Abstract
Mass attenuation coefficients (\(\mu _{\text {m}}\)) for some nonlinear optical materials such as potassium dihydrogen phosphate, ammonium dihydrogen phosphate, zinc tris-thiourea sulphate, and zinc thiourea chloride were measured using a \(2\times 2\) NaI(Tl) scintillation detector at gamma energies of 122 keV, 356 keV, 511 keV, 662 keV, 840 keV, 1170 keV, 1270 keV, and 1330 keV. In addition, GEANT4 simulations were carried out to mimic the experiment at these energies. As a result, good agreement between the experimental and GEANT4 results was observed. The measured \(\mu _{\text {m}}\) values were used to compute effective atomic numbers (\(Z_{\text {eff}}\)) for the selected materials. It was found that the \(Z_{\text {eff}}\) values were in the range typical for dosimetric materials.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Because ionsing radiation is widely used whether this is in a hospital, laboratory, nuclear power plant, or nuclear waste treatment location, it is very important to measure and quantify how much radiation is produced by any radioactive sources and how much radiation is absorbed by materials. This requires methods that allow determination of relevant radiation interaction parameters. For example, absorbed dose in matter can be obtained by solving radiation transmission equations. For gamma ray radiation, narrow beam geometry can be employed including the Beer–Lambert law (Swinehart 1962). In fact, narrow beam geometry is considered an essential setup to study the gamma ray interaction with matter by determining linear attenuation coefficients or mass attenuation coefficients. The latter coefficients are used to describe the probability of photon–matter interactions per unit mass and unit area (McNair 1981; Chantler 2000). The \(\mu _{\text {m}}\) values are essential to derive atomic cross sections, electronic cross sections, and effective atomic numbers for a compound or mixture. The notion of effective atomic number was introduced first by Hine who noticed that the effective atomic number of a mixture or compound is not constant but variable with photon energy (Hine 1951). Nowadays, it is well known that \(\mu _{\text {m}}\) and \(Z_{\text {eff}}\) are the most important parameters for selection of suitable materials for radiation dosimetry and radiation detection.
Many attempts have been made to identify materials to be used as radiation dosimeters. Reddy studied the radiation response of several liquid and solid materials (Kumar and Reddy 1997), using elemental data from Hubbell and Seltzer (1995), Chantler (1995). Shivaramu calculated the effective atomic numbers of some thermoluminescent dosimetric (TLD) materials such as LiF, \(\hbox {CaCO}_3\), and \(\hbox {CaSO}_4\) (Ramprasath et al. 2000). He concluded that effective atomic numbers vary linearly with photon energy. The mass attenuation coefficients of some TLD materials were also experimentally determined at different photon energies in a narrow beam geometry using a hyper pure germanium detector (Gowda et al. 2004). The radiological features of some gel materials were compared against water with respect to their \(Z_{\text {eff}}\) values (Taylor et al. 2008). In addition, gamma-ray buildup factors for TLD materials were reported and compared with ICRU standard dosimeters (Manohara et al. 2010; Kucuk et al. 2013; Singh and Badiger 2016). Recently, \(\mu _{\text {m}}\) values for some polymers were determined using Monte Carlo simulation at different photon energies (Singh et al. 2015). In addition, there are numerous similar studies dealing with various materials using different methods including measurements, theoretical considerations, or simulations (Sidhu et al. 2012; Özdemir and Kurudirek 2009; Kurudirek 2014; Bootjomchai and Laopaiboon 2014; Singh et al. 2014).
Nonlinear optical NLO materials were found to be useful for many applications: for smart filtering (Dini et al. 2016), for photonics (Lin et al. 2014), and for biomedicine and radiation detection (Liu et al. 2017). NLO materials might possibly be used in biological dosimetry because of the following properties: their strength, lightness, low cost, and ease of fabrication. Very recently, Awasarmol studied some organic NLO materials in terms of \(\mu _{\text {m}}\) and \(Z_{\text {eff}}\) (Awasarmol et al. 2017). He found that the NLO materials can support radiation measurement due to their low \(Z_{\text {eff}}\). At present, fundamental gamma interaction parameters for selected NLO materials have not yet been published.
