Introduction

Due to growing industrialization and urbanization, environmental degradation has become a real issue. Industries and residences emit enormous amounts of organic and inorganic contaminants into water systems. Carbon-based pollutants such as phenolic compounds, insecticides, and pesticides severely affect the environment [1]. In addition, due to their potential carcinogenic effects, they deteriorate the underground water quality and affect human health once discharged into the environment [2]. On the other hand, lead, cobalt, chromium, cadmium, and many more heavy metals have significant health risks and must be purged before being released into the water, soil, or air [3]. These heavy metal ions are actively utilized in various industries, including electroplating, metallurgy, tanning, wood preservation, pulp and paper making, and paints and pigments manufacturing which contaminate and harm biological and ecological creatures. Therefore, metal differentiation is essential for understanding how metal ions behave in the environment. For example, Cr (VI) has been found to be harmful to people even though Cr (III) is not a significant environmental contaminant [4]. The environment's plentiful oxygen causes Cr (III) to be oxidized into Cr (VI), which is highly water soluble and potentially poisonous [5]. The presence of metal ions in an environment that exceeds the permitted limit is the source of severe health problems and even cancer [6, 7]. Coagulation [8], photocatalysis [9], ion exchange [10], reverse osmosis [11], adsorption [12], and other chemical and physical procedures are employed to remediate water-containing metallic pollutants [13]. Because of its broad applicability, improved selectivity, and cost-effectiveness in wastewater treatment processes, distribution by ion exchange materials has attracted people's curiosity for using this strategy [14, 15].

Nature has endowed us with a wide range of inorganic and organic ion exchange materials, each with unique characteristics and selectivity. Inorganic ion exchangers provide several advantages over organic resins, including better chemical and thermal stability at high temperatures. Nevertheless, inorganic ion exchangers have some drawbacks too, such as unsuitability for column operation because of their high cost, non-granulometric nature, irreproducibility of the results [15]. On the other hand, organic ion exchangers are cost-effective, produce reproducible results, and can treat of a large amount of wastewater. Therefore, composite ion exchange materials have received much attention because they combine the desirable features of their organic and inorganic counterparts in a single material [16]. Because of their specificity, selectiveness, and wide pertinence, composite ion exchangers are utilized for environmental cleanup [17].

Among various composites, fibrous ion exchangers based on thorium (IV) and cerium (IV) have versatile characteristics that make them very important in industrial and environmental applications [18]. Such materials have new applications in fuel cells, ion-selective electrodes, antimicrobial activity, ion transport, ion exchange, catalysis, etc. [19,20,21]. Additionally, biocomposite ion exchangers that combine the advantages of biopolymers and inorganic materials have drawn increased interest as adsorbents for removing various contaminants because of their organizational and functional abilities [22, 23]. Biopolymers like gum acacia, chitosan, cellulose acetate, and pectin have been incorporated as organic polymer components in biocomposites ion exchangers [24,25,26]. Many research studies have shown that pectin and pectin-rich materials have a high affinity for metallic ions, and thus act as effective biosorbents [27]. The performance of the composite's ion exchange is enhanced by the inclusion of various carboxyl and hydroxyl groups, which increase the active sites on the surface of the polymer matrix [28]. So, pectin-based composite ion exchangers have been shown to interact efficiently with inorganic compounds through molecular associations, and due to their fibrous nature, abundance, and broad surface area. Some pectin-based ion exchangers such as pectin–cerium tungstate, pectin cerium iodate, and pectin zirconium silicophosphate have shown the selectivity toward Zn2+, As3+, Cu2+, and Th4+, respectively [29,30,31]. But, to the best of our knowledge and as per our detailed literature survey, there is no available data on the preparation of pectin–cerium (IV) silicomolybdate (PCSM) composite ion exchanger that shows higher selectivity for Cr3+ ions and antimicrobial activities commonly exhibited from transition metals with organic moieties [32]. So, the synthesis of hybrid materials through chemical methods signifies one of the most captivating improvements in material chemistry [33,34,35].

The current study focuses on the following objectives: preparation of cerium (IV) silicomolybdate (CSM) and PCSM composite ion exchanger, its characterization, and its practical use as a metal adsorbent to remove toxic metals from water sources, as well as its antibacterial activity against Gram-negative bacteria Escherichia coli. Such studies of hybrid ion exchangers encourage the synthesis of multifunctional ion exchangers and may cause a substantial impact on underground water purification.

