Abstract
The Cerrejón mine has identified fires in its coal production seams for a few years in its operation. Fires are produced as a result of spontaneous combustion phenomena. Coal spontaneous combustion is a phenomenon that occurs naturally during coal oxidation when exposed to atmospheric conditions, due to erosion processes, geological and mining practices. This phenomenon is a subject of great concern in the world’s coal mines, as it causes environmental problems, generating emissions of polluting gases into the atmosphere and economic losses due to reserve consumption. In this work, we seek to optimize the prevention and extinction processes used by the company. In terms of prevention, the current state was evaluated and alternatives, such as diluted bitumen and brine (combustion inhibitor), cement/slaked lime, fine sand cement, and clinker/slaked lime were developed to avoid ignition. As far as extinction is concerned, an additional methodology for medium magnitude fires was determined, in order to improve extinction times through the use of cooling. It was determined that the bitumen/brine has better adhesion and durability properties in the coal seam. Extinction through reagent cooling is quicker, thus improving the backhoe’s productivity and minimizing costs.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
The mining operation of Cerrejón is carried out in Colombia’s northern region, specifically in the peninsula of the Department of La Guajira, covering an approximate area of 78,000 ha. It is located in a valley delimited by the northeastern foothills of the Sierra Nevada de Santa Marta on the east side, and by the Serrania Del Perijá and the Oca Mount, on the west side. Cerrejón has an approximate annual production of 32 Mtons, and it has identified fires during its operation that produced by the spontaneous combustion phenomenon in some of its explotation layers (Fig. 1). Actions are focused on the sealing of coal seams through the application of asphalt emulsion, also—known as bitumen—to exposed layers with high susceptibility to spontaneous combustion. Bitumen is an aqueous dispersion of asphalt with a mixture of biodegradable cationic and nonionic surfactants, dark brown to black. Removal consists of the construction of a ramp to access the fire and work on the burning coal seam wall. The coal seam is engaged at an angle of 45°, in the opposite direction to the gas emissions, thus avoiding the fall or detachment of hot material and loose rocks, protecting the operator’s integrity until the fire is out. Finally, a temperature in the final wall oscillating between 40 and 60 °C is expected to be found through thermographic cameras or thermal guns.
Spontaneous combustion in coal seams is an issue that occurs in mines around the world. It causes environmental problems due to particulate matter emissions and polluting gases, such as carbon monoxide, carbon dioxide, sulfur dioxide, methane gas, and mercury vapor (Beamish 2015; Beamish et al. 2001; Pone et al. 2007; Timko and Derick 1995; Zhao et al. 2015), which represents an environmental potential and a risk to human health (Finkelman 2004; Melody and Johnston 2015). Most of these gases are a product of the carbon oxidation at high temperatures and other elements that are present in it. This process occurs in nature by oxidation of carbon when it comes into contact with oxygen (Jing et al. 2016; Kim 2011; Wang et al. 2011), when exposed due to geological erosion processes as well as to underground and open pit mining practices (Heffern and Coates 2004; Kuenzer and Stracher 2012; Lu et al. 2015; Scott 1994; Singh 2013). Natural carbon oxidation reaction is feasible under the right conditions, considering that the equilibrium constant (K) is very large and oxygen’s partial pressure is close to zero, which implies from a thermodynamics standpoint the reaction occurs throughout the range of possible temperature to infinity as seen in Fig. 2, allowing the reaction to be governed by chemical kinetics. The latter, accelerates rapidly from self-heating and heat release, resulting in ignition and subsequent propagation in coal seams.