This prompted the present study in which dosimetric parameters of various NLO materials such as such as potassium dihydrogen phosphate, ammonium dihydrogen phosphate, zinc tris-thiourea sulphate, and zinc thiourea chloride were investigated. Both measurements and Monte Carlo simulations were performed in narrow beam geometry in an effort to determine mass attenuation coefficients. These mass attenuation coefficients were then utilized to compute the effective atomic numbers and effective electron densities of the selected materials. The present investigation is considered useful for selection of NLO materials to be used for biological dosimetry and other applications.
Experimental and computational methods
Experimental detials
Narrow beam transmission geometry was arranged, as shown in Fig. 1, to measure \(\mu _{\text {m}}\) for the NLO materials shown in Table 1. Six radioactive sources were used, namely, \(^{22}\hbox {Na}\), \(^{54}\hbox {Mn}\), \(^{57}\hbox {Co}\), \(^{60}\hbox {Co}\), \(^{133}\hbox {Ba}\), and \(^{137}\hbox {Cs}\). Gamma ray spectrometry was performed by means of a scintillation detector (\(2\times 2\) inch) to measure \(\mu _{\text {m}}\). The system showed an energy resolution of \(8.2\%\) at 662 keV and included a 16K multichannel analyzer (MCA). All samples were shaped as pellets with different thicknesses of 0.5–1.5 cm, and then irradiated by gamma ray energies of 122, 356, 511, 662, 840, 1170, 1275, and 1330 keV. The radioactive sources were within a lead cylinder with a 0.52 cm orifice to collimate and produce a pencil beam. The detector was also housed in a lead shield to minimize any background radiation. The spectrometer was calibrated using the 356.1 keV line emitted by \(^{133}\hbox {Ba}\), the 122 keV line emitted by \(^{57}\hbox {Co}\), the 511 and 1275 keV lines emitted by \(^{22}\hbox {Na}\), the 661.9 keV line emitted by \(^{137}\hbox {Cs}\), the 840 keV line emitted by \(^{54}\hbox {Mn}\), and the 1173.2 and 1332.5 keV lines emitted by \(^{60}\hbox {Co}\). The laboratory temperature was kept constant at \(25^{\circ }\hbox {C}\) (\(77^{\circ }\hbox {F}\)). The distance between source and detector was kept 35 cm and the sample was placed in-between. Archimedes principle was utilized to obtain the density of the studied materials, where measurements were performed at room temperature with ethylene as the reference immersion liquid.
GEANT4 simulation
The GEANT4 code can be applied for simulation of a narrow beam geometry with various photon energies (Allison et al. 2016). Determination of mass attenuation coefficients for any compound or mixture requires knowledge on the chemical or elemental composition and density of the material. The GEANT4 simulation developed for the present study included a mono-energetic photon beam imposing on a sample, as shown in Fig. 2. The mass attenuation coefficients for the material under investigation were determined using the transmission method following Lambert’s Beer law (\({I}={I}_0\hbox {e}^{-\mu _{\text {m}}x}\)), where \({I}_0\) and I are the incident and attenuated photon intensity, respectively, \(\mu _{\text {m}}\) (in \(\hbox {cm}^2 \hbox {g}^{-1}\)) is the mass attenuation coefficient and x is the thickness of the studied material in \(\hbox {g}/\hbox {cm}^2\).
For the simulation of mass attenuation coefficients, an input file has been prepared including beam properties, irradiation parameters, sample compositions, and physical settings. A beam of \(10^6\) photons was simulated to attenuate in the NLO samples. The code was run to obtain the transmission values, \({I}/{I}_0\), for each of the investigated NLO samples.
