Abstract
Background
Colorectal cancer (CRC) is a leading cause of death, and necessitates a conjointly performed staging. Until now, a multi-step-examination including optical colonoscopy, cross-sectional and functional imaging is recommended. However, a single examination for whole-body staging with a dedicated CRC staging protocol is desirable. Thus, we developed and evaluated a combined whole-body PET/CT-colonography protocol for dedicated CRC staging in routine clinical use.
Methods
We integrated CT-colonography into a whole-body PET/CT protocol to achieve a specific “all-in-one” examination for patients suspected of having CRC. After oral and rectal bowel distension, PET/CT-colonography has been performed in 55 patients. All patients had optical colonoscopy one day before PET/CT. PET/CT data sets were evaluated concerning detection and evaluation of colorectal tumour sites, lymph nodes and distant metastases; these results were compared to the results of CT-colonography alone. Surgical resection and/or biopsy served as standards of reference in all patients.
Results
All examinations were fully diagnostic and well tolerated by the patients. PET/CT-colonography showed highly accurate results for overall TNM-evaluation and was significantly more accurate than CT-colonography alone.
Conclusions
Staging patients with whole-body PET/CT-colonography is technically feasible and accurate. Patients with incomplete colonoscopy or potential synchronous bowel lesions might benefit from this approach.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Colorectal cancer (CRC) continues to be the third leading cause of cancer-related mortality in the western countries accounting for over 50,000 deaths in 2005 [1].
For patients with CRC, accurate tumour staging is an indispensable condition for planning and success of their therapy [2–6]. In clinical routine, optical colonoscopy continues to be the standard method of choice for diagnosis, allowing not only for the tumour detection but also for tissue biopsies. Furthermore, synchronous lesions can be excluded if the bowel is adequately prepared. Additionally non-invasive imaging techniques have to be performed to determine potential metastases to the lymphatic system or other organs.
Within a variety of different imaging procedures, contrast-enhanced computed tomography (CT) turned out to be one of the most commonly used modality for staging CRC patients. It not only offers the possibility of visualizing the primary tumour, but also gives an overview over adjacent and distant organs concerning potential metastases. CT-colonography and optimized abdominal CT are widely accepted techniques which have been investigated for several indications [7–9]. Recent studies have demonstrated that CT imaging has a high sensitivity for detecting medium and large colorectal polyps as well as symptomatic cancer [10, 11]. A major drawback of CT is the lack of functional data, which may be of help not only in the detection of the tumour but also in the evaluation of potential invasion of the tumour into adjacent organs and in the detection of metastatic spread to regional lymph nodes [12]. [18F]-Fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) can display functional information and has been found to be particularly accurate in staging primary and recurrent CRC, but has a limited anatomical resolution [13–18].
A combination of CT and PET in a combined PET/CT scanner allows for fusion of functional and morphological data and has been used in clinical practice for several years. Recent studies demonstrated the superiority of the combined-imaging modality for the detection and characterization of malignant lesions of different malignancies including CRC when compared with CT or PET alone [19–21].
Non-disease-defined PET/CT protocols may, however, not be specific enough to evaluate the cancer entity in all its supplementary aspects. Therefore, a protocol with focus on CRC staging has been included in a whole-body PET/CT protocol and has demonstrated promising initial results concerning technical feasibility and tumour detection rates [22]. In addition, by performing PET/CT as a whole-body imaging procedure including PET/CT-colonography the stepwise, multi-modality diagnostic workup can be shortened and can therefore be used as an “all-in-one” imaging approach in conjunction with optical colonoscopy. This article provides an update about our ongoing research in that field.
Patients and methods
Patients
Our experience with PET/CT-colonography is based on 55 patients. Patients were scheduled for examination based on the following symptoms: BRBPR (bright red blood per rectum), positive faecal occult blood test, long lasting altered bowel habits and anaemia of unknown cause. All patients underwent optical colonoscopy one day prior to the PET/CT examination and were referred for staging based on suspected CRC.