Even though there are few published reports of health problems caused by gas emissions, consequences can be significant (Timko and Derick 1995). In India, for example, a large number of people have been displaced from their homes due to health issues caused by coal fire emissions. Volatile elements such as arsenic, fluorine, mercury, and selenium are usually found in coal deposits. These can or may volatilize and in turn be inhaled or adsorbed on crops, food, livestock, or bio-accumulated in birds and fish, in the presence of fires (Finkelman 2004; Melody and Johnston 2015). In addition to the aforementioned elements, such as selenium, arsenic, lead, tin, bismuth, and fluorine condense, where hot gaseous emissions come into contact with the air within fluids, forming layers that can be leached with rainwater and be wash in local bodies of water providing other potential routes of exposure. Studies have been conducted where different compounds are characterized in coal fires emissions as well as maximum concentrations registered in coal mines, where accumulations of these gases occur, such as CO (> 27,000 parts per million), mercury (> 2100 μg/m3), benzene (> 400 parts per billion), toluene (> 397 parts per billion), and greenhouse gas CO2 (> 17% v/v). It should be noted that the concentration of these gases in open pit coal mines is lower due to the dilution generated in the environment. On a global scale, it has been estimated that CO2 emissions as a result of fires in coal mines varies between 12 and 8200 kg/m2 per year (Carras and Young 1994; Dalverny and Chaiken 1991; Dodamani 2014; Fierro et al. 1999).
Coal spontaneous combustion can be divided into two processes: ignition and propagation (Fig. 3). The ignition process is related to the energy accumulation coal undergoes due to an oxidation reaction and the contribution of some variables, which allow coal to reach the minimum energy required to cause the spark that starts a fire, which is known as activation energy (Nordon et al. 1979; Singh 2014; Singh 2013). Subsequently, propagation begins, which is triggering a series of chemical reactions adding to an intense release of heat (Bustamante Rúa et al. 2018; Huo et al. 2015; Kaymakçi and Didari 2002; Smith et al. 1993). Coal self-combustion occurs in a timely manner in the final walls and abandoned pits in the Cerrejón mine (Cerrejón 2016; Quintero et al. 2009). This implies large-scale environmental problems, significant loss of reserves, instability due to geotechnical affectation, and health issues due to the impact on surrounding communities (Bustamante Rúa et al. 2018; Finkelman 2004; Kaymakçi and Didari 2002; Moxon and Richardson 1985; Ren et al. 2017).
Fire prevention is the set of activities in all phases of mining activity, aiming at avoiding or reducing the chances of coal self-heating. Bustamante et al. (2018) developed a statistical analysis with the purpose of studying the susceptibility to spontaneous combustion of different coal seams in open pit mines in Colombia. The most influential variables are seam temperature, atmospheric pressure, wind speed, oxygen, methane, height, ash, volatile matter, calorific value, vitrinite, liptinite, and Hardgrove index (Chen et al. 2012; Gómez Rojas et al. 2007). Variables that could be controlled are seam temperature, wind speed, and oxygen. Some control measures that can be implemented are the sealing of coal seams with materials that have good thermal insulation and impermeability properties (Bustamante Rúa et al. 2018; Carras and Young 1994). Fire extinction is the elimination of conditions that allow a fire to continue to develop (fuel) (Wan-Xing et al. 2011). It is an expensive process and difficult to control because of the conditions to which coal fires spread within the seam (Lu et al. 2015). It is a costly and difficult process to control because of the conditions causing coal fires to spread within the seam. In this article, we deal with medium magnitude fires (up to about 700 °C of temperature) and a surface of less than 20 m2 (Fig. 6a).
The strategy adopted for dealing with the fires is a two-phase operation—first, the fires must be contained, and secondly, it should be extinguished. The methods adopted for dealing with these fires as per fire situation are as follows (Dalverny and Chaiken 1991; Gao et al. 2018; Lu et al. 2017; Mine Safety Operations Branch Industry and Investment NSW 2011; Singh 2013): hydro-pneumatic stowing, fly ash flushing, trench cutting and its filling, water circulation under pressure, cementation, stowing, blanketing, digging out, nitrogen/carbon dioxide injection, sealing by construction of isolation stoppings, remote sealing–concrete cement injection, cement water slurry spraying, infusion of silicic acid, and application of fire protective coating material and chemical inhibitors for control and combating fire.