Effective atomic number
Effective atomic numbers refer to the attenuation of photons, which occurs due to photon interactions with matter, is is given by the following ratio (Singh et al. 2014; Manohara et al. 2009):
where \(\sigma _{\text {a}}\) is the total atomic cross section and \(\sigma _{\text {e}}\) is the total electronic cross section. The total atomic cross section can be obtained from the mass attenuation coefficient as follows:
where \(\hbox {w}_i\) is the weight fraction of the ith element in the sample. The total electronic cross section is given by the following equation:
where \(N_{\text {A}}\) is Avogadro‘s number, \(f_i\) is the fractional abundance of the each constituent element given that \(\sum _{i}{f_i}=1\), \(Z_i\) is the atomic number, and \(A_i\) is the atomic weight.
Results and discussion
Mass attenuation coefficients for the selected NLO materials are shown in Fig. 3, while corresponding effective atomic numbers are shown in Fig. 4 . Effective atomic numbers as a function of effective electron density are shown in Fig. 5, and measured and simulated mass attenuation coefficients are compared in Table 2. In Table 3, effective atomic numbers of the investigated NLO materials, TLD materials, polymers, and various human tissues are compared.
Mass attenuation coefficients
Figure 3 shows the mass attenuation coefficients (\(\mu _{\text {m}}\)) versus photon energy for the investigated NLO materials as obtained by measurement and simulation, with photon energies ranging from 1 to 1400 keV. It is to be noted that the \(\mu _{\text {m}}\) values for NLO materials decrease with increasing photon energy down to about \(0.06\ \hbox {cm}^2/\hbox {g}\) at a photon energy of 1400 keV. It was found that the \(\mu _{\text {m}}\) values are lowest for ADP and highest for ZTC, in the photon energy region of interest. The variation of the mass attenuation coefficients with photon energy can be explained using the photoelectric effect, Compton scattering and pair production (Chantler 2000; Singh et al. 2014; Tonguc et al. 2018; Özdemir and Kurudirek 2009).
The observed behaviour of the \(\mu _{\text {m}}\) values with photon energy can be divided into three energy regions, i.e., low-energy (\({E}\le 100\ \hbox {keV}\)), intermediate-energy (\(0.1\le {E}<1022\ \hbox {keV}\)), and high-energy (\({E} \ge 1022\ \hbox {keV}\)). It is observed that in the low-energy region, the \(\mu _{\text {m}}\) values sharply decrease with increasing photon energy for all the selected NLO materials. In this low-energy region, the predominant interaction is described by the photoelectric effect, where photon interaction depends upon atomic number and photon energy. In the intermediate-energy region, the \(\mu _{\text {m}}\) values only slightly decrease with increasing photon energy because of Compton scattering. In fact, Compton scattering is found to be roughly independent upon photon energy. In contrast, in the high-energy region, the \(\mu _{\text {m}}\) values slightly increase and become constant due to pair-production being the dominant process. The highest \(\mu _{\text {m}}\) values among the selected NLO materials were found for ZTC, which obviously provides superior shielding properties for the investigated photon energies.
Table 2 compares measured and simulated mass attenuation coefficients. The table shows that both the measured and simulated coefficients are very close to each other within \(< 15\%\) of standard deviation. Therefore, it is concluded that GEANT4 simulations allow for an investigation of photon interaction processes in compound or complex materials. It is also concluded that GEANT4 simulations can replace experimental investigations of photon interaction with materials.
Effective atomic number and electron density
Figures 4 and 5 show effective atomic numbers (\(Z_{\text {eff}}\)) as a function of photon energy and effective electron density (\(N_{\text {eff}}\)), respectively. It is observed that the \(Z_{\text {eff}}\) values for ZTC are the highest, while those for ADP are the lowest. The observed dependence of \(Z_{\text {eff}}\) on photon energy is due to the dependence of \(Z_{\text {eff}}\) on the atomic number of constituent elements and their compositions (see Eqs. 2 and 3). As compared to ADP, ZCT contains higher atomic number elements with higher chemical abundance, and therefore, \(Z_{\text {eff}}\) values are also found to be higher. It is to be noted that the relation between \(Z_{\text {eff}}\) and \(N_{\text {eff}}\) is linear and \(Z_{\text {eff}}\) values increase with increasing \(N_{\text {eff}}\). Figure 4 shows a comparison of \(Z_{\text {eff}}\) values for the investigated NLO materials with those of water. It is found that the \(Z_{\text {eff}}\) values of ADP are comparable those of water. Therefore, in terms of dosimetry ADP can be considered as tissue equivalent.
