Abstract
Introduction
Metal-on-metal bearings for total hip arthroplasty are increasing in popularity. However, metal ion toxicity, metal hypersensitivity, and metal carcinogenicity are the causes concern for patients with metal-on-metal hip replacement. We investigated serum levels of cobalt and chromium ions in patients with successfully implanted second-generation metal-on-metal total hip arthroplasty (THA) using PINNACLE-A (DePuy, Warsaw, IN, USA).
Materials and methods
Thirty-three patients underwent primary cementless THA with the use of a 36-mm femoral head PINNACLE-A with a metal-on-metal articulation. Blood samples were taken preoperatively, at 3 months, and at 1 year, and levels of cobalt and chromium were determined.
Results
At 3 months, levels of both cobalt and chromium had increased significantly compared with preoperative levels. There were no significant differences between levels of either metal at 3 months and 1 year.
Conclusion
Patients with metal-on-metal THA had higher circulating levels of metal ions than before arthroplasty at 3 months, with no additional significant increases at 1 year in this study.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Metal-on-metal bearings are being increasingly used in total hip arthroplasty (THA) and hip resurfacing with the understanding that reduced wear and osteolysis will improve long-term survival [1]. However, the possible complications resulting from the dissemination of metal particles and ions throughout the body are likely cause of patient anxiety. The particles are nanometers in size and high in number, and their dissolution results in measurable increases in cobalt and chromium ions in serum, urine, and red blood cells of patients with a metal-on-metal bearing [2]. We investigated serum levels of cobalt and chromium ions in patients with successfully implanted second-generation metal-on-metal THA using PINNACLE-A (DePuy, Warsaw, IN, USA) [3, 4].
Materials and methods
From December 2006 to April 2008, 85 consecutive primary THA procedures using PINNACLE-A were performed in our department. Study exclusion criteria included the presence of other metallic implants, metal allergy, pregnancy, and renal insufficiency. This resulted in 33 patients being included in the study, including 4 men and 29 women. The mean age of participants was 60 years (range, 41–83 years), and the mean body mass index was 25 (range, 18–34). The preoperative diagnosis was osteoarthritis in 30 patients and rheumatoid arthritis in 3 patients. Demographic data are shown in Table 1.
All patients underwent primary cementless THA with the use of a 36-mm femoral head PINNACLE-A with a metal-on-metal articulation [3, 4]. S-ROM-A (DePuy) was used in the femoral stem. The acetabular component was made of wrought-forged, high-carbon content cobalt–chromium alloy (0.35% C) with a diametric bearing clearance of 80–120 µm. The mean diameter of the acetabular component was 54 mm (range, 52–58 mm). The acetabular component inclination angle was measured on anteroposterior pelvic radiographs. The inclination angle was defined as the angle between the line joining the inferior teardrop points and the axis of opening of the acetabular component. The mean inclination angle was 49° (range, 32°–70°). Clinical evaluation was performed using the Japanese Orthopaedic Association (JOA) score [5]. The JOA score carries a maximum score of 100, with scales to evaluate pain (0–40 points), range of movement (0–20 points), walking ability (0–20 points), and activities of daily living (0–20 points) [5]. This study was approved by our institution’s Ethics Committee, and all patients gave informed consent.
Twelve milliliters of blood samples was taken preoperatively, at 3 months, and at 1 year after surgery using cobalt-free needles and glass tubes for trace metal analysis without additives for blood collection to avoid metal contamination. Blood samples were submitted for analysis by Mitsubishi Chemistry Medience Co., Ltd. (Tokyo, Japan), and serum samples were stored at −20°C in inert polystylene tubes until assayed. Levels of cobalt were determined by Inductively Coupled Plasma Mass Spectrometry (Perkin-Elmer SCIEX Elan 6100 DRC ICP-MS system; Perkin-Elmer Instruments, Norwalk, CT, USA) at Mayo Medical Laboratories. The detection limit of the method was estimated to be 0.2 µg/L. Levels of chromium were determined using a graphite furnace atomic absorption spectrometer (Z-5700; Hitachi Ltd., Tokyo, Japan) with polarization-Zeeman absorption. The detection limit of the method was estimated to be 0.2 µg/L. All concentrations below that limit were defined as 0.2 µg/L for both cobalt and chromium to allow for statistical calculation.
