Abstract
Cases of suicidal hanging are a common death referred for medico-legal autopsy throughout the world. Although some advocate using postmortem computed tomography (PMCT) without traditional invasive autopsy (TIA) to investigate such deaths, others reject this approach. There is currently limited evidence to guide practice. In this context, the TIA reports and PMCT images of 50 cases of suspected suicidal hanging during an 11-month period were reviewed. The reviewers were blinded to the findings of the other modality. A Cohen’s Kappa coefficient (K) was calculated to assess agreement between TIA and PMCT across a range of pertinent findings. This analysis demonstrated perfect agreement for identification of a ligature (K = 1.00) and a strong level of agreement for identification of a ligature suspension point (K = 0.832) but only a minimal level of agreement for overall ligature mark (K = 0.223). PMCT demonstrated a weak level of agreement for fractures of hyoid bone (K = 0.555) and thyroid cartilage (K = 0.538). Three probable fractures not identified at TIA were identified on PMCT. TIA was shown to be superior in the identification of intramuscular and laryngeal fracture–related haemorrhage/bruising whereas PMCT was superior to TIA in identifying body gas deposition. There was overall good correlation between the natural disease and trauma identified elsewhere in the body during the TIA and PMCT. The study demonstrates that PMCT can assist the investigation of suspected suicidal hangings. However, the accuracy of many findings is limited, and if it is used as an alternative to the TIA, potentially pertinent findings, such as fractures of the laryngeal cartilages, could be missed.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
In 2018, a total of 6507 deaths were registered as suicides within the UK, equating to a national average of 11.2 deaths/100,000. The group of hanging, strangulation and suffocation remained the most commonly chosen methods, accounting for 59.4% and 45.0% of suicides amongst males and females, respectively [1]. Whilst this group was not differentiated further, in our experience, we would expect hanging to account for the vast majority of these cases. In the UK, all suspected suicides would normally require an investigation by a coroner. This would typically include a postmortem examination and for the majority of cases a traditional invasive autopsy (TIA). However, in recent years, the use of less invasive techniques, such as postmortem-computed tomography (PMCT), in death investigation has been increasing throughout many regions of the UK [2]. As suicidal hangings constitute a common referral to coroners, it is extremely important that those involved in death investigation have an evidence-based understanding of the information that can be obtained from a PMCT scan compared to the TIA in such cases.
A review of the literature identified multiple manuscripts documenting specific findings on PMCT in relation to hangings and general papers outlining local approaches to death investigation and/or the overall application of PMCT in a wide range of causes of death [3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31,32,33,34,35]. There was consensus that PMCT was superior at detecting gas deposits in various anatomical scenarios specific to hanging, including the so-called gas bubble sign related to laryngeal cartilage fractures [5], soft tissue emphysema and pneumomediastinum [7,8,9, 23]. However, these findings were not present in all cases. In addition, there was general agreement that PMCT was less able to detect soft tissue haemorrhage in comparison to TIA [3, 9, 19, 23], the detection of which is important as it not only indicates antemortem injury, but if excessive may also suggest additional neck trauma prior to a ligature being applied, e.g. in a masked homicide. The majority of manuscripts also concluded that PMCT could detect laryngeal fractures, but there was considerable variation in the reported detection rates [3, 8,9,10, 20, 21, 23, 35]. Furthermore, many of the studies failed to set a reference standard or to complete the PMCT and/or TIA blind to the findings of the other modality. Indeed, none of the previous studies specifically assessed the agreement between PMCT and TIA in hangings and therefore critically assess the application of PMCT. There were also no large-scale studies.
During both TIA and PMCT, practitioners document information, e.g. trauma and natural disease, which may assist the coroner in investigating the circumstances leading to death. In cases of hanging, practitioners should also describe the ligature and ligature mark, as well as additional injuries to the skin and internal structures of the neck. In this context, our study aimed to assess whether PMCT can provide similar information, in these important areas, to the coronial investigation in cases of suspected suicidal hanging compared to TIA. The results should provide an evidence base for coroners, pathologists and others working within death investigation to justify the extent of the postmortem examination for this common cause of death.
Materials and methods
Subject recruitment
All suspected suicidal hangings that had undergone PMCT and TIA within the State Pathologist’s Department (SPD), Belfast, between 1st March 2020 and 31st January 2021 were considered for the study. Permission to use the case material for research was granted by the Coroner for Northern Ireland. Cases were excluded if the relevant anatomical regions, including the head, neck, chest, abdomen and pelvis, were not examined in full during TIA and PMCT. In addition, cases were excluded if the size of the deceased was greater than the CT-scanners 70 cm bore diameter.