In Table 3, \(Z_{\text {eff}}\) values of the invvestigated NLO materials are compared with those of TLD materials, polymers, and human tissues. It is observed that the \(Z_{\text {eff}}\) values of TLD materials, polymers, and human tissues are found comparable to those of the investiged NLO materials. Therefore, these NLO materials might be suitable for biological dosimetery and other radiation applications.
Conclusion
Mass attenuation coefficients for some NLO materials (potassium dihydrogen phosphate, ammonium dihydrogen phosphate, zinc tris-thiourea sulphate, and zinc thiourea chloride) were measured by using a NaI(Tl) detector for selected photon energies. GEANT 4 simulations were carried out to investigate the same parameters. As a result, good agreement between the experimental and simulated results was observed. Effective atomic numbers of the NLO materials were compared with those of TLD materials, polymers and human tissues, and found to be comparable . This suggests that the investigated NLO materials could be used for dosimetric applications. In addition, it is concluded that GEANT4 simulations offer an alternative for experimental investigations of photon interaction with matter.
References
Allison J, Amako K, Apostolakis J, Arce P, Asai M, Aso T, Bagli E, Bagulya A, Banerjee S, Barrand G et al (2016) Recent developments in Geant4. Nucl Instrum Methods Phys Res Sect A Accel Spectrom Detect Assoc Equip 835:186
Awasarmol VV, Gaikwad DK, Raut SD, Pawar PP (2017) Photon interaction study of organic nonlinear optical materials in the energy range 122–1330 keV. Radiat Phys Chem 130:343
Bootjomchai C, Laopaiboon R (2014) Thermoluminescence dosimetric properties and effective atomic numbers of window glass. Nucl Instrum Methods Phys Res Sect B Beam Interact Mater Atoms 323:42
Chantler CT (1995) Theoretical form factor, attenuation, and scattering tabulation for \(\text{ Z }= 1\)–92 from \(\text{ E }= 1\)–10 eV to \(\text{ E }= 0.4\)–1.0 MeV. J Phys Chem Ref Data 24(1):71
Chantler CT (2000) Detailed tabulation of atomic form factors, photoelectric absorption and scattering cross section, and mass attenuation coefficients in the vicinity of absorption edges in the soft X-ray (\(\text{ Z }= 30\)–36, \(\text{ Z }= 60\)–89, \(\text{ E }= 0.1\ \text{ keV }\)–10 keV), addressing convergence issues of earlier work. J Phys Chem Ref Data 29(4):597
Dini D, Calvete MJ, Hanack M (2016) Nonlinear optical materials for the smart filtering of optical radiation. Chem Rev 116(22):13043
Gowda S, Krishnaveni S, Yashoda T, Umesh T, Gowda R (2004) Photon mass attenuation coefficients, effective atomic numbers and electron densities of some thermoluminescent dosimetric compounds. Pramana 63(3):529
Hine G (1951) The effective atomic numbers of materials for various gamma ray processes. Phys Rev 82:725
Hubbell JH, Seltzer SM (1995) Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements \(\text{ Z }= 1\) to 92 and 48 additional substances of dosimetric interest. Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 kev to 20 mev for elements \(\text{ z }= 1\) to 92 and 48 additional substances of dosimetric interest. Tech. rep., National Inst. of Standards and Technology-PL, Gaithersburg, MD (United)
Kucuk N, Manohara S, Hanagodimath S, Gerward L (2013) Modeling of gamma ray energy-absorption buildup factors for thermoluminescent dosimetric materials using multilayer perceptron neural network: A comparative study. Radiat Phys Chem 86:10
Kumar TK, Reddy KV (1997) Effective atomic numbers for materials of dosimetric interest. Radiat Phys Chem 50(6):545