Statistical analysis was performed using the Wilcoxon signed rank test to compare preoperative and postoperative JOA scores. For each time-point, the median as well as the 25th and 75th percentiles of cobalt and chromium concentrations was calculated. We used the median concentrations of cobalt and chromium, and applied the Wilcoxon signed rank test for comparisons over time. The acetabular component inclination, the cup diameter, the age of the patient, body mass index, and JOA score were correlated with serum concentrations of cobalt and chromium using the Spearman correlation coefficient. Statistical significance was set at P < 0.05.
Results
The JOA score improved significantly from 45 points (range, 22–73 points) preoperatively to 76 points (range, 56–97 points) at 3 months (P < 0.001) and 80 points (57–100 points) at 1 year (P < 0.001).
Pre- and postoperative serum concentrations of cobalt and chromium are summarized in Fig. 1. The median preoperative serum cobalt concentration was 0.3 µg/L. At 3 months, cobalt levels (0.7 µg/L) had increased significantly compared with preoperative levels (P < 0.001). There was no significant difference between cobalt levels at 3 months and 1 year (1.1 µg/L; P = 0.1301). The median preoperative serum chromium concentration was 0.3 µg/L. At 3 months, chromium levels had increased significantly (0.6 µg/L) compared with preoperative levels (P < 0.001). There was no significant difference between the chromium levels at 3 months and 1 year (0.8 µg/L; P = 0.0854).
Neither the acetabular component inclination, cup diameter, nor the age of the patient, body mass index, or JOA score showed a significant correlation with cobalt and chromium serum concentrations in the present study.
Discussion
There are limited data available on systemic metal concentrations in patients implanted with PINNACLE-A [6–8]. Antoniou et al. [6] reported a comparison of the serum metal ion levels between the 28- and 36-mm head metal-on metal-prostheses. At 6 months, serum metal levels for the 36-mm femoral head with a metal-on-metal articulation PINNACLE-A was 1.8 µg/L for cobalt and 0.25 µg/L for chromium. At 1 year, the serum metal level of cobalt was 2.3 µg/L and that of chromium was 0.4 µg/L. Isaac et al. [8] measured the whole blood metal ion levels with 28-mm head metal-on-metal prostheses. The median cobalt and chromium levels were 0.83 and 0.66 µg/L at 1 year.
The levels of both cobalt and chromium in our study were lower than levels reported in previous studies of different types of metal-on-metal bearings [9–12]. In contrast, serum metal levels of cobalt and chromium for the 28-mm Metasul bearing (Zimmer, Warsaw, IN) were similar to those found in previously reported investigations for modern, second-generation metal-on-metal bearings [13, 14].
Recent study evaluated the release of metal ions after metal-on-metal total disc arthroplasty [15]. The average concentrations in the serum were 4.8 µg/L for cobalt and 1.9 µg/L for chromium after average follow-up of 15 months [15]. The levels were similar or higher than the levels shown in the literature following implantation of total hip endoprosthetics with metal-on-metal bearings [6–14].
In terms of acetabular component inclination, we found no significant correlation between cobalt and chromium serum concentrations. Vendittoli et al. [16] was also unable to draw strong conclusions regarding the acetabular inclination and levels of cobalt. On the other hand, some authors [17, 18] reported significantly higher levels of metal ions in patients with steeply inclined components. In our study, there was no significant correlation between patient activity, as assessed using activities of daily living score of the JOA score [5] and serum metal levels. This is in agreement with recent results showing that metal ion levels are not acutely affected by patient activity [16, 17, 19]. However, another study showed a mild increase in levels of cobalt but not chromium following exercise [20].
Despite concerns regarding chromosome aberrations and translocations, the International Agency for Research on Cancer concluded that there is inadequate evidence in humans regarding the carcinogenicity of orthopaedic implants [6]. Metal-on-metal bearings often are not recommended in women of child-bearing age because of the theoretical risk of metal ion exposure to the fetus [21]. Data from Nordic registries are used to estimate adverse effects on a large scale, based mostly on metal-on-polyethylene bearings, and cancer incidence was in line with the general population [2]. Elevated ion levels have been associated with an increased prevalence of chromosomal changes, suggesting a possible carcinogenic effect [21, 22].