The abovementioned techniques are being applied for control of underground as well as surface fires, depending upon the situation of fire problem. It will vary case to case and site to site basis (Singh 2013). Cerrejón implements the sealing of the coal seams with bitumen/water as a preventive measure in its mining activity, as well as the use of a backhoe for removal present in fire extinction. However, but both are done without any study on its potential optimization from a physicochemical and operational perspective of the products and equipment. This article proposes the evaluation of different technological improvements for fire prevention and extinction through pilot tests developed directly in the mine pits.
Currently, the company has problems of fire reactivation associated with the output of equipment without controlling the entire fire, sealing efficiency, inadequate control of hot material, and lack of water or chemical products in the process of temperature control. For this investigation, in order to optimize the prevention techniques to avoid the appearance of new fires in the coal seams, pilot tests were developed with some products, due to their sealing properties that allow the isolation of the coal seam with the ambient. In the case of bitumen/water and bitumen/brine are solutions that are characterized by their high adherence to the surface of the coal seam according to the measurements of contact angle made in the laboratory. Brine is an inhibitor of the spontaneous combustion of coal, contributing to the increase of the energy required for coal to reach ignition. Bitumen is a complex mixture of petroleum hydrocarbons and water. It is an aqueous dispersion of asphalt with a mixture of biodegradable cationic and nonionic surfactants, which does not produce impacts on the environment, since it is used as a preventive measure in scenarios, where it is not subjected to high temperatures. On the other hand, cement/slaked lime, cement/fine sand, and clinker/slaked lime tests were used due to their pozzolanic properties, which guarantee a special bond to the surfaces of the materials. Clinker is an inert material obtained in the mine as a result of the alteration of thermal rock due to the spontaneous combustion of coal, which is not harmful to the environment. As for the extinguishing methods used to prevent the spread of fires, pilot tests were developed with FP Coal® and water in synergy with the removal to achieve greater efficiency in the extinct. The FP Coal® product is composed of nanoclays, salts of carbonic acid, and aniconic surfactants that extinguish fires with a high degree of energy, and its biodegradable compounds are friendly to the environment.
Materials and methods
Optimization flowchart
The methodology used to optimize the new proposals in the company is described in Fig. 4. The sealing process that is clarified in Prevention-sealing and the current leading to removal cooling that is clarified in Extinction-removal cooling.
Prevention-sealing
For prevention tests, different products were used in order to evaluate sealing improvement to avoid the ignition of coal seams. The products used were bitumen/water (70/30 % v/v) and (50/50 % v/v); bitumen/brine (70/30 % v/v) and (50/50 % v/v); cement/slaked lime in 2 to 1 relation, cement/fine sand in 1 to 10 relation, and clinker/slaked lime 2 to 1 relation. Clinker referred here as red and brick-looking burnt rocks found interbedded in the Upper Paleocene Cerrejón Formation is the result of spontaneous and natural combustion of coal seams in the recent geologic past (Barros Daza et al. 2016; Heffern and Coates 2004; Quintero et al. 2009). The clinker has pozzolanic properties, which translate into cementing properties when mixed with slaked lime.
As far as bitumen is concerned, contact angle measurements were taken in order to know the adherence degree to the coal seam surface (Fig. 5). These measurements were taken for pure bitumen and for the different concentrations of bitumen/water and bitumen/brine described (Table 1).
It was observed that pure bitumen has a greater degree of adherence to the coal seam surface, and that it loses adhesion capacity as water concentration increases, due to the natural hydrophobicity of coal and water (Chang et al. 2018; Huo et al. 2014). On the other hand, brine maintains the bitumen’s adhesion capacity compared to water, which becomes evident when the angles so are so close to those used for pure bitumen.
Extinction-removal cooling
For extinction tests, two products were used to control fires. They helped support the removal work done by the backhoe. These products were FP Coal® and water. FP Coal® is used for extinguishing fires that are caused by high temperatures in coal mines. It also acts as a fireproofing agent on the mineral’s surface preventing the spread. The reagent concentrations were varied by 20 and 30% v/v.
