Introduction

Modern technology of reinforced soil walls began in the 1960s, with inclusion of metallic strips in the compacted fill along with a wall face to acquire and maintain stability. Polymeric geosynthetics was later used as an alternative to metallic strips as reinforcement. These reinforced soil walls are designed by considering the inclusions as quasi-tieback tension members and commonly designed by using methods such as AASHTO Specifications [4], FHWA method [6], and NCMA method [11]. They are collectively referred to as Mechanically Stabilized Earth (MSE) walls. MSE walls with geosynthetics as reinforcement have sometimes been referred to as Geosynthetic Mechanically Stabilized Earth or simply GMSE.

Reinforcement spacing for GMSE walls is typically between 0.3 and 0.9 m. The relatively wide spacing stems from a fundamental design concept of a tieback system. In a tieback system, spacing of tieback plays a very minor role, as it is the total resisting force that matters. The significant beneficial effects of placing sheet reinforcement on small spacing, however, have gained increasing attention in recent years. The significant benefits of close reinforcement spacing were first realized in actual construction, and later validated by many field-scale experiments (1, 3, 7, 12, 19, 21). These experiments have confirmed that reinforcement spacing plays a far greater role than reinforcement strength in the capacity of a reinforced soil system. It has also been established that the behavior of reinforced soil with closely spaced geosynthetic reinforcement can be accurately characterized as a soil-geosynthetic composite [20, 21].

Geosynthetic Reinforced Soil (GRS) emerged as a new reinforced soil technology, as an alternative to GMSE, in the mid-2000s. GRS is designed by taking advantage of improved engineering characteristics of soil with closely spaced reinforcement [2]. The interaction between soil and closely spaced reinforcement forms a composite that relies on geosynthetics inclusion to reinforce the soil internally, and its stability does not rely on external support offered by the wall face. It should be noted that in the literature, the term GRS has sometimes been referred to all geosynthetic reinforced soil structures regardless of how it is designed.

Geosynthetic Reinforced Soil (GRS) bears strong resemblance to GMSE, in that both systems comprise three major components: compacted backfill, horizontally placed geosynthetic reinforcement, and facing (typically, dry-stacked concrete block facing). The main difference between the two systems lies in the fundamental design concepts. GRS considers the closely spaced geosynthetic sheets as reinforcing elements in a soil-geosynthetic composite (hence the term reinforced in GRS). GMSE, on the other hand, considers the reinforcement as quasi-tieback elements to help stabilize a pre-defined potential failure wedge (hence the term stabilized in GMSE). In GRS, wall facing serves as a façade, as a protective element to prevent sloughing of soil, and as a construction aid; whereas in GMSE, facing is a load-carrying component, hence failure of a GMSE wall can be imminent if the facing fails. Due to the difference in design concept, reinforcement spacing of a GRS system usually ranges from 0.1 m (4 in.) in zones immediately beneath large concentrate vertical loads to 0.3 m (12 in.), with 0.2 m (8 in.) being typical, to acquire significant beneficial effects of soil-geosynthetic interaction, whereas the reinforcement spacing in a MSE system is usually much larger (0.3~0.9 m, or 12~36 in.), with 0.6 m (24 in.) being typical, to reduce construction time. Note that in the design of a tieback system, spacing of tieback presumably has little bearing on performance.

In current practice of earth retaining wall construction, GMSE enjoys much greater popularity than GRS. One reason for this is because GMSE is designed within the context of an externally stabilized wall system, of which the face is a structural component to retain soil and to resist earth pressure, much like, reinforced concrete gravity walls, cantilever reinforced concrete walls, anchored retaining walls, etc. Externally stabilized walls have been used for over a century. As with any paradigm change, many design engineers are either uncomfortable with or unaware of internally stabilized soil walls that rely on the reinforcing effect of tensile inclusion; as a result, many internally stabilized wall systems have incorporated some structural components of externally stabilized retaining walls to enhance stability, and many hybrid internally-externally stabilized GMSE walls have been built.

A majority of current design methods adopt the tieback design concept for these walls and have indirectly encouraged the use of wide reinforcement spacing. The result is a failure rate that is much too high to be considered a sound system. The National Concrete Masonry Association has estimated a 2 to 8% failure rate nationally for GMSE walls. Berg [5] and Valentine [17] have estimated that the failure rate of GMSE walls in the USA is as high as 5%. Koerner and Koerner [10] reported a database of 141 failed GMSE Walls, of which 107 were actual collapse, and 34 were unserviceable due to excessive deformation. Holtz [9] indicates that bulging of wall face is an issue for GMSE walls. In a recent survey, many state DOTs list excessive bulging and deformation as a top concern for GMSE walls [8].

