Abstract
Because positron emission tomography (PET) provides biochemical information in vivo with the sensitivity at the sub-pico-molar level, pre-clinical research using PET plays an important role in biological and pharmaceutical sciences. However, small animal imaging by PET has been challenging with respect to spatial resolution and sensitivity due to the small volume of the imaging objects. A DOI-encoding technique allows for pre-clinical PET to simultaneously achieve high spatial resolution and high sensitivity. Thus many DOI-encoding methods have been proposed. In this paper we describe why DOI measurements are important, what is required in DOI-encoding designs, and how to extract DOI information in scintillator-based DOI detectors. Recently, there has been a growing interest in DOI measurements for TOF PET detectors to correct time walk as a function of DOI position. Thus, the DOI-encoding method with a high time performance suitable for TOF detectors is now required. The requirements to improve the time resolution in DOI detectors are discussed as well.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
Price P. PET as a potential tool for imaging molecular mechanisms of oncology in man. Trends Mol Med. 2001; 7(10):442–426.
Jagoda EM, Vaquero JJ, Seidel J, Green MV, Eckelman WC. Experiment assessment of mass effects in the rat: implications for small animal PET imaging. Nucl Med Biol. 2004; 31(6):771–779.
Derenzo SE, Moses WW, Jackson HG, Turko BT, Cahoon JL, Geyer AB, Vuletich T. Initial characterization of a positionsensitive photodiode/BGO detector for PET. IEEE T Nucl Sci. 1989; 36(1):1084–1089.
Moses WW. Trends in PET imaging. Nucl Instrum Meth A. 2001; 471:209–214.
Kim JS, Lee JS, Im KC, Kim SJ, Kim SY, Lee DS, Moon DH. Performance measurement of the microPET Focus 120 scanner. J Nucl Med. 2007; 48(9):1527–1535.
Visser EP, Disselhorst JA, Brom M, Laverman P, Gotthardt M, Oyen WJ, Boerman OC. Spatial resolution and sensitivity of the Inveon small-animal PET scanner. J Nucl Med. 2009; 50(1):139–147.
MacDonald LR, Dahlbom M. Parallax correction in PET using depth of interaction information. IEEE T Nucl Sci. 1998; 45(4):2232–2237.
Lee JS. Technical advances in current PET and hybrid imaging systems. Open Nucl Med J. 2010; 2:192–208.
Shibuya K, Nishikido F, Inadama N, Yoshida E, Chihfung Lam, Tsuda T, Yamaya T, Murayama H. Timing resolution improved by DOI information in an LYSO TOF-PET detector. Conf Rec IEEE NSS MIC. 2007; M19–M17.
Spanoudaki VCh, Levin CS. Investigating the temporal resolution limits of scintillation detection from pixelated elements: comparison between experiment and simulation. Phys Med Biol. 2011; 56(3):735–756.
Surti S, Karp JS. Design considerations for a limited angle, dedicated breast, TOF PET scanner. Phys Med Biol. 2008; 53(11):2911–2921.
Lewellen TK. Recent developments in PET detector technology. Phys Med Biol. 2008; 53:R287–R317.
Liu S, Li H, Zhang Y, Ramirez RA, Baghaei H, An S, Wang C, Liu J, Wong WH. Monte Carlo simulation study on the time resolution of a PMT-quadrant-sharing LSO detector block for time-of-flight PET. IEEE T Nucl Sci. 2009; 56(5):2614–2620.
Moses WW, Derenzo SE. Prospects for time-of-flight PET using LSO scintillator. IEEE T Nucl Sci. 1999; 46(3):474–477.
Moses WW. Recent advances and future advances in time-offlight PET. Nucl Instrum Meth A. 2007; 580(2):919–924.
Xiaobuang Y. A study of light collection efficiency in scintillation detectors. Nucl Instrum Meth A. 1984; 228(1):101–104.
Aykac M, Bauer F, Williams CW, Loope M, Schmand M. Recent timing performance of Hi-Rez detector for time-of-flight (TOF) PET. IEEE T Nucl Sci. 2008; 53(3):1084–1089.
Moisan C, Vozza D, Loope M. Simulating the performances of an LSO based position encoding detector for PET. IEEE T Nucl Sci. 1997; 44(6):2450–2458.
Moszynski M, Kapusta M, Nassalski A, Szczesniak T, Wolski D, Eriksson L, Melcher CL. New prospects for time-of-flight PET with LSO scintillator. IEEE T Nucl Sci. 2006; 53(5):2484–2488.
