Abstract
In order to study the biomechanical properties of the arterial wall and to compare arteries with different histologic structures, we designed a device that allows testing of arterial segments under near-physiologic conditions. A hydrodynamic generator simulates systolo-diastolic pressures in an open loop. An intraarterial pressure sensor and a sonomicrometer connected to two piezoelectric crystals placed in diametric opposition on the arterial wall allow computer calculation of compliance, stiffness, midwall radial arterial stress, Young modulus, and incremental modulus for a given arterial segment at a given pressure setting. Seven healthy common carotid artery (CCA) segments and seven healthy (superficial) femoral artery (FA) segments were studied immediately after removal from brain-dead donors between the ages of 18 and 35 years. Histologic examination was performed to determine the density of elastic fibers in the arterial wall. Hysteresis was observed in all segments regardless of pressure settings. Compliance was greater and modulus values and stiffness were lower in CCA than in FA. No evidence of structural change was noted after testing in the circulation loop. These preliminary results open the way to a wide variety of applications for our hydrodynamic circulation loop. Experiments will be undertaken to compare the mechanical properties of arteries before and after cryopreservation.
Résumé
Dans le but d'étudier les propriétés mécaniques de la paroi artérielle et de pouvoir établir des comparaisons entre des segments artériels de structure histologique différente, nous avons mis au point un banc d'essai hydrodynamique permettant de tester des segments artériels dans des conditions voisines de la réalité physiologique. Un générateur hydrodynamique permettait d'obtenir dans un circuit ouvert un régime de pressions de type systolo-diastolique. Un capteur de pression intra-artériel, ainsi qu'un sonomicromètre relié à des cristaux piézo-électriques placés de façon diamétralement opposée sur la paroi artérielle, permettaient de calculer, pour un régime de pressions donné et grâce à l'acquisition de données dans un système informatique, la compliance, la rigidité, la contrainte trans-pariétale, le module de Young, le module incrémentiel d'un segment artériel. Nous avons étudié sept artères carotides communes (CC), et sept artères fémorales (superficielles) (F) fraîchement prélevées chez des sujets sains âgés de 18 à 35 ans. Des corrélations avec la richesse en fibres élastiques de la paroi artérielle ont été établies. Nous avons mis en évidence un phénomène d'hystérésis pour chaque artère testée quel que soit le niveau de pression considéré. La compliance des artères CC a été plus importante, les modules et la rigidité ont été moins importants et ce de façon significative par rapport aux artères F. Aucune altération histologique n'a été mise en évidence après passage des segments artériels au banc d'essai. Ces résultas préliminaires nous permettent d'envisager de nombreuses applications à ce travail dont l'une d'entre elles sera la mesure comparative des propriétés mécaniques des artères avant et après cryopréservation.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Abebe W, Cavallari N, Agrawal DK, Rowley J, Thorpe PE, Hunter WJ, Edwards JD (1993) Functional and morphological assessment of rat aorta stored in University of Wisconsin and Eurocollins solutions. Transplantation 56: 808–816
Bergel DH (1961) The static elastic properties of the arterial wall. J Physiol 156: 445–457
Charpiot P, Rolland PH, Friggi A, Piquet P, Scalbert E, Bodard H, Barlatier A, Latrille V, Tranier P, Mercier C, Luccioni R, Calaf R, Garçon D (1993) Angiotensin converting enzyme inhibition with periindopril and atherogenesis induced structural and functional changes in mini-pig arteries. Arterioscler Thromb 13: 1125–1138
Cox RH (1975) Anisotropic properties of canine carotid artery in vitro. J Biomechanics 8: 293–300
Dobrin PB (1978) Mechanical Properties of Arteries. Physiol Rev 58: 397–460
Dobrin PB (1990) Physiopathologie et pathogénie des anévrysmes de l'aorte abdominale. In: Kieffer E (ed) Les anévrysmes de l'aorte abdominale sous-rénale. AERCV, Paris, pp 9–21
Friggi A, Bodard H, Berenger FP, Esclapez F, Rolland PH (1989) Effects of sin-1 on peripheral hemodynamics and viscoelastic properties of aorta in anesthetized rabbits. Cardiovasc Drugs Ther 3: 445–458
Gow BS (1970) Viscoelastic properties of conduit arteries. Circ Res 26 [Suppl II]: 113–122
Issartier P, Siouffi M, Pelissier R (1978) Simulation of blood flow by a hydrodynamic generator. Med Prog Technol 6: 39–40
Kieffer E., Bahnini A, Koskas F, Ruotolo C, Le Blevec D, Plissonnier D (1993). In situ allograft replacement of infected infrarenal aortic prosthetic grafts: results in forty-three patients. J Vasc Surg 17: 349–356
Kirklin JK, Smith D, Novick W, Naftel DC, Kirlin JW, Pacifico AD, Nanda NC, Helmcke FR, Bourge RC (1993) Long-term function of cryopreseved aortic homografts. J Thorac Cardiovasc Surg 106: 154–166
Learoyd BM, Taylor MG (1965) Alterations with age in the viscoelastic properties of human arterial walls. Circ Res 16: 278–292
Maillet M (1989) Histologie des artères de moyen et grand calibre. In: Rouffy J, Natali J (eds) Artériopathies périphériques non athéromateuses. Masson, Paris, pp 36–55
Nichols WW, O'Rourke MF (1990) Properties of the arterial wall. In: Mc Donald's (ed) Blood flow in arteries. Arnold, London, pp 77–124
Pagani M, Mirsky I, Baig H, Manders WT, Kerkhof P, Vatner SF (1979) Effects of age on aortic pressure. Diameter and elastic stiffness. Stress relationships in unanesthetized sheep. Circ Res 44: 420–429
Pelissier R, Cassot F, Farahifar D, Bialonski W, Issartier P, Bodard H, Friggi A (1983) Simulateur cardiovasculaire. ITBM 4: 33–45
Remington JW (1955) Hysteresis loop behavior of the aorta and other extensible tissues. Am J Physiol 180: 83–95
Rieu R, Friggi A, Farahifar D, Cassot F (1987) Determination in vitro de la relation pression-diamètre et des profils de vitesse par des techniques ultrasonores. Application in vivo. J Physiol (Paris) 82: 175–182
Sauer G, Tebbe U, Krause H (1981) Die Wirkung von Molsidomin auf den arteriellen “Windkessel”. Z Kardiol 70: 713–718
Sonesson B, Hansen F, Stale H, Lanne T (1993) Compliance and Diameter in the human abdominal aorta. The influence of age and sex. Eur J Vasc Surg 7: 690–697
Tedgui A, Lévy B (1994) Biologie de la paroi artérielle. Masson, Paris
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Rosset, E., Brunet, C., Rieu, R. et al. Viscoelastic properties of human arteries methodology and preliminary results. Surg Radiol Anat 18, 89–96 (1996). https://doi.org/10.1007/BF01795225
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01795225