1 Introduction

The separation of CO2 and N2 from CH4 containing gas mixtures is an essential step in many industrial applications such as upgrading wellhead natural gas to pipeline gas specifications (Watson et al. 2011), ensuring the safe production and storage of liquefied natural gas (LNG) (Kidnay et al. 2011), and promoting the commercialisation of sub-quality reservoirs that comprise a significant portion of the reserves world-wide (Rufford et al. 2012). In recent years, pressure swing adsorption (PSA) technology has attracted much attention for the separation of CO2 and N2 from CH4 due to its potential in lowering the separation cost (Rufford et al. 2012; Saleman et al. 2017; Xiao et al. 2016).

For a PSA separation, the mixture gas adsorption equilibrium data are essential to the design and simulation of the process. However, there are limited literature data for experimental mixture gas adsorption equilibrium because the measurement of such data is still one of the most challenging experiments in adsorption research (Walton and Sholl 2015). Instead, multicomponent adsorption data used for design or simulation are often predictions from various models based only on pure component adsorption experiments. The ideal adsorbed solution theory (IAST) developed by Myers and Prausnitz (1965) is the most widely used and a generally reliable method for predicting mixture adsorption using only pure component adsorption isotherms (Walton and Sholl 2015). The fundamental assumption of the IAST theory is that the adsorbed phase is an ideal solution which requires adsorbed molecules to have similar affinities for the adsorbent (Talu 2013; Myers and Monson 2014). Therefore, it is generally thought that the IAST will produce large deviations between prediction and experimental data for mixtures containing molecules with significant variations in polarity and adsorption affinity, and for adsorbents, such as zeolites, involving heterogeneous surfaces (Walton and Sholl 2015). Such deviations of prediction from reality lead to unnecessary uncertainties in the design and simulation of adsorption processes.

In fact, multicomponent adsorption equilibria can be quickly and reliably measured using a dynamic column breakthrough (DCB) apparatus such as the one described by Hofman et al. (2012) and Saleman et al. (2013). In this technique, adsorbate gases flow, in known ratios, through a column packed with an adsorbent material. Through the knowledge of the gas feed flow rate and composition, adsorption column pressure and temperature, and effluent composition and flow rate, the amount of gas accumulated in the column can be calculated, from which the equilibrium adsorption capacity can be determined (Saleman et al. 2013; Delgado et al. 2006, 2007; Rufford et al. 2013). An advantage of the dynamic breakthrough technique is that this method is inherently capable of measuring adsorption equilibria for gas mixtures without any modifications or additional assumptions in the analysis; this allows rapid characterisation of adsorption isotherms over a wide range of temperatures and pressures, including sub-ambient pressures through dilution of the adsorbate with an inert gas.

In this work, the dynamic column breakthrough technique was used to measure the adsorption equilibria of pure, binary and ternary mixtures of CO2, N2 and CH4 on zeolite 13X APG-III which is a commercially available adsorbent developed for the removal of CO2 in cryogenic O2 plants and studied for the removal of CO2 from flue gases using pressure swing adsorption processes (Xiao et al. 2012). Results for this particular adsorbent have not been reported for natural gas separations although data for other forms of zeolite 13X have been measured in the context of separating CO2 and N2 from natural gas (Wang 2012a; b; Cavenati et al. 2004, 2006). Given the higher CO2 capacity of zeolite 13X APG-III than other versions of zeolite 13X, it might as well be used for the separation of CO2 and N2 from natural gas. Therefore, its adsorption capacity for N2, CH4 and CO2, especially for binary and ternary mixtures, needs to be understood to assess the performance of APG-III for adsorption processes. Thus, the adsorption equilibria of pure, binary and ternary mixtures were measured at temperatures from (273 to 333 K) and pressures from (25 to 900 kPa). The pure gas equilibrium data were represented with the Toth isotherm model and the binary and ternary equilibrium data were compared with the IAST predictions to examine the ability of this model to represent this system.