PMCT
PMCT scanning was completed prior to the commencement of the TIA using a mortuary located 32-slice scanner (Somaton GO.UP Siemens Healthcare, Germany) which utilised automatic dose modulation. The body was retained within a sealed body bag and was placed on the CT scanner in as close to a supine position as rigor mortis, if present, allowed. Images of the head, neck, chest, abdomen and pelvis were acquired in every case. No gantry tilt was available. The scans and subsequent image reconstructions, including soft tissue and bone algorithms, were completed using pre-set protocols (Table 1). The CT images were reviewed by a single consultant radiologist with 24 years of clinical radiology experience and Fellowship of the Royal College of Radiologists, UK. The radiologist had no access to the TIA findings or report and was simply aware that each case was a suspected suicidal hanging. Images were viewed using an OsiriX Lite 12.0.1 DICOM viewer on a 2.5 GHz Intel Core i5 iMac computer attached to a RadiForce RX340 EIZO high-definition medical monitor which featured precise calibration compliant with the DICOM Part 14 standard.
Invasive autopsy
Following the PMCT, a TIA was completed by one of four consultant forensic pathologists with ≥ 18 years of autopsy experience and Fellowship of the Royal College of Pathologists, UK (RCPath). The autopsy entailed external and internal examinations, including the cranial, chest and abdominal cavities. An anterior neck dissection was completed in all cases. The examinations were to the standards set by the RCPath [36]. The pathologists did not review the PMCT images prior to the TIA. Furthermore, the pathologist did not have access to the radiologist’s report prior to the completion of the autopsy report.
PMCT and TIA analysis
Once fully completed, the reports from the TIA and PMCT examinations were reviewed. The positive and negative findings, including those pertinent to hanging and any additional evidence of trauma/injury, signs of natural disease and identifying features, were collated and entered into a spreadsheet in IBM SPSS statistics software version 26. A Cohen’s Kappa coefficient was calculated to test the agreement between the data generated by PMCT and TIA. It was considered important that any PMCT findings were accurate if they could be used in a coronial or police investigation. The thresholds for each level of agreement were therefore set to levels previously used in the clinical setting as published by McHugh [37].
Results
One hundred and twenty-five suspected suicidal hangings were referred to SPD during the 11-month study period. Of these, 63 underwent PMCT and TIA. The decision to undertake PMCT was primarily based on the consultant forensic pathologist and daily service pressures within the mortuary. There were no exclusions made on the basis of the size of the deceased and the restrictions of the CT-scanner bore diameter. However, following review of the PMCT images, 13 cases were excluded as the neck structures were not entirely captured. A total of 50 cases were therefore included in the study.
Case demographics
The study sample included 38 males (76%) and 12 females (24%). The average age of the decedents was 37.1 years (range 17–70; SD 13.75). The largest number of cases was within the 20–29 age bracket (n = 14) and case numbers decreased slightly through the following three decades. The postmortem interval was calculated for each case, based on the difference between the date and time when the individual was found dead and the date and time of the PMCT and TIA. The average postmortem interval was 31 h (range 7–87; SD 15.2).
Findings specific to hanging
In 11 (22%) of the 50 cases, the decedent was fully suspended when found hanging, i.e. no part of the body was in contact with another surface, causing the entirety of the body weight to be held by the ligature around the neck. In 28 cases (56%), part of the body remained in contact with another surface, e.g. the floor/ground or an object used to gain height. In the remaining 11 cases (22%), it was not known if the weight of the body was fully or partially suspended.
The TIA external examination revealed conjunctival petechial haemorrhages in 29 cases (58%). Six of these were fully suspended decedents, 17 partially suspended and 6 in those where the degree of suspension was not known. This corresponded to 60.7%, 54.5% and 54.5% of each group, respectively. Perhaps not unexpectantly petechial haemorrhages were not identified during PMCT.
Ligature
In 20 cases (40%), the ligature used in the hanging was submitted with the deceased and remained around the neck of the decedent at the time of PMCT and TIA. PMCT identified all 20 of the ligatures present and did not suggest the presence of any ligature in the remaining 30 cases. This perfect agreement produced a Cohen’s Kappa coefficient (K) of 1.00.
In addition, it was noted that the PMCT images frequently provided a detailed archive of the ligature. Of those identified, it was almost always possible to specify the ligature type, such as a rope, belt and wire cable, using a combination of standard axial images and 3D-volume-rendering techniques (Figs. 1). Furthermore, the PMCT images could allow knot detail to be reviewed and with windowing techniques, the head and/or neck could be removed from the generated image(s) (Fig. 2). The latter of these provides sanitised images, potentially useful for court purposes. Of note, however, the ligature did not always remain within or in close proximity to the ligature mark (Fig. 3) and therefore careful review of the DICOM images is recommended.
Ligature mark and suspension point
A ligature mark was identified in 49 cases (98%) during TIA. In the single case in which no ligature mark was observed, a soft woollen scarf was used as the ligature and there was partial suspension of the body with the decedent found in a kneeling position. PMCT failed to identify the ligature mark in an additional 6 cases, therefore 14% (n = 7) of the overall study population. Using Cohen’s Kappa test, a result of 0.223 was achieved demonstrating a minimal level of agreement between the modalities.
