Introduction

Mineral trioxide aggregate (MTA) has attracted considerable attention because of its excellent biocompatibility, sealing ability, and antimicrobial properties [1, 2]. Although it was initially introduced as a material for repair of root perforations [3], today it is used in vital pulp therapy [4, 5], as a root-end filling material [6], as an apical plug in open apex non-vital teeth [7, 8], for the treatment of dentine hypersensitivity [9], and in regenerative endodontic therapy [10, 11]. However, there are also some disadvantages associated with the use of MTA including long setting time, difficult handling, possibility of staining of tooth structure, and high cost [1, 12, 13]. Recently, a new calcium silicate-based restorative cement, Biodentine (Septodont, Saint Maur des Fosses, France), was introduced. It is a fast-setting restorative material recommended as a dentin substitute that can be used in the same applications as MTA [14].

An important factor for successful endodontic treatment is the sealing ability of the filling material [15]. An ideal material should provide a tight seal. The sealing ability of MTA was investigated in different leakage studies in vitro, using dye or fluid transport methods [6, 1624]. However, the microleakage of Biodentine has not been adequately evaluated.

The environment in which a material is maintained could affect the marginal adaption with dentin, the microleakage, as well as the microstructure and surface morphology of the material [2527]. It has been reported that variations in the pH of host tissues, because of pre-existing inflammation at the time of placement, could affect the physical and chemical properties of these materials [2831]. It has also been pointed out that surface hardness of MTA was impaired in an acidic environment [30]. Another study reported that MTA surfaces exhibited higher surface roughness in the presence of an acidic environment [32]. However, there are limited data about the effect of low pH on Biodentine [33].

The aim of this study was to evaluate the sealing ability of Biodentine in comparison to MTA, after exposure to an acidic environment, with the use of a fluid transport model for quantitative analysis of microleakage. In addition, scanning electron microscopy (SEM) was performed in order to investigate the morphological microstructure of the materials in the presence of an acidic environment.

Materials and methods

Specimens’ preparation

Dentin disks from anterior bovine teeth were horizontally sectioned into 3-mm-thick slices, and the canal space of each dentin slice was enlarged to 2.6 mm in diameter, using a standardized cylindrical bur in a drilling machine with standardized vertical motion. Biodentine (Septodont, Saint Maur des Fosses, France) and white ProRoot MTA (Dentsply Tulsa Dental Specialties, Memphis, TN) were prepared according to the manufacturers’ instructions and compacted into the lumen of the dentin disks, using, for Biodentine, the plastic filling instrument provided by the manufacturer and, for MTA, a BL-S Kondenser 60/120 (B&L Biotech USA, Inc.) and paper points. Twenty specimens of each material were further divided into two groups according to the storage media: group A: materials with saline (Pharmex S.A. Pharmaceuticals, Greece) as storage medium; group B: materials with citric acid buffered at pH 5.4 as storage medium. The preparation of citric acid was carried out at the Laboratory of Mineralogy, Petrology and Economic Geology, School of Mining and Metallurgical Engineering, National Technical University of Athens. The storage of the specimens was for 24 h in contact with a saline- or citric acid-soaked piece of gauze in 37 °C, before the first fluid movement measurement.

In the positive control group (n = 5), no material was used. In the negative control group (n = 5), a 3-mm-thick MTA apical plug was placed and then the entire surface was covered by two coats of nail varnish.

Fluid movement measurements

The specimens were fitted in the fluid transport device and measurements were recorded at 1, 3, 6, and 24 h and 1 or 3 months, by the method described previously by Wu et al. [18]. The root specimens were attached to a plastic tube and the connections were coated with composite resin. A second rubber tube was attached to this plastic tube, and the tube was filled with deionized water on either side of the specimen. The end of the system was connected to a 20-μL glass capillary tube 170 mm long (Haak, Waller-Graf & Co., Werlheim, Germany). All connections were closed tightly by twisting pieces of stainless steel wire. An air bubble was introduced through the open end of the glass capillary. Finally, a headspace pressure of 60 kPa (0.6 atm) was applied. The same examiner assessed visually the movement of the air bubble. The fluid movement was measured using the fluid transport model, and the fluid transport results (F, Flow) were expressed in microliter per hour and divided into three categories: (1) F = 0 μL/h (no fluid movement—NF), (2) 0 < F < 20 μL/h (slight fluid movement—SF), and (3) F > 20 μL/h (gross fluid movement—GF).

Following the assessment at 24 h, the specimens were detached from the measuring apparatus and they were kept in 37 °C and 100 % humidity between measurements.

Scanning electron microscope analysis

For the morphological evaluation, five new specimens for each group were prepared as described above and kept under the same storage conditions. The surface structural organization of each specimen was examined through a scanning electron microscopy (SEM) approach. Samples were attached on aluminum stubs wet and uncoated and were immediately analyzed in low-vacuum mode (between 1 to 30 Pa) to minimize any changes caused to the sample materials, such as stress induced by the quick loss of humidity from the samples. Low vacuum was also used to eliminate charging after the samples have dried. The scanning electron microscope is a Jeol 6380LV (JEOL Ltd., USA), which was operated at 15 kV, a working distance of 20 mm, and a beam current of about 1 nA. The specimens were examined systematically and representative images of each area were obtained.

Statistical analysis

The Kruskal-Wallis test was used to investigate the impact of each material-storage combination fluid transport values versus time assessment. Additionally, post hoc analysis with the use of Mann-Whitney U test was applied for the evaluation of the differences in transport fluid values in the different groups of the study. The Friedman test was also used for comparison between the repeated fluid transport measures. Also, post hoc analysis with the use of Wilcoxon signed rank test was performed for assessing the differences between time points. All reported probability values (p values) were compared to a significant level of 5 %. The analyses of coded data were carried out using IBM SPSS software version 21.0.