2 Experimental section

2.1 Materials

Commercial zeolite 13X, UOP MOLSIV™ APG-III, was used in this study. This adsorbent was provided in the form of spherical beads with an average particle diameter of 1.9 mm and a BET surface area of 546 m2/g measured with nitrogen at 77 K. The skeletal density of the adsorbent was 2346 kg m−3 measured using a helium Pycnometer. All gases used in this work were supplied by BOC (Australia) with the following stated mole fraction purities: He—99.999%, CH4—99.995%, CO2—99.995% and N2—99.999%.

2.2 Apparatus and procedure

Pure gas and binary gas mixture adsorption equilibrium capacities were all measured using the same dynamic column breakthrough apparatus and procedure reported previously (Saleman et al. 2013, 2017; Hofman et al. 2012). Ternary gas mixture adsorption data were measured using the same apparatus but modified with an additional gas inlet line as indicated by the red dashed line in Fig. 1. The cylindrical stainless steel adsorption column, with a length of 130 mm and an internal diameter of 22.2 mm, was packed with 31.761 g of activated zeolite 13X APG-III beads. The activation of the adsorbent was carried out stepwise in a vacuum autoclave: the adsorbent was first heated to 120 °C and held at this temperature under vacuum for 2 h; then the temperature was increased to 200 °C and kept at 200 °C for 1 h before the temperature was increased to 350 °C and where it was held for at least 8 h. The adsorbent was then cooled down to about 30–40 °C, and the vacuum autoclave was filled with helium to about 1 atm pressure. After the adsorbent was packed into the adsorption column, the column was flushed with helium at room temperature until the connected outlet gas analyser reached a helium mole fraction of 1.00 after which gas adsorption measurements were commenced. Pure N2, CH4, CO2 isotherms and their binary and ternary mixtures were measured over the pressure range of (25–900 kPa) at temperatures of 273, 303 and 333 K.

Fig. 1
figure 1

The process flow schematic diagram of the dynamic column breakthrough apparatus (Saleman et al. 2017). (Color figure online)

2.3 Interpretation of adsorption data

The equilibrium adsorption capacities of gases on the adsorbent were derived via a mass balance analysis of gases entering/leaving and accumulated in the adsorption column (Saleman et al. 2013, 2017). The amount of gas flowing into and out of the adsorption column can be obtained by integrating the mass flow readings of each component gas before and after the adsorption column. The amount of gas accumulated in the adsorption column comprises gas adsorbed on the adsorbent and gas in the void volume of the bed which was measured through the displacement of helium. Therefore, this dynamic column breakthrough method measures excess adsorption capacities because the volume of helium displaced from the column is assumed to be the volume of gas in equilibrium with the adsorbed phase on the adsorbent at the end of each experiment. However, this assumption ignores the volume of the adsorbed phase which is not present when the adsorption column is filled with pure helium. The absolute adsorption capacities were then calculated from the measured excess capacities and adsorbed phase densities using Eq. 1 (Watson et al. 2009).

$${Q_{abs}}=\frac{{{Q_{ex}}}}{{1 - {\rho _{M,gas}}/{\rho _{M,ads}}}}$$
(1)

Here Q abs is the absolute adsorption capacity, Q ex is the excess adsorption capacity, ρ M,gas and ρ M,ads are the mass densities of the gas phase and adsorbed phase, respectively. The mass densities of the pure gas and mixture gases at various temperature, pressure and compositions were obtained from the software package REFPROP 9.1 (NIST 2013). For pure fluids, literature values of the adsorbed phase densities for pure compounds (\({\rho _{ads,C{O_2}}}\)= 1.170 g∙cm−3, \({\rho _{ads,C{H_4}}}\)= 0.354 g∙cm−3 and \({\rho _{ads,{N_2}}}\)= 0.701 g∙cm−3) (Watson et al. 2009; Hefti et al. 2015; Sudibandriyo et al. 2003) were used. These adsorbed phase densities were obtained using the Ono–Kondo model and assumed to be independent of pressure and temperature as pointed out by Watson et al. (2009), who also found the uncertainty in calculated densities could vary by about 10% using different methods (Sudibandriyo et al. 2003) such as Ono–Kondo, ZGR EOS, VDM covolume. For mixture gases, an ideal mixing rule was used to estimate the adsorbed phase densities. Detailed analyses of how reliable equilibrium adsorption capacities can be determined with this apparatus are provided by Hoffman et al. (2012) and Saleman et al. (2013). For brevity and convenience of discussion, the absolute adsorption capacity, Q abs , is referred as Q in equations, figures and tables in the following sections.