Kurudirek M (2014) Effective atomic numbers and electron densities of some human tissues and dosimetric materials for mean energies of various radiation sources relevant to radiotherapy and medical applications. Radiat Phys Chem 102:139
Lin Z, Jiang X, Kang L, Gong P, Luo S, Lee MH (2014) First-principles materials applications and design of nonlinear optical crystals. J Phys D Appl Phys 47(25):253001
Liu X, Guo Q, Qiu J (2017) Emerging low-dimensional materials for nonlinear optics and ultrafast photonics. Adv Mater 29(14):1605886
Manohara S, Hanagodimath S, Gerward L (2009) The effective atomic numbers of some biomolecules calculated by two methods: a comparative study. Med Phys 36(1):137
Manohara S, Hanagodimath S, Gerward L (2010) Energy absorption buildup factors for thermoluminescent dosimetric materials and their tissue equivalence. Radiat Phys Chem 79(5):575
McNair A (1981) ICRU report 33-radiation quantities and units pub: international commission on radiation units and measurements, Washington DC USA issued 15 April 1980, pp. 25. J Label Compd Radiopharm 18(9):1398
Özdemir Y, Kurudirek M (2009) A study of total mass attenuation coefficients, effective atomic numbers and electron densities for various organic and inorganic compounds at 59.54 keV. Ann Nucl Energy 36(11–12):1769
Ramprasath V et al (2000) Effective atomic numbers for photon energy absorption and energy dependence of some thermoluminescent dosimetric compounds. Nucl Instrum Methods Phys Res Sect B Beam Interact Mater Atoms 168(3):294
Shivaramu (2002) Effective atomic numbers for photon energy absorption and photon attenuation of tissues from human organs. Med Dosim 27(1):1
Sidhu BS, Dhaliwal A, Mann K, Kahlon K (2012) Study of mass attenuation coefficients, effective atomic numbers and electron densities for some low Z compounds of dosimetry interest at 59.54 keV incident photon energy. Ann Nucl Energy 42:153
Singh VP, Badiger N (2016) Studies on photon buildup for some thermoluminescent dosimetric compounds. Indian J Phys 90(3):259
Singh VP, Badiger N, Kucuk N (2014) Assessment of methods for estimation of effective atomic numbers of common human organ and tissue substitutes: waxes, plastics and polymers. Radioprotection 49(2):115
Singh VP, Medhat M, Badiger N (2014) Photon attenuation coefficients of thermoluminescent dosimetric materials by Geant4 toolkit, XCOM program and experimental data: a comparison study. Ann Nucl Energy 68:96
Singh VP, Shirmardi S, Medhat M, Badiger N (2015) Determination of mass attenuation coefficient for some polymers using Monte Carlo simulation. Vacuum 119:284
Swinehart D (1962) The Beer–Lambert law. J Chem Educ 39(7):333
Taylor M, Franich R, Trapp J, Johnston P (2008) The effective atomic number of dosimetric gels. Austral Phys Eng Sci Med 31(2):131
Tonguc BT, Arslan H, Al-Buriahi MS (2018) Studies on mass attenuation coefficients, effective atomic numbers and electron densities for some biomolecules. Radiat Phys Chem 153:86
Acknowledgements
The corresponding author would like to express his deep appreciation to Prof. Werner Ruhm, Institute of Radiation Protection, Helmholtz Zentrum München, Neuherberg, Germany for his an excellent corrections and suggestions to improve the present work.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Al-Buriahi, M.S., Singh, V.P., Arslan, H. et al. Gamma-ray attenuation properties of some NLO materials: potential use in dosimetry. Radiat Environ Biophys 59, 145–150 (2020). https://doi.org/10.1007/s00411-019-00824-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00411-019-00824-y