A new technique was applied to improve safety for large-bore biopsies of subpleural pulmonary lesion. In 27 patients, normal saline solution (20–40 ml) was injected extrapleurally under CT-guidance in the access route to subpleurally situated lung lesions. Thickness of ventilated lung interposed between the target and the parietal pleura was up to 8 mm (mean: 4,1 mm). The injected fluid resulted in an extrapleural bulge that abutted the lesion to be biopsied. Biopsy with the 14-gauge Trucut needle did not result in pneumothorax in all cases. There were no complications associated with this technique. Extrapleural injection of saline may provide a safe access route to selected pulmonary lesions for CT-guided large-bore transthoracic biopsies.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Sinner WN (1979) Complications of percutaneous transthoracic needle aspiration biopsy. Acta Radiol (Diagn) 17:813–828
Günther RW (1992) Percutaneous interventions in the thorax: Seventh annual Charles Dotter memorial lecture. J Vasc Interv Radiol 3:379–390
Fink I, Gamsu G, Marter LP (1982) CT-guided aspiration biopsy of the thorax. J Comput Assist Tomogr 6:958–962
Marter LP, Moss NA, Goldberg HI, Gross BH (1982) CT-guided fine-needle aspirations for diagnosis of benign and malignant disease. AJR 140:363–367
Gatenby RA, Mulhern CG, Broder GJ, Moldofsky PJ (1984) Computed tomographic-guided biopsy of small apical and peripheral upper lobe lung masses. Radiology 150:591–592
Sider L, Davis TM Jr (1987) Hilar masses: Evaluation of CT-guided biopsy after negative bronchoscopic examination. Radiology 164:107–109
Boe J, Johansson S (1987) Fine-needle and screw-needle sample of CT-assisted biopsies of chest lesions. Eur J Respir Dis 71:108–112
vanSonnenberg E, Casola G, Ho M, Neff CC, Varney RR, Wittich GR, Christensen R, Friedman PJ (1988) Difficult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 167:457–461
Skupin A, Gomez F, Husain M, Skupin C, Bigman O (1987) Complications of transthoracic needle biopsy decreased with Isobutyl 2-Cyano-acrylate: A pilot study. Ann Thorac Surg 43:406–408
Petsas T, Fezoulidis I, Siamplis D, Dimopoulos, I (1990) Die Verwendung von homologen, geronnenem Blut zur Pneumothoraxprophylaxe nach perkutaner Lungenbiopsie (experimentelle Studies). ROEFO 152:565–568
McCartey R, Tait D, Stilson M, Seidel GF (1974) A technique for the prevention of pneumothorax in pulmonary aspiration biopsy. AJR 120:872–875
Poe RH, Kallay MC, Wicks CM, Odoroff CL (1984) Predicting risk of pneumothorax in needle biopsy of the lung. Chest 85:232–234
Bourguin PM, Shepard JAO, Mcloud TC, Spizarny DL, Derick CG (1988) Transthoracic needle aspiration biopsy: Evaluation of the blood patch technique. Radiology 166:93–95
Klose KC, Günther RW (1988) CT-gesteuerte, Punktionen. In: Günther RW, Thelen M (eds). Interventionelle Radiologie. Thieme, Stuttgart, pp. 459–484.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Klose, KC. CT-Guided large-bore biopsy: Extrapleural injection of saline for safe transpleural access to pulmonary lesions. Cardiovasc Intervent Radiol 16, 259–261 (1993). https://doi.org/10.1007/BF02602975
Issue Date:
DOI: https://doi.org/10.1007/BF02602975