In each of the 7 cases where no ligature mark was identified during PMCT, the ligature mark described at TIA had no depth to it, comprising bands of pale/pink skin (Fig. 4). In addition, the cases involved a relatively soft ligature in 4 cases and partial suspension in 5 cases.
The ligature suspension point was identified in 48 cases (96%) during TIA. PMCT did not identify the suspension point in the same two cases as TIA, as well as a further 5 cases. This corresponded to the same 7 (14%) cases where the ligature mark was not identified on PMCT. Of the 43 suspension points identified on PMCT (Fig. 5), there was complete concordance with the position recorded at TIA. A Cohen’s Kappa coefficient was calculated as 0.832, consistent with a strong level of agreement between the modalities.
In addition to the above, we noted that during review of the PMCT scans, the identification of the ligature mark and point of suspension was more difficult if there were prominent skin folds within the neck region. This was observed in cases where the deceased was obese and/or if the neck was in an obscure position. Furthermore, we found that windowing techniques were useful to confirm the position of the suspension point, as identified during TIA, in individuals with a large volume of scalp hair.
Intramuscular haemorrhage
Bruising of the anterior neck muscles was identified in only a minority of cases, 3 (6%), during TIA. In all of these cases, the haemorrhage/bruising was reported as slight. PMCT did not specifically identify intramuscular haemorrhage, but soft tissue swelling and vascular congestion were recorded in 12 cases (24%), potentially representative of congestion secondary to hanging and/or hypostasis. Two of these cases also had TIA-identified intramuscular haemorrhage, but a Cohen’s Kappa coefficient was calculated as 0.189 demonstrating no significant agreement.
Laryngeal fractures
A total of 56 fractures were identified during TIA, within 26 cases (52%). Review of the PMCT scans revealed 36 fractures within 22 cases (44%). Fractures of the superior horns of the thyroid cartilage were the most frequently identified in both modalities (Figs. 6 and 7). Furthermore, TIA recorded that 1 of the superior horns of the thyroid cartilage was fractured in 2 places in 3 cases. However, whilst PMCT identified one of these ‘double fractures’, the injuries were counted as a single fracture within the fracture statistics.
No fractures of the cricoid cartilage were recorded during TIA or PMCT. However, in a single case, the radiologist noted low attenuation.
Of the 56 laryngeal fractures identified during TIA, 30 (53.57%) were also identified on PMCT (Fig. 8). Of the 26 (46.43%) fractures not identified on PMCT, 8 were within the hyoid bone and 18 were within the thyroid cartilage, representing 44.44% and 47.37% of each group, respectively (Fig. 9).
A fracture or fractures were identified within the hyoid bone in 13 cases (26%) during TIA, corresponding to 18 individual fractures, 8 left-sided and 10 right-sided. Hyoid fracture(s) were identified in 13 cases with PMCT, totalling 14 individual fractures, 4 left-sided and 10 right-sided. However, despite the similar case/fracture numbers, crosstabulation revealed that 8 of the 18 fractures recorded during TIA were not identified on PMCT. Conversely, 4 fractures were reported on PMCT, but not during TIA. Cohen’s Kappa coefficients were calculated for left- and right-sided fractures, as well as overall for the hyoid bone (Table 2). The overall result of 0.555 demonstrates a weak level of agreement. Furthermore, in comparison to TIA, PMCT demonstrated a sensitivity of 55.6% and a specificity of 95.1% for hyoid bone fractures.
Fracture(s) of the thyroid cartilage were identified in 22 cases (44%) during TIA, including 38 individual fractures, 21 left-sided and 17 right-sided. Thyroid cartilage fracture(s) were recorded in 18 cases (36%) with PMCT, corresponding to 22 individual fractures, 11 on each side. Crosstabulation revealed that 18 of the 38 fractures recorded during TIA were not identified on PMCT. Conversely, 2 fractures were reported on PMCT, but not during TIA. Cohen’s Kappa coefficients were again calculated for left- and right-sided fractures, as well as overall for the thyroid cartilage (Table 3). The overall result of 0.538 demonstrates a weak level of agreement with a PMCT sensitivity of 52.6% and specificity of 96.8% compared to TIA.
As discussed above, PMCT identified 6 fractures not described during TIA, 4 within the greater horns of the hyoid bone and 2 within the superior horns of the thyroid cartilage. Following review of the images, one of these represented a definite missed diagnosis during TIA (Fig. 10B). Two were considered probable missed fractures during TIA. However, three of the fractures described only on PMCT probably represented anatomical variations misdiagnosed as fractures on PMCT (Fig. 10D).
Bruising/haemorrhage associated with the laryngeal fractures was identified during TIA in 19 (38%) cases. These included 6 of the 13 cases with fractures of the hyoid bone and 13 of the 22 cases with fractures of the thyroid cartilage. No fracture-associated bruising/haemorrhage was specifically mentioned by the radiologist reporting the PMCT scans. However, soft tissue swelling and asymmetry were reported in some cases, including those without fractures.