Patient preparation and PET/CT imaging procedure
Before optical colonoscopy, all patients received bowel cleansing with polyethylene glycol-electrolytes (PEG-ES, Braintree Laboratories Inc., Braintree, MA, USA). Afterwards, patients were kept on clear liquids for the PET/CT examination on the following day. Dual modality imaging was performed with a commercially available PET/CT system (Siemens Molecular Imaging, Hoffman Estates, IL, USA). The system includes a dual-slice CT scanner (Somatom Emotion, Siemens Medical Solutions, Forchheim, Germany) and a full ring PET tomograph (ECAT HR+, Siemens Medical Solutions, Hoffman Estates, IL, USA). The PET system has an axial field of view of 15.5 cm per bed position and an in-plane spatial resolution of 4.6 mm. The system acquires the CT first, followed by the emission data. CT and PET data sets can be viewed separately or in fused mode on a commercially available computer workstation (Siemens Molecular Imaging, Erlangen, Germany) after the examination.
Prior to the FDG injection, blood samples were drawn from all patients to assure glucose levels to be in normal range. Afterwards, a mean of 340 MBq of FDG were administered intravenously to all patients. During the uptake time of 60 min, 1500 mL of a water-based, negative oral contrast agent was applied for small bowel distention [23].
The PET/CT protocol, which covered a field of view from the base of the skull to the upper thighs, was divided into two parts: First, data from the upper body regions (base of skull to diaphragm) were acquired in a caudo-cranial direction with the patient in supine position using a standardized breathing protocol [24]. CT images were acquired with 110 mAs, 120 kV, 5 mm slice thickness and a 2.4 mm incremental reconstruction. For intravenous contrast, 60 mL of an iodinated contrast agent (300 mmol/mL, Guerbet GmbH, Sulzbach, Germany) were administered. The PET data were acquired with the same field of view as the CT. After this first imaging part, all patients received pharmacological bowel relaxation (20 mg of N-butylscopolamin, Buscopan®, Boehringer Ingelheim GmbH, Ingelheim, Germany) by bolus injection and were placed in a prone position on the scanner table. Hereafter, a water enema (2–3 L tap water, 37°C) via an inflatable rectal balloon catheter was applied for colonic distension. With an additional short intravenous infusion of 20 mg of N-butylscopolamin solved in 50 mL sodium chloride (0.9%) continuous bowel relaxation was assured during the second imaging part. During the second part of the acquisition, corresponding PET/CT data were acquired from the diaphragm to the upper thighs with the patient in prone position. For intravenous contrast, 90 ml of an iodinated contrast agent were administered. CT image acquisition was performed at 120 kV, 3 mm slice thickness and 2.4 mm incremental reconstruction, whereas the tube current was individually adjusted with respect to the diameter of the patient. PET imaging was acquired covering the same field of view. Average PET acquisition time was 3–4 min, depending on the weight of the patient. In both scan portions emission data were corrected for scatter and attenuation based on the available CT transmission images. Corrected PET images were reconstructed iteratively (FORE-OSEM, 2 iterations, 8 subsets, 128 × 128 matrix with 5 mm Gaussian smoothing).
Image evaluation
In a first step, the evaluation of bowel distension for six segments of the colon (rectum, sigmoid, descending colon, transverse colon, ascending colon and caecum) was performed according to a 4-point scale: Grade 0 represents a totally collapsed bowel, grade 1 a partially collapsed colon, grade 2 a reasonably, but suboptimally distended colon and grade 3 an optimal colonic distension with a barely visible colonic wall according to published criteria [25].
All PET/CT data sets were reviewed in fused mode and 3D mode on a dedicated fusion workstation (syngoTM software, Siemens Medical Solutions, Erlangen, Germany) by a radiologist and a nuclear medicine specialist in consensus. PET data sets were evaluated with and without attenuation correction.
Contrast-enhancing, bowel wall masses in conjunction with focally increased glucose metabolism above the surrounding tissue level were considered malignant. A standardized uptake value (SUV max) of more than 2.5 on PET/CT supported the diagnosis. Lymph nodes were assessed for metastatic spread based on increased glucose metabolism independent of their size on PET/CT. Furthermore, a fatty hilum as well as calcifications indicated a benign lymph node, whereas lymph nodes with central necroses were evaluated as malignant, independent of their size and glucose uptake. Distant metastases were assessed based on a soft tissue, contrast-enhancing mass in different body compartments with or without focally increased glucose metabolism above the surrounding tissue level on PET/CT images. For the CT-image evaluation, the same criteria than in PET/CT (without evaluation of corresponding glucose metabolism) were used for T-evaluation and M-evaluation. Image evaluation for N-staging was size-based, using a standard threshold of 1 cm for malignant lymph nodes.
The standard of reference was based on the histopathological workup after surgery or at least histopathological workup of biopsy material from optical colonoscopy in all patients.