This paper reports a study undertaken to investigate stress-deformation behavior of soil-geosynthetic composites for GRS in plane strain condition. The analytical model was critically validated by comparing simulated displacements with measured external and internal displacements of one unreinforced and four soil-geosynthetic composite (SGC) tests in plane strain condition. These tests vary in reinforcement stiffness/strength, reinforcement spacing, and confinement condition. Using the validated analytical model, stress distribution within the soil-geosynthetic composites when subject to increasing vertical pressures was examined to gain insight into the stresses in soil-geosynthetic composites. A parametric study was also conducted to examine the influence of reinforcement spacing, reinforcement stiffness, soil stiffness and strength on stress-deformation behavior of soil-geosynthetic composites. This paper describes validation of the analytical model, presents the stress distribution in soil-geosynthetic composites under different vertical pressures, and discusses findings of the parametric study.

Representative Soil-Geosynthetic Composites and SGC Tests

Due to the presence of geosynthetic inclusion, a reinforced soil mass is inherently non-uniform. To investigate stress-deformation behavior of a non-uniform mass, the dimensions of a representative test specimen are of critical importance. A series of finite element analyses were initially performed to determine the dimensions of a test specimen needed in order to adequately characterize soil-geosynthetic composite behavior on 0.2-m reinforcement spacing in plane strain conditions [13, 20]. With a length/height ratio of 0.7, specimen heights of 7.0, 2.0, 1.0, and 0.5 m under a plane strain condition were examined numerically. Considering a soil-geosynthetic composite of 7.0 m high by 4.9 m wide with reinforcement spacing of 0.2 m as a prototype composite mass, it was found that specimen heights H = 1.0 m and H = 0.5 m are too small to provide adequate representation, but that a 2.0-m high by 1.4-m long specimen would provide sufficiently accurate (within ± 10% deviations) representation for the composite. For purposes of comparison, a parallel series of finite element analyses were also performed for soil specimens without any reinforcement. Specimen height as small as 0.5 m was found to yield nearly the same stress-strain-volume change relationships as those of a uniform soil mass of H = 7.0 m when no reinforcement was present. This suggests that while a small specimen is adequate for investigating behavior of a uniform soil mass, a much larger specimen is needed for investigating reinforced soil behavior.

Table 1 lists the conditions of the SGC tests. The test specimens were 2.0 m in height, 1.4 m in length, and 1.2 m in width (in the plane strain direction). Since these tests replicate the reinforcement spacing used in actual construction in the field, the term “field-scale” is used for description. All five experiments were performed in a plane strain condition (see Fig. 1). The backfill material used in the tests was A-1-a crushed diabase material, a well graded gravelly soil (GW) with largest particle size of 33 mm, and was compacted to 98% per ASTM D698. Relevant properties of the backfill are as follows: specific gravity of soil solids = 3.0, percentage of fines = 14.6%, maximum dry unit weight = 24.1 kN/m3, and optimum water content = 5.2%. Five large-size (diameter = 152 mm, height = 305 mm) consolidated drained triaxial tests were performed at confining pressures ranging from 34 to 760 kPa (5 to 110 lb/in2). The stress-strain-volume change relationship is shown in Fig. 2. The Mohr-Coulomb strength parameters are as follows: c (cohesion) = 70 kPa, ϕ (angle of internal friction) = 48° for confining pressures of 35, 105, and 210 kPa. The reinforcement used in the tests was a woven polypropylene geotextile with a wide width tensile strength, per ASTM D4595, of 70 kN/m, in both warp and fill directions. The reinforcement of Test 3 was formed by gluing two sheets of the geotextile together. Wide-width tensile tests performed on the glued specimen show that the stiffness and strength were approximately twice those of a single sheet geotextile. Detailed information of the SGC tests has been presented by Pham [13] and Wu et al. [21].