Experimental

Materials

For our experiments, pectin and chromium chloride (CrCl3) were purchased from Loba Chemie (Loba Chemie Pvt. Ltd., Mumbai, India). Whereas, ammonium ceric nitrate ((NH4)2Ce(NO3)6), cadmium chloride (CdCl2), lead nitrate (Pb(NO3)2), barium nitrate (Ba(NO3)2), ethylene diamine tetra acetic acid (EDTA) potassium hydroxide (KOH), sodium hydroxide (NaOH), sodium chloride (NaCl), hydrochloric acid (HCl), perchloric acid (HClO4), sodium perchlorate (NaClO4), and ammonium molybdate ((NH4)6Mo7O24) were purchased from Fisher Scientific (Fisher Scientific India Pvt. Ltd., Mumbai, India). Sodium silicate (Na2SiO3) was purchased from Otto Chemie (Otto Chemie Pvt. Ltd., Mumbai, India) and acetic acid (CH3COOH) was purchased from Merck (Merck, Darmstadt, Germany). The nickel nitrate (Ni(NO3)2), magnesium nitrate (Mg(NO3)2), zinc nitrate (Zn(NO3)2), strontium nitrate (Sr(NO3)2), ferric nitrate (Fe(NO3)3), calcium nitrate (Ca(NO3)3), cobalt nitrate (Co(NO3)3), nitric acid (HNO3), and acetone (CH3COCH3) were obtained from Central Drug House (Central Drug House Pvt. Ltd., New Delhi, India). Demineralized water (DMW) was procured from the lab itself and used for different solution preparation.

Instrumentation

First, the magnetic stirrer (2 MLH, Remi, Maharashtra, India) was used to well mix the calculated amount of chemicals. Thereafter, a digital Systronics pH meter-361 (Meter-361, Systronics, Gujrat, India) was used to measure the solutions’ pH. To observe various functional groups in the synthesized composite, we have used Fourier transform infrared spectroscopy (FTIR) technique. In this technique, the spectrum of the composite material was obtained by FTIR spectrophotometer (Spectrum Two FTIR spectrometer, PerkinElmer, Waltham, USA) using the KBr disc method. Furthermore, we used a standard optical system for the data collection over the range of 4000 to 400 cm−1. It also serves standard configuration of atmospheric vapor compensation. The X-ray diffractometry (XRD) studies were conducted by X-ray diffractometer (D8 advance, Bruker AXS Inc., Madison, USA). The X-ray patterns of the composites were recorded using Cu-Kα radiation with the wavelength 1.54 Å (corresponding energy is 8.04 keV) in the 2θ angle range from 5° to 80°. The step size and the smoothing width were 0.02° and 0.3°, respectively, along with the step time of 6.00 s. Thereafter, the morphology of the composite was examined using a scanning electron microscopy (SEM) (JSM 6510LV, JEOL Ltd., Tokyo, Japan). The energy-dispersive X-ray (EDX) spectroscopy with 20 kV accelerated voltage was performed to obtain the elemental composition of the composite with the help of the same equipment, JEOL-JSM 6510LV scanning electron microscope (JSM 6510LV, JEOL Ltd., Tokyo, Japan). Moreover, the particle size was determined by capturing TEM images using a transmission electron microscope (TEM2100, JEOL Ltd., Tokyo, Japan). After the characterization, we also examined the desired applications such as ion exchange capacity (IEC) and antibacterial activity. Therefore, to determine the ion exchange capacity of the synthesized composite, glass columns were used. To examine the growth curve of Escherichia coli, the absorbance was measured as a function of incubation time through an UV-2600i spectrophotometer (UV-2600i, Shimadzu Corporation, Kyoto, Japan).

Preparation of cerium (IV) silicomolybdate (CSM)

The CSM was synthesized by constantly agitating an aqueous Na2SiO3 solution and boiling (NH4)2MoO4. By adding 0.1 M HNO3 into the solution, the pH was adjusted in the range of 0–1. Thereafter, (NH4)2Ce(NO3)6 was added to this mixture. Then the mixture was kept under constant stirring for 3 h. The digestion of the compound was performed for 24–25 h at room temperature. The liquid was decanted, and the precipitate was washed with DMW and dried in a laboratory oven at 60 ± 2 °C. The compound was converted to H+ form by soaking in one molar HNO3 for a day with periodic shaking and repeatedly changing the supernatant with new acid. Finally, the solution filtration was done, and the precipitate was washed repeatedly with DMW to remove excess acid [36].

