Abstract
In this research paper, non-conventional actuation technology, based on shape memory alloys, is employed for the development of an innovative low-cost five-fingered prosthetic hand. By exploiting the unique properties of these alloys, a compact, silent and modular actuation system is implemented and integrated in a lightweight and anthropomorphic rapid-prototyped hand chassis. A tendon-driven underactuated mechanism provides the necessary dexterity while keeping the mechanical and control complexity of the device low. Tactile sensors are integrated in the fingertips improving the overall hand control. Embedded custom-made electronics for hand interfacing and control are also presented and analyzed. For the position control of each digit, a novel resistance feedback control scheme is devised and implemented. The functionality and performance of the developed hand is demonstrated in grasp experiments with common objects.When compared to the current most advanced commercial devices, the technology applied in this prototype provides a series of improvements in terms of size, weight, and noise, which will enable upper limb amputees to carry out their basic daily tasks more comfortably.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
Rosa, A.D.L., Walker, G.R.L., Goldsmith, J.B., Elias, J.H., Godden, M.P., Greenhill, R.M.: Robotic hand. US Patent 2011/0040408 A1
Grebenstein, M., Chalon, M., Friedl, W., Haddadin, S., Wimböck, T., Hirzinger, G., Siegwart, R.: The hand of the DLR hand arm system: Designed for interaction, Vol. 31 (2012)
Bridgwater, L.B., Ihrke, C.A., Diftler, M.A., Abdallah, M.E., Radford, N.A., Rogers, J.M., Yayathi, S., Askew, R.S., Linn, D.M.: The Robonaut 2 hand - designed to do work with tools. In: 2012 IEEE International Conference on Robotics and Automation (ICRA) Saint Paul, pp. 3425–3430. Minnesota (2012)
Kyberd, P.J., Gow, D., Chappell, P.H.: Research and the future of myoelectric prosthetics. In: Muzumdar, A (ed.) Prostheses, Powered Upper Limb, pp 175-190. Springer, Berlin Heidelberg (2004)
Pons, J.L., Rocon, E., Ceres, R., Reynaerts, D., Saro, B., Levin, S., Moorleghem, W.V.: The MANUS-HAND dextrous robotics upper limb prosthesis: Mechanical and manipulation aspects. Autonom. Robots 16, 143–163 (2004)
Kargov, A., Ivlev, O., Pylatiuk, C., Asfour, T., Schulz, S., Gräser, A., Dillmann, R., Bretthauer, G.: Applications of a fluidic artificial hand in the field of rehabilitation. In: Kommu, S.S. (eds.) Rehabilitation Robotics, p. 648. Itech Education and Publishing, Vienna (2007)
Biddiss, E., Beaton, D., Chau, T.: Consumer design priorities for upper limb prosthetics. Disabil. Rehabil. Assist. Tech. 2(6), 346–357 (2007)
Pylatiuk, C., Schulz, S., Doderlein, L.: Results of an internet survey of myoelectric prothetic hand users. Prosthetics Orthot. Int. 31(4), 362–370 (2007)
Dechev, N., Cleghorn, W.L., Naumann, S.: Thumb design of an experimental prosthetic hand. In: International Symposium On Robotics and Automation, pp. 7–12. Monterrey (2000)
Touch Bionics, Inc.: i-Limb Ultra Revolution data sheet
Cipriani, C., Controzzi, M., Carrozza, M.C.: The SmartHand transradial prosthesis. J. Neuro Eng. Rehab. 8(29), 1–13 (2011)
Evans, C.O., Perry, N.C., Van Der Merwe, D.A., Violette, K.D., Coulter, S.M., Doyon, T.A., Blumberg, J.R.D.: Arm prosthetic device. US Patent 2011/0257765 A1
Schulz, S., Pylatiuk, C., Bretthauer, G.: A new ultralight anthropomorphic hand. In: 2001 IEEE International Conference on Robotics and Automation (ICRA), vol. 2433, pp. 2437–2441. Seoul (2001)
Cura, V.O.D., Cunha, F.L., Aguiar, M.L., Cliquet, A. Jr: Study of the different types of actuators and mechanisms for upper limb prostheses. Artif. Organs 27(6), 507–516 (2003). doi:10.1046/j.1525-1594.2003.07000.x