2.4 Measurement uncertainties

The contributing sources of measurement uncertainty in the adsorption capacities are listed in Table 1 and are as reported by Hofman et al. (2012). They identified that the most significant uncertainty source was the measurement of the difference between the flow rates entering and exiting the column. Quantification of the overall adsorption capacity measurement uncertainties can thus be achieved from the uncertainties in the total molar flow measurements for pure component measurements (Eq. 2) and the component molar flows for measurements with multicomponent mixtures (Eq. 3).

Table 1 Component uncertainties associated with DCB apparatus (Hofman et al. 2012)
$$\frac{{u\left( Q \right)}}{Q} \cong \frac{{\sqrt {u{{\left( f \right)}^2}+u{{\left( F \right)}^2}} }}{{f - F}}\;({\text{For}}\;{\text{pure}}\;{\text{fluids}})$$
(2)

Here f is the inflow, F is the average effluent flow rate from time t = 0 up to shortly after reaching steady-state and u(x) indicates the uncertainty in the quantity x.

$$\frac{{u\left( {{Q_j}} \right)}}{Q} \cong \frac{{\sqrt {u{{\left( {{f_j}} \right)}^2}+u{{\left( {{F_j}} \right)}^2}+u{{\left( {{y_j}*{F_{He}}} \right)}^2}} }}{{{f_j} - {F_j} - {y_j}*{F_{He}}}}\;({\text{For}}\;{\text{multicomponent}}\;{\text{mixtures}})$$
(3)

Here F j = y j F is the molar flow of each component. The uncertainty is estimated for each component and displayed as an error bar in each of the result plots.

3 Model description

3.1 Toth model

The Toth model was used to regress the pure component adsorption data. The Toth isotherm equation is recommended for microporous adsorbents and has been used extensively for adsorption data representation and adsorption process simulations (Valenzuela and Myers 1989). The expression of the Toth model is shown in Eq. 4.

$${Q_{abs}}={Q_{max}}\frac{{KP}}{{[{{(1+{{(KP)}^n}]}^{{\raise0.7ex\hbox{$1$} \!\mathord{\left/ {\vphantom {1 n}}\right.\kern-0pt}\!\lower0.7ex\hbox{$n$}}}}}};\,K={K_0}\exp \left( {\frac{{ - \Delta H}}{{RT}}} \right)$$
(4)

where Q max , K0, ΔH, n are adjustable empirical parameters, where n is the adsorbent heterogeneity factor, ΔH is the enthalpy of adsorption, Q max is maximum equilibrium adsorption capacity and K0 is the equilibrium parameter at infinite temperature. The other standard parameters in the equation are R and T which are the ideal gas constant and the gas temperature, respectively.

3.2 Ideal adsorbed solution theory (IAST)

The ideal adsorption solution theory (IAST) proposed by Myers and Prausnitz is a thermodynamically consistent approach to predicting multicomponent adsorption equilibria based on pure component isotherms (Myers and Prausnitz 1965). This theory was developed with an assumption among others that the spreading pressures of the components must be equal at constant temperature, where the spreading pressure (π) for a single component can be calculated from the Gibbs adsorption isotherm as follows (Thomas and Crittenden 1998):

$$\pi =RT\mathop \smallint \limits_{0}^{{p_{i}^{0}}} \left( {n_{i}^{0}/A} \right){\text{d}}lnP$$
(5)