Results
Patients
Fifty-five patients have been investigated with the PET/CT-colonography protocol. Forty-nine patients were operated on after PET/CT staging, one patient received additional biopsy but no further surgery. Five patients received palliative treatment based on PET/CT findings and were excluded from the evaluation. Three patients received neoadjuvant chemotherapy and/or radiotherapy prior to surgery. Four patients had no tumour according to the standard of reference. All patients tolerated the PET/CT-procedure well. Two patients had mild nausea after the procedure.
Feasibility of PET/CT procedure with integrated colonography
All PET/CT examinations with integrated colonography delivered fully diagnostic image quality for the colonography data sets and whole-body tumour staging in all patients. The average time for the combined examination amounted to 37 min (±6 min) representing 7–11 bed positions per examination. In comparison, a non-colonography PET/CT examination in our institution required on average 32 min (±7 min). The bowel distension with tap water showed good results based on the 4-grade scale with an average score of 2.6 (rectum and sigmoid colon), 2.5 (descending colon and transverse colon), 2.5 (ascending colon) and 2.4 (caecum) (Fig. 1).
PET/CT-colonography staging results
PET/CT-colonography showed highly accurate staging results concerning the overall TNM-staging: 37/50 patients were correctly classified (74%). T-stage was correct in 42/50 patients (84%) with PET/CT (Fig. 2). According to the standard of reference, these were T0 in 4 patients, T1 in 4 patients, T2 in 6 patients, T3 in 31 patients and T4 in 5 patients. The N-stage was correctly classified with PET/CT in 41/50 patients (82%). According to the standard of reference N-stages were N0 in 28 patients, N1 in 16 patients, N2 in 6 patients. PET/CT-Colonography showed a statistically significant improved staging compared to CT-colonography. Overall TNM staging was correct in 22/50 patients (44%) with CT staging alone (P < 0.05). T-staging with CT-colonography was correct in 35/50 patients (70%), N-staging was correct in 34/50 (68%). No significant difference was found for the M-staging.
Four patients had negative staging results: two patients were suspected of having residual colonic tumour after endoscopical resection. On CT images alone, a slightly thickened bowel wall would have indicated residual tumour. PET/CT was able to classify the area in question as scar formation due to the lack of elevated glucose metabolism. In another patient, a recurrence at the rectal anastomosis was suspected based on a severe rectal stenosis. PET/CT in this patient showed no or only minor glucose uptake in this mass; thus, it was evaluated as scar tissue on PET/CT which was confirmed by biopsy (Fig. 3). One patient showed several colon lesions with elevated glucose metabolism, which were evaluated as colon cancer on PET/CT (Fig. 4). However, these lesions turned out as adenomas with intraepithelial dysplasia, but without cancerous’ growth. Thus, PET/CT was falsely positive concerning tumour detection.
One flat adenoma adjacent to the iliocaecal valve was detected neither on PET/CT-colonography nor on CT-colonography but was detected by optical colonoscopy.
Concomitant findings
Nine patients undergoing PET/CT-colonography had an incomplete optical colonoscopy due to insufficient bowel cleansing, tumourous stenosis and/or bleeding. PET/CT-colonography detected an additional colorectal tumour in the ascending colon in one of these patients. No additional benign or malignant lesions were detected in any of the other patients.
Whole-body PET/CT detected six extra colonic tumour sites of which five were unknown. Three patients had liver metastases, one patient had an additional breast cancer, one patient had a thyroid cancer and one patient had a synchronous hepato-cellular carcinoma (HCC).
Discussion
The concept of whole-body PET/CT-colonography demonstrated high detection rates for colorectal lesions, malignant lymph nodes and distant metastases.
Thus, whole-body PET/CT-colonography is feasible as an “all-in-one” staging modality in patients with CRC and might potentially replace the multi-modality, multi-step “conventional” staging concept. However, in this update, we did not evaluate the therapeutic consequences of PET/CT over CT-staging alone. This potential effect of PET/CT-colonography on patient management has been evaluated in a previous study by our group and a change in the therapy regimen was detected in 9% of patients [26].