Love, L.J., Lind, R.F., Jansen, J.F.: Mesofluidic actuation for articulated finger and hand prosthetics. In: 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS). St. Louis (2009)
Kumar, P.K., Lagoudas, D.C.: Introduction to shape memory alloys. In: Lagoudas, D.C. (eds.) Shape Memory Alloy Modelling and Engineering Applications, pp. 1–51. Springer, New York (2008)
Mavroidis, C., Pfeiffer, C., Mosley, M.J.: Conventional actuators, shape memory alloys, and electrorheological fluids. In: Bar-Cohen, Y. (ed.) Automation, Miniature Robotics & Sensors for Non-Destructive Testing & Evaluation. pp. 189–214. The American Society for Nondestructive Testing, Inc. (ASNT) (2000)
DeLaurentis, K.J., Mavroidis, C.: Mechanical design of a shape memory alloy actuated prosthetic hand. Tech Health Care 10(1), 91–106 (2002)
DeLaurentis, K.J., Mavroidis, C.: Rapid fabrication of a non-assembly robotic hand. Assem Autom 24(4), 394–405 (2004)
Maeno, T., Hino, T.: Miniature five-fingered robot hand driven by shape memory alloy actuators. In: 12th IASTED International Conference, pp. 174–179. Honolulu (2006)
Cho, K.-J., Rosmarin, J., Asada, H.: SBC hand: a lightweight robotic hand with an SMA actuator array implementing C-segmentation. In: 2007 IEEE International Conference on Robotics and Automation (ICRA), pp. 921–926 (2007)
Jung, S., Bae, J., Moon, I.: Lightweight prosthetic hand with five fingers using SMA actuator. In: 11th International Conference on Control, Automation and Systems (ICCAS) Gyeonggi-do, pp. 1797–1800. Korea (South) (2011)
Lee, J.H., Okamoto, S., Matsubara, S.: Development of multi-fingered prosthetic hand using shape memory alloy type artificial muscle. Comput. Technol. Appl. 3(7), 477–484 (2012)
Bundhoo, V.: Design and evaluation of a shape memory alloy-based tendon-driven actuation system for biomimetic artificial fingers, Thesis, University of Victoria (2009)
Saether, O.F.: Flexinol as actuator for a humanoid finger-possibilities and challenges. Thesis, University of Oslo (2008)
Lan, C.-C., Yang, Y.-N.: An analytical design method for a shape memory alloy wire actuated compliant finger. In: ASME 2008 International Design Engineering Technical Conferences (IDETC) & Computers and Information in Engineering Conference (CIE), vol. 3–6, pp. 1–10. Brooklyn (2008)
Ahmed, M.A., Taher, M.F., Metwalli, S.M.: Shape memory alloy actuator system optimization for new hand prostheses World Academy of Science. Eng. Technol. 61(188), 1021–1026 (2012)
Loh, C.S., Yokoi, H., Arai, T.: New shape memory alloy actuator: Design and application in the prosthetic hand. In: 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS). Shanghai (2005)
Yang, K., Wang, Y.: Design, drive and control of a novel SMA-actuated humanoid flexible gripper. J. Mech. Sci. Technol. 22, 895–904 (2008)
Price, A.D., Jnifene, A., Naguib, H.E.: Design and control of a shape memory alloy based dexterous robot hand. Smart Mater. Struct. 16(4), 1401–1414 (2007)
Dilibal, S., Guner, E., Akturk, N.: Three-finger SMA robot hand and its practical analysis. Robotica 20, 175–180 (2002). doi:10.1017/S0263574701003757
Andrianesis, K., Tzes, A., Kolyvas, E., Koveos, Y.: Biomimetic actuation and control of an anthropomorphic finger. Int. Rev. Mech. Eng. (IREME) 2(1), 163–171 (2008)
Andrianesis, K., Tzes, A.: Design of an anthropomorphic prosthetic hand driven by shape memory alloy actuators. In: 2nd IEEE RAS/EMBS International Conference Biomedical Robotics and Biomechatronics (BioRob), pp. 517–522. Scottsdale (2008)
Andrianesis, K., Koveos, Y., Nikolakopoulos, G., Tzes, A.: Experimental study of a shape memory alloy actuation system for a novel prosthetic hand. In: Cismasiu, C. (ed.) Shape Memory Alloys, pp. 81-106. InTech (2010)