Pilot testing for prevention and extinction
The procedure used for prevention testing was the selection of zones in the mine, which met optimum conditions of coal seam exposure and personnel safety. In order to prepare the bitumen, tanks with a capacity of 1 m3 were used and mechanically stirred until the solution homogeneity was reached. Subsequently, for coal seam sealing, the bitumen was located in the study area along with auxiliary equipment, such as the Wilden® XP 4 pump, which operated at a pressure between 90 and 100 psi, the Kaiser M50 portable air compressor 185 cfm and some hoses. The coal seams were sealed until the total coverage of the exposed area was achieved (Fig. 6). The Chemgrout 500–206 machine was used for the preparation of cement/slaked lime, cement/fine sand, and clinker/slaked lime. The machine is characterized by having two mixing tanks of 70 gal approximately on a simple platform that allows continuous mixing, using a C6 pump with a progressive cavity for its injection.
The procedure used for extinction testing was the selection of fires that allowed good accessibility and safe conditions for the entry of equipment, personnel, and machinery. Average temperatures of 700 °C were registered with the aid of Fluke 556thermal cameras (as seen in Fig. 7a). The water used for testing comes from the mine. The FP Coal® product was prepared in 1 m3 tanks, according to the aforementioned concentrations, mechanically stirring the solution until homogeneity is achieved. The auxiliary equipment used was the Wilden® XP 4 pump, Kaiser M50 portable air compressor, and hoses. The fire was extinguished by combining cooling (Fig. 7b, c) and removal (Fig. 7d) in time periods of 10 min each, until reaching a target temperature between 40 and 60 °C, where extinction is achieved.
Results and discussions
Prevention
A total of 14 sealing tests were carried out using the different products described above. The results of some of the seals made with each product are shown in Fig. 8. A total area of 1077 m2 was sealed for the study.
The monitoring carried out on the different layers, where seals were applied showed that clinker/slaked lime and cement/slaked lime products were strongly affected by wind erosion, provided the layer formed was not thick enough to prevent the wind from having a direct effect on the coal seam edges, where the greatest irregularity occurred. This condition is unfavorable considering the fact that the coal seam still has exposed areas that can come into contact with oxygen in the air and facilitate a combustion reaction. The cement/fine sand product application, on the other hand, presented difficulties due to the fact that the appropriate equipment was not available, yet it achieved good adhesion and consistency properties in the areas of the seam where it was applied.
The bitumen/brine (50/50% v/v) is the best sealing alternative that was obtained from the tests, since it reaches a better adherence and consistency than bitumen/water at the same concentration. At the same time, brine seemed to improve bitumen’s performance during application, since a larger area could be covered with the same amount of product. In the test with bitumen/brine (50/50% v/v) to 420:1 solutions was used to cover an area of 210 m2, which would be precisely the necessary amount required to cover said area, if bitumen/water was used at an equal concentration. Savings of 80:1 of solution were obtained, which proves that the use of brine provides very important benefits with respect to sealing. Additionally, it is known that salt acts as an inhibiting substance for coal spontaneous combustion, increasing the energy required by the system to reach an ignition process. It is worth noting that bitumen/brine (70/30% v/v) was not selected in spite of its good properties, considering it involves unnecessarily greater product expenditure as it forms an extremely thick layer. Figure 9 shows follow-ups performed 3 months after the tests were done.
Extinction
Results of tests carried out for fire extinction with the combination of removal and cooling are shown below in Fig. 10.
