1 Introduction

The contribution of infills in seismic response of framed reinforced concrete structures is significant; nevertheless, they are usually neglected in models assuming a non-structural function. The seismic damage on this kind of structures suggests, as widely discussed in literature, the fact that frames and infills have a strong interaction when involved in seismic events, not always being beneficial for structural safety and not negligible in general.

Though an infilled frame exibits a significant increase in lateral strength and stiffness with respect to the corresponding bare one this fact cannot be extended to the whole structural behaviour depending on the distribution of infills. It can be generally stated that, if the planar and elevation distributions are regular and approximately symmetric, the contribution of infill panels is beneficial; contrariwise infills are potentially dangerous, often causing activation of additional torsional effects and soft story mechanisms.

Regarding a single frame, the increase in strength mentioned before is associated with an increase in the demand for shear capacity in some specific sections. This aspect of the frame–infill interaction constitutes the central issue of this paper.

As is well known, in the presence of lateral actions, the infill panel partially disconnects from the frame, remaining in contact with it only near two opposite corners (Fig. 1).

Fig. 1
figure 1

Transmission of local shear forces close to the beam–column joints in presence of lateral actions

Strength increase occurring on infilled frames is allowable, however, if RC members adjacent to panels (beams, columns and joints) have sufficient shear overstrength. When especially strong masonry infill panels are combined with frames having a low shear reinforcement, the activation of local brittle collapse mechanisms, able to compromise the capacity and safety of the entire structure becomes a major question. In Fig. 2 a picture referring to local shear failure mechanism due to frame–infill interaction is reported.

Fig. 2
figure 2

Local shear failure of frame due to interaction with infills under seismic loads

The frame–infill interaction has been treated by several authors which have proposed strategies to introduce the effects of infills in structural models. A very successful technique is based on the replacement of the infill with one or more equivalent diagonal struts. This technique, belonging to the macromodel approaches, was first introduced by Holmes (1961) and then developed by other researchers (Asteris et al. 2011; Chrysostomou and Asteris 2012; Crisafulli et al. 2000).

In the most simple case one equivalent pin-jointed concentric strut is used by means of that it is possible to obtain good reliability in modelling the stiffening effects produced by infill panels (e.g. Papia et al. 2003). Unfortunately, as a counterpart of its simplicity, this approach is unable to provide the internal forces in beams and columns, close to the joints, arising because of frame–infill interaction.

More complex macromodels making use of multiple diagonal struts (two or three), able to reproduce these effects, have also been developed (e.g. Crisafulli and Carr 2007; Fiore et al. 2012). However, identification of the mechanical properties to attribute to each strut is not a simple question since these depend not only on masonry mechanical properties but also on the frame–infill stiffness ratios and on the geometrical characteristics of the system (Asteris 2003, 2008; Cavaleri and Papia 2003). The difficulties in managing multi-strut approaches grow when nonlinear (static o dynamic) analyses are required since the attribution of specific monotonical or cyclic nonlinear laws is necessary for each strut.

A substantially different approach has been instead followed by other authors (e.g. Mallick and Severn 1967; Mehrabi and Shing 1997; Shing and Mehrabi 2002; Ghosh and Made 2002; Asteris 2008; Koutromanos et al. 2011) which have adopted an “exact representation” of infills (micromodelling) to better reproduce frame–infill interaction. According to this modelling approach, panel and frames are modelled by means of planar shell finite elements while interface elements able to reproduce frictional effects and frame–infill detachment are considered for frame–infill contact regions. Such typology of approach, which is aimed at providing a more accurate response, is able to capture well local interaction effects and frame global internal force distribution, but in this case too, calibration of the analytical models, especially in terms of nonlinear laws for shell elements and interfaces, is not easy to accomplish. Furthermore, analyses of framed structures which make use of micromodels require a higher computational effort which is not always acceptable for practical engineering uses.

Also technical codes point out the need to take into account the frame–infill interaction. Eurocode 8 when furnishing indications about modelling in structural analysis prescribes that infill walls which contribute significantly to the lateral stiffness and resistance of building have to be considered. Unfortunately no reference models for infills are provided.

In a similar way in the Italian technical code (D.M. LL. PP. 2008) neither are modelling criteria given nor is a strategy suggested to predict the local increase of shear in the columns and in the beams of infilled frames close to the nodal regions.

Differently from Eurocode 8 and the Italian codes, the Federal Emergency Management Agency code (FEMA 356) dedicates a significant attention to describe how to take infills into account and how to predict the local effects on beams and columns. One possible choice that is offered is to model an infill by an equivalent pin-jointed strut that should have the same thickness and modulus of elasticity as the infill panel while the width \(w\) is given by

$$\begin{aligned} w= 0.175 \left( {\lambda _1 h^{\prime }} \right) ^{- 0.4}d \end{aligned}$$
(1)

where, referring to Fig. 3, \(h^{\prime }\) is the height of the frame, measured between the centre-lines of the beams, \(d\) is the measure of the diagonal dimension of the infill and \(\lambda _{1}\) is given by

$$\begin{aligned} \lambda _1 =\left[ {\frac{E_{d } t\sin 2\theta }{4 E_f I_c h}} \right] ^{\frac{1}{4}} \end{aligned}$$
(2)

in which \(t\) is the thickness of the infill and \(h\) and \(\ell \) are its height and length, respectively, \(\theta =atan(h/\ell )\), \(I_{c}\) is the moment of inertia of the column cross-sections and \(E_{d }\) and \(E_{f}\) are the Young’s modulus of the infill and of the material constituting the frame, respectively.