Andrianesis, K., Tzes, A.: Design of an innovative prosthetic hand with compact shape memory alloy actuators. In: 21st Medit. Conference Control and Automation (MED), Platanias-Chania, Crete (2013)
Jones, L.A., Lederman, S.J.: Human hand function. Oxford University Press, Inc., New York (2006)
Banks, J.L.: Design and control of an anthropomorphic robotic finger with multi-point tactile sensation. Thesis, Massachusetts Institute of Technology (2001)
Hollister, A., Buford, W.L., Myers, L.M., Giurintano, D.J., Novick, A.: The axes of rotation of the thumb carpometacarpal joint. J. Orthop. Res. 10(3), 454–460 (1992)
LaViola, J.J. Jr.: A survey of hand posture and gesture recognition techniques and technology. In: vol. CS-99-11. Brown University, Providence (1999)
Feix, T.: Anthropomorphic hand optimization based on a latent space analysis, Thesis, Technical University of Vienna (2011)
Henderson, A., Pehoski, C.: Hand function in the child: Foundations for remediation. Mosby, St. Louis, Missouri (2006)
NASA: Anthropometry and biomechanics. In: Man-systems integration standards, vol. 1. vol. 3 (1995)
Weir, R.F., Sensinger, J.W.: The design of artificial arms and hands for prosthetic applications. In: Kutz, M. (ed.) Biomedical Engineering and Design Handbook, pp. 537–598. McGraw-Hill, New York (2009)
Sangole, A.P., Levin, M.F.: Arches of the hand in reach to grasp. J. Biomech. 41(4), 829–837 (2008)
Gosselin, C., Pelletier, F., Laliberte, T.: An anthropomorphic underactuated robotic hand with 15 Dofs and a single actuator. In: IEEE International Conference on Robotics and Automation (ICRA), pp. 19–23. Pasadena (2008)
Birglen, L., Laliberté, T., Gosselin, C.: Design and control of the Laval underactuated hands. In: Underactuated Robotic Hands. Springer Tracts in Advanced Robotics, vol. 40, pp. 171–207. Berlin Heidelberg, Springer (2008)
Birglen, L., Laliberté, T., Gosselin, C.: Grasping vs. manipulating. In: Underactuated Robotic Hands, vol. 40, pp. 7–31. Springer Berlin, Heidelberg, Berlin (2008)
Buchholz, B., Armstrong, T.J., Goldstein, S.A.: Anthropometric data for describing the kinematics of the human hand. Ergonomics 35(3), 261–273 (1992). doi:10.1080/00140139208967812
Gómez, G., Hernandez, A., Hotz, P.E.: An adaptive neural controller for a tendon driven robotic hand. In: Arai, T. (ed.) 9th International Conference on Intelligent Autonomous Systems (IAS), pp. 298-307. Tokyo, IOS Press (2006)
Palm, W.: Rapid prototyping primer. In: vol. 2/4/2010. Penn State Learning Factory (1998)
Martin, T.B., Ambrose, R.O., Diftler, M.A., Platt, R. Jr., Butzer, M.J.: Tactile gloves for autonomous grasping with the NASA/DARPA Robonaut. In: 2004 IEEE International Conference on Robotics and Automation (ICRA), vol. 1712, pp. 1713–1718. New Orleans
Evanczuk, S.: Fundamentals of temperature-sensing devices (2011)
Mohd Jani, J., Leary, M., Subic, A., Gibson, M.A.: A review of shape memory alloy research, applications and opportunities. Mater. Des. 56(0), 1078–1113 (2014). doi:10.1016/j.matdes.2013.11.084
In: Smith, D.G., Michael, J.W., Bowker, J.H. (eds.) : Atlas of Amputations and Limb Deficiencies, 3rd edn. American Academy of Orthopaedic Surgeons (2004)
In: Muzumdar, A. (ed.) : Powered Upper Limb Prostheses: Control, Implementation and Clinical Application, 1st edn. Springer, New York (2004)
Madden, J.D.W., Vandesteeg, N.A., Anquetil, P.A., Madden, P.G.A., Takshi, A., Pytel, R.Z., Lafontaine, S.R., Wieringa, P.A., Hunter, I.W.: Artificial muscle technology: Physical principles and naval prospects. IEEE J. Ocean. Eng. 29(3), 706–728 (2004). doi:10.1109/joe.2004.833135
Uustal, H., Baerga, E.: Prosthetics and orthotics. In: Cuccurullo, S.J. (ed.) Physical Medicine and Rehabilitation Board Review. Demos Medical Publishing, New York (2004)