Preparation of the pectin–cerium (IV) silicomolybdate (PCSM) composite ion exchanger

Pectin gel was obtained by dissolving various quantities of pectin powder in DMW. Furthermore, PCSM was prepared by mixing pectin gels with CSM. The mixture was maintained at 55 °C for 3 h on a magnetic stirrer. The resulting light-yellow color precipitate was left at room temperature for 24 h until being digested. The gel was filtered after the supernatant was decanted. The surplus acid was washed away with DMW and processed at 55 °C in an air oven. The product was processed with 1.0 M HNO3 for 24 h with periodic stirring and the replacement of the supernatant liquid with new acid to convert the dried product to the H+ form. After many washes using DMW, the surplus acid was removed and the product was left to dry at 60 °C in an oven [36].

Ion exchange capacity (IEC)

Basically, ion exchange is a process in which the ions present in any aqueous solution are removed/replaced by the other ions attached to the exchanger. To measure the ability of the exchanger in exchanging the desired ion, we commonly examine the IEC of composite toward the specific metal ion in a particular solution. In our experiments, the column method was adopted to study the IEC of the material by placing 1.0 g of H+ type exchanger in a 1.0 cm diameter glass column. NaCl solution was used to extract the hydrogen ions. The collected effluent was then titrated with 0.1 M solution of NaOH. As per Eq. (1), the IEC (in meq/g) was calculated as [37]:

$${\text{IEC}} = \frac{av}{w},$$
(1)

Here “a” represents the molarity (mol/L) of the alkali, “v” represents the volume (mL) of the alkali applied in the titration, and “w” represents the exchanger's weight (g).

Impact of eluent concentration and the behavior of elution on IEC

The effectiveness of the column and the optimal eluent concentration required to remove H+ ions from PCSM was found by passing 250 mL of NaCl (having different concentrations) with a flow rate of 1.0 mL/min through a column containing 1.0 g of PCSM. The collected effluents were subjected to a 0.1 M NaOH solution for titration. Now, as per the observation of IEC for different concentrations of NaCl, 1.0 M concentration of NaCl was found to be suitable for studying elution behavior. Therefore, 1.0 M NaCl was used to elute the H+ ions from the PCSM completely. The effluent was collected in segments of 10 mL at a set flow rate and to calculate the H+ ions that were eluted out of the column, effluents were titrated against a solution of 0.1 M NaOH.

Thermal studies

As it is well known, polluted wastewater from industries is hot. So, hybrid ion exchangers should be thermally stable for utilizing them in the purification of polluted wastewater treatment. Hence, we studied the effect of various temperatures on the IEC of synthesized PCSM composite. The influence of heat on the IEC of PCSM was investigated by placing 1.0 g of the composite in H+ form in the muffle furnace at a temperature ranging from 100 to 600 °C for 1 h. Then after the cooling PCSM, the IEC of the samples was calculated by the column method as discussed in the “ion exchange capacity” section [38].

Chemical stability

The chemical stability of PCSM in various chemical solutions such as mineral acids (HCl, HNO3), alkalis (KOH, NaOH), and solvents (like acetone and acetic acid) was investigated through the chemical dissolution process. In this procedure, 0.5 g of PCSM was equilibrated with 50.0 mL of several chemical solutions for 24 h at room temperature. Then the excess acid, base, and other solutions were removed by washing and filtering. The remaining PCSM was washed with DMW and then dried to 60 °C. The chemical stability of PCSM was examined through the change of its color and weight. Eventually, the column method (or batch method) was used to calculate the IEC again.