Thus, the condition π mix  = π i  = π j = …= π N must be fulfilled to meet the IAST requirement for a mixture composed of N (number of species in the mixture) components, which leads to the following expression:

$$\pi A/RT=\mathop \smallint \limits_{0}^{{p_{i}^{0}}} \frac{{n_{i}^{0}}}{{{p_i}}}d{p_i}=\mathop \smallint \limits_{0}^{{p_{j}^{0}}} \frac{{n_{j}^{0}}}{{{p_j}}}d{p_j}= \ldots =\mathop \smallint \limits_{0}^{{p_{N}^{0}}} \frac{{n_{N}^{0}}}{{{p_N}}}d{p_N}$$
(6)

where \(p_{i}^{0}\) is the hypothetical equilibrium gas phase pressure exerted by the respective pure component i, over area A, when it has the same temperature and spreading pressure (π mix ) of the adsorbed phase in a mixture system, \(n_{i}^{0}\) is the corresponding capacity for the pure component i, and p i is the gas phase pressure exerted by component i in the mixture, which can be expressed as \({p_i}=p_{i}^{0}\left( \pi \right){x_i}\) with x i being the mole fraction of i in the adsorbed phase.

The p i can also be expressed as p i = y i P if the total pressure of the mixture is P and the mole fraction of i in the vapour phase is y i . Therefore, at equilibrium conditions for a component i in a multicomponent mixture, the following equation can be obtained

$${y_i}P=p_{i}^{0}\left( \pi \right){x_i}$$
(7)

Assuming the total pressure P and mole fraction y i of component i in the vapour phase are known, then the calculation procedure for a mixture involves finding \(p_{i}^{0}\) and x i by solving Eqs. 6 and 7 simultaneously subject to the constraint \(\mathop \sum \nolimits^{} {x_i}=1\). Once values of \(p_{i}^{0}\) have been found, \(n_{i}^{0}\) can be calculated and with the x i values also known, the total adsorbed amount, n T , can be calculated using standard state loadings from the pure component isotherms

$$\frac{1}{{{n_T}}}=\mathop \sum \limits_{{i=1}}^{N} \frac{{{x_i}}}{{n_{i}^{0}}}$$
(8)

The adsorption of each species in the mixture is then calculated by

$${n_i}={x_i}{n_T}$$
(9)

4 Results and discussion

4.1 Pure component equilibria

Pure component adsorption data for N2, CH4 and CO2 on zeolite 13X APG-III in the pressure range of 25–900 kPa at three temperatures (273, 303 and 333 K) are shown in Fig. 2. The corresponding optimal regression plots using the Toth isotherm model are also shown in the figure. The deviations of the experimental data from the predicted values as a fraction of the measured data are shown in Fig. 3. The Toth model parameters determined by regression with their associated statistical uncertainties are presented in Table 2. As seen from the plots, the pure gas adsorption data could be well represented by the Toth isotherm model, with a standard deviation of 0.004 mmol/g for N2, 0.004 mmol/g for CH4 and 0.02 mmol/g for CO2, which are all within the experimental uncertainties for these measurements. In addition, all the Toth model parameters were obtained with small statistical uncertainties except for the K0 parameter for CO2, for which the uncertainty was larger than the parameter value; this was caused by the fact that there were fewer measurements made in the low pressure range to adequately cover the large variation in the adsorption capacity of CO2 that occurs for a relatively small change in pressure.

Fig. 2
figure 2

Experimental data and regressed Toth isotherms for a N2, b CH4 and, c CO2

Fig. 3
figure 3

Relative deviation plots of pure component experimental data from regressed Toth models: a N2, b CH4 and c CO2

Table 2 Toth isotherm parameters regressed to data measured across three isotherms (273, 303 and 333 K)

The equilibrium adsorption amount of each component increased with pressure at constant temperature; however, the initial increase of CO2 adsorption at low pressure (< 100 kPa) region was more prominent than the increases for N2 and CH4. At all temperatures, the measured equilibrium capacity of CO2 was higher than that of N2 and CH4 for the same pressure because of the stronger polarizability of CO2 compared to CH4 and N2 (Mulgundmath et al. 2012). For N2, the maximum adsorption capacity measured at 273 K was 2.03 mmol/g at a pressure of 902 kPa, and capacities with the same pressure at 303 and 333 K were 1.48 and 1.16 mmol/g, respectively. For CH4, the maximum adsorption capacity measured at 273 K was 2.9 mmol/g at a pressure of 903 kPa, and the corresponding capacities for the same pressure at 303 and 333 K were 2.34 and 1.85 mmol/g, respectively. For CO2, the maximum adsorption capacity measured at 273 K was 5.83 mmol/g at a pressure of 891 kPa, and the corresponding capacities for the same pressure at 303 and 333 K were 5.18 and 4.65 mmol/g, respectively. The experimental data were found to be consistent with exsisting literature data (Wang 2012; Cavenati et al. 2004, 2006).

