Summary
In a prospective study 24 patients with a displaced fracture of the radial head were treated by open reduction and internal fixation using absorbable polygly-colide pins, 2 mm in diameter. All patients admitted with fractures involving a quarter or more of the radial head, whether comminuted or not, were included in the study whenever there was a displacement of 2 mm or more between the fragments. The mean follow-up time was 28 months (range 15–43 months). A postoperative redisplacement of 1–3 mm between the fragments was seen in four patients with severely comminuted fractures. A transient inflammatory reaction around the implants occurred in two cases 8–12 weeks postoperatively. The functional end-result was classified as excellent or good in 22 patients (91%). This study indicated that successful fixation of displaced fractures of the radial head can be accomplished by using absorbable pins.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Böstman O, Vainionpää S, Hirvensalo E, Mäkelä A, Vihtonen K, Törmälä P, Rokkanen P (1987) Biodegradable internal fixation for malleolar fractures. A prospective randomised trial. J Bone Joint Surg [Br] 69:615–619
Böstman O, Hirvensalo E, Vainionpää S, Mäkelä A, Vihtonen K, Törmälä P, Rokkanen P (1989) Ankle fractures treated using biodegradable internal fixation. Clin Orthop 238:195–203
Böstman O, Hirvensalo E, Mäkinen J, Rokkanen P (in press) Foreign-body reactions to fracture fixation implants made of biodegradable synthetic polymers. J Bone Joint Surg [Br]
Broberg MA, Morrey BF (1986) Results of delayed excision of the radial head after fracture. J Bone Joint Surg [Am] 68:669–674
Bunker TD, Newman JH (1985) The Herbert differential pitch bone screw in displaced radial head fractures. Injury 16:621–624
Claes L, Burri C, Kiefer H, Mutschler W (1986) Resorbierbare Implantate zur Refixierung von osteochondralen Fragmenten in Gelenkflächen. Aktuel Traumatol 16:74–77
Coleman DA, Blair WF, Shurr D (1987) Resection of the radial head for fracture of the radial head. J Bone Joint Surg [Am] 69:385–392
Gammelgaard N, Jensen J (1983) Wound complications after closure of abdominal incisions with Dexon and Vicryl. A randomized double-blind study. Acta Chir Scand 149:505–508
Goldberg I, Peylan J, Yosipovitch Z (1986) Late results of excision of the radial head for an isolated closed fracture. J Bone Joint Surg [Am] 68:675–679
Hirvensalo E (1989) Fracture fixation with biodegradable rods. Forty-one cases of severe ankle fractures. Acta Orthop Scand 60:601–606
Hoffmann R, Krettek C, Haas N, Tcherne H (1989) Die distale Radiusfraktur. Frakturstabilisierung mit biodegradablen Osteosynthese-Stiften (Biofix®). Unfallchirurg 92:430–434
Leixnering M, Moser KL, Poigenfürst J (1989) Die Verwendung von Biofix C zur Stabilisierung von Innenknöchelfrakturen. Aktuel Traumatol 19:113–115
Martinelli B (1985) Silicone-implant replacement arthroplasty in fractures of the radial head. A follow-up report. Bull Hosp Jt Dis Orthop Inst 2:158–161
Mason ML (1954) Some observations on fracture of the head of the radius. Br J Surg 42:123–132
McArthur RA (1987) Herbert screw fixation of fracture of the head of the radius. Clin Orthop 224:79–87
Menger MD, Gauger JU, Schmitt-Köppler A (1988) Die chirurgische Versorgung von dislozierten Frakturen des proximalen Radiusendes. Unfallchirurg 91:77–84
Mikić Z, Vukadinović M (1983) Late results in fractures of the radial head treated by excision. Clin Orthop 181:220–228
Miller GK, Drennan DB, Maylahn DJ (1981) Treatment of displaced segmental radial-head fractures. J Bone Joint Surg [Am] 63:712–717
Morrey BF, Chao EY, Hui FC (1979) Biomechanical study of the elbow following excision of the radial head. J Bone Joint Surg [Am] 61:63–68
Morrey BF, An KN, Stormont TJ (1988) Force transmission through the radial head. J Bone Joint Surg [Am] 70:250–256
Rokkanen P, Böstman O, Vainionpää S, Vihtonen K, Törmälä P, Laiho J, Kilpikari J, Tamminmäki P (1985) Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle. Lancet 1:1422–1424
Sanders RA, French HG (1986) Open reduction and internal fixation of comminuted radial head fractures. Am J Sports Med 14:130–135
Schatzker J (1987) Fractures of the radial head. In: Schatzker J, Tile M (eds) The rationale of operative fracture care. Springer, Berlin Heidelberg New York, pp 97–101
Schmitt E, Heisel J, Wüst H-L (1988) Indikation und Ergebnisse der primären und sekundären Radiusköpfchenresektion. Unfallchirurg 91:243–251
Shmueli G, Herold HZ (1981) Compression screwing of displaced fractures of the head of the radius. J Bone Joint Surg [Br] 63:535–538
Tillmann B, Bartz B, Schleicher A (1988) Biomechanische Untersuchungen am menschlichen Ellenbogengelenk. Unfallchirurg 91:57–63
Vainionää S, Vihtonen K, Mero M, Pätiälä H, Rokkanen P, Kilpikari J, Törmälä P (1986) Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material. Arch Orthop Trauma Surg 106:1–4
Vasenius J, Vainionpää S, Vihtonen K, Mero M, Mikkola J, Rokkanen P, Törmälä P (1989) Biodegradable self-reinforced polyglycolide (SR-PGA) composite rods coated with slowly biodegradable polymers for fracture fixation. Strength and strength retention in vitro and in vivo. Clin Materials 4:307–317
Vihtonen K (1988) Fixation of rabbit osteotomies with biodegradable polyglycolic acid thread. Acta Orthop Scand 59:279–283
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hirvensalo, E., Böstman, O. & Rokkanen, P. Absorbable polyglycolide pins in fixation of displaced fractures of the radial head. Arch Orthop Trauma Surg 109, 258–261 (1990). https://doi.org/10.1007/BF00419939
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00419939