Introduction

The long-held tenet in TKA of restoration of a neutral overall mechanical axis (OMA) is supported by numerous biomechanical [28], finite element [2, 44], and clinical studies [5, 17, 27, 35, 47, 48, 52, 70, 84], both historical and contemporary, demonstrating increased strain, higher failure rates, and, in many cases, lower functional scores with coronal malalignment. Recently, three-dimensional imaging and custom manufacturing have enabled the development of patient-specific positioning guides (PSPGs). Designed primarily to improve alignment accuracy and precision, PSPG technology harnesses the power of computer templating yet promotes greater surgical simplicity by eliminating the intraoperative presence of the computer.

Unlike manual instrumentation (MI) with intramedullary and extramedullary alignment rods, PSPG technology uses preoperative MRI or CT to design custom shape-fitting jigs (Fig. 1) that conform to the articular surface of the proximal tibia and distal femur to facilitate pin placement for traditional cutting blocks. Some designs incorporate cutting slots into the guide.

Fig. 1 A–B
figure 1

The photograph displays the PSPG and its use intraoperatively to facilitate accurate pin placement on the (A) femur and (B) tibia for standard cutting blocks.

Even in the hands of experienced surgeons, MI results in overall coronal malalignment (> 3° from neutral) in approximately 28% of patients (Table 1). Although computer-assisted navigation (CAN) reduces the number of outliers by approximately threefold (Table 1), it requires additional operative time compared to MI [11] and may increase the rate of complications, such as postoperative stress fracture [10, 55]. PSPGs purportedly eliminate many of the disadvantages of CAN, including surgical prolongation and fiducial pin complications [33, 81], while enabling individualized bone resections that match the measured mechanical axis.

Table 1 Percent of coronal alignment outliers in conventional (manual) instrumentation and computer navigation in prior studies

Limited, and sometimes conflicting, data exist regarding a related PSPG technology that sets alignment based on criteria different from the mechanical axis of the lower limb [33, 42, 81]. More recent PSPG systems rely on the principle of classic cuts and neutrally aligning each component to its respective mechanical axis. A paired cadaveric study performed by one coauthor (AVL) using postoperative supine CT for analysis demonstrated no outliers for tibial component alignment and 11% (one of nine) versus 33% (three of nine) outliers for the femoral component comparing PSPGs to MI [45, 46].

We examined the relative effectiveness of PSPGs and MI in achieving neutral mechanical axis alignment of the lower extremity and of the femoral and tibial components.

Patients and Methods

Between January 2009 and December 2010, one of the authors (AVL) performed primary TKA in 310 patients using PSPGs (Signature™ Personalized Patient Care System; Biomet Inc, Warsaw, IN) and 875 patients using MI (extramedullary tibial and intramedullary femoral jigs). In addition, another author (JHD) performed primary TKA using PSPGs and MI in 507 and 872 patients, respectively, between June 2008 and December 2009. We considered all patients who had disabling knee arthritis, were at an acceptable medical risk, and failed nonoperative management to be candidates for TKA and evaluated them for applicability of PSPGs. The indications for PSPGs were (1) the ability and willingness to undergo preoperative MRI, (2) the willingness to wait 4 to 6 weeks before surgery, and (3) the acceptance of the relatively new technology. Exclusion criteria for PSPGs were (1) metallic hardware within 10 cm of the knee or prior THA and (2) a prior MRI performed by their primary care physician. At the time of the study, the currently available CT option for preoperative imaging in patients with metallic hardware was not ready. An MRI performed by an outside physician typically was not adequate for PSPG technology since it did not include the knee or hip, and a repeat MRI was not performed. Patients who did not fit the PSPG criteria underwent TKA with MI. The capability for standing AP long-leg radiographs (LLRs) was acquired in January 2010, and the first 105 PSPG patients (January 2010 to December 2010) and 55 MI patients (February 2010 to September 2010) who returned for followup were imaged and included for retrospective analysis. For surgeon JHD, the capability had been established for longer. LLRs from 464 PSPG TKAs (June 2008 to December 2009) and from 100 consecutive MI TKAs (March 2008 to May 2008) were included. We excluded patients with lower limb fractures after TKA or poor-quality LLRs. Both groups were highly representative of each surgeon’s overall patient population. Proceedings were in accordance with the Western Institutional Review Board (Olympia, WA), Protocol Number 20041825, Study Number 1063398.