Distribution studies

Distribution studies were performed to gauge the relative selectivity of the PCSM ion exchanger toward specific ions in particular solvents. Herein, the ion exchanger is considered to be highly selective for an ion in a particular solvent if the values of the distribution coefficient (Kd) are relatively larger for it. The batch approach was used to conduct distribution tests for several metal ions. In this technique, 0.4 g of PCSM exchanger in the form of H+ ions were added into 40 mL of different metallic solutions. Thereafter, to achieve the equilibrium, the mixtures were kept for 6 h at room temperature (~ 25 ± 2 °C) under continuous shaking. After achieving the equilibrium, concentrations of these metal ion solutions were analyzed by titrating them with EDTA. The volumetric determination was performed by taking the metal ion's initial and final concentrations after equilibrium. The values of distribution Kd were computed using Eq. (2) [39]:

$$K_{{\text{d}}} = \frac{I - F}{F} \times \frac{V}{W}.$$
(2)

The starting volume of the EDTA titrant is “I” (mL), the final volume is “F” (mL), the volume of the metal ions in mL is “V”, and the weight of the exchanger is “W” (g).

Binary separation

On the PCSM ion exchanger, binary separation of various metal ions was performed using the column method [40]. In this procedure, a glass column (with an internal diameter of 1.0 cm) with a glass wool support at the bottom was packed with 1 g of PCSM in the H+ form. Subsequently, the column was washed once or twice with DMW. Then the mixture of various metal ions (5 mL of 0.01 M metal ion solution) that is to be separated was loaded by passing it (flow rate 1.0 mL/min) through the column. This mixture was passed through the column at least four or five times for the complete adsorption of metal ions by PCSM. Now considering the Kd values of various metal ions present in different solvents on the PCSM column, different eluents were used to elute the metal ions adsorbed on the exchanger. Any metal ion having low Kd in a particular solvent elute first as they are weakly held in PCSM composite while metal ion having high Kd in some solvent elute second as they are strongly held in PCSM composite in comparison to former. Each 10 mL portion of the effluent was collected at a flow rate of 5–6 drops/min. Finally, the titrimetric method was used to quantify the metal ions in effluent using a 0.01 M disodium salt of EDTA.

Antibacterial activity

For a long time, microbial infections caused by several bacteria have been a foremost challenge in front of medical as well as sanitation industries [41]. In this study, the antibacterial activity of PCSM composite was examined against the bacteria Escherichia coli. For this purpose, the optical density technique was used to determine the antibacterial activity of the PCSM composite. First, Escherichia coli was aerobically grown in NB (nutrient broth) at 37 °C for 24.0 h. Thereafter, 13% of NB was autoclaved after being prepared in DMW. The bacterial culture was introduced to 100 mL DMW in the three individual flasks. Then 50.0 and 100.0 µg/mL of PCSM were added to the bacterial culture in two separate flasks, while the third one remained without an ion exchanger. The bacterial culture without the treatment of PCSM was considered as a negative control. The flasks were placed in an incubator shaker at 37 ± 1 °C. To monitor the bacterial concentration, 3 mL of suspension was taken from every flask to assess the optical density at 600 nm. The growth curve was plotted by taking optical density at 1 h intervals [30].

Results and discussion

The optimum ratio of the distinct reagents composing the CSM has to be determined. Consequently, various compositions of ammonium ceric nitrate, ammonium molybdate, and sodium silicate were tested to estimate the suitable CSM composition that yields the highest CSM's IEC (Table 1). CSM-3 exhibited the highest IEC (1.78 meq/g) among the prepared CSM compounds (Table 1), it was, thus, chosen to synthesize the PCSM inorganic–organic hybrid ion exchange of different compositions by mixing distinct quantities of pectin and CSM-3. It can also be observed from Table 1 that the mixing of pectin into CSM results in an improved IEC. This may be explained on the basis of higher active sites available on the surface area of the composite. The main reason for this observation can be rooted in the binding of organic polymer (pectin) with the inorganic moiety (CSM) that not only provide the mechanical strength and active sites for combining the replaceable H+ ions but also prevent dribbling of composite from columns [40]. Figure 1 shows the schematic illustration of the proposed chemical reaction, and hence the formation of PCSM. Apart from it, further addition of pectin beyond a specific concentration may cause a decrement in IEC due to the accumulation of active sites served by higher concentrations of pectin. Here in our case, according to the composite IEC analysis given in Table 1, PCSM-2 has a higher IEC (2.56 meq/g) compared to the other combinations and is better than its inorganic analog as well, calculated under similar conditions. Therefore, the sample having this combination (PCSM-2) was chosen for further investigations.

