Abstract
Purpose
About 1% to 3% of laryngoscopic intubations can be difficult or impossible. Light-guided intubation has been proven to be an effective, safe, and simple technique. This article reviews current knowledge about the newer version lightwand: the Trachlight™ (TL).
Source
To determine its clinical utility and limitations, we reviewed the current literature (book and journal articles) on the TL since its introduction in 1995.
Principal findings
TL has been shown to be useful both in oral and nasal intubation for patients with difficult airways. It may also be useful in “emergency” situations or when direct laryngoscopy or fiberoptic endoscopy is not effective, such as with patients who have copious secretions or blood in the oropharynx. TL can also be used for tracheal intubation in conjunction with other devices (laryngeal mask airway -LMA-, intubating LMA, direct laryngoscopy). However, TL should be avoided in patients with tumours, infections, trauma or foreign bodies in the upper airway.
Conclusions
Based on the clinical reports available, the TL has proven to be a useful option for tracheal intubation. In addition, the device can also be used together with other intubating devices, such as the intubating LMA and the laryngoscope, to improve intubating success rates. A clear understanding of the principle of transillumination of the TL, and an appreciation of its indications, contraindications, and limitations, will improve the effectiveness of the device as well as reducing the likelihood of complications. Finally, regular practice with the TL with routine surgical patients requiring tracheal intubation will further improve intubation success rates.
Résumé
Objectif
La fréquence d’intubation difficile ou impossible varie de 1% à 3%. L’intubation trachéale avec le Trachlight™ (TL) représente une technique efficace, sûre et simple.
Dans cet article nous voulons réviser les connaissances actuelles sur le stylet lumineux TL.
Méthode
Pour déterminer les applications et les limitations du TL, nous avons révisé la littérature (livres ou revues) sur le TL à partir de son introduction en 1995.
Resultats
Le TL permet une intubation oro-ou naso-trachéale dans différentes situations d’intubation difficile. Cette technique d’intubation avec le TL peut également être utile dans des situations d’urgence ou quand l’intubation trachéale avec le bronchoscope n’est pas indiquée, comme chez les patients qui présentent des sécrétions abondantes ou du sang dans l’oropharynx.
Le TL peut également être utilisé pour l’intubation trachéale en même temps que d’autres dispositifs (masque laryngé, masque laryngé pour intubation, laryngoscopie directe). Cependant l’usage du TL devrait être évité chez les patients présentant une tumeur, une infection, un traumatisme ou un corps étranger dans les voies aériennes.
Conclusion
Selon les rapports cliniques à notre disposition, nous pouvons affirmer que le TL représente une solution de remplacement utile à la laryngoscopie traditionnelle. Le TL peut également être utilisé avec d’autre dispositifs comme le masque laryngé et la laryngoscopie directe pour augmenter le taux de réussite de l’intubation trachéale.
En conclusion, la pratique régulière avec le TL et une connaissance de ses indications, contre-indications et limitations, peut améliorer l’efficacité du dispositif et réduire la probabilité de complications.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Hung OR, Stewart RD. Illuminating stylet (lightwand).In: Benumof JL (Ed.). Airway Management, Mosby, 1996: 342–52.
Hung OR, Stewart RD. Lightwand intubation: I — A new ligthwand device. Can J Anaesth 1995; 42: 820–5.
Hung OR, Pytka S, Morris I, Murphy M, Stewart RD. Lightwand intubation: II — Clinical trial of a new ligthwand for tracheal intubation in patients with difficult airways. Can J Anaesth 1995; 42: 826–30.
Hung OR, Pytka S, Morris, I et al. Clinical trial of a new lightwand device (Trachlight) to intubate the trachea. Anesthesiology 1995; 83: 509–14.
Hung OR, Al-Qatari M Light-guided retrograde intubation. Can J Anaesth 1997; 44: 877–82.
Nishiyama T, Matsukawa T, Hanaoka K. Safety of a new lightwand device (Trachlight™): temperature and histopathological study. Anesth Analg 1998; 87: 717–8.
Fisher QA, Tunkel DE. Lightwand intubation of infants and children. J Clin Anesth 1997; 9: 275–9.
Ovassapian A, Meyer RM. Airway management.In. Longnecker JH, Tinker JH, Morgan GE, (Eds.). Principles and Practice of Anesthesiology 2nd ed. Mosby, 1998: 1064–99.
Iseki K, Murakawa M, Tase C, Otsuki M. Use of a modified lightwand for nasal intubation (Letter). Anesthesiology 1999; 90: 635.
Asai F. Endotrol tube for blind nasotracheal intubation (Letter). Anaesthesia 1996; 50: 507.
Agrò F, Brimacombe J, Marchionni L, Carassiti M, Cataldo R. Nasal intubation with the Trachlight (Letter). Can J Anesth 1999; 46: 907–8.
Mallampati SR, Gatt SP, Gugino LD, et al. A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J 1985; 32: 429–4.
Iseki K, Watanabe K, Iwama H. Use of the Trachlight for intubation in the Pierre-Robin syndrome (Letter). Anaesthesia 1997; 52: 801–2.
Agrb F, Brimacombe J, Carassiti M, Morelli A, Giampalmo M, Cataldo R. Use of a lighted stylet for intubation via the laryngeal mask airway. Can J Anaesth 1998; 45: 556–60.
Asai T, Latto IP. Use of the lighted stylet for tracheal intubation via the laryngeal mask airway (Letter). Br J Anaesth 1995; 75: 503–4.
Asai T, Oldham T, Latto IP. Unexpected difficulty in the lighted stylet-aided tracheal intubation via the laryngeal mask (Letter). Br J Anaesth 1997; 78: 111–2.
Agrò F, Brimacombe J, Carasiti M, Morelli A, Giampalmo M, Cataldo R. Lighted stylet as an aid to blind tracheal intubation via the LMA (Letter). J Clin Anesth 1998; 10: 263–4.
Hung OR. Light-guided tracheal intubation using a new intubating LMA (Fastrach). Anesthesiology 1998; 89: A553(abstract).
Biehl JW, Bourke DL. Use of the lighted stylet to aid direct laryngoscopy (Letter). Anesthesiology 1997; 86: 1012.
Gataure PS, Vaughan RS, Latto IP. Simulated difficult intubation. Comparison of the gum elastic bougie and the stylet. Anaesthesia 1996; 51: 935–8.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Agrò, F., Hung, O.R., Cataldo, R. et al. Lightwand intubation using the Trachlight™: a brief review of current knowledge. Can J Anesth 48, 592–599 (2001). https://doi.org/10.1007/BF03016838
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF03016838