Introduction

Despite advances in the development of new endodontic sealers, it is clear that these materials still have significant limitations, mainly in the biological aspect [1]. Different materials have been used as bases for root canal sealers, and, recently, it is well accepted that natural products, especially those derived from plant extracts or from fermentation of bacteria, can have medicinal value or provide better biocompatibility. This can be of interest in endodontics, since a permanent irritation can maintain a chronic inflammatory response for undetermined time [2, 3].

In this context, an experimental root canal sealer based on the Copaifera multijuga oil-resin was developed, by associating this resin to calcium hydroxide and zinc oxide [4]. This oil-resin has a number of positive properties, namely the anti-inflammatory, antiseptic, antibacterial, and antifungal activities [58]. Another sealer, based on castor oil polymer, is obtained from Ricinus communis [9], having more than 80 % of its composition from ricinoleic acid triglyceride. Studies report that this experimental sealer is biocompatible, promotes healing, and presents antibacterial activity, good mechanical properties, and low cost [9, 10]. However, although these good properties from experimental sealers have been shortly described in the literature, no other study has assessed their level of cytotoxicity or genotoxicity when compared to other sealers available in the market.

Given this gap in the knowledge, the purpose of this study was to evaluate in vitro the cytotoxic and genotoxic effects of these two experimental root canal sealers. It was hypothesized that both natural sealers would be biocompatible, presenting lower cytotoxic and genotoxic levels than synthetic resin sealers.

Materials and methods

Preparation of extracts

Five sealers were used in this study: an epoxy resin-based sealer—Epoxy (AHPlus, Dentsply De Trey, Germany), a single methacrylate-based sealer—single methacrylate (EndoREZ, Ultradent, USA), a multi-methacrylate-based sealer—multi-methacrylate (RealSeal SE, SybronEndo, USA), an experimental sealer based on C. multijuga oil-resin—copaifera, and an experimental root canal sealer based on the polymer from R. communis—castor oil (Polifil, Poliquil, Brazil). Their complete compositions are described in Table 1.

Table 1 Main components, setting time, and manufacturer of tested sealers

All commercially available sealers (synthetic resin-based sealers) were prepared according to the manufacturer’s instructions. Natural resin-based sealers were prepared by mixing components as follows: 0.43 g of copaifera resin powder to 0.2 mL of liquid, and 0.44 g of castor oil paste with 0.18 g of liquid. Portions of each sealer were mixed and placed in a 24-well plate at a thickness of 2 mm and then incubated at 37 °C for 12 h immediately after mixing. Single methacrylate (EndoRez) specimens were covered with laboratory film and light polymerized for 40 s (780 mW/cm2).

Each test specimen was then covered with 2.5 mL of cell culture medium (Dulbecco’s modified Eagle medium (DMEM), Cultilab, Brazil), supplemented by 10 % fetal bovine serum (FBS) and 1 % from a stock solution of penicillin/streptomycin (10,000 U/mL), and incubated for 24 h at 37 °C. The original extracts (1:1) were prepared following the recommendations of the ISO 10993 at a rate of 82.4 mm2 sample surface area/mL cell culture medium.

Cytotoxicity test

Chinese hamster fibroblasts (V79) were cultured in DMEM supplemented by 10 % FBS, penicillin, and streptomycin at 37 °C and 5 % CO2. Cells (5 × 103) were seeded in each well of a 96-well plate and incubated for 24 h at 37 °C. Cultures were then exposed to 200 μL of the extracts in serial dilutions (1:1, 1:2, 1:4, and 1:8). Cell cultures with supplemented DMEM (FBS and antibiotic/antimycotic solution) were used as controls. After 24 h, cell viability was determined using the MTT assay. Cell cultures were gently washed with phosphate-buffered saline (PBS), and 100 μL of MTT solution was added to each well, followed by incubation (1 h at 37 °C). Reagents were removed and the resulting formazan product was solubilized in 100 μL of dimethyl sulfoxide. Optical density was measured in a spectrophotometer at 570 nm. Four replicate cell cultures were exposed to each of the extract serial dilutions in three independent experiments. Absorbance value readings were normalized to untreated control cultures (100 %), and statistical differences were assessed by ANOVA and Tukey’s test (p < 0.05).

Genotoxicity test

Cells (3 × 105) were seeded on microscopic glass slides and incubated with supplemented DMEM for 24 h at 37 °C and 5 % CO2. In this experiment, cells were exposed to the dilution of each sealer that gave cell viability close to 50 %, standardizing all samples. Most cytotoxic dilutions were not analyzed because they did not allow cell proliferation, invalidating the analysis. Untreated cell cultures and 5 mM ethyl methanesulfonate (EMS) were used as controls. The formation of micronuclei was analyzed microscopically, using 1000 cells/slide of 2 parallel cultures (slides) per concentration. At least 4 slides derived from 4 independent experiments were analyzed. To validate the micronuclei test, we also analyzed the number of cells in mitosis and in apoptosis. Statistical differences were assessed by ANOVA and Tukey’s test (p < 0.05).