Table 1 Composition and some properties of the prepared CSM and PCSM ion exchanger composites
Fig. 1
figure 1

Proposed chemical reaction between CSM and pectin for PCSM composite synthesis

We have also determined the thermal stability of PCSM by examining changes of its IEC and color as a function of temperature during a drying process (Table 2). It is observed that as the temperature increases, the IEC decreases due to the organic counterpart's deterioration and the nanocomposite ion exchanger's physical denaturation [24, 34]. By heating up to 600 °C, it is found that the PCSM had average thermal stability as the IEC is now around 24.21% (0.62 meq/g as shown in Table 2) of the initial value (2.56 meq/g given in Table 1).

Table 2 Temperature effects on color and IEC of PCSM ion exchanger

In the same scenario, eluent concentration-dependent studies were also performed to analyze the suitable concentration of eluent for completely eluting the H+ ions from the PCSM ion exchanger columns. So, in this experiment, we used various concentrations of NaCl against the m mole of H+ ions from PCSM. It can be clearly depicted from Fig. 2a that 1 M NaCl is sufficient to completely elute the H+ ions from the PCSM exchanger column. Furthermore, Fig. 2b shows the maximum volume of NaCl that is required to completely release H+ ions is 120 mL. This much volume (= 120 mL) of NaCl is indicating the PCSM composite's good performance for complete elution of H+ in comparison to many existing pectin-based ion exchangers [26, 31].

Fig. 2
figure 2

a Effect of eluent concentration on PCSM's IEC and b elution behavior of PCSM ion exchanger

It can be clearly observed from Table 3 that the weight of the exchanger is reduced while color may or may not be changed after chemical treatment for 24 h. This table also enlightens that the chemical stability of PCSM is reduced in alkaline solutions as the weight of the exchanger and IEC is reduced. The possible reason behind weaker stability in such strong bases can be the moderated hydrolysis of exchangers at higher pH [24]. Furthermore, the PCSM ion exchanger was found chemically stable in HCl and HNO3 mineral acids at 0.1, 1.0, and 5.0 M concentrations, and also in CH3COOH and CH3COCH3 solvents at 1.0 M concentration.

Table 3 Chemical stability of PCSM against different chemicals: effects on PCSM's weight and IEC

Now to examine various structural and morphological parameters, we have opted for several characterization techniques. First, various functional groups were detected by observing the FTIR spectra of both CSM and PCSM ion exchangers [42]. Figure 3 shows the FTIR spectra of CSM and PCSM ion exchangers. In the FTIR spectrum of CSM (Fig. 2a), the broadband at 3400.90 cm−1 with a strong peak at 1622.64 cm−1 is due to the existence of –OH bending and stretching modes. Silicate ions are responsible for the peak at 1084.31 cm−1 [43]. A peak at 961.68 cm−1 is clearly indicating the presence of molybdate [17]. The absorption band in the 567.05 cm−1 area may be caused by Ce–O stretching [30]. CSM contains structural hydroxyl protons, as seen by the strong 1400.45 cm−1 band ascribed to the presence of Si–OH [36].

Fig. 3
figure 3

FTIR spectra of: a CSM, and b of PCSM with the designation of various peaks

The FTIR spectrum of PCSM shows a peak at 599.15 cm−1 assigned to oxides, and metal hydroxide bands (Fig. 3b) were detected. The C–O stretch of pectin in the PCSM is detected at 1019.74 cm−1 [30] and pectin’s C=O double bonds are seen at 1103.22 cm−1 [36]. The band at 1734.52 cm−1 is allocated to the presence of the C=O stretching band of the pectin’s ester group [29]. Moreover, the peak at around 3370.87 cm−1 is more or less the same as detected for CSM at 3400 cm−1. These above results prove the mixing of CSM with pectin without alteration of CSM structure. The presence of pectin peaks and little shift in the peaks of metal oxides and hydroxides in Fig. 3 attest to the formation of PCSM.

The XRD is one of the nondestructive experimental techniques used to characterize the crystalline structure, molecular orientations, grain size, molecular surface, and phase of materials. Henceforth, we have performed powder XRD on PCSM to analyze its crystalline nature. It can be noticed from Fig. 4 that the peaks observed in the PCSM XRD pattern (Fig. 4b) are of low intensities compared to those of the CSM (Fig. 4a). This outcome indicates a decrease in CSM crystallinity when mixed with pectin to form the hybrid PCSM ion exchanger. Indeed, the crystallinity index \(\left( { = \frac{{{\text{Sum}}\;{\text{of}}\;{\text{area}}\;{\text{under}}\;{\text{peaks}}}}{{{\text{Total}}\;{\text{area}}}} \times 100} \right)\) for CSM was 74.36%, which was then reduced to 56.42% after adding pectin. This result suggests that CSM and PCSM are semi-crystalline materials, with PCSM delineating the lowest crystallinity.