Table 1 Test conditions of one unreinforced test (Test 1) and four SGC tests (Tests 2, 3, 4, and 5)
Fig. 1
figure 1

Field-scale plane strain Soil-Geosynthetic Composite (SGC) test

Fig. 2
figure 2

a Stress-strain behavior and b volume change behavior of the diabase in triaxial compression tests

Finite Element Simulation of Soil-Geosynthetic Composites

Finite element (FE) method of analysis was employed to simulate the field-scale SGC experiments described in section “Representative Soil-Geosynthetic Composites and SGC Tests”. The analysis was conducted by using the finite element code Plaxis 8.2. In the analysis, geosynthetic reinforcement was simulated by a linear elastic model, of which the material parameters are shown in Table 2. The soil-reinforcement contact surface was assumed to be fully bonded. Use of interface elements along soil-reinforcement contact surface in the analysis was also performed. The interface friction angle of (2/3) tan ϕ = 36° and interface adhesion of (2/3) c = 46.7 kPa were assumed. The results were nearly identical with or without interface elements, which confirmed that the assumption of fully bonded soil-reinforcement interface was valid.

Table 2 Material parameters for the finite element analysis

The hardening soil model was selected for simulation of the behavior of the fill material in the SGC tests. It is a second-order hyperbolic elasto-plastic hardening model involving friction hardening to express the plastic shear strain in deviatoric loading and cap hardening to express the plastic volumetric strain in primary compression. The model was selected because it is capable of simulating many important soil characteristics, such as stress-dependency, non-linearity, stress-path dependency, and dilatancy. The soil parameters of the hardening soil model determined from drained triaxial compression tests at relevant confining pressures are included in Table 2. These parameters are average values at confining pressures of 35, 105, and 210 kPa (or 5, 15, and 30 psi), the range of confining pressure relevant to the SGC experiments. Note that there was no calibration or back-calculations involved in parameter selection. A detailed description of the material parameters, including how they were obtained, has been given by Wu and Tung [22]. The following describes validation of the analytical model by comparisons with measured vertical strains (section “Model Validation by Vertical Strains”), lateral displacement profiles (section “Model Validation by Lateral Displacement Profiles”), and internal displacements at selected points (section “Model Validation by Internal Displacements at Selected Points”) of the SGC tests.

Model Validation by Vertical Strains

Comparisons of simulated and measured applied vertical pressure vs. vertical (axial) strain relationships of the five field-scale SGC tests are shown in Fig. 3. For Tests 3 and 4, the agreement between simulated and measured behavior was excellent up to 1000 kPa; for Test 2, the agreement was excellent up to 2000 kPa. Past these pressures, measured deformation became increasingly larger than simulated values. It was suspected that this could be a result of large deformation under high applied pressures not being accounted for in the analyses. The analyses were repeated using updated Lagrangian analysis in which the finite element mesh was continuously updated during the calculation. The analysis results differed insignificantly from those of small strain analyses. It is reasoned that the discrepancy at high applied pressure is mainly because the hardening soil model does not account for any time-dependent deformation, whereas the measured value does include significant time-dependent deformation at higher applied pressures. Regardless, a 1000 kPa vertical pressure is five times the typical design pressure for typical GRS abutments which indicates that the model is capable of providing a good simulation of vertical deformation, especially at service level conditions.

Fig. 3
figure 3

Comparisons of simulated and measured applied vertical pressure vs. vertical (axial) strain relationships of the five SGC tests

Model Validation by Lateral Displacement Profiles

Comparisons of simulated and measured lateral displacement profiles under various applied vertical pressures for the five field-scale SGC tests are shown in Fig. 4. It is seen that there is a good overall agreement between the modeled and measured lateral displacement profiles under all levels of applied vertical pressure for all five experiments.

Fig. 4
figure 4

Comparisons of simulated and measure lateral displacement profiles under various applied vertical pressures for the five SGC tests

Model Validation by Internal Displacements at Selected Points

Internal movements at selected points of the soil-geosynthetic composites in the SGC tests were monitored using grid lines marked on the lubricated latex membrane system. Previous study of the lubrication technique indicates that the friction angle with the plaxiglass side wall is less than one (1.0) degree [18]. Details of the system have been previously described by Pham [13] and Wu et al. [21]. Comparisons of simulated and measured internal displacements at five selected points in Test 2 (reinforcement strength Tf, reinforcement spacing sv) and Test 3 (reinforcement strength 2*Tf, reinforcement spacing 2*sv) are shown in Fig. 5. The simulated and measured path of the internal movement at the selected points illustrate that the agreement is excellent at every selected point under all pressure levels.