Removal as it is currently done in the company shows that the long arm backhoe requires longer times for total fire extinction due to the depth they reach inside the seam. For this study, the backhoe managed to reduce fire temperature to 340 °C in a time of 120 min. This results in operational expenses due to constant contact of equipment with high fire radiation. Shutdown operational conditions improve with the use of a cooling agent. The FP Coal® product, in concentrations of 20 and 30%, has better cooling properties compared to water. This is reflected in the time required by both products to reduce the temperature of a fire of approximately 700 °C to a temperature lower than 60 °C, where FP Coal® is 20 min faster than water (Fig. 11). In addition, the difference between the two is that the FP Coal® product generates less vapor than water when applied to a fire. The products’ penetration capacity (water and FP Coal®) is very low when the fire is attacked directly through the front, considering that only the coal seam surface layer cools down. This said, the synergy between cooling and removal processes facilitates fire extinction, by providing the backhoe operator with better working conditions and reducing the time of exposure to high temperatures and gas concentrations. The process of removal with cooling is only feasible for incipient fires and of medium magnitude, since these fires are at an early stage of propagation, therefore have failed to cover large areas and can be extinguished surface through this measure of control. On the other hand, fires of great magnitude thermodynamically are in an advanced stage of propagation, due to the mechanisms of heat transfer and chemical kinetics that allow fires to cover large areas at depth as time progresses. Therefore, for the extinction of these fires, other measures are required, such as a punctual attack in the home of the fire that is at depth.
Conclusions
-
Bitumen/brine (50/50% v/v) and bitumen/brine (70/30% v/v) were the products that achieved the best results after evaluating aspects, such as adhesion, resistance, wind erosion, and the thickness of layers formed after application; however, bitumen/brine (50/50% v/v) is the best option the company could implement, taking into account that the layer formed by bitumen/brine (70/30% v/v) is too thick, incurring unnecessary product costs and increasing the overall process cost.
-
The sealing developed with the cement/slaked lime and clinker/slaked lime products did not provide satisfactory results as determined by the follow-ups, given the products presented very low adherence and consistency over time. In addition, they were strongly affected by wind erosion, due to energy concentration produced by the wind at the seam edges.
-
Cement/fine sand sealing showed very good adhesion and consistency properties over time in spite of not being carried out correctly nor with the appropriate equipment. It was evident that the product reached high resistance in those areas where a homogeneous mixture resulted, which would be an excellent alternative to establish definitive seals inside the mine, especially in coal seams that would not be intervened later.
-
For incipient or medium-sized fires, cooling is the best way to combat them. Cerrejón incorporated the application of the improved FP Coal® method using it at a 30% v/v as a result of this study, seeing how effectively and quickly fires can be put out, in a way that allows for an improvement in terms of the environmental impact represented in a reduction of greenhouse gases, and that is economic provided the reduction of costs and time of use of the backhoe.
References
Barros Daza MJ, Bustamante Baena P, Bustamante Rúa MO (2016) Blanqueo de caolín por medio de lixiviación en pilas con ácido oxálico. Respuestas 21(1):65–76. https://doi.org/10.22463/0122820X.638
Beamish BB (2015) Spontaneous combustion of coal - general background