Laryngeal anomalies
Anomalies within the hyoid bone were identified in 3 cases (6%) during TIA. These included 2 sets of calcified stylo-hyoid ligaments and a single misshapen right greater horn, possibly representative of a previous fracture. PMCT identified 10 anomalies within 9 hyoid bones, including non-fusion (n = 3), widening of the fibrocartilage joint (n = 4), osteophytes (n = 2) and calcified stylo-hyoid ligaments (n = 1) (Fig. 11b).
The commonest anatomical variation in the thyroid cartilage was the presence of a triticeal cartilage(s) within the lateral thyrohyoid ligament. These were identified within 24 cases (48%) during TIA, 4 (8%) solitary left-sided, 5 (10%) solitary right-sided and 15 (30%) bilateral. Therefore, a total of 39 triticeal cartilages were described during TIA, but only 3, equating to 7.69%, were also identified with PMCT, 2 left-sided and 1 right-sided. However, PMCT identified 4 additional anatomical variations/deviations within the thyroid cartilage, all of which were due to asymmetrical deformity (Fig. 11a).
Gas deposition
Gas deposits were identified within the neck structures in 23 cases (46%) on PMCT. These had an average postmortem interval of 34.52 h (SD 16.5), whereas those without subcutaneous gas had an average postmortem interval of 28.00 h (SD 13.67). Five of the 23 cases had extensive subcutaneous emphysema within the neck structures, and all of these had concomitant decomposition gas artefact throughout the remainder of the body, including the mediastinum (Fig. 12). The average postmortem interval for these cases was 37.80 h (SD 15.09). The remaining 18 cases in which gas deposits were identified had only minimal focal deposits within the neck structures, including within blood vessels (n = 5), peri-clavicular soft tissues (n = 5), anterior neck muscles (n = 6) and peri-laryngeal soft tissues (n = 3).
Gas artefact was identified within the liver in 23 cases (46%) during PMCT. Of these, the average postmortem interval was 32.57 h (SD 17.27), compared to an average postmortem interval of 29.04 h (SD 13.32) in cases where no hepatic gas was identified. Crosstabulation revealed that of the 23 cases where hepatic gas was detected, 18 also had gas deposits within the neck structures. Therefore, only 5 cases where gas deposits were identified within the neck did not have concomitant gas within the liver (Fig. 13).
Gas bubbles were identified in proximity of fractures reported during TIA and/or PMCT in 4 (8%) cases. All of these were within the superior horns of the thyroid cartilage (Table 4). In only one of these cases, case 11, was the gas bubble associated with a fracture identified on both modalities. However, this case also contained a tiny gas bubble within the right superior horn which was not reported as fractured on either TIA or PMCT (Fig. 14). In addition, two of the gas bubbles identified were associated with fractures considered missed during TIA, cases 7 and 24, but the latter of these had extensive decomposition gas artefact (Fig. 10A, B). In the final case, case 23, the gas bubble identified was associated with the right superior horn, but there was no displacement of the cartilage and the radiologist did not record a definite fracture. In contrast, the displaced fracture identified on PMCT in this case did not have any associated gas bubble (Fig. 15). TIA revealed bilateral fractures of the superior horns in this case.
Cervical spine
There were no fractures of the cervical spine identified within any of the 50 cases. However, due to the often suboptimal position of the neck, primarily due to rigor mortis, the radiologist could not confidently confirm or exclude ligamentous injury, e.g. based on the relationship between vertebrae. In 4 cases (8%), osteoarthritic changes were identified within the cervical spine during PMCT.
Natural disease
Due to the relatively young age of the majority of the decedents included in the study, average 37.1 years, the vast majority had only minor/incidental natural disease identified during TIA and/or PMCT. It was not a primary objective of this study to offer a detailed scientific analysis of specific conditions. However, in general, there was good correlation between the natural disease identified during TIA and PMCT. Whilst a number of discrepancies between the natural disease detected during TIA and PMCT were identified (Table 5), there were no missed diagnoses critical to providing the medical cause of death. Indeed, all of the discrepancies, as summarised in Table 5, could be classified as category 3 errors, i.e. likely to be of little clinical significance, in accordance with definitions previously recommended by RCPath [38]. Furthermore, the discrepancies largely represent the limitations of each modality, e.g. in the absence of angiography, it was inevitable that minor coronary artery disease would not be detected on PMCT. Similarly, the dissection required to diagnose sinusitis during TIA could never be justified in a case of suspected suicidal hanging.
Trauma
Additional internal trauma was also documented with each modality. The most common finding recorded during both TIA and PMCT was sternal and anterior rib fractures, detected in 9 cases (18%). These were attributed to resuscitative chest compressions. A number of relatively small bruises of the undersurface of the scalp were identified during TIA, but none were recorded with PMCT. In addition, old cortical contusions, secondary to previous head injury, were identified in 2 cases (4%) during TIA. These were not seen during initial reporting of the PMCT scan, nor following review of the scans after completion of the study. A single old wedge compression fracture of T12 was identified on PMCT and not diagnosed during TIA. However, similar to the variation in natural disease detected, none of this additional trauma was critical to the cause of death or circumstances of the case and again could be classified as category 3 errors.