Fig. 3
figure 3

Geometrical features of a frame–infill system and of the equivalent diagonal strut

Referring to local interaction effects, the FEMA code specifies that beams and columns adjacent to infills should have sufficient strength to support local shear effects. According to the strategy proposed, in absence of more accurate models and analyses, the FEMA code-states that the flexural and shear strength of beams and columns close to nodal regions should exceed the internal forces evaluated by the application, at the specified lengths \(l_{ceff}\) and \(l_{beff}\), of the horizontal and vertical components of the expected axial force value for an equivalent strut (Fig. 4). The lengths \(l_{ceff}\) and \(l_{beff}\) can be obtained as

$$\begin{aligned} l_{ceff}&= \frac{w}{\cos \theta _c } ;\,\tan \theta _c =\frac{h-l_{ceff} }{\ell }\end{aligned}$$
(3)
$$\begin{aligned} l_{beff}&= \frac{w}{\sin \theta _b } ;\,\tan \theta _b =\frac{h}{\ell -l_{beff} } \end{aligned}$$
(4)

Although the question of local failure of RC members adjacent to infills is treated in FEMA 356 more than in other codes, the strategies suggested, not deriving from a specific analysis and basing on expected values for equivalent strut strength may lead to an unreliable estimation.

Fig. 4
figure 4

Schemes for the evaluation of local effects according to FEMA 356: a on columns; b on beams

Considering all premises above, this paper provides a study in which the relevance of the local shear interaction effects is pointed out, giving the basis for a tool as rigorous as it is simple for the prediction of the real distribution of shear demand in the critical sections of frames when a single equivalent concentric strut is used.

The study, regarding a single infilled frame that can be viewed as a part of a more complex framed structure, is based on the comparison of the results derived from two modelling approaches: one (M1 model) providing the simple single-strut approach; the other one (M2 model) using plane–shell elements to model infills, nonlinear beam elements at the contour and multilinear elastic links (MElink) resisting in compression only at the frame–infill interface. Comparisons are carried out, with variation in mechanical features, geometry, stiffening and strength ratios between frame and infill, in order to determine, for fixed interstorey drifts, the relationship between the axial force evaluated on the equivalent strut and the shear forces (negligible in the M1 model) evaluated in critical sections of beams and columns in the M2 model. The final aim is to permit use of the simple equivalent concentric strut approach for the analysis, this approach being able to provide adequate correction coefficients for local shear forces arising in the beams and in the columns near the joints.

This allows to have a wider consciousness of the mechanics of the frame–infill systems varying the characteristics of infills. Further, here, the independence of the level of shear in the columns and beams from the interstory drift has been proved, thanks to a major and more detailed numerical simulations, providing a decisive advance for the future of the prediction of local effects in infilled frames. Hence an updated tool for the prediction of the above effects has been presented. Finally a comparison has been made between the tool proposed here and the strategy proposed by FEMA for the prediction of the shear due to infills in frame members.

2 Modelling

As mentioned above the results of this work are based on a comparative procedure between two different approaches used to model the same structural system. Having as reference the generic infilled frame, whose geometrical features are indicated in Fig. 5, the structural responses at fixed interstorey drifts are compared in detail. The M1 model (Fig. 6) is based on the classical assumption of replacing an infill with an equivalent diagonal concentric strut. This model requires a very low computational effort and is really efficient when nonlinear analyses have to be carried out, although it is affected by a significant defect due to the impossibility of evaluating the interferences of infills in local internal force distribution on the RC members. The M2 model (Fig. 8), which instead requires a higher computational effort, allows one to evaluate the influence of the infill on the internal forces in RC members thanks to the modelling of the infill in finite elements connected to beams and columns through interfaces elements able to transfer normal forces to the surrounding frame.

Fig. 5
figure 5

Generic features of an infilled frame

Fig. 6
figure 6

M1 model: geometrical and mechanical scheme

Models M1 and M2 can be considered equivalent and results can be compared under monotonic loading when they exhibit the same stiffness in both the linear and nonlinear fields. More generally, the stiffness equivalence can be defined as a function of interstorey drift \((d_{r})\) and expressed by the equation

$$\begin{aligned} K_{M1} (d_r )=K_{M2} (d_r ) \end{aligned}$$
(5)

\(K_{M1} (d_{r})\) and \(K_{M2} (d_{r})\) being the lateral secant stiffness of the M1 and M2 models for a generically assigned \(d_{r}\).

Analyses and modelling were performed using SAP 2000 NL. The characterization of the M1 and M2 models is indicated below, while the details of comparisons procedures and results are discussed in the following sections.

2.1 M1 model

The M1 model (Fig. 6) is obtained by the application of the equivalent strut approach. The geometrical and mechanical characteristics of the RC infilled frame from which it is originated are shown in Fig. 5. There, \(b_{b}\) and \(h_{b}\) are the width and the depth of the beam cross-sections, respectively and \(A_{b}\) the corresponding area, while \(b_{c}\) and \(h_{c}\) are the width and the depth of the column cross-sections, respectively and \(A_{c}\) the area. Regarding to the elastic parameters, the concrete constituting the frame is identified by the Young modulus \(E_{f}\). while masonry constituting infills is mechanically characterized by the parameters \(E_{1},\,E_{2},\,G_{12},\,\nu _{12}\) which are respectively the Young moduli, rigidity modulus and Poisson ratio referred to directions 1 and 2.