Hong SJ, Song IC, Ito M, Kwon SI, Lee GS, Sim KS, Park KS, Rhee JT, Lee JS. An investigation into the use of Geiger-mode solide-state photomultipliers for simultaneous PET and MRI acquisition. IEEE T Nucl Sci. 2008; 55(3):882–888.
Lee JS, Hong SJ. Geiger-mode avalanche photodiodes for PET/MRI. In: Iniewski K, editor. Electronic circuits for radiation detection. Boca Raton: CRC Press LLC; 2010. pp. 179–200.
Kwon SI, Lee JS, Yoon HS, Ito M, Ko GB, Choi JY, Lee SH, Chan Song I, Jeong JM, Lee DS, Hong SJ. Development of small-animal PET prototype using silicon photomultiplier (SiPM): initial results of phantom and animal imaging studies. J Nucl Med. 2011; 52(4):572–579.
Karp JS, Daube-Withespoon ME. Depth-of-interaction determination in NaI(TI) and BGO scintillation crystals using a temperature gradient. Nucl Instrum Meth A. 1987; 260:509–517.
Jung JH, Choi Y, Chung YH, Devroede O, Krieguer M. Bruyndonckx P, Tavernier S. Optimization of LSO/LuYAP phoswich detector for small animal PET. Nucl Instrum Meth A. 2007; 571:669–675.
Seidel J, Vaquero JJ, Siegel S, Gandler WR, Green MV. Depth identification accuracy of a three layer phoswich PET detector module. IEEE T Nucl Sci. 1999; 46(3):485–490.
Chandrikamohan P, DeVol TA. Comparison of pulse shape discrimination methods for phoswich and CsI:Tl detectors. IEEE T Nucl Sci. 2007; 54(2):398–403.
Du H, Yang Y, Glodo J, Wu Y, Shah K, Cherry SR. Continuous depth-of-interaction encoding using phosphor-coated scintillators. Phys Med Biol. 2009; 54(6):1757–1771.
Streun M, Brandenburg G, Larue H, Saleh H, Zimmermann E, Ziemons K, Halling H. Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET. IEEE T Nucl Sci. 2003; 50(3):344–347.
Liu H, Omura T, Watanabe M, Yamashita T. Development of a depth of interaction detector for gamma-rays. Nucl Instrum Meth A. 2001; 459:182–190.
Zhang N, Thompson CJ, Togane D, Cayouette F, Nguyen KQ. Anode position and last dynode timing circuits for dual-layer BGO scintillator with PS-PMT based modular PET detectors. IEEE T Nucl Sci. 2002; 49(5):2203–2207.
Hong SJ, Kwon SI, Ito M, Lee GS, Sim KS, Park KS, Rhee JT, Lee JS. Concept verification of three-layer DOI detectors for animal PET. IEEE T Nucl Sci. 2008; 55(3):912–917.
Ito M, Lee JS, Kwon SI, Lee GS, Hong B, Lee KS, Sim KS, Lee SJ, Rhee JT, Hong SJ. A four-layer DOI detector with a relative offset for use in an animal PET system. IEEE T Nucl Sci. 2010; 57(3):976–982.
Chung YH, Hwang JH, Baek C-H, Lee S-J, Ito M, Lee JS, Hong SJ. Monte Carlo simulation of a four-layer DOI detector with relative offset in animal PET. Nucl Instrum Meth A. 2011; 626- 7:43–50.
Ito M, Hong SJ, Lee JS, Kwon SI, Lee GS, Park KS, Hong B, Lee KS, Lee SJ, Rhee JT, Sim KS. Four-layer DOI detector with a relative offset in animal PET system. Conf Rec IEEE NSS MIC. 2007; M26-76.
Murayama H, Ishibashi I, Uchida H, Omura T, Yamashita T. Depth encoding multicrystal detectors for PET. IEEE T Nucl Sci. 1998; 45(3):1152–1158.
Tsuda T, Murayama H, Kitamura K, Yamaya T, Yoshida E, Omura T, Kawai H, Inadama N, Orita N. A four-layer depth of interaction detector block for small animal PET. IEEE T Nucl Sci. 2004; 51(5):2537–2542.
Inadama N, Murayama H, Hamamoto M, Tsuda T, Ono Y, Yamaya T, Yoshida E, Shibuya K, Nishikido F. 8-layer DOI encoding of 3-dimensional crystal array. Conf Rec IEEE NSS MIC. 2005; J01-5.
Inadama N, Murayama H, Yamaya T, Nishikido F, Shibuya K, Yoshida E, Tsuda T, Ohmura A, Yazaki Y, Osada H. DOI PET detectors with scintillation crystals cut as triangular prisms. Conf Rec IEEE NSS MIC. 2008; M06-201.
