Introduction

Hip dislocation is a frequent mode of failure of THA with 0.5% to 10% dislocation rates reported for primary THA [3] and 10% to 25% after revision surgery [1]. The dislocation risk is multifactorial. In addition to infection, wear, issues with the quality of the surrounding soft tissue, and the type of prosthesis, the position of the implants plays a major role in the mechanical stability of a THA [5, 7, 10, 16, 19, 23, 25, 29, 30, 33]. The CT scan is the current gold standard for assessing the position of the implants in case of dislocation. Reference values with the common protocol have been reported for native hips [2, 15, 35, 37] and those with THAs [9, 20, 32, 36, 39].

However, the CT scan is done with the patient in the supine position, whereas the sitting position is where most posterior dislocations occur [12, 34]. Therefore, knowing the acetabular version in that position might be important, and measuring cup version of the patient in the supine position on a CT scan for hip dislocation, as most clinicians do, could result in misleading information as apparent acetabular anteversion increases 1° for every 2°-increase of pelvic tilt [18, 23, 25, 38].

Using an earlier protocol to adjust the plane of the CT scan to the subject’s sacral slope in standing and sitting positions, the AAA was obtained in simulated standing and sitting positions [22]. The measured value substantially changed from one position to the other with changes in lumbar spine lordosis and pelvic tilt.

We therefore compared measured acetabular cup orientations on axial CT scans taken with the patient in a supine position with those on CT sections at angles to the sacral slope reflecting standing and sitting positions.

Materials and Methods

We retrospectively reviewed the images of 328 selected asymptomatic patients who had undergone THAs. All patients had noncemented THAs with metal-backed acetabular implants and followups of 1 to 11 years (average, 4.3 years). Forty-eight percent were men and 52% were women. Their ages ranged from 60 to 79 years (average, 70.4 years). All patients had AP and lateral radiographs of the pelvis in the standing and sitting positions and a conventional low-dose CT scan of the pelvis in a supine position. Patients were checked for the absence of lower limb length differences and lumbosacral junction abnormalities (fusion, malformation, severe disc degeneration with substantial osteophytes, and disc space narrowing).

All measurements were made by two independent observers (JYL, MG). The abduction angle (AA) was measured on the AP view. On the lateral view, the sacral slope (SS) and acetabular sagittal inclination (ASI) were measured. The SS angle is formed by the tangent line to the upper end plate of S1 and the horizontal plane [24]. As a result of basic trigonometric relationships in three dimensions, the ASI has the same value as the operative anteversion, described by Murray [26], while being a different angle. The SS, AA, and ASI were measured with patients in the standing, sitting, and supine positions (Fig. 1). The standard radiographs were used for standing and sitting positions and CT topograms were used for the supine position.

Fig. 1A–D
figure 1

(A) AP and (B) lateral radiographs of a patient in a standing position, and (C) AP and (D) lateral radiographs of the same patient in the sitting position are shown. Measurement of the abduction angle (AA) on the AP radiograph and the acetabular sagittal inclination (ASI) and sacral slope (SS) is shown. Variations in orientation of the acetabular cup in the standing versus the sitting position can be seen.

In addition, the pelvic incidence (inclination) was measured on the lateral radiographs. The pelvic incidence is the angle between the line perpendicular to the S1 end plate and the line connecting the middle of the sacral plateau to the center of the femoral head. This parameter is related to the size of the pelvis in the sagittal plane and the offset between the lumbosacral junction and the hips [6]. As a morphometric parameter of bony structure, the pelvic incidence does not vary with the position of the pelvis (Fig. 2). The average radiation dose for the AP and lateral radiographs was 3 mGy and 4.6 mGy, respectively.

Fig. 2A–B
figure 2

Lateral schematics of the pelvis in (A) standing and (B) sitting positions show variations of the sacral slope (SS) and the acetabular orientation. The SS increases in the standing position, whereas the acetabular sagittal inclination (ASI) angle decreases. The SS decreases in the sitting position and the ASI angle increases. The pelvic incidence (PI) represents the offset between the lumbosacral junction and the hips. The PI is a constant anatomic parameter. It does not vary whatever the pelvic tilt is.