The identification of the equivalent diagonal strut cross-section width \(w\) is performed by means of the expression below (Papia et al. 2003).

$$\begin{aligned} w =d\,\kappa \frac{c}{z} \frac{1}{\left( {\lambda ^{*}} \right) ^{\beta ^{*}}} \end{aligned}$$
(6)

where d is the infill diagonal length and \(c\) and \(\beta ^{*}\) are coefficients depending on the Poisson ratio \(\nu _{d}\) along the diagonal direction (along which the equivalent strut lies) and are defined by the equations

$$\begin{aligned} c&= 0.249-0.0116\,\nu _d +0.567\,\nu _d^{2}\end{aligned}$$
(7)
$$\begin{aligned} \beta ^{*}&= 0.146 + 0.0073\,\nu _d + 0.126\,\nu _d^{2}, \end{aligned}$$
(8)

further \(z\) is a coefficient depending on the panel shape and can be evaluated as

$$\begin{aligned} z=1+0.25(\ell /h-1) \end{aligned}$$
(9)

where \(\ell \) and \(h\) are the infill dimensions. The coefficient \(\kappa \) appearing in Eq. 6 takes into account the effect of the vertical loads which generically act con columns and involve infill panels. This coefficient can be obtained as a function of the mean vertical deformation \(\varepsilon _{v }\) experienced by columns as effect of the compressive load \(F_{v}\) (Amato et al. 2008), through the equation

$$\begin{aligned} \kappa =1+(18\lambda ^{*}+200)\varepsilon _v \end{aligned}$$
(10)

in which \(\varepsilon _{v}\) is calculated as

$$\begin{aligned} \varepsilon _v =\frac{F_v }{2A_c E_f } \end{aligned}$$
(11)

\(E_{f}\) and \(A_{c}\) being, as before mentioned, respectively the elastic modulus of the concrete constituting the frame and \(A_{c}\) of the cross-section areas of the columns (\(A_{c}\) has to be intended as the average of the column cross-section areas in the case of different columns—the elastic modulus \(E_{f}\) can implicitly include all the phenomena involving the frame in the first loading stage, comprised the first cracking if the vertical loads are not able to prevent it.). Finally the parameter \(\lambda ^{*}\) (Eqs. 6 and 10), is a parameter representative of the frame–infill system and characterizes the stiffness ratios between infill and frame: it is defined as follows:

$$\begin{aligned} \lambda ^{*} = \frac{E_d }{E_f }\frac{t\,h^{\prime }}{A_c }\left( {\frac{h^{\prime 2}}{\ell ^{\prime 2}}+\frac{1}{4}\frac{A_c }{A_b }\frac{\ell ^{\prime }}{h^{\prime }} } \right) \end{aligned}$$
(12)

where \(E_{d}\) is the infill elastic modulus along the diagonal direction, \(t\) is the infill thickness, \(h^{\prime }\) and \(\ell ^{\prime }\) are respectively the frame dimensions in agreement to Fig. 3, \(A_{b}\) is the average of the cross-section areas of the beams.

The evaluation of masonry elastic Young modulus \(E_{d}\) and the Poisson ratio \(\nu _{d}\) along the diagonal direction can be easily carried out as a function of the mechanical parameters mentioned above \((E_{1},\,E_{2},\,G_{12},\,\nu _{12})\) according to the procedure proposed in Cavaleri et al. (2014).

The constitutive law that governs the equivalent strut is defined by a trilinear axial force–axial displacement compressive diagram (axial meaning along the direction of the strut) having no tensile strength (Fig. 7) in which the initial elastic stiffness \(K_{1}\) is evaluated as

$$\begin{aligned} K_1 =\frac{E_d tw}{d} \end{aligned}$$
(13)

while the strength at the elastic limit \(F_{1}\) is defined as a function of the parameter \(\alpha <1\), which defines the ratio between the peak strength and the level of the resisting force at the end of the elastic branch, that is

$$\begin{aligned} F_1 =\alpha F_2 \end{aligned}$$
(14)

The stiffness in the post-elastic branch \(K_{2}\) is instead related to the parameter \(\beta \), which regulates the loss of stiffness after the yielding point with respect to the initial one:

$$\begin{aligned} K_2 =\beta K_1 \end{aligned}$$
(15)

The displacements at the elastic limit and peak strength are therefore directly identified as

$$\begin{aligned} \delta _1 =F_1 /K_1 ;\,\delta _2 =\delta _1 +(F_2 -F_1 )/K_2 \end{aligned}$$
(16)

The trend of the softening branch is linearized and obtained by connecting points \(F_{2}-\delta _{2}\) and \(F_{3}-\delta _{3}\), assuming that \(F_{3} =0.7F_{2}\) and calculating \(\delta _{3}\) by the expression below (Cavaleri et al. 2005)

$$\begin{aligned} \delta _3 =\frac{1}{\zeta }\ln \left[ {\frac{F_2 }{F_3 }\exp (\zeta \delta _2 )} \right] \end{aligned}$$
(17)

where \(\zeta \) is a coefficient defining the decay velocity of the post peak branch.

Fig. 7
figure 7

Axial force–axial displacement law for equivalent diagonal strut

The equivalent strut peak strength \(F_{2}\) is finally determined as a function of the mean shear strength of the masonry infill panel \(f_{v0m}\) as follows:

$$\begin{aligned} F_2 =f_{v0m} t\ell ^{*} \end{aligned}$$
(18)

in which \(\ell ^{*}\) represents the ideal length of the panel that coincides with the real length \(\ell \) in the case of square infills \((\ell /h=1)\) and undergoes a reduction down to \(0.7 \ell \) when \(\ell /h=2\). This assumption takes into account a strength reduction due to the aspect ratio of the infills, especially for rectangular long infills, experimentally observable (Mehrabi et al. 1996).

The equivalent strut properties are introduced in the model by means of a Multilinear Elastic Link (MElink) element available in the SAP 2000 libraries.