Technical considerations
To avoid image misregistration due to bowel movement during the acquisition time of approximately 15 min, bowel relaxation has to be ensured with a bolus injection and, if required, a short infusion of N-butylscopolamine when exceeding 15 min acquisition time. As this drug is not FDA approved, glucagon may be used for bowel relaxation instead in the US. However, we do not have any experience with glucagon in the setting of PET/CT-colonography
Our protocol used tap water for colon distension. For CT-colonography or abdominal CT for CRC staging, room air or CO2 is used more frequently. The main reason for higher patient comfort is intestinal absorption of the gas [27, 28]. However, gas absorption can lead to differences in bowel distension and can possibly result in misregistration of morphological and functional data. Thus, water was used for bowel distension part of our study. Meanwhile, we have examined a limited number of patients with room air for bowel distension. A higher degree of misregistration was detected between morphological and functional data in these patients. Additionally, based on the greater difference of Hounsfield Units between the colonic wall and the gas-filled colon, mild streak artefacts occurred on the colon wall surface, which potentially impair the evaluation of small and/or flat lesions. We conducted the room–air inflation manually. A protocol using an automatic insufflator may help to reduce misregistration artefacts, but will further increase costs and will be more time consuming as well.
We acquired the abdominal PET/CT in prone position, albeit knowing that scanning in both positions (prone and supine) may provide better colonic distension [29–31]. Additionally, scanning in both positions is needed in CT-colonography to distinguish between residual stool and polyps. Differentiation of stool and colonic wall lesions does not cause any difficulties with PET/CT based on the additionally available functional data. Furthermore, previous studies have demonstrated similar accuracy in polyp detection comparing prone/supine scanning with scanning in a prone position only [29]. Therefore, the PET/CT-colonography protocol included scanning in prone position only.
We conducted our examination on a dual slice CT scanner. Despite the fact that multi-detector scanners provide the option of acquisition of thinner slices, recent studies have demonstrated that there may not be a significant difference in the detection of small intestinal masses comparing single and multi-detector scanners [32]. However, single-slice or dual-slice CT may go along with a higher rate of artefacts in post-processing and a higher radiation dose. For evaluation of CT-colonography, data sets are often reviewed with specific post-processing software applications such as virtual colonoscopy [33, 34]. For PET/CT-colonography, or PET/CT in general, there is no equivalent software currently commercially available from any of the major vendors, i.e., for virtual colonoscopy or. Therefore, PET/CT-colonography images are assessed by fused axial as well as 3D-MPR images. Different PET/CT research groups have been working on post-processing tools, but none has been available commercially yet [35].
In our initial study, the in-room time for the PET/CT-colonography procedure amounted to 37 min (mean in-room time). Considering a shorter emission time (e.g., 2 min emission time/bed position) which is used in other PET/CT imaging centres, the scanning time can be shortened substantially. Taking into account new scanners with extended field-of-views (22 cm vs. 15.5 cm/bed position), the overall in-room time for a colon-specific whole-body PET/CT-colonography staging procedure can be as short as 15 min.
Staging considerations
Overall TNM staging in PET/CT was accurate in this patient population. However, the results for the T-stage and the M-stage are comparable to those with CT-colonography results in the literature [3]. One reason for similar staging accuracies may be the patient population which included higher (mainly T3) T-stages. A T3 stage can be evaluated accurately with CT alone in most patients, because surrounding soft tissue infiltration deriving from the colonic wall can be detected well. This holds true especially for the ascending colon, transverse colon and descending colon where facility of inspection is better than in the cecum, the sigmoid colon or the rectum. Greater advantages of PET/CT therefore may derive in larger patient populations from the detection of small colonic wall lesions and evaluation of surrounding organ infiltration in the mentioned colon sections.
A second reason for similar staging accuracies compared to the CT-literature may be a considerable amount of N0-patients in our patient population. Since PET/CT has a clear advantage over CT alone in the detection of metastastic lymph nodes, stages with lymph node involvement might be evaluated with a higher accuracy 36]. However, studies addressing this issue are required.
PET/CT detected several lesions with elevated glucose metabolism which turned out to be adenomas with intraepithelial dysplasia rather than cancer. The detection and characterization of intraepithelial dysplasia with PET is a controversial topic in the current literature, and the experience with PET/CT in this setting is small [37–39]. However, PET alone and non-disease defined PET/CT can be impaired by unspecific focal glucose uptake of the colon [40]. Based on pharmacological bowel relaxation, the risk for unspecific intestinal glucose metabolism on PET/CT-colonography must be considered low. Thus, if focally increased glucose metabolism is detected in the intestinal wall on PET/CT-colonography further clinical workup is required.