Toxicology
Potential drug and alcohol toxicity forms another part of the investigation of a suspected suicidal hanging by the coroner. Blood samples were retained in all 50 cases in this study. A urine sample was also available in 45 cases (90%). All of these samples were submitted for alcohol analysis with average concentrations of 77.24 mg/100 ml (maximum 268 mg/100 ml; SD 93.53) in the blood and 104.58 mg/100 ml (maximum 335 mg/100 ml; SD 117.96) in the urine. Of note, however, 25 cases (50%) had no alcohol in the bloodstream and 18 had none in the urine. Of the 21 cases (42%) over the current legal limit for driving in Northern Ireland, 80 mg/100 ml, the average blood alcohol was 176.48 mg/100 ml.
Fourteen cases (28%) also had toxicology/drug analysis completed. No drugs were detected in one of these cases. The drugs recorded in the remaining cases comprised a range of common pharmaceutical medications and drugs of abuse.
Whilst alcohol and/or drug analyses can be ordered during a TIA or a minimally invasive PMCT, autopsy findings may assist practitioners to make this decision. In particular, high attenuation fragments, suggestive of medication tablets, were identified within the stomach in 6 cases (12%) on PMCT (Fig. 16). In four of these, tablet collections were also found during TIA.
Foreign bodies
Finally, PMCT identified a couple of foreign objects not recorded during TIA. These included a subcutaneous contraceptive device within the right arm and metallic foreign bodies in proximity of the right maxillary sinus. However, there was no inferences drawn from these additional findings and both were classified as category 3 discrepancies.
Discussion
Our study has shown a varied set of results for the agreement obtained between PMCT and TIA in cases of suspected suicidal hanging. There was perfect agreement (K = 1.00) between the modalities for the identification of the ligature, a conclusion that would be supported by other manuscripts [4, 9, 18]. We have also shown that PMCT provides a detailed archive, allowing future examination of the ligature characteristics and knot detail, and sanitised images, potentially useful for court purposes. However, despite 43 of the 50 ligature marks being correctly identified with PMCT, statistical analysis only demonstrated a minimal level of agreement with TIA (K = 0.223). In contrast, our study demonstrated a strong level of agreement (K = 0.832) between PMCT and TIA in the identification of a suspension point. We believe that we are the first to provide statistical data in this area. Furthermore, we found that the identification of the ligature mark and suspension point during PMCT was more difficult if there were prominent skin folds within the neck region. This was observed in cases where the deceased was obese and/or if the neck was in an obscure position, typically secondary to rigor mortis.
Internally, we found that PMCT could not identify intra-muscular haemorrhage, but such injuries were only present in a minority of the study cases. On the other hand, PMCT did demonstrate soft tissue swelling and vascular congestion within the neck, but analysis showed no significant agreement between the modalities (K = 0.189). Perhaps more importantly, our study has shown only a weak level of agreement between PMCT and TIA in fractures of the hyoid bone (K = 0.555) and thyroid cartilage (K = 0.538). This would be similar to the results of Hueck et al., who reported a Cohen’s Kappa coefficient of 0.54 for injuries of the laryngeal cartilages [9], albeit the group subsequently used different thresholds for the stated level of agreement. We also experienced the same difficulties in diagnosing laryngeal fractures as outlined by other groups, including decreased ossification [4, 19, 21], the size of the lesions [21] and non-displaced fractures [21]. However, there is considerable variation in the rate of detection of laryngeal fractures using PMCT within the medical literature. Deininger-Czermak et al. used a high-resolution PMCT scan of the larynx in addition to a whole body PMCT and reported more radiologically identified fractures than during TIA [8]. Furthermore, Decker et al. [35] concluded that PMCT was equal to TIA in the detection of laryngeal fractures and Le Blanc-Louvry et al. [20] found almost perfect concordance between PMCT and TIA with fractures of the hyoid bone. However, these conclusions were based on small numbers of fractures, 12 and 5, respectively. In support of radiological assessment, our study recorded a small number of fractures identified on PMCT only, which would suggest that TIA is not an infallible technique.