The surgeons used the PSPG system according to the manufacturer’s instructions. A preoperative MRI was performed and the data sent to Biomet, Inc, which forwarded it to Materialise (Leuven, Belgium), where it was uploaded onto a proprietary software planner. After the surgeons reviewed the templating and alignment of components in multiple planes and approved the plan, rapid-prototyping computer-assisted design/computer-assisted manufacturing technology created PSPG jigs. After exposure of the knee, we carefully positioned PSPG jigs over the articular surfaces, ensuring an accurate fit. Then, guided by the PSPG jig, we placed drill holes and pins in the periarticular bone, which then determined the orientation of standard cutting guides. We then carried out the remainder of the TKA procedure as usual. In all cases, the PSPG could be used, and in no patient was it necessary to convert from PSPG to MI intraoperatively.

Two independent reviewers evaluated LLRs using digital tools. In all patients, we analyzed the relationship of the center of the knee to the OMA of the lower limb. In the subset of patients for AVL, we recorded the additional following measurements: (1) the angle between the tibial (TMA) and femoral mechanical axis (FMA), (2) the angle between the tibial component and the TMA, (3) the angle between the femoral component and the FMA, and (4) the angle between the femoral anatomic axis (FAA) and the FMA. In addition, we used preoperative standard AP weightbearing films of the knee to estimate original anatomic alignment. Both groups were similar in alignment and amount of flexion contracture (Table 2). We randomly selected 20 LLRs for repeat analysis to assess intra- and interobserver reliability, which demonstrated Pearson correlation coefficients of 0.67 to 0.96 and 0.64 to 0.95, respectively.

Table 2 Summary of preoperative knee measurements*

The center of the femoral head was determined using digital circles. We defined the center of the ankle as the center of the proximal surface of the talar dome and the OMA as a line connecting these two points. The mediolateral width of the tibial tray was divided into three equal zones and the OMA was assessed as to whether it passed medial to, lateral to, or through the central third. We defined the center of the knee as midway across the proximal resected surface of the tibia and determined the FMA and TMA by connecting this point to the center of the femoral head and the center of the ankle, respectively [60]. The position of the femoral component was defined as a line tangent to the distal aspects of the medial and lateral femoral condyles, and the tibial component as a line along the surface of the tibial tray. The FAA was defined as a line connecting the mediolateral midpoint of the femur at the midshaft and at 10 cm proximal to the knee [60].

We deemed neutral alignment to be 90° for the individual components and their respective mechanical axes and 180° for the FMA-TMA or hip-knee-ankle (HKA) angle. We measured all angles on the lateral aspect of the intersecting lines, except the FAA-FMA angle, which we measured as the more acute angle. Angles greater than and less than neutral alignment were deemed varus and valgus, respectively. For the HKA angle and both components, we calculated the mean individual patient error from neutral alignment in addition to the all-patient mean angulation since varus and valgus errors offsetting one another would tend to neutralize the latter. The percent of cases in which the HKA angulation was different from neutral in increments of 1° was calculated (Fig. 2).

Fig. 2
figure 2

The graph demonstrates the range of deviation from neutral alignment for the HKA angle for the PSPG and MI systems.

We integrated the data for AVL and JHD regarding the distance of OMA from the center of the knee. The overall mean angle and mean individual deviation angles for the tibial component, the femoral component, the HKA, and FAA-FMA between PSPGs and MI were analyzed according to a parametric distribution using an unpaired two-tailed Student’s t test. The proportion of outliers and the relationship of the OMA to the center of the knee between PSPG and MI were analyzed using a chi square test.

Results

The OMA passed through the central third of the knee more often (p < 0.001) with PSPG (88%) than MI (78%). The overall mean HKA angle for PSPG (180.6°) was similar (p = 0.17) to MI (181.1°), but there were fewer (p = 0.018) ± 3° HKA angle outliers with PSPG (9%) than MI (22%). The overall mean tibial (89.9° versus 90.4°) and femoral (90.7° versus 91.3°) component angles were closer (p = 0.005, p < 0.001) to neutral with PSPG compared to MI, but the rate of outliers ± 2° was similar (p = 0.21, p = 0.14) for both the tibia (10% versus 7%) and femur (22% versus 18%). The mean FAA-FMA angles were similar in both groups (Table 3).

Table 3 Alignment of TKA

Discussion

PSPG technology for TKA integrates the time-honored principle of mechanical alignment with computer templating and advanced imaging. The majority of literature supports the restoration of a neutral axis as a contributing factor in implant longevity [5, 27, 28, 35, 52, 70]. Intraoperative CAN improves precision and accuracy of alignment compared to MI [54] but is hindered by time-consuming landmark registration, increased operative length, greater cost, risk of pin loosening, and a substantial learning curve [45]. A necessary step in validating the usefulness of any new system such as the PSPG is to establish its equivalence or superiority to existing modalities. We sought to determine its ability to achieve neutral coronal mechanical alignment and compared it to both MI and published reports of CAN.