From the CT scan sections, the AAA was measured according to the usual routine protocol, with the patient in a supine position on the axial section, similar to the protocol described by Stem et al. [35] (Fig. 3A). Measurement of the AAA corresponding to standing and sitting positions required an adjustment of the sectional plane following the value of the SS on lateral radiographs with the patients in standing (Fig. 3C) and sitting positions [23] (Fig. 3C). Because the SS is a major parameter for assessing the position of the pelvis in the sagittal plane [31], the SS was used as a reference for the functional position of the pelvis. The radiation dose for the CT scan of the pelvis was 500 mGy · cm, which corresponds to 9.5 mSv using the conversion ratio from Hidajat et al. [13]. The standing AAA measured two times by the two observers showed a paired intraobserver difference of 2.53°. The intraobserver intraclass correlation coefficient (ICC) was 0.951. The paired interobserver difference was 3.25°. The interobserver ICC was 0.916.

Fig. 3A–C
figure 3

(A) The standard CT scan protocol is performed with the patient in a supine position. It provides routine measurement of acetabular anteversion (AAA). (B) The proposed CT scan protocol includes an adjustment to the sacral slope, which replicates the standing position. First, the sacral slope (SS) is measured on the lateral radiograph in a standing position. Second, the sacral slope is transferred to the CT scan scout view (1 = sacral end plate; 2 = horizontal plane in a standing position). (C) Adjustment to the SS when measured on a lateral radiograph in a sitting position is shown. Changes of the measured AAA according to the plane of section can be seen.

The statistical analysis began with a study of the reproducibility and repeatability of measurement of the AAA of the cup of a THA on a CT scan because repeatability data of such measurement were not reported before. We then performed a descriptive analysis of the measured variables (mean ± SD). Normality of the variables was checked using the Shapiro-Wilk test. Paired t-tests were used to investigate differences among standing, sitting, and supine positions for each normally distributed variable. Using the Spearman correlation test, the relationships among the supine, sitting, and standing positions regarding the AAA, AA, and ASI were investigated. Finally, a linear regression analysis aimed at identifying the relevant parameters that influence the gain in AAA from the standing to the sitting position were identified among the pelvic incidence, the standing AAA, AA, ASI, and SS, and the variation. The SPSS 11.5 software package (SPSS Inc, Chicago, IL, USA) was used for the calculations with the significance level of p < 0.05 of the SS between the standing and sitting positions.

Results

The average (SD) pelvic incidence was 53.7° (13.6°); this anatomic parameter does not vary with the position of the pelvis. The SS decreased from the supine to the standing and the sitting positions. The frontal and sagittal inclinations and the anatomic anteversion increased from the supine to the standing and the sitting positions (Table 1).

Table 1 Measured parameters*

Measurement of anatomic anteversion with the CT scan correlated in the standing and supine positions but not between the sitting position and any other positions (Table 2). Similarly, the AA (Table 3) and the ASI (Table 4) correlated in the standing position and the supine position, but not in the sitting and or any other positions. The regression analysis showed a correlation coefficient of r = 0.943 and a coefficient of determination r2 = 0.889. The regression equation was:

$$ (\hbox{sitting AAA} - \hbox{standing AAA}) = -0.385\,(\hbox{sitting SS}-\hbox{standing SS}) -0.254\, \hbox{standing AAA} - 0.196\, \hbox{standing AA} + 0.029\, \hbox{standing ASI} + 0.05\, \hbox{standing SS} + 0.001\, \hbox{PI} + 17.9 + \varepsilon .$$
Table 2 Spearman’s correlation matrix between CT images for AAA*
Table 3 Spearman’s correlation matrix between AP radiographs for AA*
Table 4 Spearman’s correlation matrix between lateral radiographs for ASI*

Only the first three factors of the equation had significant p values. Their standardized coefficients were −0.786, −0.273, and − 0.151, respectively, showing that the gain in AAA from the standing to the sitting position was mostly the result of mobility in the lumbosacral junction.

Discussion

Because posterior dislocations of the hip mostly occur in the sitting position, and some anterior dislocations in the standing position, the rationale of our study was to investigate a novel protocol for measuring AAA on the CT scan with simulating the sitting and standing positions. We therefore compared measured acetabular cup orientations on axial CT scans taken with the patient in a supine position from those on CT sections at angles to the sacral slope reflecting standing and sitting positions.