It is well recognised that PMCT is superior to TIA in the identification of gas deposition within the body [9]. In hanging cases, fracture-associated gas bubbles and subcutaneous emphysema have been described, but again there is some variation in results/opinions across manuscripts [3, 5, 7,8,9, 12, 17, 19, 23]. Schulze et al. reported that a ‘gas bubble sign’ was highly suggestive of laryngeal fractures in hanging cases with a positive-predictive-value of 95% and overall accuracy of 83%, but the study excluded decomposed decedents [5]. In contrast, the two papers by Deininger-Czermak et al. identified fracture-related gas bubbles in only 20% [8] and 16.67% of cases [19], and additional gas bubbles in proximity of the laryngeal structures without any fractures in 16% of cases [8]. Our study recorded gas bubbles in proximity of fractures in only 8% of cases, and only one of these fractures was identified during both TIA and PMCT. We also identified gas bubbles in proximity of non-fractured laryngeal structures. In addition, our study identified gas deposits within the neck structures during PMCT in 23 cases (46%), 18 of which also had gas deposition within the liver. Indeed, analysis showed that these cases had a higher average postmortem interval compared to those where no subcutaneous gas was observed, 34.52 and 28.00 h, respectively. Furthermore, in all 5 cases where subcutaneous emphysema within the neck was extensive, there was decomposition gas artefact throughout the rest of the body and the average postmortem interval was even longer (37.80 h). In the remaining 18 cases in which gas deposits were identified, these were described as minimal focal deposits within the neck structures. Therefore, overall, we did not find gas deposition a particularly useful indicator of hanging and any deposits should be interpreted in relation to decomposition of the body.
In addition, our study demonstrated overall good correlation in the natural disease and trauma diagnosed on PMCT and TIA, with only minor discrepancies identified. Whilst none of these were critical to providing the medical cause of death, i.e. hanging, arguably some may offer additional information potentially relevant to a coronial investigation, e.g. potential behavioural effects associated with hypothyroidism or old frontal cortex contusions. However, it is often not possible to confirm or quantify the effect such pathologies may have had on an individual from the autopsy findings.
Finally, in a small number of cases, additional information was provided by PMCT, e.g. suspected tablet residue within the stomach in 12% of cases. Such information would assist the pathologist and/or coroner in a decision to order toxicological analyses.
Summary
Our study provides quantitative data to assist with the ‘real world’ day-to-day decisions being made by death investigation professionals in a common case type. The research has shown that PMCT can augment, to a degree, the postmortem examination in cases of suspected suicidal hanging, primarily by providing an archive of the body and, if present, the ligature. However, the technique should not be used as a replacement for a ‘naked-eye’ external examination by an experienced autopsy pathologist. Furthermore, the research demonstrated that PMCT missed a considerable number of laryngeal fractures. Whilst this may be improved with additional PMCT protocols, radiological methods and/or optimised positioning of the body, all of which could form future research, it would seem reasonable to suggest that standard PMCT examinations should not be completed in isolation to diagnose or exclude neck trauma, not only in hanging cases but across all case types.
Data availability
The datasets generated during the current study are not publicly available as the information is the legal property of the Coroner for Northern Ireland.
References
Suicides in the UK (2019) 2018 registrations, registered deaths in the UK from suicide analysed by sex, age, area of usual residence of the deceased and suicide method, Statistics Bulletin. In: Statistics OfN, editor. 3rd September. https://www.ons.gov.uk/peoplepopulationandcommunity/birthsdeathsandmarriages/deaths/bulletins/suicidesintheunitedkingdom/2018registrations last visited May 2022
Coroners Statistics (2019) England and Wales,Ministry of Justice. 29th May 2020. https://www.gov.uk/government/statistics/coroners-statistics-2019/coroners-statistics-2019-england-and-wales last visited may 2022
Gascho D, Heimer J, Tappero C, Schaerli S (2019) Relevant findings on postmortem CT and postmortem MRI in hanging, ligature strangulation and manual strangulation and their additional value compared to autopsy - a systematic review. Forensic Sci Med Pathol 15(1):84–92. https://doi.org/10.1007/s12024-018-0070-z
Garetier M, Deloire L, Dedouit F, Dumousset E, Saccardy C, Ben Salem D (2017) Postmortem computed tomography findings in suicide victims. Diagn Interv Imaging 98(2):101–112. https://doi.org/10.1016/j.diii.2016.06.023