Fig. 4
figure 4

X-ray diffraction patterns of: a CSM and b PCSM

SEM was obtained at different magnifications to observe the morphology of the prepared CSM and PCSM composites (Fig. 5) [44]. It is evident from the SEM images that the PCSM composite has rough morphology with a well-defined flower petal-like structure (Fig. 5c, d). On the other hand, CSM does not have such a structural pattern (Fig. 5a, b). The different surface morphologies between PCSM and CSM hint toward the binding of pectin organic biopolymer with the inorganic ion exchanger material (CSM), and thus confirm the formation of the organic–inorganic PCSM hybrid ion exchanger [17].

Fig. 5
figure 5

SEM images of CSM (a, b) and PCSM (c, d) at various magnifications

The EDX analysis was achieved to examine the elemental compositions of CSM and PCSM composites, and the results are represented in the histogram of Fig. 6 [45]. The EDX analyses were carried out with an SEM and its adjunct EDX analyzer. Ce, Si, Mo, and O components were detected in the EDX spectrum of CSM, indicating that the CSM ion exchanger was synthesized without undesired chemical impurities (Fig. 6a). Peaks corresponding to O and C of the pectin molecular parts were detected in the EDX spectrum of the PCSM coexisting with the peaks of the Ce, Si, Mo, and O elements confirming the production of the hybrid composite (Fig. 6b).

Fig. 6
figure 6

EDX of: a CSM and b PCSM

PCSM particles size was analyzed with the help of TEM images [46]. According to the TEM examination shown in Fig. 7, PCSM composite exhibits particles with an average size in the range 26.2–55.2 nm in at least two dimensions but varying in the third one. On the other hand, the size of particles in the remaining one dimension may vary. Therefore, the PCSM exchanger can also be used as a nano-structured hybrid ion exchanger as two dimensions of the particles are determined to be in the nano-range. This is a very important finding from the industrial application point of view.

Fig. 7
figure 7

TEM image of PCSM ion exchanger particles with an average size of the nanoscale range in at least two dimensions

Withal the aforesaid characterizations, we have also assessed the selectivity of our composite toward the specific metal ion by analyzing the distribution behavior of the PCSM composite. So, the distribution behavior can be analyzed by observing the ratio of metal ions’ amount in the exchanger phase to the amount in the solution phase. One of the prominent methods to calculate this ratio in equilibrium conditions is the measurement of the Kd value as it gauges the affinity of the cation exchanger toward the counter metal ions. But, the wide variation of Kd depends not only on the nature of the ion exchanger but also on various other factors such as the type of metal ions, chemical bonds, concentration, pH, and nature of solvents. Therefore, we have performed the distribution studies and measured the Kd values of 11 metal ions (Ba2+, Sr2+, Ca2+, Mg2+, Pb2+, Cd2+, Co2+, Ni2+, Fe3+, Cr3+, and Zn2+) in different solvent systems using the batch method (as shown in Table 4) [47]. Equation (3) may schematically represent the ion exchange reaction process between the PCSM ion exchanger and the metal ions in contact [40].

$$2({\text{PCSM}} - {\text{H}}) + {\text{M}}^{2 + } \leftrightarrow ({\text{PCSM}})_{2} {\text{M}} + 2{\text{H}}^{ + } .$$
(3)
Table 4 Kd values of various metal ions present in different solvents on the PCSM column

Table 4 shows that some solvents promote the reduction of H+ ions from PCSM and show higher sorption of metal ions (i.e., showing high Kd values), while in some solvents, this process is weak and hence possesses low Kd values. It can also be observed from Table 4 that mixing two different solvents results in a further decrement of Kd values in comparison to both solvents individually. This behavior of the ion exchanger toward the metal ions can be explained on the basis of the higher polarity of mixed solvents in comparison to the individual one. Moreover, this table also revealed that the Kd values for 0.1 M solvents are lower in comparison to the 0.01 M solvents because of the significant excess of H+ ions in 0.1 M solvents which reverted the exchange process, and hence cause the low metal ions pickup [48]. One more promising aspect revealed by this table is the relatively highest Kd values of PCSM associated with Cr3+ ions in each of the investigated solvent systems showing, thus, the exchanger's high selectivity for Cr3+ ions.