Beamish BB, Barakat MA, St. George JD (2001) Spontaneous-combustion propensity of New Zealand coals under adiabatic conditions. Int J Coal Geol 45(2–3):217–224. https://doi.org/10.1016/S0166-5162(00)00034-3
Bustamante Rúa MO, Daza Aragón AJ, Bustamante Baena P, Osorio Botero JD (2018) Statistical analysis to establish an ignition scenario based on extrinsic and intrinsic variables of coal seams that affect spontaneous combustion. Int J Min Sci Technol. https://doi.org/10.1016/j.ijmst.2018.05.008
Carras JN, Young BC (1994) Self-heating of coal and related materials: models, application and test methods. Prog Energy Combust Sci 20(1):1–15. https://doi.org/10.1016/0360-1285(94)90004-3
Cerrejón (2016) CERREJÓN Minería Responsable | Página de inicio. Retrieved January 8, 2017, from http://www.cerrejon.com/site/
Chang Z, Chen X, Peng Y (2018) The effect of saline water on the critical degree of coal surface oxidation for coal flotation. Miner Eng 119(November 2017):222–227. https://doi.org/10.1016/j.mineng.2018.01.020
Chen Y, Mastalerz M, Schimmelmann A (2012) Characterization of chemical functional groups in macerals across different coal ranks via micro-FTIR spectroscopy. Int J Coal Geol 104:22–33. https://doi.org/10.1016/j.coal.2012.09.001
Dalverny LE, Chaiken RF (1991) Mine fire diagnostics and iImplementation of water injection with fume exhaustion at Renton, PA
Dodamani S (2014) Controlling spontaneous combustion of coal by pyro-seizure method using brine freezing process and low temperature CO 2 injection. J Appl Chem 51–53. Retrieved from www.iosrjournals.org
Fierro V, Miranda JL, Romero C, Andres JM, Arriaga A, Schmal D, Visser GH (1999) Prevention of spontaneous combustion in coal stockpiles experimental results in coal storage yard. Fuel Process Technol 59(1):23–34. https://doi.org/10.1016/S0378-3820(99)00005-3
Finkelman RB (2004) Potential health impacts of burning coal beds and waste banks. Int J Coal Geol 59(1–2):19–24. https://doi.org/10.1016/j.coal.2003.11.002
Gao R, Yan H, Ju F, Mei X, Wang X (2018) Influential factors and control of water inrush in a coal seam as the main aquifer. Int J Min Sci Technol 28(2):187–193. https://doi.org/10.1016/j.ijmst.2017.12.017
Gómez Rojas OP, Carmona Lopez I, Bustamante Rúa MO (2007) Analysis of liberation of the groups of Macerales of the coal: Colombian coals. Boletin Cencias de La TierraCencias de La Tierra 21:14
Heffern EL, Coates DA (2004) Geologic history of natural coal-bed fires, Powder River basin, USA. Int J Coal Geol 59(1–2):25–47. https://doi.org/10.1016/j.coal.2003.07.002
Huo H, Jiang X, Song X, Li Z, Ni Z, Gao C (2014) Detection of coal fire dynamics and propagation direction from multi-temporal nighttime Landsat SWIR and TIR data: a case study on the Rujigou Coalfield, Northwest (NW) China. 1234–1259. https://doi.org/10.3390/rs6021234
Huo H, Ni Z, Gao C, Zhao E, Zhang Y, Lian Y, Zhang H, Zhang S, Jiang X, Song X, Zhou P, Cui T (2015) A study of coal fire propagation with remotely sensed thermal infrared data. Remote Sens 7(3):3088–3113. https://doi.org/10.3390/rs70303088
Jing S, Hong-qing ZHU, Zhen Z (2016) Thermal technology experiment analysis of relationship between oxygen concentration and coal oxidation characteristics thermal technology. In 5th International Conference on Recent Advances in Materials, Minerals and Environment (RAMM) & 2nd International Postgraduate Conference on Materials, Mineral and Polymer (MAMIP), 4–6 August 2015, pp 617–622
Kaymakçi E, Didari V (2002) Relations between coal properties and spontaneous combustion parameters. Turk J Eng Environ Sci 26(1):59–64. https://doi.org/10.1016/S0140-6701(03)90480-2
Kim AG (2011) Coal formation and the origin of coal fires. Coal and peat fires: a global perspective. Elsevier B.V. https://doi.org/10.1016/B978-0-444-52858-2.00001-3
Kuenzer C, Stracher GB (2012) Geomorphology of coal seam fires. Geomorphology 138(1):209–222. https://doi.org/10.1016/j.geomorph.2011.09.004