Rafecas M, Boning G, Pichler BJ, Lorenz E, Schwaiger M, Ziegler SI. A Monte Carlo study of high-resolution PET with Granulated dual-layer detectors. IEEE T Nucl Sci. 2001; 48(4):1490–1495.
McElroy DP, Hoose M, Pimpl W, Spanoudaki V, Schüler T, Ziegler SI. A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout. Phys Med Biol. 2005; 50(14):3323–3335.
Levin CS. Design of a high-resolution and high-sensitivity scintillation crystal array for PET with nearly complete light collection. IEEE T Nucl Sci. 2000; 49(5):2236–2243.
Vandenbroucke A, Foudray AM, Olcott PD, Levin CS. Performance characterization of a new high resolution PET scintillation detector. Phys Med Biol. 2010; 55(19):5895–5911.
Braem A, Chesi E, Joram C, Séguinot J, Weilhammer P, De Leo R, Nappi E, Lustermann W, Schinzel D, Johnson I, Renker D, Albrecht S. High precision axial coordinate readout for an axial 3-D PET detector module using a wavelength shifter strip matrix. Nucl Instrum Meth A. 2007; 580(3):1513–1521.
Beltrame P, Bolle E, Braem A, Casella C, Chesi E, Clinthorne N, Cochran E, De Leo R, Dissertori G, Djambazov G, Fanti V, Honscheid K, Huh S, Johnson I, Joram C, Kagan H, Lustermann W, Meddi F, Nappi E, Nessi-Tedaldi F, Oliver JF, Pauss P, Rafecas M, Renker D, Rudge A, Schinzel D, Schneider T, Seguinot J, Smith S, Solevi P, Stapnes S, Weilhammer P. Construction and tests of demonstrator modules for a 3-D axial PET system for brain or small animal imaging. Nucl Instrum Meth A. [In press].
Shimizu K, Ohmura T, Watanabe M, Uchida H, Yamashita T. Development of 3-D detector system for positron CT. IEEE T Nucl Sci. 1988; 35(1):717–721.
Shao Y, Silverman RW, Farrell R, Cirignano L, Grazioso R, Shah KS, Vissel G, Clajus M, Tumer TO, Cherry SR. Design studies of a high resolution PET detector using APD arrays. IEEE T Nucl Sci. 2000; 47(3):1051–1057.
Yang Y, Dokhale PA, Silverman RW, Shah KS, McClish MA, Farrell R, Entine G, Cherry SR. Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodes. Phys Med Biol. 2006; 51(9):2131–2142.
Abreu MC, Aguiar JD, Almeida FG, Almeida P, Bento P, Carrico B, Ferreira M, Ferreira NC, Goncalves F, Leong C, Lopes F, Lousa P, Martins MV, Matela N, Mendes PR, Moura R, Nobre J, Oliveira N, Ortigao C, Peralta L, Pereira R, Rego J, Ribeiro R, Rodrigues P, Sampaio J, Santos AI, Silva L, Silva JC, Sousa P, Teixeira IC, Teixeira JP, Trindade A, Varela J. Design and evaluation of the Clear-PEM scanner for positron emission mammography. IEEE T Nucl Sci. 2006; 53(1):71–77.
Shao Y, Li H, Gao K. Initial experimental studies of using solidstate photomultiplier for PET applications. Nucl Instrum Meth A. 2007; 580(2):944–950.
Yang Y, Wu Y, Qi J, James SS, Du H, Dokhale PA, Shah KS, Farrell R, Cherry SR. A prototype PET scanner with DOIencoding detectors. J Nucl Med. 2008; 49(7):1132–1140.
Worstell W, Adler S, Domigan P, Johnson O, Kudrolli H, Lazuka D, Monteverde P, Nevin J, Rohatgi R, Romanov L, Starsja S. Design and performance of a prototype whole-body PET/CT scanner with fiber optic readout. Conf Rec IEEE NSS MIC. 2004; 3280–3284.
Du H, Yang Y, Cherry SR. Measurements of wavelength shifting (WLS) fibre readout for a highly multiplexed, depthencoding PET detector. Phys Med Biol. 2007; 52(9):2499–2514.
Lewellen TK. The challenge of detector designs for PET. AJR Am J Roentgenol. 2010; 195(2):301–309.
Cherry SR, Shao Y, Tornai MP, Siegel S, Ricci AR, Phelps ME. Collection of scintillation light from small BGO crystals. IEEE T Nucl Sci. 1995; 42(4):1058–1063.
Joung J, Miyaoka RS, Lewellen TK. cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme. Nucl Instrum Meth A. 2002; 489(1–3):584–598.
