Abstract
This paper presents a novel piezo driven motion stage employing multiple motion levers allowing for an amplification ratio that exceeds 60x enabled by a newly contrived cross hinge structure. Optimization of the motion stage was performed and simulation results proved the superiority of the newly devised cross hinge compared to the conventional flexure hinge. Measurements of the motion stage were made using an optical microscope. The motion stage was incorporated into a visually served close loop motion control scheme and experimental results prove that the feedback system is capable of 20 nm nano-stepping.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Scire, F. E. and Teague, E. C., “Piezodriven 50-μm Range Stage with Subnanometer Resolution,” Review of Scientific Instruments, Vol. 49, No. 12, pp. 1735–1740, 1978.
Choi, S. B., Han, S. S., and Lee, Y. S., “Fine Motion Control of a Moving Stage using a Piezoactuator Associated with a Displacement Amplifier,” Smart Materials and Structures, Vol. 14, No. 1, pp. 222–230, 2005.
Kang, B. H., Ting-Yung Wen, J., Dagalakis, N. G., and Gorman, J. J., “Analysis and Design of Parallel Mechanisms with Flexure Joints,” IEEE Transactions on Robotics, Vol. 21, No. 6, pp. 1179–1185, 2005.
Gao, P., Swei, S.-M., and Yuan, Z., “A New Piezodriven Precision Micropositioning Stage Utilizing Flexure Hinges,” Nanotechnology, Vol. 10, No. 4, pp. 394–398, 1999.
Lu, T. F., Handley, D. C., Yong, Y. K., and Eales, C., “A Three-Dof Compliant Micromotion Stage with Flexure Hinges,” Industrial Robot: An International Journal, Vol. 31, No. 4, pp. 355–361, 2004.
Ryu, J. W., Gweon, D.-G., and Moon, K. S., “Optimal Design of a Flexure Hinge based XYφ Wafer Stage,” Precision Engineering, Vol. 21, No. 1, pp. 18–28, 1997.
Hu, K., Kim, J. H., Schmiedeler, J., and Menq, C. H., “Design, Implementation, and Control of a Six-Axis Compliant Stage,” Review of Scientific Instruments, Vol. 79, No. 2, Paper No. 025105, 2008.
Jae, W. S., “A Study on the Displacement Magnification Mechanism of Ultraprecision stage Using Linear Lever,” M.Sc. Thesis, Department of Mechanical Engineering, Dong Eui University, 2008.
Hwang, E. J., Min, K. S., Song, S. H., Ahn, I. H., and Choi, W. C., “Optimal Design of a Flexure-Hinge Precision Stage with a Lever,” Journal of Mechanical Science and Technology, Vol. 21, No. 4, pp. 616–623, 2007.
Hwang, D. H., Park, J. H., Jeong, J. W., Lee, M. G., “Optima Design of a Flexure Guided Stage with Piezo Electric Transducers,” Proc. of KSPE Spring Conference, pp. 397–398, 2008.
Kim, J. Y., Kwac, L. K., Han, J. H., Kim, H. W., and Shimokohbe, A., “A Study on the Optimal Structural Design using FEM for Micro Stage,” J. Korean Soc. Precis. Eng., Vol. 19, No. 10, pp. 60–65, 2002.
Choi, K. B., Lee, J. J., Kim, M. Y., and Ko, K. W., “Analysis of a Rotation Stage with Cartwheel-Type Flexure Hinges Driven by a Stack-Type Piezoelectric Element,” J. Korean Soc. Precis. Eng., Vol. 24, No. 12, pp. 1225–9071, 2007.
Shin, D. I., Kim, Y. S., Shu, S. W., Han, C., Choi, D. S., and Whang, K. H., “Development of 3-DOF Parallel Manipulator Using Flexure Hinge,” J. Korean Soc. Precis. Eng., Vol. 26, No. 7, pp. 127–133, 2009.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jung, H.J., Kim, J.H. Novel piezo driven motion amplified stage. Int. J. Precis. Eng. Manuf. 15, 2141–2147 (2014). https://doi.org/10.1007/s12541-014-0574-8
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12541-014-0574-8