Following a review of the published data on Zeolite 13X, three additional recent data sets measured under relatively similar experimental conditions have been plotted for comparison. These data are from Mofarahi and Shokroo (2013) (N2), McEwan et al. (2013) (CO2), and Saleman et al. (2017) (CH4 and N2). The published data are in very good agreement with the present measurements.

4.2 Binary gas mixture adsorption equilibria

Binary adsorption equilibria were measured for three different binary gas mixtures, namely CO2 + N2, CO2 + CH4 and CH4 + N2. The experiments were conducted over three temperatures (273, 303 and 333 K), each with two overall system pressures (100 and 900 kPa), incorporating three combinations of mixture composition (25/75%, 50/50% and 75/25%). This resulted in 18 experiments for each binary mixture and a total of 54 binary experiments which are tabulated in Tables 3, 4 and 5. To check the thermodynamic consistency of the pure gas results with the binary adsorption data and the internal consistency of the binary data, consistency tests were carried out for each of the three pairs (CO2  +  N2, CO2  +  CH4, and CH4  +  N2) of binary experiments using the data obtained at the temperature of 273 K with the method suggested by Sircar et al. (Rao and Sircar 1999). A brief introduction of the equations used for the consistency tests and the results of comparison are given in the Supporting Information. These binary experimental data are also plotted in Fig. 4 (CO2 + CH4 and CO2 + N2) and Fig. 6 (CH4 + N2) along with adsorption predictions from the IAST implemented using the algorithm of Valenzuela and Myers (1989), with Toth isotherm parameters obtained from the pure component adsorption equilibria. It can be seen that the affinity of CO2 towards Zeolite 13X is much higher than those of CH4 and N2. This translates to a non-uniform site energy distribution for binary mixtures containing CO2, which can be represented by a quasi-IAST isotherm for the mixture based on the Toth function (Kumar et al. 2011). For CO2 at partial pressures above 10 kPa, the adsorption on Zeolite 13X can be represented within experimental uncertainty from the partial pressure alone using the quasi-IAST isotherm. The deviations between the experimental data and the predictions from the IAST model as a percentage of the experimental values are shown in Fig. 5 (CO2 + CH4 and CO2 + N2) and Fig. 7 (CH4 + N2). Zeolite 13X has an extremely strong affinity towards CO2 compared to CH4 or N2 as can be seen in the values of equilibrium selectivity shown in Tables 3 and 4. Selectivity was calculated based on the following formula for carbon dioxide over methane:

Table 3 CH4 + CO2 binary mixture adsorption capacity data
Table 4 N2 + CO2 binary mixture adsorption capacity data
Table 5 CH4 + N2 binary mixture adsorption capacity data
Fig. 4
figure 4

Adsorption capacity and IAST (Toth) prediction at 333, 303 and 273 K for a CO2 + CH4 and b CO2 + N2 binary gas mixture. IAST predictions for CH4 and N2 in their binary mixtures with CO2 are not shown due to the neglibigle amount of adsorption

Fig. 5
figure 5

Deviation plots of CO2 experimental data from IAST (Toth) model as a % of experimental data at 333, 303 and 273K for a (CO2 + CH4) and b (CO2 + N2) binary gas mixtures. Deviation data for CH4 and N2 are not plotted due to the negligible amount of adsorption measured in the presence of CO2

Fig. 6
figure 6

Adsorption Capacity at 333, 303 and 273 K for CH4 + N2 binary gas mixture, showing pure component isotherm data as dashed lines