The frame mechanical nonlinearities are introduced by means of 4 interacting axial force-bending moment plastic hinges (P–M) placed at the ends of the columns to be representative of the case of a non-seismically designed strong beam-weak column frame.

The hinge properties depend in each case on the cross-section geometrical features and on the reinforcement.

The concrete strength is assumed to be 25 MPa and an unconfined constitutive law is attributed to consider low transversal reinforcement. The steel rebar strength is set equal to 450 MPa and an elastic perfectly plastic law is attributed. Nodal regions at the intersections between beams and columns are modelled as rigid links. The reinforcement geometrical ratio is set equal to 1 % for all column sections and it is furthermore assumed that the beams have a higher flexural strength than the columns, as in the case of structures designed to resist gravity loads only. Finally, a dimensionless axial force \(n=0.2\) is assigned on top of the columns.

The calibration of the parameters \(\alpha ,\,\beta \) and \(\zeta \), which characterize the shape of the monotonic law of the equivalent strut, were provided by carrying out pushover analyses and comparing them with the experimental results of different types of system tested and available in the literature (e.g. Koutromanos et al. 2011; Cavaleri et al. 2005; Mehrabi et al. 1996; Cavaleri and Di Trapani 2014; Korkmaz et al. 2010; Chiou et al. 1999). Pushover curves were compared with the results of monotonic tests or with the envelope of the strengths of cyclic tests. It has been verified that, meanly, the values for the \(\alpha ,\,\beta \) and \(\zeta \) that can be adopted for defining the shape the response of an infilled frame are the ones inserted in Table 1.

Table 1 Parameters regulating equivalent diagonal strut constitutive law

Besides, basing on results of experimental tests reported in (Cavaleri et al. 2012, 2014) for different typologies of masonries, it is assumed that the elastic Young modulus ratio \(\gamma =E_{1} /E_{2}\) is equal to \(0.75\), the shear modulus \(G_{12} =0.4\,E_{2}\) and the Poisson’s ratio \(\nu _{d}=\nu _{12} =0.1.\) Different values for the shear strength \(f_{v0m}\) of the panels (from 0.50 to 1.07 MPa) are considered in the analyses. The above mentioned parameters governing the equivalent strut compressive law each time are summarized in Table 1.

With regards to the modelling of the frame-strut, when the strategy of substitution of infill with an equivalent strut is adopted, the non exact correspondence between the real state evolution (e.g. cracking pattern, failure modes, etc.) and the model structural state is generally accepted as long as a match, by the global phenomenological point of view, is obtained in lateral stiffness, in lateral strength, in degradation of stiffness and strength, in residual strength, etc, (e.g. Shing and Stavridis 2014; Asteris and Cotsovos 2012; Asteris et al. 2013). This is the natural consequence of the substitution of a substructure (namely an infill) with a deeply different element (namely a strut). The calibration of an equivalent strut able to match the global phenomenon takes account the possibility of formation of plastic hinges at critical regions of frame members. Further, a comparison between the “exact model” and the simplified model highlights normally a comparable sequence in the formation of the plastic hinges at ends of the columns although this fact cannot be considered a rule (e.g. Fiore et al. 2012)

2.2 M2 model

Referring to the generic infilled frame (Fig. 5), the M2 model was also defined (Fig. 8) characterized by detailed discretization of infill by means of orthotropic elastic shell elements. The assumptions for the elastic properties of the masonry (Young moduli \(E_{1}\) and \(E_{2}\) along the two orthogonal directions, shear modulus \(G_{12}\) and Poisson ratio \(\nu _{12})\) are the same as those proposed for the characterization of the M1 model.

Fig. 8
figure 8

M2 model: geometrical and mechanical schemes

The RC frame at the boundary was modelled as the one included in the M1 model in terms of geometry and properties of concrete and steel rebars. The distance between the infill and the surrounding frame beam elements, which are positioned at the centrelines, is covered by means of null weight rigid links. The latter have the sole function of transmitting the interface forces. A similar approach is also proposed in Doudoumis (2007). Interface elements are placed between shell contour nodes and rigid link ends and are modelled using multilinear elastic link elements having only axial stiffness, no tensile strength and a constitutive law that is assumed to be elastic in compression. As mentioned above the interface elements are used to simulate the mortar joints. Taking into account the high manufacturing variability affecting these mortar joints, the conventional elastic Young modulus \(E_{m} =3{,}000\,\mathrm{MPa}\) was set, and the conventional mortar joint thickness \(h_{m} =20\,\mathrm{mm}\) was assigned. Also considering-that under lateral loads the frame–infill contact lengths are strongly reduced and mortar joints are affected by significant damage, frictional effects were not included in the model (different studies (e.g. Asteris 2008) show that friction arising in interfaces is not decisive for the overall response).

It is generally accepted after different numerical tests (e.g. Fiore et al. 2012; Asteris 2008) that friction does not modify the overall response of an infilled frame.

Nevertheless friction can modify the local response in the sense of a reduction of the stresses normal to the contact surface frame–infill. This produces also a reduction of the shear stresses on members. The Coulomb law is commonly used for the friction, meaning that the friction stresses can be considered proportional to the stresses normal to the contact frame–infill surface. The using of this approach requests the definition of a proportionality factor (the friction coefficient m) but it is not simply to fix a realistic value of it. For example in Papia et al. (2003) and in Saneinejad and Hobbs (1995) the value 0.45 has been assigned for the friction coefficient without an experimental evidence while in Fiore et al. (2012) a parametric study has been preferred and carried out assigning values in the range 0–0.4. Further the friction phenomenon is not simply controllable in the case of cyclic loading: it can undergo a strongly variation with the increasing of the numbers of cycles. In this conditions, considering that (a) it does not influence the overall behaviour of the system, (b) it produces a reduction of the shear stresses on beams and columns, (c) it progressively varies in the case of cyclic loading, it is reasonable to neglect it in the assessment of the local shear effect on frame members.