Ling T, Lewellen TK, Miyaoka RS. Depth of interaction decoding of a continuous crystal detector module. Phys Med Biol. 2007; 52(8):2213–2228.
van der Laan DJ, Maas MC, Schaart DR, Bruyndonckx P, Lamaitre C, van Eijk CWE. Spatial resolution in positionsensitive monolithic scintillation detectors. Conf Rec IEEE NSS MIC. 2006; 2506–2510.
Bruyndonckx P, Leonard S, Liu J, Tavernier S, Szupryczynski P, Fedorov A. Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes. IEEE T Nucl Sci. 2003; 50(5):1415–1419.
Maas MC, van der Laan DJ, Schaart DR, Huizenga J, Brouwer JC, Bruyndonckx P, Leonard S, Lemaitre C, van Eijk CWE. Experimental characterization of monolithic-crystal small animal PET detectors read out by APD arrays. IEEE T Nucl Sci. 2006; 53(3):1071–1077.
Bruyndonckx P, Lemaître C, Schaart D, Maas M, van der Laan DJ, Krieguer M, Devroede O, Tavernier S. Towards a continuous crystal APD-based PET detector design. Nucl Instrum Meth A. 2007; 571(1–2):182–186.
Schaart DR, van Dam HT, Seifert S, Vinke R, Dendooven P, Löhner H, Beekman FJ. A novel, SiPM-array-based, monolithic scintillator detector for PET. Phys Med Biol. 2009; 54(11):3501–3512.
Vinke R, Löhner H, Schaart DR, van Dam HT, Seifert S, Beekman FJ, Dendooven P. Time walk correction for TOF-PET detectors based on a monolithic scintillation crystal coupled to a photosensor array. Nucl Instrum Meth A. 2010; 621(1–3):595–604.
Chung YH, Lee S-J, Beak C-H, Choi Y. New design of a quasimonolithic detector module with DOI capability for small animal PET. Nucl Instrum Meth A. 2008; 593(3):588–591.
Lee S-J, Baek C-H, Hwang JY, Choi Y, Chung YH. Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET. Nucl Instrum Meth A. 2010; 621:590–594.
Lee S-J, Baek C-H, Chung YH, Choi Y. A cross-stack quasimonolithic detector with DOI capability for a small animal PET. Conf Rec IEEE NSS MIC, 2008; M06–M81.
Miyaoka RS, Lewellen TK. Design of a depth of interaction (DOI) PET detector module. IEEE T Nucl Sci. 1998; 45(4):1069–1073.
Lewellen TK, Janes M, Miyaoka RS. DMice-a depth-ofinteraction detector design for PET scanners. Conf Rec IEEE NSS MIC. 2002; 2288-92.
Champley KM, Lewellen TK, MacDonald LR, Miyaoka RS, Kinahan PE. Statistical three-dimensional positioning algorithm for high-resolution dMiCE PET detector. Conf Rec IEEE NSS MIC. 2008; 4751–4754.
Yang Y, Wu Y, Cherry SR. Investigation of depth of interaction encoding for a pixelated LSO array with a single multi-channel PMT. IEEE T Nucl Sci. 2009; 56(5):2594–2599.
Ito M, Lee JS, Park MJ, Sim KS, Hong SJ. Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a singleended readout by a multi-anode PMT. Phys Med Biol. 2010; 55(13):3827–3841.
Haneishi H, Sato M, Inadama N, Murayama H. Simplified simulation of four-layer depth of interaction detector for PET. Radiol Phys Technol. 2008; 1(1):106–114.
Cho ZH, Juh SC. Resolution and sensitivity improvement in positron emission tomography by the first interaction point determination. Conf Rec IEEE NSS MIC. 1991; 1623-7.
Comanor KA, Virador PRG, Moses WW. Algorithms to identify detector Compton scatter in PET modules. IEEE T Nucl Sci. 1996; 43(4):2213–2219.
Miyaoka RS, Lewellen TK. Effect of detector scatter on the decoding accuracy of a DOI detector. IEEE T Nucl Sci. 2000; 47(4):1614–1619.
Park S-J, Rogers WL, Clinthorne NH. Effect of inter-crystal Compton scatter on efficiency and image noise in small animal PET module. Conf Rec IEEE NSS MIC. 2003; M3–M115.
Lashkari S, Sarkar S, Ay MR, Rahmim A. The influence of crystal material on intercrystal scattering and the parallax effect in PET block detectors: A Monte Carlo study. IFMBE Proc. 2008; 21(8):633–636.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ito, M., Hong, S.J. & Lee, J.S. Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capability. Biomed. Eng. Lett. 1, 70–81 (2011). https://doi.org/10.1007/s13534-011-0019-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13534-011-0019-6