Schulze K, Ebert LC, Ruder TD, Fliss B, Poschmann SA, Gascho D et al (2018) The gas bubble sign-a reliable indicator of laryngeal fractures in hanging on post-mortem CT. Br J Radiol 91(1084):20170479. https://doi.org/10.1259/bjr.20170479
Polacco M, D’Alessio P, Ausania F, Zobel B, Pascali VL, d’Aloja E et al (2013) Virtual autopsy in hanging. Am J Forensic Med Pathol 34(2):107–109. https://doi.org/10.1097/PAF.0b013e318288c6d6
Aghayev E, Yen K, Sonnenschein M, Jackowski C, Thali M, Vock P et al (2005) Pneumomediastinum and soft tissue emphysema of the neck in postmortem CT and MRI; a new vital sign in hanging? Forensic Sci Int 153(2–3):181–188. https://doi.org/10.1016/j.forsciint.2004.09.124
Deininger-Czermak E, Heimer J, Tappero C, Thali MJ, Gascho D (2020) The added value of postmortem magnetic resonance imaging in cases of hanging compared to postmortem computed tomography and autopsy. Forensic Sci Med Pathol 16(2):234–242. https://doi.org/10.1007/s12024-020-00233-4
Hueck U, Muggenthaler H, Hubig M, Heinrich A, Guttler F, Wagner R et al (2020) Forensic postmortem computed tomography in suspected unnatural adult deaths. Eur J Radiol 132:109297. https://doi.org/10.1016/j.ejrad.2020.109297
Khokhlov VD (2015) Trauma to the hyoid bone and laryngeal cartilages in hanging: review of forensic research series since 1856. Leg Med (Tokyo) 17(1):17–23. https://doi.org/10.1016/j.legalmed.2014.09.005
Wallace SK, Cohen WA, Stern EJ, Reay DT (1994) Judicial hanging: postmortem radiographic, CT, and MR imaging features with autopsy confirmation. Radiology 193(1):263–267. https://doi.org/10.1148/radiology.193.1.8090904
Sieswerda-Hoogendoorn T, Strik AS, Hilgersom NF, Soerdjbalie-Maikoe V, van Rijn RR (2014) Pneumomediastinum and soft tissue emphysema in pediatric hanging. J Forensic Sci 59(2):559–563. https://doi.org/10.1111/1556-4029.12315
Naimo P, O’Donnell C, Bassed R, Briggs C (2015) The use of computed tomography in determining development, anomalies, and trauma of the hyoid bone. Forensic Sci Med Pathol 11(2):177–185. https://doi.org/10.1007/s12024-015-9655-y
Sohail S, Mirza FH, Khan QS (2010) Postmortem computed tomography for diagnosis of cause of death in male prisoners. J Pak Med Assoc 60(1):4–8
Reay DT, Cohen W, Ames S (1994) Injuries produced by judicial hanging. A case report. Am J Forensic Med Pathol 15(3):183–6. https://doi.org/10.1097/00000433-199409000-00001
Cirielli V, Cima L, Bortolotti F, Narayanasamy M, Scarpelli MP, Danzi O et al (2018) Virtual autopsy as a screening test before traditional autopsy: the Verona experience on 25 cases. J Pathol Inform 9:28. https://doi.org/10.4103/jpi.jpi_23_18
Chatzaraki V, Tappero C, Thali MJ, Schweitzer W (2018) Death by hanging: a retrospective case-control investigation of the intervertebral disc vacuum phenomenon on PMCT. Forensic Sci Med Pathol 14(4):484–496. https://doi.org/10.1007/s12024-018-0034-3
Willaume T, Farrugia A, Kieffer EM, Charton J, Geraut A, Berthelon L et al (2018) The benefits and pitfalls of post-mortem computed tomography in forensic external examination: a retrospective study of 145 cases. Forensic Sci Int 286:70–80. https://doi.org/10.1016/j.forsciint.2018.02.030
Deininger-Czermak E, Heimer J, Tappero C, Thali MJ, Gascho D (2020) Postmortem magnetic resonance imaging and postmortem computed tomography in ligature and manual strangulation. Am J Forensic Med Pathol 41(2):97–103. https://doi.org/10.1097/PAF.0000000000000542
Le Blanc-Louvry I, Thureau S, Duval C, Papin-Lefebvre F, Thiebot J, Dacher JN et al (2013) Post-mortem computed tomography compared to forensic autopsy findings: a French experience. Eur Radiol 23(7):1829–1835. https://doi.org/10.1007/s00330-013-2779-0
Graziani G, Tal S, Adelman A, Kugel C, Bdolah-Abram T, Krispin A (2018) Usefulness of unenhanced post mortem computed tomography - findings in postmortem non-contrast computed tomography of the head, neck and spine compared to traditional medicolegal autopsy. J Forensic Leg Med 55:105–111. https://doi.org/10.1016/j.jflm.2018.02.022
Loper N, Garland J, Chahal S, Milne D, O’Connor K, Kesha K et al (2020) Post mortem computed tomography (PMCT) lung changes in suicide hanging deaths: a case series. Pathology 52:S102
Elifritz J, Hatch G, Kastenbaum H, Gerrard C, Lathrop S, Nolte K (2014) 1.8. PMCT findings in hanging. J Forensic Radiol Imaging 2(2):97
Kasahara S, Makino Y, Hayakawa M, Yajima D, Ito H, Iwase H (2012) Diagnosable and non-diagnosable causes of death by postmortem computed tomography: a review of 339 forensic cases. Leg Med 14(5):239–245. https://doi.org/10.1016/j.legalmed.2012.03.007
Bolliger S, Thali M, Jackowski C, Aghayev E, Dirnhofer R, Sonnenschein M (2005) Postmortem non-invasive virtual autopsy: death by hanging in a car. J Forensic Sci 50(2):455–460
Burton JL, Kitsanta P (2020) Daily application of post-mortem computed tomography digital autopsy in a public mortuary. Diagn Histopathol 26(8):358–367. https://doi.org/10.1016/j.mpdhp.2020.05.004