Fig. 5
figure 5

Comparisons of simulated and measure internal displacements at five selected points when subject to increasing vertical pressure for a Tests 2 and b Test 3 [note: point 5 is not shown in this figure to avoid confusion]

Analysis of Stress Distribution in Soil-Geosynthetic Composites

A distinct advantage with finite element analysis of earth structures is the ability to analyze stresses in the soil mass that are otherwise very difficult to measure accurately during physical experiments. Of course, this advantage can only be realized if the stresses obtained by finite element analysis method are reliable, i.e., if the analysis results agree with “all” measured displacement fields of the entire earth structure. In this study, the comparison of the simulated and measured external and internal displacements agreed well, hence provides an opportunity to examine stresses within a SGC with good confidence.

Figure 6a, b shows distributions of vertical stress and lateral stress, respectively, within the unreinforced soil mass (Test 1) and reinforced soil mass (Test 2) (with Tf = 70 kN/m and sv = 0.2 m) under applied vertical pressure of 10 kPa. Note that 10 kPa vertical pressure corresponds to a typical design load for non-load-bearing walls subjected to the normal traffic condition. Note also that the reinforcement strength and reinforcement spacing of Test 2 is typical for GRS abutments and walls. The results indicate the vertical stresses within the unreinforced soil mass and the reinforced soil mass are essentially the same. The lateral stresses of the two soil masses, however, are evidently different, with the lateral stress in the reinforced soil mass being higher, especially near the reinforcement layers. The higher lateral stress within the reinforced soil mass is due to higher restraint of lateral deformation resulting from bonding at the soil-reinforcement interface. Greater confining pressure leads to higher stiffness and strength of a soil; greater compressive lateral stress resulting from geosynthetic inclusion leads to a stiffer and stronger SGC. The benefit of increased lateral stress has long been identified as a reinforcing mechanism of reinforced soil (e.g., [16, 23]). The stress distributions seen in Fig. 6 also confirm that.

Fig. 6
figure 6

Distributions of a vertical stresses and b lateral stress within the soil mass in Test 1 (unreinforced) and Test 2 (reinforced), under applied vertical pressure of 10 kPa

Figure 7a, b shows distributions of vertical stress and lateral stress, respectively, within the unreinforced soil mass (Test 1) and reinforced soil mass (Test 2) (with Tf = 70 kN/m and sv = 0.2 m) under applied vertical pressure of 200 kPa. Note that 200 kPa is a typical design load commonly used for GRS bridge abutments [6]. It is seen that the vertical stresses in the unreinforced and reinforced soil masses are nearly the same, with the latter being slightly lower than the former. The lateral stress in the reinforced soil mass is again higher than in the unreinforced soil mass, especially near the vertical face of the reinforced soil mass. The higher lateral stress in the reinforced soil mass is a result of higher restraint of lateral deformation due to soil-reinforcement friction.

Fig. 7
figure 7

Distributions of a vertical stress es and b lateral stress within the soil mass of in Test 1 (unreinforced) and Test 2 (reinforced), under applied vertical pressure of 200 kPa

Figure 8a, b shows distributions of vertical stress and lateral stress, respectively, in the unreinforced soil mass (Test 1) and reinforced soil mass (Test 2) (with Tf = 70 kN/m and sv = 0.2 m) under applied vertical pressure of 600 kPa. The vertical pressure corresponds to a surcharge that is three times a typical design load for GRS bridge abutments. It is seen that the vertical stresses in the reinforced soil mass are significantly lower than that in the unreinforced soil mass. This indicates that the closely spaced reinforcement layers generate positive arching in the reinforced soil mass under high surcharge (600 kPa in this case). The lateral stress distribution within reinforced soil mass is again seen to be higher than that in the unreinforced soil mass. The increase in lateral stress is seen to be more pronounced under 600 kPa vertical pressure than under 200 kPa. The positive arching (in terms of vertical stress) in conjunction with increased lateral stress results in lower shear stress levels, hence a composite that is less likely to reach a failure condition.

Fig. 8
figure 8

Distributions of a vertical stresses and b lateral stress within the soil mass in Test 1 (unreinforced) and Test 2 (reinforced), under applied vertical pressure of 600 kPa

Parametric Study

A parametric study was conducted to examine the influence of six factors, including reinforcement axial stiffness (EA), reinforcement spacing (sv), cohesion (c), friction angle (ϕ), dilation angle (ψ), and soil stiffness parameters (E50, Eur & Eoed) on stress-deformation behavior of soil-geosynthetic composites. The parametric study was performed by selecting a baseline soil-geosynthetic composite with a common set of material and geometric parameters given in Table 3. When studying the effect of a certain factor, all parameters are kept the same as in the baseline case except for the particular parameters under investigation.