Nonlinearity of shell elements was introduced in the model by iteratively scaling (i.e. reducing) their thickness. The reduced thickness ideally represents that one allowing to obtain for the M2 model the same lateral secant stiffness as exhibited by the M1 model for a fixed interstorey drift level. This way the simple M1 model permits one to calibrate the M2 model at each selected prescribed displacement basing on a nonlinear law assumed for the equivalent strut.

The so defined M2 model furnishes more detailed results regarding frame internal force modification due to the frame–infill interaction, being able to simulate both interface detachment and local shear effects on RC member ends, unlike the M1 model, able to simulate the overall behaviour but not the distribution of the internal forces in the frame members.

2.3 Reliability of M1 and M2 models

Both M1 and M2 models are characterized by non linear frame members whose nonlinearity depends on the possibility of activation of plastic hinges in the critical regions. Considered that the M1 model reproduces infill by an equivalent nonlinear diagonal strut and M2 model reproduces infill by means of linear Finite Shell Elements, the reliability of the M2 nonlinear model is obtained by a calibration basing on the response of the M1 nonlinear model at each assigned drift. On the other hand the M1 nonlinear model is calibrated basing on experimental tests. Therefore M2 model, because of the calibration criterion adopted, reproduces the nonlinear behaviour of infilled frames.

The M2 model is calibrated by equating its secant stiffness and the M1 model secant stiffness at each assigned drift. In this way, as schematically shown in Fig. 9, the M2 model can follow the response of the M1 model. This is possible assuming each time different mechanical parameters. In this case, considering that the nonlinearity of the members is obtained by plastic hinges at the critical regions fixed as a functions of the cross sections characteristics, the equivalence is obtained only by varying the thickness of the infill that is modelled at each stage as a linear material.

Fig. 9
figure 9

Theoretical representation of three states of the M2 model (points A, B, C) in the lateral force–drift curve compared to the response of the M1 model and the experimental response

The definition of the infill nonlinearities of the refined M2 model, carried out by a comparison with the M1 model, has great advantages. In fact infill is generally a non homogeneous material whose nonlinear behaviour depends on a number of parameters whose identification requests a non negligible effort (e.g. Stavridis and Shing 2010). Conversely the behaviour of an equivalent nonlinear strut can be defined depending on a minor numbers of parameters more simply identifiable by observing experimental responses.

For what above the reliability of the M2 model depends on the reliability of the M1 model whose characteristics has been discussed in previous Sect. 2.1. M1 model has been formulated on the basis of different experimental results available in the literature. As an example in Fig. 10 the cyclic responses of two frames infilled with clay masonry, obtained by the authors and partially discussed in Cavaleri et al. (2014), used for the calibration of the M1 model, are shown. Also a comparison of the envelopes of strengths with the M1 model is inserted in Fig. 11 proving the reliability of the model M1 itself. To the same conclusions one can arrive by a comparison with the experimental results in Koutromanos et al. (2011) (see Fig. 12), Korkmaz et al. (2010) and Chiou et al. (1999).

Fig. 10
figure 10

Experimental responses of infilled frames (Cavaleri et al. 2014)

Fig. 11
figure 11

Experimental strength envelopes of infilled frames compared to analytical one obtained by assigning the strut M1 model (Cavaleri and Di Trapani 2014)

Fig. 12
figure 12

Experimental response of an infilled frame (Koutromanos et al. 2011) compared to the analytical envelope obtained by assigning the strut M1 model

The approach above described uniformly spreads the damage in the infill but this fact does not contrast the reliability of the results in fact the experimental observations in the case of cyclic loading show a wide diffusion of the damage (see Fig. 10) further the damage does not change the influence of the ineffective infill volumes, if any.

3 Parametric study

As discussed in the previous section, the comparability of the two-models used here is possible, under monotonic loading, when they exhibit the same stiffness at a generically assigned interstorey drift. Therefore the procedure used to evaluate internal force modification due to the presence of infill panels follows the steps shown above: (a) assignment of the mechanical properties and geometry of the infilled frame; (b) definition of the equivalent strut (M1 model); (c) definition of the M2 model in which the thickness \((t)\) of the infill is initially set equal to the real thickness; (d) choice of an interstorey drift \((d_{r})\); (e) analysis of the M1 model by imposing the fixed interstorey drift and evaluation of secant stiffness as the parameter identifying damage level; (f) identification of the damage level in the M2 model (by reducing infill thickness) in such a way as to provide the same secant stiffness as exhibited by the M1 model; (g) evaluation of RC frame internal force distribution on the M2 model. Once the internal force distribution is evaluated for both the M1 and M2 models it is possible to correlate the level of the shear forces acting in the critical sections of the frame members (obtained by the M2 model) and the axial force in the equivalent strut.

Parametric analyses were carried out to evaluate the responses, for an assigned damage level (identified by the interstorey drift ratio), of infilled frames modelled by means of both the approaches described above. The geometrical and mechanical properties of frames and infills (elastic moduli, aspect ratio, beam element cross-sections, masonry mechanical characteristics) were varied in order to evaluate their influence on the distribution of shear forces occurring on beam and column ends in contact with infills.