Possible indications and perspectives
PET/CT-colonography is not only feasible, but also shows highly accurate tumour detection rates and promising staging results. Thus, patients with incomplete colonoscopy and suspected CRC may benefit from this approach. The protocol may also be used for the detection of small synchronous lesions and distant metastases. PET/CT is also known for superior detection rates concerning metastatic lymph nodes; therefore it might be helpful especially in rectal cancer where node-positive patients often receive preoperative chemotherapy. At last, the protocol might also be feasible for the evaluation of local tumor recurrence. In these cases, diagnosis by optical colonoscopy is often impaired due to scar stenosis or tumour growth outside of the anastomosis. The same holds true for colon stenosis caused by the primary tumour. In these cases PET/CT-colonography can provide whole-body staging and evaluation of the colon proximal to the stenosis.
Further studies have to evaluate these potential benefits of PET/CT-colonography. In summary, it is the authors’ opinion that whole-body PET/CT-colonography can serve as a useful tool in conjunction with optical colonoscopy as an “all-in-one” staging procedure in patients with suspected CRC.
References
Jemal A, Murray T, Ward E, et al. (2005) Cancer statistics, 2005. CA Cancer J Clin 55:10–30
Bipat S, Glas AS, Slors FJM, et al. (2004) Rectal cancer: local staging and assessment of lymph node involvement with endoluminal US, CT, and MR imaging—a meta-analysis. Radiology 232:773–783
Filippone A, Ambrosini R, Fuschi M, et al. (2004) Preoperative T and N staging of colorectal cancer: accuracy of contrast-enhanced multi-detector row CT colonography–initial experience. Radiology 231:83–90
Neri E, Giusti P, Battolla L, et al. (2002) Colorectal cancer: role of CT colonography in preoperative evaluation after incomplete colonoscopy. Radiology 223:615–619
Stevenson GW (2000) 1998 RSNA annual oration in diagnostic radiology: colorectal cancer imaging: a challenge for radiologists. Radiology 214:615–621
Schofield JB, Mounter NA, Mallett R, Haboubi NY (2006) The importance of accurate pathological assessment of lymph node involvement in colorectal cancer. Colorectal Dis 8:460–470
Andersen K, Vogt C, Blondin D, et al. (2006) Multi-detector CT-colonography in inflammatory bowel disease: prospective analysis of CT-findings to high-resolution video colonoscopy. Eur J Radiol 58:140
Park SH, Ha HK, Kim AY, et al. (2006) Flat polyps of the colon: detection with 16-MDCT colonography—preliminary results. Am J Roentgenol 186:1611–1617
Fletcher JG, Johnson CD, Krueger WR, et al. (2002) Contrast-enhanced CT colonography in recurrent colorectal carcinoma: feasibility of simultaneous evaluation for metastatic disease, local recurrence, and metachronous neoplasia in colorectal carcinoma. Am J Roentgenol 178:283–290
Halligan S, Altman DG, Taylor SA, et al. (2005) CT colonography in the detection of colorectal polyps and cancer: systematic review, meta-analysis, and proposed minimum data set for study level reporting. Radiology 237:893–904
Chung DJ, Huh KC, Choi WJ, et al. (2005) CT Colonography using 16-MDCT in the evaluation of colorectal cancer. Am J Roentgenol 184:98–103
Antoch G, Vogt FM, Freudenberg LS, et al. (2003) Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology. JAMA 290:3199–3206
Abdel-Nabi H, Doerr RJ, Lamonica DM, et al. (1998) Staging of primary colorectal carcinomas with fluorine-18 fluorodeoxyglucose whole-body PET: correlation with histopathologic and CT findings. Radiology 206:755–760
Kantorova I, Lipska L, Belohlavek O, et al. (2003) Routine 18F-FDG PET preoperative staging of colorectal cancer: comparison with conventional staging and its impact on treatment decision making. J Nucl Med 44:1784–1788
Valk PE, Abella-Columna E, Haseman MK, et al. (1999) Whole-body PET imaging with [18F]fluorodeoxyglucose in management of recurrent colorectal cancer. Arch Surg 134:503–511
Cohade C, Osman M, Leal J, et al. (2003) Direct comparison of 18F-FDG PET and PET/CT in patients with colorectal carcinoma. J Nucl Med 44:1797–1803