Table 3 Parameters for the baseline case of parametric study

In addition to the baseline case, a total of 14 cases were analyzed. The 14 cases are divided into six groups, each group is to examine a particular factor, as shown in Table 4. Note that, when appropriate, the parameters are varied by a ratio of 1/3 and 3 of the value in the baseline case. Table 4 also shows the figure number in which results of each group are presented.

Table 4 Groups of parametric study

Figure 9 shows the influence of reinforcement axial stiffness, represented by the product of Young’s modulus (E) and cross-sectional area (A), on vertical pressure vs. vertical strain and vertical pressure vs. maximum lateral strain relationships. As expected, higher EA value of reinforcement results in a stiffer SGC. It is interesting to note that the influence of reinforcement axial stiffness (EA) is negligible up to vertical pressure of about 400 kPa. However, as the vertical pressure exceeds 400 kPa, the effect of EA becomes more significant. Note also that the effect of EA is noticeably greater as it changes from 1/3*EA (233 kN/m) to EA (700 kN/m) than from EA (700 kN/m) to 3*EA (2100 kN/m).

Fig. 9
figure 9

Influence of reinforcement axial stiffness (EA) on load-deformation behavior of SGCC

The influence of vertical reinforcement spacing (sv) on vertical pressure vs. vertical strain and vertical pressure vs. maximum lateral strain relationships is shown in Fig. 10. The anticipated response was that the stiffness of SGC would increase with closer reinforcement spacing. However, Fig. 10 indicates that when vertical pressure is less than 400 kPa, the influence of reinforcement spacing on both vertical and lateral deformation is negligible for sv between 0.1 and 0.4 m. The influence of varying reinforcement spacing from 0.2 to 0.4 m on deformation becomes significant when vertical pressure exceeds 400 kPa. For sv between 0.1 and 0.2 m, the deformation is essentially unaffected when vertical pressure is between 400 and 1000 kPa. For reinforcement spacing of 0.4 m, the analysis indicates that failure will occur at vertical pressure of 1000 kPa. The effect of reinforcement spacing as noted above needs to be viewed with caution because it was tacitly assumed that the stiffness of the soil in the soil mass is unaffected by the reinforcement spacing. The presence of the reinforcement is known to restrain lateral deformation of the soil due to soil-reinforcement friction. As a result, the compaction-induced stress (i.e., residual lateral stress due to the loading/unloading process of a compaction load) will be more pronounced in a reinforced soil mass with smaller reinforcement spacing. The higher the compaction-induced stress, the higher the lateral stress, hence higher soil stiffness. This effect is not accounted for in the analysis shown in Fig. 10.

Fig. 10
figure 10

Influence of reinforcement spacing (sv) on load-deformation behavior of SGC

The influence of Mohr-Coulomb strength parameter c (cohesion) on vertical pressure vs. vertical strain and vertical pressure vs. maximum lateral strain relationships of the SGC is shown in Fig. 11. As illustrated, the influence of cohesion on vertical pressure vs. vertical strain is very small. The effect is slightly more pronounced for vertical pressure vs. maximum lateral strain relationship, although the effect is still quite small. The analysis also indicates that the SGC will fail during construction (when the 6th soil lift was placed) for the SGC with zero cohesion. The results of c = 0 are therefore not included in Fig. 11.

Fig. 11
figure 11

Influence of cohesion (c) on load-deformation behavior of SGC [note: for c = 0, the soil mass failed as the 6th soil lift was placed]

Figure 12 shows the vertical pressure vs. vertical strain and vertical pressure vs. maximum lateral strain relationships of the SGC as Mohr-Coulomb strength parameter ϕ (angle of internal friction) varied from 38° to 53°; the baseline friction angle was 48°. For vertical pressure leading to 400 kPa, the influence of ϕ on vertical pressure vs. vertical strain and vs. maximum lateral strain relationships is negligible; however, when vertical pressure exceeds 400 kPa, the effect of ϕ becomes significant for ϕ = 38° and 43°; for higher ϕ-values (ϕ = 48° and 53°), the threshold pressure is at about 1000 kPa for significant difference in deformation. The analysis also indicates that reinforcement near the mid-height will rupture at vertical pressure of about 1500 kPa for ϕ = 38°.

