Abstract
The present work was conducted to define the magnitude of the problem of heat exposure in Jeddah and the role of both the climatic and the industrial factors on the total heat load. Indoor heat exposure was studied in an industrial complex of 5 plants for cables' manufacturing. Outdoor heat exposure was studied in shaded and unshaded operations in Jeddah Islamic Port (JIP). The heat exposure parameters, including air temperature (Ta), wet bulb temperature (Tw), and globe temperature (Tg), as well as the wet bulb globe temperature (WBGT) heat stress index, the relative humidity and the air velocity, were assessed at representative locations. Results of the study indicated that:
-
(a)
the levels of heat exposure exceeded the TLV in mostly all the work areas where no air-conditioning is provided.
-
(b)
the ambient heat is the factor contributing most to the heat load both in summer and in winter.
-
(c)
the radiant heat from furnaces and hot metal rolling and milling adds more heat load to the work environment in specific operations.
An outline of a control strategy has been suggested, emphasizing evaporative engineering heat control, work and hygienic practices and auxiliary cooling clothing.
Article PDF
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
References
ACGIH: 1994, Threshold Limit Values (TLV) and Biological Exposure Indices 1994/1995, American Conference of Governmental Industrial Hygienists, Cininnati, OH, USA.
AIHA: 1973, The Stress of Hot Environment, American Industrial Hygiene Association, Fairfax, VA, USA.
ASHRAE: 1977, Handbook of Fundamentals, American Society of Heat and Refrigeration Engineering, New York, NY, USA.
B&K: 1985, Heat Stress Monitor Instruction Manual, Brual & Kjaer, Copenhagen, Denmark.
CMEC: 1991, Climatological Temperature Data of 1990, 1991, College of Meteorology and Environmental Control, King Abdul-Aziz University, Jeddah, KSA.
Fanger, P. O.: 1972, Thermal Comfort, McGraw-Hill, New York, NY, USA.
Hisamatu: 1985, Thermal Anemometer (Model-31440) Operating Instruction, Hisamatu Manufacturing Co., Tokyo, Japan.
Holmer, I.: 1988, ‘Protective Clothing and Heat Stress’, in: Heat Stress Indices, EEC Symposium, 25–26 October, Luxembourg, pp 373–411.
Leithend, C. S. and Lind, A. R.: 1964, Heat Stress and Heat Disorders, Davis Co., Philadelphia, Pa, USA.
Minard, D.: 1966, ‘Evaluation of Heat Stress Under Working Conditions’, Proceedings of the VI Conference of the Industrial Council for Tropical Health, Harvard School of Public Health, Boston, Ma, USA.
Mutchhler, J. E.: 1991, ‘Heat Stress: Its Effect, Measurement and Control’, in: Clayton, C. D. and Clayton, F. E. (eds), Patty's Industrial Hygiene and Troxicology, Vol. I-A., 4th edn. John Wiley, New York, NY, USA, pp 763–838.
NIOSH: 1973, The Industrial Environment: Its Evaluation and Control, National Institute for Occupational Safety and Health, Cincinnati, OH, USA, pp. 399–430.
NIOSH: 1986, Occupational Exposure to Hot Environments: Revised Criteria. National Institute for Occuptional Safety and Health, DHHS (NIOSH) Publication No. 86-113, Cincinnati, OH, USA.
Olesen, B. W. and Madsen, T.L.: 1988, ‘Measurements of Physical Parameters of the Thermal Environment’, in: Heat Stress Indices, EEC Symposium, 25–26 October, Luxembourg, pp. 247–298.
Peters, H.: 1988, ‘Testing Climate Indices in the Field’, ibid, pp. 135–136.
SPAP: Annual Report. Saudi Public Agency for Ports, Jeddah, KSA.