Huebner RH, Park KC, Shepherd JE, et al. (2000) A meta-analysis of the literature for whole-body FDG PET detection of recurrent colorectal cancer. J Nucl Med 41:1177–1189
Rohren EM, Turkington TG, Coleman RE (2004) Clinical applications of PET in oncology. Radiology 231:305–332
Kim J-H, Czernin J, Allen-Auerbach MS, et al. (2005) Comparison between 18F-FDG PET, in-line PET/CT, and software fusion for restaging of recurrent colorectal cancer. J Nucl Med 46:587–595
Shim SS, Lee KS, Kim B-T, et al. 2005 Non-small cell lung cancer: prospective comparison of integrated FDG PET/CT and CT alone for preoperative staging. Radiology 236:1011–1019
Antoch G, Saoudi N, Kuehl H, et al. (2004) Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: comparison with CT and PET. J Clin Oncol 22:4357–4368
Veit P, Kuhle C, Beyer T, et al. (2006) Whole body positron emission tomography/computed tomography (PET/CT) tumour staging with integrated PET/CT colonography: technical feasibility and first experiences in patients with colorectal cancer. Gut 55:68–73
Antoch G, Kuehl H, Kanja J, et al. (2004) Dual-modality PET/CT scanning with negative oral contrast agent to avoid artifacts: introduction and evaluation. Radiology 230:879–885
Beyer T, Antoch G, Blodgett T, et al. (2003) Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med Mol Imaging 30:588–596
Taylor SA, Halligan S, Goh V, et al. (2003) Optimizing colonic distention for multi-detector row CT colonography: effect of hyoscine butylbromide and rectal balloon catheter. Radiology 229:99–108
Veit-Haibach P, Kuehle CA, Beyer T, et al. (2006) Diagnostic accuracy of colorectal cancer staging with whole-body PET/CT colonography. JAMA 296:2590–2600
Church J, Delaney C (2003) Randomized, controlled trial of carbon dioxide insufflation during colonoscopy. Dis Colon Rectum 46:322–326
Grant DS, Bartram CI, Heron CW (1986) A preliminary study of the possible benefits of using carbon dioxide insufflation during double-contrast barium enema. Br J Radiol 59:190–191
Yee J, Kumar NN, Hung RK, et al. (2003) Comparison of supine and prone scanning separately and in combination at CT colonography. Radiology 226:653–661
Morrin M, Farrell R, Keogan M, et al. (2002) CT colonography: colonic distention improved by dual positioning but not intravenous glucagon. Eur Radiol 12:525
Chen SC, Lu DS, Hecht JR, et al. (1999) CT colonography: value of scanning in both the supine and prone positions. AJR Am J Roentgenol 172:595–599
Hara AK, Johnson CD, MacCarty RL, et al. (2001) CT colonography: single- versus multi-detector row imaging. Radiology 219:461–465
Edwards JT, Mendelson RM, Fritschi L, et al. (2004) Colorectal neoplasia screening with CT colonography in average-risk asymptomatic subjects: community-based study. Radiology 230:459–464
Fenlon HM, Nunes DP, Schroy PC, et al. (1999) A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps. N Engl J Med 341:1496–1503
Quon A, Napel S, Beaulieu CF, et al. (2006) “Flying through” and “flying around” a PET/CT scan: Pilot study and development of 3D integrated 18F-FDG PET/CT for virtual bronchoscopy and colonoscopy. J Nucl Med 47:1081–1087
Veit P, Ruehm S, Kuehl H, et al. (2006) Lymph node staging with dual-modality PET/CT: enhancing the diagnostic accuracy in oncology. Eur J Radiol 58:383
Drenth J, Nagengast F, Oyen W. (2001) Evaluation of (pre-)malignant colonic abnormalities: endoscopic validation of FDG-PET findings. Eur J Nucl Med Mol Imaging 28:1766
Friedland S, Soetikno R, Carlisle M, et al. (2005) 18-fluorodeoxyglucose positron emission tomography has limited sensitivity for colonic adenoma and early stage colon cancer. Gastroint Endosc 61:395
Yasuda S, Fujii H, Nakahara T, et al. (2001) 18F-FDG PET detection of colonic adenomas. J Nucl Med 42:989–992
Gutman F, Alberini J-L, Wartski M, et al. (2005) Incidental colonic focal lesions detected by FDG PET/CT. Am J Roentgenol 185:495–500
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kinner, S., Antoch, G., Bockisch, A. et al. Whole-body PET/CT-colonography: a possible new concept for colorectal cancer staging. Abdom Imaging 32, 606–612 (2007). https://doi.org/10.1007/s00261-007-9202-8
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00261-007-9202-8