The shear force in the four critical sections indicated in Fig. 13 (BNO-Beam North-West, BSE-Beam South-East, CNO-Columns North West, CSE-Columns South East) was considered. In these sections, equilibrium with forces transferred by the infill through the contact regions has to be granted, thus the shear demand is here highly concentrated.

Fig. 13
figure 13

Critical sections on RC frame

For each infilled frame considered, M1 and M2 models were generated and analyzed for the drifts fixed above. Once the structural responses were obtained the dimensionless quantities reported below were evaluated:

$$\begin{aligned} \alpha _{BNO}&= \frac{V_{BNO}^{(M_2 )} }{N_p^{(M_1 )} };\quad \alpha _{BSE} =\frac{V_{BSE}^{(M_2 )} }{N_p^{(M_1 )} }\end{aligned}$$
(19)
$$\begin{aligned} \alpha _{CNO}&= \frac{V_{CNO}^{(M_2 )} }{N_p^{(M_1 )} };\quad \alpha _{CSE} =\frac{V_{CSE}^{(M_2 )} }{N_p^{(M_1 )} } \end{aligned}$$
(20)

in which \(N_P^{\left( {M_1 } \right) }\) is the axial force on the equivalent diagonal strut evaluated in the M1 model while \(V_{BNO}^{(M_2 )}\), \(V_{BSE}^{(M_2 )}\), \(V_{CNO}^{(M_2 )}\), \(V_{CSE}^{(M_2 )}\), are the shear forces acting in the critical sections evaluated using the M2 model.

The coefficients \(\alpha _{BNO}\), \(\alpha _{BSE}\), \(\alpha _{CNO}\), \(\alpha _{CSE}\), here called shear distribution coefficients, define the relationship existing between the shear forces acting on the frame critical sections and the axial force acting on the equivalent strut for a fixed interstorey drift ratio. If prediction of shear distribution coefficients is possible a priori as a function of the geometrical and mechanical variables of the infilled frame system, these coefficients become a useful tool to evaluate the real shear forces on frame sections as a quota of the equivalent strut axial force. In Fig. 14, a qualitative comparison in terms of deformed shapes and distribution of shear demand between responses exhibited by the two models for the same interstorey drift is reported, evidencing the relevance of local shear effects detected in the contact regions by the M2 model and not by the M1 model.

Fig. 14
figure 14

Comparison between M1 and M2 model responses: a deformed shape; b shear distribution

Since shear distribution coefficients can be defined at each interstorey drift reached by an infilled frame, a sensitivity analysis for different classes of infilled frames was primarily performed with an increase in the drift level from the elastic phase \((d_{r} =0.01{-}0.03\,\%)\) up to \(d_{r} =1.2\,\%\) which for most non-ductile structural systems represents a near-collapse condition.

It is not easy to identify with a single parameter a class of infilled frame systems because a really wide quantity of variables is involved and the behaviour of each system depends not so much on the single mechanical properties of RC frame and masonry infills but more on their ratios. It is also important to underline that, since the analyses were carried out in a nonlinear field, parameters that usually are not significant in elastic studies, such as strengths and strength ratios, have to be taken into account. Therefore in this study the parameter \(\psi \) (Eq. 21) was considered as characterising the system; this parameter is the product of three terms that appear to be fundamental in the behaviour of an infilled frame.

$$\begin{aligned} \psi =\lambda ^{*}\xi ^{*}\,f_{v0m} \end{aligned}$$
(21)

The parameter \(\lambda ^{*}\) appearing in Eq. 21 has already been defined by Eq. 12. It carries information about the geometry of the system and the stiffness ratio between infill and frame. The term \(\xi ^{*} =M_{ RB } /M_{ RC }\), is the ratio between the flexural strengths of the upper beam \((M_{ RB })\) and the mean flexural strengths of columns \((M_{ RC })\) and is introduced since it is related to the plastic hinge formation sequence that significantly influences frame secant stiffness in the nonlinear field and therefore also the shear distribution coefficient trend. Since the resisting moment of the column does not have a univocal value but depends on the axial force, the term \(\xi ^{*}\) can be more simply estimated, as was done in this case, by calculating the ratio \(h_{b} /h_{c}\) between the beam and column cross-section heights. Finally, \(f_{v0m}\) is the medium shear strength to be attributed to the masonry used for the infill. This medium shear strength plays a significant role because the forces that are transferred from the infill panel to the RC frame are strongly related to the panel strength.

In Figs. 15, 16, 17 and 18 the results of the previously mentioned sensitivity analyses are shown. In detail the shear distribution coefficients are shown for different values of the \(\psi \) factor and for infilled frames having aspect ratios \(\ell /h=1\) and \(\ell /h=2\). From observation of the curves it appears evident that the shear distribution coefficients maintain a sub-horizontal trend after an unstable stage which is limited to low drift values. This trend occurs for shear distribution coefficients of both the beam and column critical sections and for the two aspect ratios of the infill considered. Another characteristic of the shear distribution coefficients is that they assume the highest values when systems are characterized by low values of the \(\psi \) factor. This trend is explained by the fact that low values of the \(\psi \) factor are generally associated with weak infills combined with RC frames having significant stiffness. These conditions produce a reduction in the axial force \(N_{p}\) in the equivalent strut appearing in Eqs. 1921 and the correlated growth of the \(\alpha \) coefficients. In Tables 2 and 3 the characteristics of the specimens modelled for obtaining the curves \(\alpha -d_{r}\) are included.

