Abstract
Summer heat in coastal subtropical Jeddah, augmented by heat from operating ground servicing equipment in King Abdul-Aziz International Airport (KAAIA), presents a major occupational problem to ground service operators, particularly the air traffic control coordinator (ATCC), that hinders their work efficiency and induces health disorders to them. The present study was conducted to assess the magnitude of this problem and propose heat control strategy and remedial actions for the Saudi Arabian Airlines (SAUDIA). Heat parameters including air temperature (T a), wet bulb temperature (T w), globe temperature (T g) and air velocity were measured around serviced planes and in other locations used by ATCC, and the WBGT and the ATCC-WBGT-TWAs were computed. Mostly all the T a measurements, and many T w measurements, were higher than T a and T w forecasted by the Presidency of Meteorology and Environment (PME) due to heat dissipated from operating vehicles and equipment in service. The measured and PME forecasted parameters have good and medium linear correlations (T a: r 2 = 0.74 and T w: r 2 = 0.64). The computed WBGT in the service stations around planes are considerably higher than the 25 and 27.5°C recommended TLV® for non-acclimatized and acclimatized operators. However, the computed ATCC- WBGT-TWA levels indicate that the shift-work-schedule which was recommended to be implemented by SAUDIA has successfully reduced their heat exposure to acceptable levels, except for a very few operators (6.7% exceeding WBGT-TLV® of 25°C and 2.2% exceeding TLV® of 27.5°C) for whom the shift-work schedules might be corrected to achieve safe heat exposure.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
Al-Jiffry, M. A., Al-Idrissi, M. M., Al-Jiffry, M. S., Jamil, A., & Erturk, F. (1990). Heat stress assessment in the industrial facilities (A Case Study). Journal of Environmental Science and Health, A25, 209–230.
Bruel & Kaier (1985). Instruction manual: Heat stress monitor type 1219. B & K, DK-2850. Naerum, Denmark.
Hisamatsu, (1985). Instruction sheet:Model 3-1440 thermal anemometer. Tokyo, Japan: Hisamatsu Manufacturing Co. Ltd.
Kielblock, J. (2002). Heat stress management: An occupational hygiene perspective. Journal of the Mine Ventilation Society of South Africa, 25(1), 24–27.
Leithend, C. S., & Lind, A. R. (1964). Heat stress and heat disorders. USA: Davis Co. Philadelphia, Pa.
Minard, D. (1966). Evaluation of heat stress under working conditions. Proceeding of the VI conference of the industrial council for tropical health. Boston, Ma, USA: Harvard School of Public Health.
MMWR (1984). Fatalities from occupational heat exposure. MMWR, 33, 410–412 (July 20).
MMWR (1995). Heat related illness and death—United States 1994–1995. MMWR, 44, 465–8.
MMWR (1998). Heat related morality—United States 1997. JAMA, 280, 316–7.
Mutchler, J. E. (1991). “Heat stress”: Its effects, measurement and control. In C. D. Clayton, & F. E. Clayton (Eds.) Patty’s industrial hygiene and toxicology, vol. 1-A ((pp. 399–430)4th ed.). New York, NY, USA: John Wiley.
NIOSH (1986). Criteria for a recommended standard. Occupational exposure to hot environment. National Institute for Occupational safety and Health, Cincinnati: Document # 83–113.
NIOSH (1993). Fatal Injuries to workers in the United States 1980–1989. A Decade of Surveillance. National Institute for Occupational Safety and Health, Cincinnati: Document # 93–108.
Noweir, M. H., Moreb, A. A., & Bafail, A. O. (1996). Study of heat exposure in the work environment in Jeddah. Environmental Monitoring Assessment, 40, 225–237.
Ramsey, J. D., & Beshir, M. Y. (1997). “Thermal standards and measurement techniques”. In S. R. DiNardi (Ed.) The occupational environment—its evaluation and control (pp. 660–691). FairFax, Va, USA: Amer. Ind. Hyg. Assoc.
Srivastava, A., Kumar, R., Joseph, E., & Kumar, A. (2000). Heat exposure study in the work place in a glass manufacturing unit in India. American Occupational Hygiene, 44, 449–453.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Noweir, M.H., Bafail, A.O. Study of summer heat exposure at the ground services operations of a main international airport in Saudi Arabia. Environ Monit Assess 145, 103–111 (2008). https://doi.org/10.1007/s10661-007-0019-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10661-007-0019-2