Results

Cytotoxicity of root canal sealers

Cell viability results are shown in Fig. 1. All tested sealers were cytotoxic in more concentrated dilutions, excepting the castor oil polymer-based sealer, which was not cytotoxic in any dilution. The single methacrylate-based sealer was highly toxic to the cells, presenting 1.09 % of cell viability in original extract, 23.54 % in 1:4 dilution, and 41.95 % in 1:8 dilution. This means that it was tolerable (viability close to 50 %), only in the less concentrated dilution. Other tested sealers were in an intermediate level of cytotoxicity, with increased biocompatibility from the 1:2 dilution (for example, the epoxy resin achieved 5.75 % with the original extract and 61.89 % in 1:2 dilution) and no cytotoxicity in 1:4 and 1:8 extracts.

Fig. 1
figure 1

Cytotoxicity levels (% of the untreated control group) for the tested sealers, according to the dilution of the original extract. Four replicates in three independent experiments were analyzed. Bars represent mean and standard deviations. Statistical differences (p < 0.05) are marked by asterisk and/or cross symbol

Genotoxicity test

Micronuclei formation in V79 cells exposed to sealer extracts was analyzed, with EMS used as positive control (Fig. 2). The single methacrylate-based sealer was the most genotoxic, with a 14-fold increase of micronuclei number when compared with the untreated cell cultures, even above the number of micronuclei counted in the positive control group (EMS). None of the other sealers had significant genotoxic effect when compared to the untreated cultures. The number of cells in proliferation and cells in apoptosis are shown in Fig. 2, according to the micronuclei formation.

Fig. 2
figure 2

Genotoxicity levels (micronuclei counting) and cells in mitosis and in apoptosis for the tested sealers. Four replicates in four independent experiments were analyzed. Bars represent mean and standard deviations. Statistical differences (p < 0.05) are marked by asterisk, cross symbol, and/or black square

Discussion

In general, the experimental sealers presented mid to low cytotoxicity and no genotoxicity. The castor oil polymer-based sealer was not cytotoxic and not genotoxic, according to the tests performed in this study, when compared to commercially available synthetic resin-based sealers. The single methacrylate-based sealer presented a high level of cytotoxicity and genotoxicity.

The biological effectiveness of endodontic sealers is important for the success of endodontic therapy. The biological response depends on the molecular interactions that result from the interface between the sealers placed in contact with the tissues [11]. Therefore, a biocompatible sealer should not retard or arrest the process of tissue repair. In this context, the castor oil polymer-based sealer maintained a high level of cell viability consistently at all dilutions, which was recently reported by another study [12]. The C. multijuga-based sealer had cytotoxicity similar to the multi-methacrylate and the epoxy-resin-based sealers, which is among the average for the available sealers. This biocompatibility associated with its physicochemical properties, as required by the American Dental Association (ADA), indicate promise in clinical studies [4], which is even more important if its antimicrobial activity is considered [7]. The literature reports that the cytotoxicity present in this sealer is due to the natural resin (rosin) present in its composition [13].

Regarding the synthetic-resin-based sealers, the initial cytotoxicity of the epoxy-resin sealer was demonstrated previously, also in more concentrated extracts [12, 1419]. Other studies have reported little or no cytotoxicity of AH Plus; however, they had different experimental conditions [2022], such as different setting time [12, 19], contact area [12, 14, 19] and direct or indirect contact of the material with the cells [14]. The same levels of cytotoxicity were observed for the multi-methacrylate-based sealer. The literature reports that self-etching formulations are more biocompatible than regular methacrylate sealers, probably due to the incorporation of a relatively high concentration of polymerizable methacrylate carboxylic acid anhydride in these self-etching sealers [23]. High levels of cytotoxicity were already reported for the regular single methacrylate-based sealer [1, 15, 19, 2325]. The cytotoxic effect of this material may be caused by the presence of urethane dimethacrylate (UDMA) [26]. In contrast, other studies have shown little or no cytotoxicity of this material [17, 20, 21], which may also be related to the variability in experimental conditions and biological mechanisms, cell type, method of cell-material contact, preparation of extracts, and exposure time [22].

Genotoxicity testing was performed to complement the biocompatibility screening of the tested sealers. In general, it is expected that a low cytotoxic material should also present low genotoxicity. This was confirmed by our data, where only the single methacrylate-based sealer presented high levels of genotoxicity by remarkable increase in the number of micronuclei. In this case, it is possible that these effects are not only caused by the presence of UDMA. This compound is included in other methacrylate-based sealers, which did not present this pronounced genotoxic effect [12]. It is also possible that the induction of genotoxicity of this sealer is linked to the formation of reactive oxygen species (ROS) and oxidative DNA damage [27]. The castor oil polymer-based sealer did not present any levels of genotoxicity, as well as the copaifera resin-based sealer.

Clearly, the development of experimental sealers, based on natural resin polymers, may be an alternative to achieve better levels of biocompatibility. Of course, methods described here are extensively used in the literature as an initial screening on the biocompatibility of dental materials, not allowing extrapolation to clinical use. However, it may serve as a baseline to develop new sealers, in regard to their ability to promote (or not) hazardous effects to the cells. In this study, the castor oil polymer-based sealer presented impressive results with no levels of cytotoxicity and genotoxicity which, in association with well-developed mechanical properties, could present an almost ideal alternative in this field.

Conclusion

Original extracts presented the highest cytotoxicity activity, except for castor oil bean, which was not cytotoxic. The tested sealers did not present expressive cytotoxic levels in more diluted samples, excepting the single methacrylate, which was toxic in all dilutions. For genotoxicity test, single methacrylate was the only presenting genotoxic effects, when compared to the positive control.