Results

Fluid movement measurements

The fluid transport results of the materials/storage combination at the different time intervals are shown in Table 1. At each time interval, NF was recorded in the negative control group, whereas in the positive control group, GF was recorded.

Table 1 Number of root sections by material-storage combination and time point

Up to the 24-h measurement, MTA stored in saline as well as in citric acid showed greater fluid transport values than Biodentine (Table 2). However, at 24 h, the difference in the fluid transport values of both materials was not statistically significant in either storage medium (Table 2).

Table 2 Fluid transport measures multiple comparisons between different material-storage combinations for each time point

At the 3-month measurement, the MTA stored in saline showed statistically significant greater ability to prevent fluid movement than Biodentine in the same storage (p < 0.0001). However, when materials were stored in an acidic environment, no statistical significant difference was found at the 3-month measurement (Table 2).

Biodentine stored in saline leaked more over time (p < 0.008), whereas the fluid movement values of MTA stored in saline were statistically significantly lower at the 3-month interval when compared to the 24-h measurement (p < 0.015) (Table 3).

Table 3 Fluid transport repeated measures multiple comparisons between time points for each material-storage combination

When the materials were stored in an acidic environment, no statistical significant differences were found regarding their ability to prevent fluid movement between the 24-h and the 3-month measurements (Table 2).

SEM analysis

Representative surfaces of freshly mixed Biodentine and MTA, as well as after storage in different environments, are shown in Fig. 1. Freshly mixed Biodentine showed small and more developed hexagonal crystal structure compared to freshly mixed MTA (Fig. 1a, c). Both materials, after storage in saline, showed an uneven crystalline surface with similar hexagonal crystals (Fig. 1b, e). MTA stored in citric acid showed similar microstructure as when stored in saline (Fig. 1c). However, Biodentine stored in citric acid showed a relatively smooth surface, which consisted of spheroidal crystals without hexagonal plates. The crystallized structure, which formed after exposure of Biodentine to citric acid, presented a cluster of globular crystalline with round-shaped structure (Fig. 1f).

Fig. 1
figure 1

Representative scanning electron micrographs of materials after storage in different environments. a Freshly mixed MTA, b MTA stored in saline, c MTA stored in citric acid, d freshly mixed Biodentine, e Biodentine stored in saline, and f Biodentine stored in citric acid

Discussion

The purpose of this study was to investigate the sealing ability, as well as the microstructure of Biodentine, in comparison to MTA, in two different environments that could mimic clinical situations. Under certain clinical applications, these materials are placed in an environment in which inflammation may be present and the surface of the unset material may be exposed to a low pH [34]. The materials were exposed to citric acid no longer than 24 h, simulating the situation in which the initiating factors of an inflammatory process are removed by proper treatment.

The methodology used in the present study was the fluid transport model, which has been shown to give reliable quantitative results for the assessment of the sealing ability of calcium silicate-based materials [2, 18]. Dentin disks from anterior bovine teeth were used, as they could be considered an appropriate substitute for human teeth in analogous studies [35]. Although no direct comparison should be made about the sealing ability of the materials in clinical conditions, the fluid transport tests may provide pertinent information about their properties.

After hydration of MTA powder, hydroxyapatite crystals are developed and a hybrid layer between dentin and MTA is formed [36]. The morphology of the hydroxyapatite crystals is related to various factors including the environmental pH [37]. Literature has indicated that lower pH environments could affect various physical and chemical properties of MTA [2831, 38]. It has been shown that the low pH of the surrounding microenvironment affects the hydration reaction of MTA [39] and that the more acidic the MTA solution during the setting process, the more extensive is its porosity [30]. Furthermore, Saghiri et al. [31] reported that the time needed for leakage to occur was significantly shorter in samples stored at lower pH values. In both studies [30, 31], specimens were exposed to butyric acid with pH values of 4.4, 5.4, 6.4, and 7.4 for 4 and 3 days, respectively. Lee et al. [39] also reported that MTA crystals could dissolve in an environment of pH 5 and result in an unstable structure. In the present study, the materials were exposed for no longer than 24 h to citric acid buffered at pH 5.4, which probably did not affect the hydration behavior of MTA long term. In addition, various types of acid may have different effects on the physical and chemical properties of cements [40]. Lee et al. [39] did not state the type of acid, and this lack of information could also be one of the reasons for the different findings.

At the 3-month measurement, the MTA stored in saline showed statistically significant greater ability to prevent fluid movement than Biodentine in the same storage (p < 0.0001). However, when materials were stored in an acidic environment, no statistical significant difference was found at the 3-month measurement (Table 2). The exposure of Biodentine to the acidic environment enhanced the ability to prevent fluid movement over time (Table 2). These results could be caused by the alterations in the microstructure of Biodentine that were also observed after the exposure of the material to the citric acid (Fig. 1f). Although the precise explanation for these morphologic differences is unknown, the acid etching seems to result in morphologic changes of Biodentine in a different manner than MTA, which are in agreement with the results of Elnaghy [32]. These alterations of the properties of Biodentine after storage in acidic environment should be further studied before advocating the clinical application of Biodentine successively in lower pH values. These in vitro results are an indication about their potential capacity under these experimental conditions.

Conclusion

The exposure to an acidic environment seems to result in morphological changes of Biodentine in a different manner than MTA. MTA shows good ability to prevent fluid movement over time, in both environments. The ability of Biodentine to prevent fluid movement over time was enhanced in the acidic environment. Based on the results of the present study, it is not yet possible to make a clear recommendation about the material to be used in an acidic environment. These in vitro results are an indication about their potential behavior, and further research should be undertaken to establish a correlation between the exposure to an acidic environment and the clinical performance of these materials.