Fig. 12
figure 12

Influence of angle of friction (ϕ) on load-deformation behavior of SGC [note: for ϕ = 38°, reinforcement layer #5 ruptured at applied vertical pressure of 1500 kPa]

The influence of angle of dilation (ψ) of the fill material on load-deformation behavior of SGC as ψ varies from 0 to 30° is shown in Fig. 13. The influence of ψ on vertical pressure vs. vertical strain relationship is very small up to a threshold pressure of 500 kPa. Above 500 kPa, the influence of ψ is modest, except for ψ ≤ 10° for which the threshold vertical pressure is about 1000 kPa. Above the threshold pressure, the vertical stiffness generally increases with ψ-value. The influence of ψ on vertical pressure vs. maximum lateral strain relationship is also negligible up to vertical pressure of 500 kPa; above 500 kPa, the lateral stiffness generally increases with increasing vertical pressure. The analysis also indicates that for ψ = 0°, reinforcement near the mid-height will rupture under an applied vertical pressure of 1600 kPa.

Fig. 13
figure 13

Influence of angle of dilation (ψ) on load-deformation behavior of SGC [note: for ψ = 0°, layer #5 ruptured at applied vertical pressure of 1600 kPa]

Soil stiffness, as characterized by parameters E50, Eur, and Eoed, had by far the greatest influence on vertical and lateral load-deformation behavior of SGC. Among all factors investigated, soil stiffness is the only one that has appreciable effect on stress-deformation relationships of SGC under vertical pressure of 200 kPa, a typical design pressure for GRS bridge abutments. This confirms that soil stiffness is the most important material parameter that influences the stress-deformation behavior of SGC. As expected, the higher the soil stiffness, the stronger the SGC (see Fig. 14). Note that the relationship between soil stiffness and SGC stiffness is not linear, in that the difference in SGC stiffness between soil stiffness 1/3*E and E is significantly greater than that between E and 3*E.

Fig. 14
figure 14

Influence of soil stiffness (E50, Eur, and Eoed) on load-deformation behavior of SGC

Concluding Remarks

Geosynthetic Reinforced Soil (GRS) differs from MSE with Geosynthetics as reinforcement (GMSE) in the design concept. For the former, closely spaced geosynthetics layers interact with surrounding soil to form soil-geosynthetic composites, whereas for the latter geosynthetic layers are considered tension tieback elements to stabilize potential failure soil wedges. More attention is now being given to GRS due to concerns over performance issues and an alarmingly high failure rate of GMSE.

This study was undertaken to investigate stress-deformation behavior of soil-geosynthetic composites (SGC) by the finite element method of analysis. The finite element model used in this study accurately simulated “all” measured external (i.e., on exposed surfaces) and internal displacements of five sets of soil-geosynthetic composite tests under increasing applied vertical pressure. The five tests vary in reinforcement stiffness/strength, reinforcement spacing, and confinement condition. Successful simulation of all the tests suggests that the model is very reliable and can be used with confidence to analyze stress-deformation behavior of the soil-geosynthetic composites under the given set of conditions.

The study indicates that, under typical design loads (i.e., applied vertical pressure not more than 200 kPa), the vertical stresses in closely spaced reinforced soil and in unreinforced soil are practically the same. The lateral stresses, however, are significantly higher in reinforced soil than in unreinforced soil. For applied vertical pressure much greater than typical design loads, the vertical stresses in reinforced soil are significantly lower than those in unreinforced soil. In other words, positive arching occurred in the reinforced soil mass and is especially pronounced under high applied vertical pressure. The arching behavior tends to produce lower shear stress levels, hence less likely to reach a failure condition compared to unreinforced soils.

The parametric study conducted by using the validated analytical model allows examination of the influence of reinforcement stiffness, reinforcement spacing, soil strength, and soil stiffness on stress-deformation behavior of soil-geosynthetic composites. It suggests that as long as the fill is sufficiently stiff (as in the baseline case given in Table 3), reinforcement axial stiffness, reinforcement spacing, soil strength parameters all have negligible to very small influence on stress-deformation behavior of the soil-geosynthetic composites under 400 kPa applied vertical pressure. Soil stiffness is clearly the most important among all the factors. This confirms a rule of thumb: When it comes to improved performance of GRS, there is no substitute for high soil stiffness. Note that soil stiffness is affected by fill material type, fill placement condition, compaction equipment, and compaction lift.