Hutchinson JC, Sebire NJ, Arthurs OJ (2017) The role of cross-sectional imaging in the investigation of childhood deaths. Essentials of Autopsy Practice. Reviews, Updates and Advances. Ed, GN Rutty. Springer, London. p. 1–21
Bertozzi G, Maglietta F, Salerno M, Caffarelli FP. (2020) Forensic radiology: penetrating versus non-penetrating trauma. Radiology in Forensic Medicine. Eds Giuseppe Lo Re, Antonina Argo, Massimo Midiri, Cristina Cattaneo. Springer, London. p. 157–68
Naimo P, O’Donnell C, Bassed R, Briggs C (2013) The use of computed tomography in determining developmental changes, anomalies, and trauma of the thyroid cartilage. Forensic Sci Med Pathol 9(3):377–385. https://doi.org/10.1007/s12024-013-9457-z
Sieswerda-Hoogendoorn T, Soerdjbalie-Maikoe V, de Bakker H, van Rijn RR (2014) Postmortem CT compared to autopsy in children; concordance in a forensic setting. Int J Leg Med 128(6):957–965. https://doi.org/10.1007/s00414-014-0964-6
de Bakker BS, de Bakker HM, Soerdjbalie-Maikoe V, Dikkers FG (2019) Variants of the hyoid-larynx complex, with implications for forensic science and consequence for the diagnosis of Eagle’s syndrome. Sci Rep 9(1):15950. https://doi.org/10.1038/s41598-019-52476-z
de Bakker HM, Warmbrunn MV, van den Biggelaar P, Soerdjbalie-Maikoe V, de Bakker BS (2020) Fracture patterns of the hyoid-larynx complex after fatal trauma on the neck: retrospective radiological postmortem analysis of 284 cases. Int J Legal Med 134(4):1465–1473. https://doi.org/10.1007/s00414-019-02241-8
de Bakker HM, Warmbrunn MV, van den Biggelaar P, Soerdjbalie-Maikoe V, de Bakker BS (2020) Correction to: fracture patterns of the hyoid-larynx complex after fatal trauma on the neck: retrospective radiological postmortem analysis of 284 cases. Int J Legal Med. https://doi.org/10.1007/s00414-020-02382-1
de Bakker HM, Olsthoorn PC, Soerdjbalie-Makoe V, de Bakker BS (2020) Comparison of post-mortem radiologic modalities to evaluate suspected neck violence. Forensic Imaging 21:200373
Decker LA, Hatch GM, Lathrop SL, Nolte KB (2018) The role of postmortem computed tomography in the evaluation of strangulation deaths. J Forensic Sci 63(5):1401–1405. https://doi.org/10.1111/1556-4029.13760
Leadbeatter S, Lucas S, Lowe J. Standards for coroners’ pathologists in post-mortem examinations of deaths that appear not to be suspicious. London: The Royal College of Pathologists. 2014. https://www.rcpath.org/uploads/assets/1b02cfb9-000a-4b2f-b6b80256b719a5ee/Standards-for-Coroners-pathologists-in-post-mortem-examinations-of-deaths-that-appear-not-to-be-suspicious.pdf last visited May 2022
McHugh ML (2012) Interrater reliability: the kappa statistic. Biochemia medica 22(3):276–82. https://doi.org/10.11613/BM.2012.031
Review of categorisation of discrepancies in histopathology. In: Pathologists RCo, editor. LondonNovember 2008. https://www.rcpath.org/uploads/assets/554f0249-a9dc-4c23-a9cfd6b2baa2c9b1/Review-of-the-categorisation-of-discrepancies-in-histopathology-2008.pdf last visited May 2022
Acknowledgements
We wish to thank Drs P.J. Ingram, A.J. Bentley and M.J. Egan and the staff within the Northern Ireland Regional Forensic Mortuary for their assistance with the TIA examinations. We wish to thank His Honour Judge P. McGurgan, Coroner for Northern Ireland, for permitting access to the reports.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study’s conception and design. Material preparation, data collection and analysis were performed by James Lyness and Anthony Collins. The first draft of the manuscript was written by James Lyness, and all authors commented on subsequent versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval
None required as undertaken as part of a service evaluation project. This was a retrospective study using data obtained during medico-legal autopsy examinations for the coroner. As the coroner is the legal owner of all such material under UK law, permission to use case material for research was requested by the primary author and subsequently granted by the coroner for Northern Ireland. No animals were used in this research.
Consent to participate
Permission to use case material for research was granted by the coroner for Northern Ireland.
Conflict of interest
The authors declare no competing interests.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
The abbreviated results of this study have been presented as short oral presentations at the following meetings; AAFS, virtual presentation, February 2022; ISFRI annual conference (virtual meeting), May 2022, Japan.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Lyness, J.R., Collins, A.J., Rutty, J.E. et al. Comparison of findings identified at traditional invasive autopsy and postmortem computed tomography in suicidal hangings. Int J Legal Med 136, 1865–1881 (2022). https://doi.org/10.1007/s00414-022-02874-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00414-022-02874-2