Our results showed that patients with metal-on-metal total hip prostheses had higher circulating levels of metal ions than before arthroplasty at 3 months, with no additional significant increases at 1 year; however, future, follow-up studies will investigate the long-term concentration of metal ions.
References
Cobb AG, Schmalzreid TP (2006) The clinical significance of metal ion release from cobalt–chromium metal-on-metal hip joint arthroplasty. Proc Inst Mech Eng 220:385–398
Visuri TI, Pukkala E, Pulkkinen P, Paavolainen P (2006) Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings. Proc Inst Mech Eng 220:399–407
Engh CA, Hopper RH Jr, Engh CA Jr (2004) Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 19(7 Suppl 2):54–60
Powers CC, Ho H, Beykirch SE, Huynh C, Hopper RH Jr, Engh CA Jr, Engh CA (2009) A comparison of a second- and a third-generation modular cup design is new improved? J Arthroplasty. April 8. [Epub ahead of print]
Ohashi H, Hirohashi K, Yamano Y (2000) Factors influencing the outcome of Chiari pelvic osteotomy: a long-term follow-up. J Bone Joint Surg Br B 82-B:517–525
Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL (2008) Metal ion levels in the blood of patients after hip resurfacing: A comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am A 90(Suppl 3):142–148
Williams S, Schepers A, Isaac G, Hardaker C, Ingham E, van der Jagt D, Breckon A, Fisher J (2007) Ceramic-on-metal hip arthroplasties: a comparative in vitro and in vivo study. Clin Orthop Relat Res 465:23–32
Isaac GH, Brockett C, Breckon A, van der Jagt D, Williams S, Hardaker C, Fisher J, Schepers A (2009) Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components. J Bone Joint Surg Br 91(9):1134–1141
Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A (2002) Ion release in patients with metal-on-metal hip bearings in total joint replacement:a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 63:467–474
Clarke MT, Lee PTH, Arora A, Villar RN (2003) Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty. J Bone Joint Surg Br B 85:913–917
Witzleb W, Ziegler J, Krummenauer F, Neumeister V, Guenther K (2006) Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 77:697–705
Moroni A, Savarino L, Cadossi M, Baldini N, Giannini S (2008) Does ion release differ between hip resurfacing and metal-on-metal THA? Clin Orthop Relat Res 466:700–707
Brodner W, Bitzan P, Meisinger V, Kaider A, Gottsauner-Wolf F, Kotz R (2003) Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am A 85:2168–2173
Hur CI, Yoon TR, Cho SG, Song EK, Seon JK (2008) Serum ion level after metal-on-metal THA in patients with renal failure. Clin Orthop Relat Res 466:696–699
Zeh A, Becker C, Planert M, Lattke P, Wohlrab D (2009) Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick type artificial lumbar disc (Medtronic Sofamor Danek). Arch Orthop Trauma Surg 129(6):741–746
Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M (2007) Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br B 89:441–448
Haan RD, Pattyn C, Gill HS, Murray DW, Campbell PA, Smet KD (2008) Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br B 90:1291–1297
Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV (2008) The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br B 90:1143–1151
Heisel C, Silva M, Skipor AK, Jacobs JJ, Schmalzried TP (2005) The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg Am A 87:781–787
Kahn M, Kuiper JH, Richardson JB (2008) The exercise-related rise in plasma cobalt levels after metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg Br B 90:1152–1157
Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP (2004) Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 19(8 Suppl 3):78–83
Dunstan E, Ladon D, Whittingham-Jones P, Carrington R, Briggs TW (2008) Chromosomal aberrations in the peripheral blood of patients with metal-on-metal hip bearings. J Bone Joint Surg Am A 90:517–522
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Imanishi, T., Hasegawa, M. & Sudo, A. Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty. Arch Orthop Trauma Surg 130, 1447–1450 (2010). https://doi.org/10.1007/s00402-010-1056-9
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00402-010-1056-9