There are several potential limitations of this study. First, coronal alignment and standing LLRs are the traditional gold standard for assessment of TKA [60]. However, with the recent widespread introduction of three-dimensional imaging and CAN, there is additional focus on sagittal and axial alignment [19, 30, 77, 88]. While postoperative CT is routinely acquired to evaluate component rotation in patients with patellar maltracking issues [6], the costly nature of routine postoperative scanning is prohibitive in large-scale studies. Although sagittal alignment is undoubtedly important in TKA as well, parameters of ideal orientation have been studied far less than in the coronal or axial planes [77]. Second, several recent studies challenged the premise of a coronal safe zone and associated durability. Parratte et al. [67] found mechanical alignment in 292 TKAs did not confer a significant advantage compared to malalignment (± 3°) in 106 cases in terms of survival. In a smaller study, Matziolis et al. [57] reported no difference in patient outcome between aligned TKA and a subset of varus outliers and no revisions in either group. Nevertheless, their findings implied not that coronal alignment was unimportant but rather that assessment of alignment as a dichotomous variable (aligned versus malaligned) was limited and could only serve as a general guideline. Additionally, there was no substantial evidence that any target other than neutral would lead to better results. Likely, the benefits of improved coronal alignment lie along a gradient, and other factors, such as soft tissue balance, if not optimized as well, can overshadow subtle perfections in alignment. Third, reimbursement schematics for TKA have become more parsimonious, and surgeons are challenged with balancing limited financial resources and the near-infinite potential for technologic advancement. The initial capital cost for CAN is approximately $150,000 to $300,000 and, for an even newer technology, robotics, is up to $800,000 [83]. A conservative estimate per procedure for CAN is $1500 [62]. As the number of TKAs performed in the hospital decreases, the expense of CAN substantially increases [62]. Because low- to intermediate-volume surgeons and hospitals perform a sizable proportion of TKAs [38, 79], the PSPG may offer a viable alternative to CAN since it does not incur a substantial initial investment. The costs of a preoperative MRI and a PSPG jig vary considerably by geographic location, and revenue generated by the MRI may offset the expense of PSPGs. While a cost-effective analysis of PSPGs is beyond the scope of this study, the potential savings from reduced instrument tray processing and implant inventory may offset a portion of the added expenses. Furthermore, the actual patient benefit of any technology directly correlates to the surgeon’s proficiency with MI and ability to achieve desired technical outcomes without additional tools. In this study, high-volume surgeons with extensive experience with both PSPGs and MI performed the TKAs. As with any instrumentation system, there is a learning curve with PSPGs, and whether less experienced surgeons are able to integrate its unfamiliar yet intuitive skill set into their armamentarium remains to be seen. Fourth, the objective of this study was not to examine parameters such as patient satisfaction, early functional scores, or length of hospitalization, but there was evidence that improved alignment was associated with better function and quality of life [17, 24, 47]. Indeed, the benchmark of new techniques and technology is not merely achieving a statistically significant difference but also producing a clinically important and tangible improvement in patient outcome. However, demonstrating these effects often requires lengthy followup. With the proliferation of PSPGs by multiple major manufacturers and its popularity among surgeons for several years, published validation of its performance is due. The extent of acceptance of this technology in principle is likely a reflection of not only its compatibility with existing TKA principles but also the recognition of a promising segue between the surgeon and the computer.

We found the use of PSPGs reduced the percentage of HKA outliers at rates superior to many previously reported CAN and nearly all MI rates including the coauthor’s own (Table 1). Outliers for the tibial and femoral component in this study for both PSPG (10%, 22%) and MI (7%, 18%) were lower than those in a meta-analysis for MI (20%, 34%) but higher than those using CAN (5%, 10%) [54]. The mean postoperative FAA-FMA angles for both PSPG and MI fell within the 5° to 7° range typically assumed for TKA performed using intramedullary guides and without preoperative LLRs [22, 25]. Further studies are necessary to examine the effect of compensatory or compounding effects of individual component malalignment on the overall lower limb alignment and on implant function.

While accurate and precise alignment guides are important tools in restoring the proper overall mechanical axis, they are not a substitute for careful preoperative planning, good clinical and intraoperative judgment, appropriate soft tissue balancing, and precise implantation technique. Indeed, there are many variables that affect TKA performance and patient satisfaction, and static coronal alignment is only one measure of technical success by the surgeon. Nevertheless, it is a cornerstone of TKA and carries a weighty import that is backed by an abundance of data. In concert with existing literature, the findings reported here demonstrate the PSPG is effective in achieving overall coronal alignment with accuracy and precision better than MI and, in select regard, comparable to CAN.