Dynalloy, Inc.: Technical Characteristics of Flexinol Actuator Wires (2010)
Abolfathi, P.P.: Development of an Instrumented and Powered Exoskeleton for the Rehabilitation of the Hand, Thesis, University of Sydney (2007)
MacGregor, R.: Shape memory alloy actuators and control methods. US Patent 6,574,958 (2003)
Belter, J.T., Dollar, A.M.: Performance characteristics of anthropomorphic prosthetic hands. In: 2011 IEEE International Conference on Rehabilitation Robotics (ICORR), ETH Zurich, pp. 921–927. Switzerland (2011)
Teh, Y.H., Featherstone, R.: An architecture for fast and accurate control of shape memory alloy actuators. Int. J. Robot. Res. 27(5), 595–611 (2008). doi:10.1177/0278364908090951
Ma, N., Song, G., Lee, H.-J.: Position control of shape memory alloy actuators with internal electrical resistance feedback using neural networks. Smart Mater. Struct. 13(4), 777–783 (2004). doi:10.1088/0964-1726/13/4/015
Chatterjee, A., Aggarwal, V., Ramos, A., Acharya, S., Thakor, N.V.: A brain-computer interface with vibrotactile biofeedback for haptic information. J. NeuroEngineering Rehabil. 4(40) (2007)
Davalli, A., Sacchetti, R., Fanin, S., Avanzolini, G., Urbano, E.: Biofeedback for upper limb myoelectric prostheses. Technol. Disabil. 13, 161–172 (2000)
Engeberg, E.D., Meek, S.: Enhanced visual feedback for slip prevention with a prosthetic hand. Prosthetics Orthot. Int. 36(4), 423–429 (2012). doi:10.1177/0309364612440077
Sapsanis, C., Georgoulas, G., Tzes, A., Lymberopoulos, D.: Improving EMG based Classification of basic hand movements using EMD. In: 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp. 5754–6757. Osaka
Lake, C., Dodson, R.: Progressive upper limb pros- thetics. Phys. Med. Rehabil. Clinics N. Am. 17(1), 49–72 (2006)
Cocaud, C., Price, A., Jnifene, A., Naguib, H.: Position control of an experimental robotic arm driven by artificial muscles based on shape memory alloys. Int. J. Mech. Mater. Des. 3(3), 223–236 (2006)
Ashrafiuon, H., Eshraghi, M., Elahinia, M.H.: Position control of a three-link shape memory alloy actuated robot. J. Intell. Mater. Syst. Struct. 17(5), 381–392 (2006)
Rezaeeian, A., Yousefi-Koma, A., Shasti, B., Doosthoseini, A.: ANFIS modeling and feedforward control of shape memory alloy actuators, Vol. 2 (2008)
Cho, K.-J., Asada, H.: Architecture design of a multi-axis cellular actuator array using segmented binary control of shape memory alloy. IEEE Trans. Robot. 22(4), 831–843 (2006)
Zecca, M., Roccella, S., Cappiello, G., Ito, K., Imanishi, K., Miwa, H., Carrozza, M.C., Dario, P., Takanishi, A.: From the human hand to a humanoid hand: Biologically-inspired approach for the development of Robocasa Hand #1. In: Zielinska, T., Zielinski, C. (eds.) 16th CISM-IFToMM RoManSy Symposium, pp. 287–294. Warsaw, Springer
Pikul, J.H., Gang Zhang, H., Cho, J., Braun, P.V., King, W.P.: High-power lithium ion microbatteries from interdigitated three-dimensional bicontinuous nanoporous electrodes. Nat. Commun. 4, 1732 (2013). doi:10.1038/ncomms2747
Author information
Authors and Affiliations
Corresponding author
Electronic Supplementary Material
Below is the link to the electronic supplementary material.
(MPG 24.5 MB)
Rights and permissions
About this article
Cite this article
Andrianesis, K., Tzes, A. Development and Control of a Multifunctional Prosthetic Hand with Shape Memory Alloy Actuators. J Intell Robot Syst 78, 257–289 (2015). https://doi.org/10.1007/s10846-014-0061-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10846-014-0061-6
Keywords
- Upper limb prosthetics
- Multifingered hands
- Underactuated robots
- Smart actuators
- Shape memory alloys
- Resistance feedback control