Fig. 7
figure 7

Deviation plot of experimental data from IAST (Toth) model as a % of experimental data at 333, 303 and 273 K for (CH4 + N2)

$${\varvec{\alpha}_{{\varvec{C}}{{\varvec{O}}_2} - {\varvec{C}}{{\varvec{H}}_4}}}=~\frac{{{{\varvec{Q}}_{{\varvec{C}}{\varvec{O}}2}}/{{\varvec{y}}_{{\varvec{C}}{\varvec{O}}2}}}}{{{{\varvec{Q}}_{{\varvec{C}}{\varvec{H}}4}}/{{\varvec{y}}_{{\varvec{C}}{\varvec{H}}4}}}}$$
(10)

Similar equations were used to evaluate the selectivity of CO2 over N2 (Table 4) and CH4 over N2 (Table 5). Figure 6 shows the adsorption observed for the CH4 + N2 binary mixture, with Fig. 7 showing the deviations of those data from the predictions of the IAST. The values of \({\varvec{\alpha}_{{\varvec{C}}{{\varvec{H}}_4} - {{\varvec{N}}_2}}}\)shown in Table 5 are similar with the literature values for other common adsorbents such as activated carbon (Rufford et al. 2013).

From Figs. 5 and 7, it can be seen that the IAST could provide accurate predictions of the equilibrium capacities for the binary mixture components. The root mean square deviation between the IAST predictions and the measured equilibrium adsorption capacities were 0.030 mmol/g for CO2 and 0.048 mmol/g for CH4 for the CO2 + CH4 mixture, 0.055 mmol/g for CO2 and 0.020 mmol/g for N2 for the CO2 + N2 mixture, and 0.003 mmol/g for CH4 and 0.014 mmol/g for N2 for the CH4 + N2 mixture, which were all less than the measurement uncertainties. Figure 4 also shows the competitive adsorption among CO2, CH4 and N2. The presence of CO2 reduced the CH4 adsorption capacity by 98% in the binary gas mixtures of CO2 + CH4 (Fig. 4a) compared to pure CH4 adsorption, and the N2 adsorption capacity by 99% in the binary gas mixtures of CO2 + N2 (Figs. 4, 6b) compared to pure N2 adsorption. In binary mixtures of CH4 + N2 (Fig. 6), both gases exhibited more adsorption on zeolite 13X than in mixtures containing CO2; however, a reduction in adsorption capacity was observed for both gases (N2 by 32% and CH4 by ~ 10%) when compared to their pure fluid adsorption capacities.

In these experiments, both the feed composition (25–80%) and the total system pressure (1–9 bar) were varied for all binary gas mixtures to study the effect of gas composition on the competitive adsorption of gases at different total pressures. This is useful for verifying the performance of predictive models for competitive adsorption used to simulate dynamic PSA processes since both the total pressure and gas compositions frequently change during a cycle. It is commonly expected that at constant temperature the adsorption amount of a gas in a mixture will vary with changes in either the gas composition or the total system pressure because of competitive adsorption, even if the partial pressure of each adsorbate is held the same. However, the extent of any reduction depends on the relative affinities of the adsorbates in competition; potentially, the adsorption of higher affinity gas will only be slightly lessened by the presence of the weakly adsorbed gas. As an example, the adsorption of CO2 at a partial pressure of 25 kPa in a binary mixture of CO2 and CH4 at a total pressure of either 100 or 400 kPa was measured at 273 K. The decrease in CO2 adsorption resulting from an increase in total pressure from 100 to 400 kPa was only 3.8% despite the significant reduction in CO2 fraction from 25 to 6.25 mol%. For the CO2 and N2 mixture, the impact of such changes were even smaller with a reduction in CO2 adsorption at constant partial pressure of only 1.5%. In contrast, the four-fold reduction in CO2 mole fraction and four-fold increase in system pressure resulted in an increase the adsorption of both CH4 and N2 by a factor of about 3.8.

The spreading pressures extrapolated during the IAST calculations for CH4 in binary mixture of CH4–CO2 was ~ 13,000 kPa, whilst the corresponding spreading pressure for N2 in a N2–CO2 mixture was ~ 15,000 kPa. These exceedingly high spreading pressures were not covered by the pure component isotherm measurements and are thus a concern for the validity of using IAST to predict mixture gas adsorption. However, the reasonable agreement between the binary data and the IAST model in this work showed that the extrapolation of spreading pressure did not affect the predictive capability of the IAST model.