Fig. 15
figure 15

Shear distribution coefficients \(\alpha _\mathrm{CNO}\) and \(\alpha _\mathrm{CSE}\) versus drift ratio for different \(\psi \) values and \(\ell /h=1\)

Fig. 16
figure 16

Shear distribution coefficients \(\alpha _\mathrm{BNO}\) and \(\alpha _\mathrm{BSE}\) versus drift ratio for different \(\psi \) values and \(\ell /h=1\)

Fig. 17
figure 17

Shear distribution coefficients \(\alpha _\mathrm{CNO}\) and \(\alpha _\mathrm{CSE}\) versus drift ratio for different \(\psi \) values and \(\ell /h=2\)

Fig. 18
figure 18

Shear distribution coefficients \(\alpha _\mathrm{BNO}\) and \(\alpha _\mathrm{BSE}\) verus drift ratio for different \(\psi \) values and \(\ell /h=2\)

Since this study aims to provide the basis for a predictive general instrument able to estimate a reliable shear demand in critical sections a relationship was sought between the shear distribution coefficients and geometrical/mechanical features of the infilled frame summarized by the \(\psi \) factor. A further parametric analysis correlating \(\alpha \) coefficients with \(\psi \) factors was therefore performed.

As previously observed, the \(\upalpha \) coefficients are almost drift independent after a certain drift level (typically a low value) is reached. Hence it is possible to choose a single interstorey drift value whose corresponding \(\upalpha \) coefficients can be considered representative of the frame–infill interaction for each value of the interstorey drift. In order to obtain the previously mentioned \(\upalpha -\uppsi \) correlation, the intermediate drift value \(\hbox {d}_\mathrm{r}=0.6\) % was selected as a reference. Two sets of models having different infill aspect ratios (\(\ell /h=1.0\) and \(\ell /h=2.0)\) were analyzed. In different cases the above models were characterized by the same or similar values of the parameter \(\psi \) in order to verify that similar values of this parameter produce similar effects in terms of coefficients \(\alpha _{BNO} , \alpha _{BSE} , \alpha _{CNO} , \alpha _{CSE}\). The results of the analyses in terms of relationships between the \(\uppsi \) factor and the coefficients \(\alpha _{BNO} ,\,\alpha _{BSE} ,\,\alpha _{CNO} ,\, \alpha _{CSE}.\) are synthetically reported in Figs. 19 and 20. The points in Figs. 19 and 20 refer to some of the infilled frames analyzed—in different cases characterized by the same value of \(\psi \) just as a prove that similar values of \(\psi \) generate similar values of the coefficients \(\alpha _\mathrm{BNO}\), \(\alpha _\mathrm{BSE}\), \(\alpha _\mathrm{CNO}\), \(\alpha _\mathrm{CSE}\). The points represented in Figs. 19 and 20 refer to infilled frames whose geometrical and mechanical features are indicated in Tables 4 and 5 together with the terms \(\lambda ^{*}\), \(\psi \) and \(w\).

Fig. 19
figure 19

Shear distribution coefficients \(\alpha _\mathrm{CNO}\) and \(\alpha _\mathrm{CSE}\) versus \(\psi \) factor at \(\ell /h=1\) and \(\ell /h=2\). Numerical analysis results and interpolating functions

Fig. 20
figure 20

Shear distribution coefficients \(\alpha _\mathrm{BNO}\) and \(\alpha _\mathrm{BSE}\) versus \(\psi \) factor at \(\ell /h=1\) and \(\ell /h=2\). Numerical analysis results and interpolating functions

Table 2 Characteristics of the specimens producing the results in Figs. 15 and 16
Table 3 Characteristics of the specimens producing the results in Figs. 17 and 18

Analytical best fitting functions (Eqs. 2225) have also been provided in order to show the possibility of deriving effective tools for practical applications. The determination coefficients \(R^{2}\) are also calculated to evaluate the agreement of the best fitting correlation law with the numerical results.

The laws for the \(\alpha -\psi \) relationships are shown below (including \(R^{2}\) coefficients) for \(\ell /h=1\) (Eqs. 2223) and for \(\ell /h=2\) (Eqs. 2425)

$$\begin{aligned} \alpha _{CNO}&= 0.96\,\psi ^{-0.37} (R^{2}=0.94);\quad \alpha _{CSE} =1.03\,\psi ^{-0.35} (R^{2}=0.91)\end{aligned}$$
(22)
$$\begin{aligned} \alpha _{BNO}&= 0.98\,\psi ^{-0.33} (R^{2}=0.90);\quad \alpha _{BSE} =1.03\,\psi ^{-0.32} (R^{2}=0.93)\end{aligned}$$
(23)
$$\begin{aligned} \alpha _{CNO}&= 1.05\,\psi ^{-0.36} (R^{2}=0.93);\quad \alpha _{CSE} =1.08\,\psi ^{-0.30} (R^{2}=0.90)\end{aligned}$$
(24)
$$\begin{aligned} \alpha _{BNO}&= 0.60\,\psi ^{-0.39} (R^{2}=0.88);\quad \alpha _{BSE} =0.68\,\psi ^{-0.32} (R^{2}=0.82) \end{aligned}$$
(25)

By means of the proposed laws \(\alpha \) coefficients can be evaluated for each infilled frame system before analyses are made as a function of the \(\psi \) factor. The above coefficients can be used to correct shear forces detected in critical sections when equivalent strut models are used to perform analyses. Finally, according to Eqs. 1920 the shear value in critical sections can be evaluated by multiplying the previously calculated \(\alpha \) coefficients by the axial force resulting in the equivalent strut.

By observing the \(\alpha -\psi \) curves it appears evident, as observed before, that, for both aspect ratios considered, the \(\alpha \) coefficients undergo a reduction when the \(\psi \) values increase. This expresses the general tendency of RC frames to receive shear forces on critical sections that increase as the stiffness of the frame increases with respect to the infill. The results also show that the influence of the infill aspect ratio \((\ell /h)\) has a major role, especially for beams that are affected by significantly lower shear when the horizontal dimension of the panel \(\ell \) prevails over the height \(h\).

