Bone remodelling is the process that maintains bone structure and strength through adaptation of bone tissue mechanical properties to applied loads. Bone can be modelled as a porous deformable material whose pores are filled with cells, organic material and interstitial fluid. Fluid flow is believed to play a role in the mechanotransduction of signals for bone remodelling. In this work, an osteon, the elementary unit of cortical bone, is idealized as a hollow cylinder made of a deformable porous matrix saturated with an interstitial fluid. We use Biot’s poroelasticity theory to model the mechanical behaviour of bone tissue taking into account transverse isotropic mechanical properties. A finite element poroelastic model is developed in the COMSOL Multiphysics software. Elasticity equations and Darcy’s law are implemented in this software; they are coupled through the introduction of an interaction term to obtain poroelasticity equations. Using numerical simulations, the investigation of the effect of spatial gradients of permeability or Poisson’s ratio is performed. Results are discussed for their implication on fluid flow in osteons: (i) a permeability gradient affects more the fluid pressure than the velocity profile; (ii) focusing on the fluid flow, the key element of loading is the strain rate; (iii) a Poisson’s ratio gradient affects both fluid pressure and fluid velocity. The influence of textural and mechanical properties of bone on mechanotransduction signals for bone remodelling is also discussed.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Ashman RB, Cowin SC, Van Buskirk WC and Rice JC (1984). A continuous wave technique for the measurement of the elastic properties of cortical bone. J Biomech 17: 349–361
Beno T, Yoon Y-J, Cowin SC and Fritton SP (2006). Estimation of bone permeability using accurate microstructural measurements. J Biomech 39: 2378–2387
Biot MA (1955). Theory of elasticity and consolidation for a porous anisotropic solid. J Appl Phys 26(2): 182–185
Burger EH, Klein-Nulend J and Smit TH (2003). Strain-derived canalicular fluid flow regulates osteoclast activity in a remodelling osteon–a proposal. J Biomech 36(10): 1453–1459
COMSOL Multiphysics (2005). Model library. Grenoble, France
Cowin SC (1999). Bone poroelasticity. J Biomech 32: 217–238
Cowin SC (2001). Bone mechanics handbook, 2nd edn. CRC Press, Boca Raton
Hengsberger S, Enstroem J, Peyrin F and Zysset P (2003). How is the indentation modulus of bone tissue related to its macroscopic elastic response? A validation study. J Biomech 36(10): 1503–1509
Lanyon LE (1984). Functional strain as a determinant for bone remodeling. Calcif Tissue Int 36(Suppl 1): S56–S61
Lanyon LE and Rubin CT (1984). Static vs dynamic loads as an influence on bone remodelling. J Biomech 17(12): 897–905
Manfredini P, Cocchetti G, Maier G, Redaelli A and Montevecchi FM (1999). Poroelastic finite element analysis of a bone specimen under cyclic loading. J Biomech 32(2): 135–144
Martin RB, Burr DB and Sharkey NA (1998). Skeletal tissue mechanics, 1st edn. Springer, New York
Nagatomi J, Arulanandam BP, Metzger DW, Meunier A and Bizios R (2001). Frequency- and duration-dependent effects of cyclic pressure on select bone cell functions. Tissue Eng 7(6): 717–728
Nagatomi J, Arulanandam BP, Metzger DW, Meunier A and Bizios R (2002). Effects of cyclic pressure on bone marrow cell cultures. J Biomech Eng 124(3): 308–314
Pithioux M, Lasaygues P and Chabrand P (2002). An alternative method to determine the elastic properties of cortical bone. J Biomech 35: 961–968
Qin YX, Lin W and Rubin C (2002). The pathway of bone fluid flow as defined by in vivo intramedullary pressure and streaming potential measurements. Ann Biomed Eng 30(5): 693–702
Reilly D and Burstein A (1975). The elastic and ultimate properties of compact bone tissue. J Biomech 8: 393–405
Rémond A and Naili S (2004). Cyclic loading of a transverse isotropic poroelastic cylinder: a model for the osteon. Comptes Rendus Mecanique 332(9): 759–766
Rémond A and Naili S (2005). Finite element analysis of a poroelastic model: application to an osteon under cyclic loading. Proc 4th ICCHMT II: 1080–1084
Rémond A and Naili S (2005b). Transverse isotropic poroelastic osteon model under cyclic loading. Mech Res Commun 32(6): 645–651
Shahar R, Zaslansky P, Barak M, Friesem AA, Currey JD and Weiner S (2007). Anisotropic poisson’s ratio and compression modulus of cortical bone determined by speckle interferometry. J Biomech 340: 252–264
Smit TH, Huyghe JM and Cowin SC (2002). Estimation of the poroelastic parameters of cortical bone. J Biomech 35(6): 829–835
Steck R, Niederer P and Knothe Tate ML (2000). A finite difference model of load-induced fluid displacements within bone under mechanical loading. Med Eng Phys 22(2): 117–125
Turner CH (1998). Three rules for bone adaptation to mechanical stimuli. Bone 23(5): 399–407
Turner CH, Rho J, Takano Y, Tsui TY and Pharr GM (1999). The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. J Biomech 32(4): 437–441
Wang L, Cowin SC, Weinbaum S and Fritton SP (2000). Modeling tracer transport in an osteon under cyclic loading. Ann Biomed Eng 28(10): 1200–1209
Weinbaum S, Cowin SC and Zeng Y (1994). A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses. J Biomech 27(3): 339–360
You L, Cowin SC, Schaffler MB and Weinbaum S (2001). A model for strain amplification in the actin cytoskeleton of osteocytes due to fluid drag on pericellular matrix. J Biomech 34(11): 1375–1386
You LD, Weinbaum S, Cowin SC and Schaffler MB (2004). Ultrastructure of the osteocyte process and its pericellular matrix. Anat Rec 278A(2): 505–513
Zeng Y, Cowin SC and Weinbaum S (1994). A fiber matrix model for fluid flow and streaming potentials in the canaliculi of an osteon. Ann Biomed Eng 22(3): 280–292
Zhang D and Cowin SC (1994). Oscillatory bending of a poroelastic beam. J Mech Phys Solids 42(10): 1575–1599
Zhang D, Weinbaum S and Cowin SC (1998). On the calculation of bone pore water pressure due to mechanical loading. Int J Solids Struct 35(34-35): 4981–4997
Zysset PK, Guo XE, Hoffler CE, Moore KE and Goldstein SA (1999). Elastic modulus and hardness of cortical and trabecular bone lamellae measured by nanoindentation in the human femur. J Biomech 32(10): 1005–1012
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Rémond, A., Naïli, S. & Lemaire, T. Interstitial fluid flow in the osteon with spatial gradients of mechanical properties: a finite element study. Biomech Model Mechanobiol 7, 487–495 (2008). https://doi.org/10.1007/s10237-007-0111-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10237-007-0111-0