: Absolute measures of physical image quality: measurement and application to radiographic magnification 9(4), 540-9 (1982)
Barrett, H., Yao, J., Rolland, J., Myers, K.: Model observers for assessment of image quality. Proc. Natl. Acad. Sci. 90(21), 9758–9765 (1993)
Kyprianou, I.S.: A method for total x-ray imaging system evaluation. PhD Thesis. University of New York, Buffalo, NY (2004)
Kyprianou, I.S., Rudin, S., Bednarek, D., Hoffman, K.: Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: application to a new microangiographic system. Med. Phys. 32(2), 613–626 (2005)
Kyprianou, I., Ganguly, A., Rudin, S., Bednarek, D., Gallas, B., Myers, K.: Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment. In: Proc. Soc. Photo. Opt. Instrum. Eng., vol. 5749, pp. 251–262 (2005)
Liu, H., Kyprianou, I.S., Badano, A., Myers, K.J., Jennings, R.J., Park, S., et al.: SKE/BKE Task-based methodology for calculating Hotelling observer SNR in mammography. In: Proc. of the SPIE, Medical Imaging, vol. 7258 (2009)
Liu, H., Badano, A., Chakrabarti, K., Kaczmarek, R., Kyprianou, I.: Task specific evaluation of clinical full field digital mammography systems using the Fourier definition of the Hotelling observer SNR. In: Proc. of the SPIE, Medical Imaging, vol. 7622 (2010)
Liu, H.: Task specific evaluation methodology for clinical Full Field Digital Mammography. PhD Thesis. University of Maryland, College Park (2012)
Commissioning and routine testing of Full Field Digital Mammography Systems. NHSBSP Equipment Report 0604. NHS Cancer Screening Programmes, Sheffield. Report No.: version 4 (in press)
Marshall, N.: A comparison between objective and subjective image quality measurements for a full field digital mammography system 51(10), 2441–63 (2006)
Wagner, R.F., Brown, D.: Unified SNR analysis of medical imaging systems. Phys. Med. Biol. 30, 489–518 (1985)
Burgess, A.: Comparison of receiver operating characteristic and forced choice observer performance measurement methods. Medical Physics 22(5), 643 (1995)
Review of measurements on full field digital mammography systems. NHSBSP Equipment Report 0901. NHS Cancer Screening Programme (2009)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Delakis, I., Wise, R., Morris, L., Kulama, E. (2014). Comparative Performance Evaluation of Contrast-Detail in Full Field Digital Mammography (FFDM) Systems Using Ideal (Hotelling) Observer versus Automated CDMAM Analysis. In: Fujita, H., Hara, T., Muramatsu, C. (eds) Breast Imaging. IWDM 2014. Lecture Notes in Computer Science, vol 8539. Springer, Cham. https://doi.org/10.1007/978-3-319-07887-8_24
Download citation
DOI: https://doi.org/10.1007/978-3-319-07887-8_24
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-07886-1
Online ISBN: 978-3-319-07887-8
eBook Packages: Computer ScienceComputer Science (R0)