We acknowledge limitations to our study. First, we studied no patients with dislocations and therefore did not directly assess the importance of the proposed SS-adjusted CT protocol on the diagnosis and understanding of the mechanical dysfunction of unstable THAs. The normal ranges of the AAA, the AA, and the ASI, and the reproducibility of measurement of anatomic anteversion on the CT scan are presented in a large asymptomatic population, but it would be necessary to compare numerous dislocation cases with our data to define a predictive safety zone using the sacral slope-adjusted CT protocol. The safety limits for AAA would be the maximal value of the AAA above which there is a substantial risk of anterior dislocations and the minimum value of the AAA below which there is an increased risk of posterior dislocation. For now, the practical implication of the SS-adjusted CT scan protocol is limited to improving the examination of dislocations. Second, CT scans have substantial cost and radiation dose. However, the proposed protocol is based on only two additional lateral radiographs, which represent a little extra cost and radiation source, that substantially improve the results of the CT scans that already are widely performed in current practice for examining dislocations [17, 28]. It is likely that, in the future, the EOS® imaging system (EOS Imaging SA, Paris, France) could directly and accurately provide the three-dimensional orientation of the acetabulum in various postures with more efficiency and less radiation dose [8].

We confirmed that the AAA, frontal inclination, and sagittal inclination were functional parameters that varied substantially among the standing, sitting, and supine positions. We observed that the acetabular parameters in a supine position highly correlated with those in a standing position but poorly correlated with those in a sitting position. The amount of mobility in the lumbosacral junction accounted most for the variation in the AAA between the standing and sitting positions. The notion of a relationship between AAA and the position of the pelvis was suggested by Anda et al. [2] and Zilber et al. [40] in native hips (Table 5). Variations in the acetabular cup position after THA implantation as a function of the patient’s position were reported previously [22, 23]. The current study confirmed and numerically showed the functional relationship between the SS and the AAA: the SS increases while the AAA decreases from the sitting to standing positions and reciprocally the SS decreases and the AAA increases from the standing to sitting positions.

Table 5 Studies of CT assessment of the AAA according to the position

We found a poor correlation between the supine and sitting AAA. This suggests that the usual CT scan protocol is biased and not fully appropriate for examination of a posterior THA dislocation, which occurs in hip flexion. On the contrary, the strong correlation observed between the supine and standing measurements, which were observed in all the acetabular parameters (AAA, AA, and ASI), suggests that the classic CT assessment of the AAA is still a relevant source of information in cases of anterior THA dislocation and subluxation. Few articles address this issue in the literature. One notices only that the correlation between the supine and standing positions is in agreement with the results presented by Nishihara et al., who reported less than 10° variation in orientation of the pelvis from a standing to a supine position in 90% of cases [27].

Lumbosacral junction mobility was the main parameter influencing the variations of AAA between the standing and sitting positions. The fact that the risk of dislocation increases cumulatively with time [4] and the fact that degenerative phenomena in the aging spine that induce progressive changes in sagittal balance with loss of lumbar lordosis and pelvic extension [11, 14, 31] support the idea of the major role of the function of the lumbosacral junction on function of the hip. In everyday practice, stiffness in the lumbar spine (eg, L5-S1 arthrodesis) is a risk factor for THA subluxation and dislocation resulting from the lack of variation in the AAA from a standing to a sitting position. To the best of our knowledge, this question has not been evaluated in the literature. This is not yet well defined, but our study suggests that taking spinal flexibility into account is important when planning a THA implantation or at least identifying outlier patients who have an abnormal pelvic (ie, acetabular) posture. Dual mobility cups could be specifically indicated for those patients [21].

The classic measurement of AAA on CT scans uniquely taken with patients in the supine position seems insufficient to determine the actual position of the acetabular cup from a functional standpoint. In our opinion, the plain measurement is biased specifically in the case of posterior dislocation, because the supine AAA is poorly correlated with the adjusted AAA of the sitting position of dislocation. Therefore, when a CT scan is indicated for patients undergoing THA with problems of recurrent THA dislocation who need revision arthroplasty, we recommend adjusting the CT sectional plane to the SS that corresponds to the position of interest. This protocol would be more standardized and more efficient for measuring orientation of the acetabular cup than the plain CT scan with the patient in a supine position with a random position of the pelvis on the machine. Based on our observations, we suspect mobility of the lumbosacral junction plays a crucial role in the mechanical function and stability of a THA. Therefore, we also recommend doing dynamic lateral radiographs of the lumbosacral junction in the standing and sitting positions for primary THA in patients who have some abnormal features in their lumbosacral spine, for example, in the elderly population [31].