Abstract
Background:
Treatment of distal tibial fractures has always been a challenge. Distal tibia is more superficial, with less soft tissue coverage and blood supply. Therefore, operative treatment can lead to complications. We aim to see the results of the distal tibial fracture fixation with LCP using MIPO.
Patients and Methods:
Twenty-one consecutive patients were prospectively reviewed. AO types 43A, 43B and 43C were included. Fourteen male and seven female patients with a mean age of 51 years were included.
Results:
Mean time to union was 5.5 months (range 3–13 months). Seventeen fractures healed with good functional outcome. One patient had delayed union. One patient had nonunion and underwent revision; the fracture ultimately healed with good functional outcome. Two patients developed superficial wound infections but the fractures united completely.
Discussion:
The MIPO technique for distal tibia has shown good results with many additional advantages over the conventional methods. Early mobilization without risk of secondary displacement helps to prevent stiffness and contracture.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Fisher WD, Hambledon DL. Problems and pitfalls of compression fixation of long bone fractures: a review of results and complications. Injury 1978;10:99–107.
Olerud S, Karlstrom G. Tibial fractures treated by AO compression osteosynthesis. Acta Orthop Scand Suppl 1972;1:1–104.
Ruëdi T, Allgöwer M. Fractures of the lower end of the tibia into the ankle joint. Injury 1969;1:92–9.
Ruëdi T, Allgöwer M. The operative treatment of intraarticular fractures of the lower end of the tibia. Clin Orthop 1979;138:105–10.
Russell TA. Fractures of the tibia and fibula. In: Rockwood CA, Green DP, Buckolz RW, Heckman JD, eds. Fractures in adults, 4th edn. Philadelphia: Lippincott, 1996:2139–57.
Wagner M. General principles for the clinical use of the LCP. Injury 2003;34:B31–42.
Siebenrock KA, Schillig B, Jakob RP. Treatment of complex tibial shaft fractures. Arguments for early secondary intramedullary nailing. Clin Orthop Relat Res 1993;290:269–74.
Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study. Injury 1997;28:SA7–12.
Bhandari M, Guyatt GH, Swiontkowski MF, Schemitsch EH. Treatment of open fractures of the shaft of the tibia. J Bone Joint Surg Br 2001;83:62–8.
Egol KA, Kubiak EN, Fulkerson E, Kummer FJ, Koval KJ. Biomechanics of locked plates and screws. J Orthop Trauma 2004;18:488–93.
Hochstein P, Aymar M, Winkler H, Wentzensen A. Surgical treatment of diaphyseal tibial fractures. Choice of procedure and results of treatment of 187 fractures. Unfallchirurgie 1994;20:259–75.
Kai H, Yokoyama K, Shindo M, Itoman M. Problems of various fixation methods for open tibia fractures: experience in a Japanese level I trauma center. Am J Orthop 1998;27:631–6.
Ryf C, Götsch U, Perren T, Rillmann P. Neue Stabilisierungsverfahren bei distalen Tibiafrakturen (LCP, MIPO). Ther Umschau Band 2003;60:768–75.
Skoog A, Soderqvist A, Tornkvist H, Ponzer S. One-year outcome after tibial shaft fractures: results of a prospective fracture registry. J Orthop Trauma 2001;15:210–5.
Sommer C, Gautier E. Stellenwert und Vorteil neuer winkelstabiler Implantate bei Schaftfrakturen (LCP vs. Nagel. Ther Umschau 2003;60:751–6.
Sommer C, Gautier E, Müller M, Helfet DL, Wagner M. First clinical results of the locking compression plate (LCP). Injury 2003;34:B43–54.
Toms AD, McMurtie A, Maffulli N. Percutaneous plating of the distal tibia. J Foot Ankle Surg 2004;43:199–203.
Tornetta P III, Weiner L, Bergman M, Watnik N, Steuer J, Kelly M, Yang E. Pilon fractures: treatment with combined internal and external fixation. J Orthop Trauma 1993;7:489–96.
Borg T, Larsson S, Lindsjo U. Percutaneous plating of distal tibia fractures: preliminary results in 21 patients. Injury 2004;35:608–14.
Collinge CA, Sanders RW. Percutaneous plating in the lower extremity. J Am Acad Orthop Surg 2000;8:211–6.
Khoury A, Liebergall M, London E, Mosheiff R. Percutaneous plating of distal tibial fractures. Foot Ankle Int 2002;23:818–24.
Frigg R. Development of the locking compression plate. Injury 2003;34:B6–10.
Muller ME, Nazarian S, Koch P, Schatzker J. The AO classification of fractures of long bones. Berlin: Springer, 1990.
Gustilo B, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones. J Bone Joint Surg 1976;58-A:453–8.
Borrelli J, Prickett W, Song E, Becker D, Ricci W. Extraosseous blood supply of the tibia and the effects of different plating techniques: a human cadaveric study. J Orthop Trauma 2002;16:691–5.
Krettek C, Schandelmaier P, Miclau T, Tscherne H. Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. Injury 1997;28:SA20–30.
Krettek C, Schandelmaier P, Miclau T, Bertram R, Holmes W, Tscherne H. Transarticular joint reconstruction and indirect plate osteosynthesis for complex distal supracondylar femoral fractures. Injury 1997;28:SA31–41.
McFerran MA, Smith SW, Boulas HJ, Schwartz HS. Complications encountered in the treatment of pilon fractures. J Orthop Trauma 1992;6:273–85.
Wenda K, Runkel M, Degreif J, Rudig L. Minimally invasive plate fixation in femoral shaft fractures. Injury 1997;28:SA13–9.
Redfern DJ, Syed SU, Davies SJM. Fractures of the distal tibia. Injury 2004;35:615–20.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mushtaq, A., Shahid, R., Asif, M. et al. Distal Tibial Fracture Fixation with Locking Compression Plate (LCP) Using the Minimally Invasive Percutaneous Osteosynthesis (MIPO) Technique. Eur J Trauma Emerg Surg 35, 159–164 (2009). https://doi.org/10.1007/s00068-008-8049-1
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00068-008-8049-1