Abstract
Electrocardiogram (ECG) acquisition is still a challenge as gradient artefacts superimposed on the electrophysiological signal can only be partially removed. The signal shape of theses artefacts can be similar to the QRS-complex, causing possible misinterpretation during patient monitoring and false triggering/gating of the MRI. For their real-time suppression, an adaptive filter is proposed. The adaptive filter is based on the noise-canceller configuration with LMS coefficient updates. The references of the noise canceller are the three gradient signals that are acquired simultaneously with the noisy ECG. Tests were done on patients, on volunteers and using an MR-safe ECG simulator. The noise canceller’s performance was measured offline, simulating real-time processing by point-by-point operations. To create worst-case scenarios, clinical sequences with strong- and fast-switching gradients have been chosen. The noise-cancelling filter reduces the gradient artefacts’ peak amplitudes by 80–99% after adaptation, without changing the desired ECG signal shape. The estimated reduction of total average power of the MR gradient artefacts is 62–98%. The proposed filter is capable of reducing artefacts due to strong- and fast-switching gradients in real-time applications and worst-case situations. The quality of the ECG is sufficiently high that a standard one-lead QRS-detector can be used for gating/triggering the MRI. For permanent patient monitoring, further improvements are needed.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Fischer SE, Wickline SA, Lorenz CH (1999) Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 42:361–370
Larson G, White RD, Laub G, McVeigh ER, Li D, Simonetti OP (2004) Self-gated cardiac. Cine MRI Magn Reson Med 51:93–102
Keltner JR, Roos MS, Brakeman PR, Budinger TF (1990) Magnetohydrodynamics of blood flow. Magn Reson Med 16:139–149
Bonmassar G, Purdon PL, Jaaskelainen IP, Chiappa K, Solo V, Brown EN, Belliveau JW (2002) Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI. Neuroimage 16:1127–1141
Felblinger J, Lehman C, Boesch C (1994) Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering. Magn Reson Med 32:523–529
Lui F, Xia L, Crozier S (2003) Influence of magnetically-induced E-field on cardiac electric activity during MRI: a modelling study. Magn Reson Med 50:1180–1188
Allen PJ, Josephs O, Turner R (2000) A method for removing imaging artifact from continuous EEG recorded during functional MRI . Neuroimage 12:230–239
Sijbers J, Michiels I, Verhoye M, Van Audekerke J, Van der Linde A, Van Dyck D (1999) Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data. Magn Reson Med 17:1383–1391
Goldman RI, Stern JM, Engel J, Coen MS (2000) Acquiring simultaneous ECG and functional MRI . Clin Neurophysiol 111:1974–1980
Felblinger J, Slotboom J, Kreis B, Jung B, Boesch C (1999) Restoration of electrophysiological signal distorted by inductive effects of magnetic field gradients during MRI sequences. Magn Reson Med 41:715–721
Kreger KS, Giordano CR (1992) Biopotential adaptive filtering in an MR environment abstracts SMRM 11th Annual scientific meeting 1:661
Yuan Q, Axel L, Hernandez EH, Dougherty L, Pilla JJ, Scott CH, Ferrari VA, Blom AS (2000) Cardiac-respiratory gating method for magnetic resonance imaging of the heart. Magn Reson Med 43:314–318
Shellock FG, Kanal E, (1996) Burns associated with the use of monitoring equipment during MR procedures. J Magn Reson Imaging 6:271–272
Kugel H, Bremer C, Püschel M, Fischbach R, Lenzen H, Tombach B, Van Aken H, Heindel W (2003) Hazardous situation in the MR bore: induction in ECG leads causes fire. Eur Radiol 13:690–694
Haykin S (1996) Adaptive filter theory. Prentice-Hall, New Jersey
Widrow B, Stearns SD (1985) Adaptive signal processing. Prentice-Hall, New Jersey
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Abächerli, R., Pasquier, C., Odille, F. et al. Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates. MAGMA 18, 41–50 (2005). https://doi.org/10.1007/s10334-004-0093-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10334-004-0093-1