4.3 Ternary experiments with CO2, N2 & CH4 gas mixture

The ternary adsorption equilibria were measured for ternary mixtures of N2 + CH4 + CO2 prepared by flow, where the ratio of N2–CH4 was always approximately 1:1, while the approximate CO2 mole fraction was either 0.8, 0.6 or 0.4. These experiments were conducted at three temperature (273, 303 and 333 K) and three overall system pressures around (100, 500 and 900 kPa). The results of these 27 ternary experiments with measurement uncertainties are listed in Table 6 and plotted in Fig. 8 along with the regressed Toth model for pure CO2 at the corresponding temperatures/partial pressures and IAST predictions for the mixtures based on pure component Toth model parameters.

Table 6 Ternary mixture adsorption capacity data
Fig. 8
figure 8

Adsorption capacities for ternary gas mixture of (CH4 + N2 + CO2) and isotherm model predictions for pure components and the same components in gas mixtures showing the impact of CO2 on the adsorption capacity of methane and nitrogen

Comparison of equilibrium adsorption amounts in the ternary mixtures with those predicted for the pure gas adsorption isotherms (Fig. 8) reveals that the CO2 equilibrium adsorption capacity was not affected by the presence of either methane or nitrogen in a ternary gas mixture while in contrast the CH4 and N2 adsorption amounts were significantly suppressed in the mixture. To be specific, an exemplar comparison is made for the adsorption at a temperature of 273 K and a total pressure of 902 kPa. At the equivalent partial pressure of 250 kPa, the adsorption capacity of N2 was reduced from 1.12 mmol/g for the pure gas to 0.02 mmol/g in a ternary mixture of 28% N2 + 37% CH4 + 35% CO2. Similarly the adsorption capacity of CH4 at this partial pressure was reduced from 1.87 mmol/g for the pure gas to 0.13 mmol/g in a ternary mixture of 18% N2 + 27% CH4 + 55% CO2 as shown in Fig. 8. In contrast, the sorption of CO2 in the mixture at a partial pressure of ~ 500 kPa in the ternary gas mixture of 28% N2 + 18% CH4 + 55% CO2 was the same within the measurement uncertainty as its adsorption capacity for the pure fluid at the same partial pressure at 5.7 mmol/g. Figure 9 shows a deviation plot for the difference between the measured data and the IAST (Toth) model predictions as a percentage of the measured data. The data confirm that the IAST (Toth) model predicts the measured CO2 sorption values with reasonable accuracy and is therefore a representative model for the ternary gas mixture data. The deviations for CH4 and N2 are not plotted due to the negligible measured adsorption in the presence of CO2.

Fig. 9
figure 9

Deviation plot of IAST and experimental data for CO2 + CH4 + N2 ternary mixture as a percentage of the experimental value at three different temperatures, 333, 303 and 273 K

5 Conclusion

Knowledge of mixture gas adsorption equilibrium data is critical to the design and simulation of adsorption based processes. In this paper adsorption data of pure CO2, CH4 and N2 on zeolite 13X APG-III were measured at different pressures in the range of 25–900 kPa and three different temperatures (273, 303 and 333 K). The CO2 adsorption amount was much higher than that of N2 and CH4 at the conditions measured. The pure gas adsorption data could be well described using a Toth isotherm model with parameters obtained by regression of the data. Experimental binary and ternary adsorption equilibria data were also measured for mixtures of CO2, CH4 and N2 in the same temperature and pressure range, and compared to IAST predictions based on the Toth model parameters determined from the pure gas adsorption data. The IAST predictions of mixture gas adsorption could represent the binary and ternary adsorption equilibria well with corresponding maximum deviations being 0.055 and 0.3 mmol/g, respectively, indicating the IAST predictions of CO2, CH4 and N2 mixture gas adsorption on zeolite 13X are robust and that the IAST can be reliably used for process design calculations using this adsorbent.