By means of different Kd values of analyzed metal ions, we have also performed the binary separation of metal ions through the batch method. First, to select the suitable pair for binary separation, the separation factor (α) was calculated. It is defined as the ratio of Kd values associated with two different metal ions that are to be separated [49]. So α can be written as:

$$\alpha = \frac{{K_{{\text{d}}} ({\text{A}})}}{{K_{{\text{d}}} ({\text{B}})}},$$
(4)

where Kd(A) and Kd(B) are related to the ionic species A and B that are to be separated sequentially by eluents. For an α value higher than the unity, the selectivity for ion A is more important than for B. In other words, the higher will be the value of α, the more effective will be the separation of ion A over B. Based on the value of α calculated using Kd of ions in DMW and Eq. (4), we have selected four pairs (Cd2+–Cr3+, Pb2+–Cr3+, Ni2+–Cr3+, and Co2+–Cr3+) of metal ions and associated solutions for binary separations as enlisted in Table 5. Finally, by applying selected eluting agents in succession, metal ions are sequentially eluted through the column to achieve separation. An appropriate eluent is used to elute the weakly held metal ions first, then the stronger ones. Table 4 displays the separation eluents employed and the order of elution. The separations are fairly distinct, and it is observed that recovery is precise and repeatable.

Table 5 Separation of binary metal ions systems on PCSM column

It can also be observed from Table 5 that with increasing the separation factor percentage, recovery of metal ions is also increased and vice versa. As per Table 5, the percentage recovery of Cr3+ ion ranged from 93.05 to 98.23%. To clearly perceive the behavior of eluting solvent and the amount found after each 10 mL of solvent, we have plotted the volume of 0.01 M EDTA (mL) against the volume of effluent (mL) as shown in Fig. 8. These figures show that the volume of 0.01 M EDTA peaks around 20–30 mL volume of effluent and then gradually decreased.

Fig. 8
figure 8

Chromatograms demonstrating binary separations of metal ions on a PCSM nanocomposite ion exchanger column using different eluents

Apart from the metal ion removal or separation, the synthesized PCSM composite can also be used for antibacterial applications such as the removal of harmful bacteria that normally live in our bodies. One of the common examples of such bacteria is Escherichia coli which can be associated with several medical problems like food poisoning, diarrhea, pneumonia, or urinary tract infections. Hence, we have studied the antibacterial properties of PCSM composite against Escherichia coli microorganisms using the optical density technique. Figure 9 displays the growth curves of Escherichia coli without PCSM (that is designated as negative control) and with various concentrations (50 μg/mL and 100 μg/mL) of PCSM. Herein also, ion exchanger was found to be an effective antibacterial agent at different concentration levels. The antibacterial property is increased with the increment in the ion exchanger’s concentration. It can also be found from Fig. 9 that 100 μg/mL concentration of PCSM decreases the growth rate of bacteria after the incubation of 5 h. One of the possible reasons for the reduction in bacterial growth can be the induction of a relatively prolonged lag phase in the presence of PCSM composite. Hence, PCSM can be effective in the removal of Escherichia coli from waterways.

Fig. 9
figure 9

Growth curve of Escherichia coli in the presence of PCSM nanocomposite ion exchanger

Conclusion

In this work, a novel nanocomposite ion exchanger was synthesized by precipitation technique using pectin and CSM. The prepared PCSM nanocomposite was characterized and tested for separating heavy metals and eliminating bacterial pollutants from water systems. FTIR results confirmed the association of pectin with CSM and the crystallinity index measurements by XRD characterization revealed the semi-crystalline nature of PCSM. SEM and TEM examinations indicated that PCSM morphology was completely different from that of CSM due to bounding of pectin organic polymer to CSM and its particles were in the nanoscale range at least in two dimensions, respectively. As for metal separation, PCSM exhibited high selectivity toward Cr3+ ions and also antibacterial activity against Gram-negative bacteria Escherichia coli.