Lu X, Wang D, Qin B, Tian F, Shi G, Dong S (2015) Novel approach for extinguishing large-scale coal fires using gas–liquid foams in open pit mines. Environ Sci Pollut Res 22(23):18363–18371. https://doi.org/10.1007/s11356-015-5385-7
Lu W, Cao Y-J, Tien JC (2017) Method for prevention and control of spontaneous combustion of coal seam and its application in mining field. Int J Min Sci Technol 27(5):839–846. https://doi.org/10.1016/j.ijmst.2017.07.018
Melody SM, Johnston FH (2015) Coal mine fires and human health: what do we know? Int J Coal Geol 152:1–14
Mine Safety Operations Branch Industry and Investment NSW (2011) Technical reference for spontaneous combustion management guideline. New South Wales
Moxon NT, Richardson SB (1985) Development of a self-heating index for coal. Coal Preparation. https://doi.org/10.1080/07349348508905157
Nordon P, Young BC, Bainbridge NW (1979) The rate of oxidation of char and coal in relation to their tendency to self-heat. Fuel 58(6):443–449. https://doi.org/10.1016/0016-2361(79)90086-3
Pone JDN, Hein KAA, Stracher GB, Annegarn HJ, Finkleman RB, Blake DR, McCormack JK, Schroeder P (2007) The spontaneous combustion of coal and its by-products in the Witbank and Sasolburg coalfields of South Africa. Int J Coal Geol 72(2):124–140. https://doi.org/10.1016/j.coal.2007.01.001
Quintero JA, Candela SA, Ríos CA, Montes C, Uribe C (2009) Spontaneous combustion of the Upper Paleocene Cerrejón Formation coal and generation of clinker in La Guajira Peninsula (Caribbean Region of Colombia). Int J Coal Geol 80(3–4):196–210. https://doi.org/10.1016/j.coal.2009.09.004
Ren W, Shi J, Guo Q, Zhao Q, Bai L (2017) The influence of dust particles on the stability of foam used as dust control in underground coal mines. Process Saf Environ Prot 111:740–746. https://doi.org/10.1016/j.psep.2017.08.043
Scott GS (1994) Antracite mine fires: their behavior and control. US BUREAU OF MINES, Washington
Singh RVK (2013) Spontaneous heating and fire in coal mines. Procedia Engineering 62:78–90. https://doi.org/10.1016/j.proeng.2013.08.046
Singh P (2014) An investigation into spontaneous heating characteristics of coal and its correlation with intrinsic properties. BTech thesis
Smith KL, Smoot LD, Fletcher TH (1993) Coal characteristics, structure, and reaction rates. In: Smoot LD (ed) Fundamentals of coal combustion for clean and efficient use. Elsevier Science Publishers, Amsterdam
Timko BRJ, Derick RL (1995) Detection and control of spontaneous heating in coal mine pillars — a case study
Wang J, Chen H, Yang H & Zhang S (2011) Kinetic characteristics of coal char combustion in oxygen-enriched environment. Asia-Pacific Power and Energy Engineering Conference, APPEEC https://doi.org/10.1109/APPEEC.2011.5747672
Wan-Xing R, Zeng-Hui K, De-Ming W (2011) Procedia engineering causes of spontaneous combustion of coal and its prevention technology in the tunnel fall of ground of extra-thick coal seam. Procedia Engineering 26:717–724. https://doi.org/10.1016/j.proeng.2011.11.2228
Zhao H, Yu J, Liu J, Tahmasebi A (2015) Experimental study on the self-heating characteristics of Indonesian lignite during low temperature oxidation. Fuel 150:55–63. https://doi.org/10.1016/j.fuel.2015.01.108
Acknowledgements
We thank the Cerrejón Company for these 2 years of intense work to control fires produced by the spontaneous coal combustion and for the confidence bestowed on to the National University of Colombia—Medellin Headquarters.
Author information
Authors and Affiliations
Corresponding author
Additional information
Responsible editor: Philippe Garrigues
Rights and permissions
About this article
Cite this article
Bustamante Rúa, M.O., Bustamante Baena, P. & Daza Aragón, A.J. Optimization of techniques for the extinction and prevention of coal fires produced in final walls as a result of spontaneous combustion in the Cerrejón mine—Colombia. Environ Sci Pollut Res 25, 32515–32523 (2018). https://doi.org/10.1007/s11356-018-3201-x
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11356-018-3201-x