Table 4 Characteristics of the specimens producing the results included in Figs. 19 and 20\(\ell /\hbox {h}=1\)
Table 5 Characteristics of the specimens producing the results included in Figs. 19 and 20\(\ell /\hbox {h}=2\)

The results of the analyses reported above can be a basis for assessment of the capacity of RC members of infilled frames when linear or nonlinear analyses are performed by means of equivalent concentric strut models. In practical applications, once the analysis is performed and the axial forces acting on the equivalent struts are known, the shear demand to consider for capacity assessment can be estimated by replacing shear forces on critical sections with the values \(V_{BNO},\, V_{BSE},\, V_{CNO} ,\, V_{CSE}\) that can be calculated by means of the following expressions:

$$\begin{aligned} V_{BNO}&= V_0 +\alpha _{BNO} N_P ;\quad V_{BSE} =V_0 +\alpha _{BSE} N_P\end{aligned}$$
(26)
$$\begin{aligned} V_{CNO}&= \alpha _{CNO} N_P ;\quad V_{CSE} =\alpha _{CSE} N_P \end{aligned}$$
(27)

\(V_{0}\) being the shear force due to the vertical loads on the beams and \(N_{p}\) the axial force in the equivalent strut.

4 Extensibility of the laws expressed by Eqs. 2225

Considering that the laws in question, correlating the coefficients for the right estimation of the shear in the frame members, were obtained for a drift of 0.6 %, it is natural to want to verify the extensibility of these laws to different drifts that can be experienced by frame–infill systems.

In this section an application is proposed to two cases of infilled frame having aspect ratios \(\ell /h=1\) and \(\ell /h=2\) respectively.

The response in terms of shear demand in the critical section is evaluated for different drift levels using the M2 model and is assumed to be exact. The shear distribution is calculated by means of the M1 model and corrected by using the laws in Eqs. 2225, also for drifts different from 0.6 % (lower and higher). Finally, the exact demand (M2 model) and the demand corrected by the proposed law (M1 model) are compared. For the sake of simplicity the term \(V_{0}\) related to vertical loads is considered null in this example. The geometrical and mechanical characteristics of the models are reported in Table 6 within the \(\psi \) factors and the related shear distribution coefficients calculated by Eqs. 2225.

Table 6 Geometrical and mechanical characteristics of models used for validation tests

The results of the tests are shown in Figs. 21 and 22 in terms of shear on critical sections versus interstorey drifts.

Fig. 21
figure 21

Comparison of the predictive capacity of shear forces on column critical sections in the M1 Model and proposed method with respect to the M2 Model for two numerical specimens characterized by \(\ell /\hbox {h}=1\) and \(\ell /\hbox {h}=2\)

Fig. 22
figure 22

Comparison of the predictive capacity of shear forces on beam critical sections in the M1 Model and proposed method with respect to the M2 Model for two numerical specimens characterized by \(\ell /\hbox {h}=1\) and \(\ell /\hbox {h}=2\)

It appears evident that although the proposed strategy is based on shear distribution coefficients evaluated at \(d_{r} =0.6\,\%\), the resulting predictive capacity at each drift is quite reliable. Prediction errors for the drift levels considered are in most cases acceptable. Figures 21 and 22 also show the level of shear obtainable by the procedure proposed by FEMA. It can be observed that this level of shear agrees conservatively with the maximum level of shear obtainable varying the drift. This result validates the procedure proposed by FEMA but confirms that the shear demand in the frame members may be lower, resulting in a lower effort in the measures to be implemented to obtain a fixed safety level.

5 Conclusions

In the present paper a study of the local shear effects produced at the ends of beams and columns of non-ductile RC infilled frames in the presence of lateral loads has been presented. This study has the aim of providing strategies for correcting the results in terms of shear demand obtained when, for the modelling, an infill is substituted with an equivalent concentric strut.

A comparison has been carried out between the force arising in the frame members in the case of an infill modelled as an equivalent concentric strut and in the case of an infill “exactly” modelled by finite shell elements, at different drift levels, for a single infilled frame. The comparison was repeated varying the geometrical and mechanical characteristics of the frame–infill system and a correlation law between a parameter synthesizing the characteristics of frame and infill and the real shear distribution in the critical sections was derived. This law allows one to express the local shear forces acting on beam and column ends as a fraction of the axial load experienced by the equivalent strut and for this reason it can be considered a basis for a predictive tool to be used for the assessment of shear demand on RC member critical sections that is otherwise undetectable when a simple equivalent concentric strut model is used. The predictive capacity of the correlation proposed was tested on two numerical specimens having two different aspect ratios, demonstrating good accuracy for all investigated drifts. Further, a comparison was made with the shear demand assessment proposed by FEMA, confirming on one hand the reliability of the approach proposed (a light underestimation of the model proposed in FEMA for the shear demand in the columns in the case of rectangular infills is not really significant) and on the other one the possibility of an overestimation of the FEMA approach for drifts lower than those for which the equivalent strut is affected by a force equal to its resistance.

The proposed correlation is obtained considering mechanical properties and structure configurations representative of RC frames designed to resist vertical loads only, but the study can be improved by including a wider class of infilled frames. However, it reveals that more accurate assessment of local shear effects is achievable even if detailed and onerous models are not used to perform analyses. Further, instruments supplementing technical codes which do not provide any predictive strategy for the evaluation of local frame–infill interaction effects or give very conservative approaches can be formulated.