Abstract
Background
Prevention of redisplacement is an issue after the treatment of fractures of the distal third of the radius in children. In this study, we used a locked wires fixator for this type of fracture and achieved favorable treatment outcomes.
Methods
The subjects were 8 children with fractures of the distal third of the radius (male: 7, female: 1, mean age: 9.0 years old) who underwent surgery with locked wires fixators and were able to be evaluated 12 months after surgery. Immobilization was not applied after surgery. The locked wires fixator or K-wire was removed when the bridging callus was observed on plain radiography 4–6 (mean 5.5) weeks after surgery in all patients. The presence of bone union, functional outcomes, and complications were investigated postoperatively.
Results
All patients achieved bone union without redisplacement excellent function. The pin site infection was observed in two patients.
Conclusions
The locked wires fixator may be a new useful treatment method for fractures likely to cause postoperative redisplacement.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
Fractures of the distal third of the radius are one of the most common fractures of the upper limb of children [1]. In general, bone union can be acquired by manual reduction and casting, and favorable functional recovery is expected [2]. The incidence of redisplacement after reduction which was associated with the position of forearm in the cast or loss of cast fixation is approximately 34% [3, 4], and prevention of redisplacement after treatment remains an issue. Based on this background, plate fixation was recommended for this type of fracture [5], but it is not the standard treatment because of its high invasiveness.
Percutaneous pinning for fractures of the distal third of the radius in children can obtain higher stability than cast immobilization alone [6]. However, percutaneous pinning is complicated and unlikely to result in stable fixation because the pin insertion angle is small and the lever arm length of the inserted pin shortens [7]. Thus, we used a locked wires fixator, which exhibits stronger fixation than percutaneous pinning, for this fracture and achieved favorable treatment outcomes.
Methods
This study was approved by the ethics committee for medical research of our university (No. 19-084), and informed consent was received from the parents of all patients.
The subjects were 8 children with fractures of the distal third of the radius [male: 7, female: 1, mean age: 9.0 (range: 5–13) years old] who underwent surgery at our hospital between September 2017 and October 2018 and were able to be evaluated 12 months after surgery. Surgery was performed within 4 days (1–4 days) after injury on all patients under general anesthesia. Manual reduction was first tried and when it was not possible, reduction was applied using the intrafocal pin technique with Kirschner wire (K-wire) in the fracture region. Then, intramedullary nail fixation with K-wire was applied retrogradely from the distal bone fragment. A burr hole was prepared in the radial dorsal bone cortex proximal to the epiphyseal line of the distal bone fragment using 1.6-mm K-wire, and it was inserted into the medullary cavity of the proximal bone fragment through this burr hole as an intramedullary nail, followed by insertion of a threaded mini fixator pin (ARATA Co., Ltd., Tokyo, Japan) into the proximal bone fragment. Lastly, the K-wire and mini fixator pin were connected and fixed using the locked wires fixator “JuNction” (ARATA Co., Ltd., Tokyo, Japan) (Video 1). No immobilization was applied after surgery, and the locked wires fixator was removed when the bridging callus formed.
Data collection included the presence of concomitant distal ulna fracture at the time of injury, bone union 12 months after surgery, wrist range of motion, grasp (% of the healthy side), visual analog scale (VAS), quick disabilities of the arm, shoulder and hand (Q-DASH) score, modified mayo wrist (Mayo) score, and complications.
Results
Concomitant distal ulna fracture occurred at the time of injury in all patients. Surgical treatment using the locked wires fixator was applied only to the radius. Intramedullary nail fixation with K-wire was applied to the olecranon over the ulna in 1 of the 8 patients, and the ulna was not treated in the other 7 patients. The locked wires fixator or K-wire was removed when the bridging callus was observed on plain radiography 4–6 (mean 5.5) weeks after surgery in all patients. The pin insertion site became infected in two of the 8 patients, but it was resolved by removal of the pin and oral antibiotic treatment. At 12 months after surgery, bone union of the radius/ulna was noted without redisplacement of the fracture region in all patients. The wrist range of motion was 88.8° ± 2.3° on flexion and 88.8° ± 2.3° on extension, forearm pronation was 88.1° ± 2.6°, forearm supination was 89.4° ± 4.2°, and the grip strength relative to that on the healthy side was 89.3 ± 5.9%. The VAS, Q-DASH score, and Mayo score were 0/10, 0/100, and 100/100, respectively (Table 1).
Case presentation
A 13-year-old boy fell and was injured while playing soccer, and visited our hospital for swelling, deformation, and pain of the right wrist joint over the forearm. On plain radiography, fractures of the distal third of both the radius and ulna were noted (Fig. 1a, b). Using the procedure introduced in Materials and Methods, only the radius was fixed using the locked wires fixator (Fig. 2a–d). Postoperative immobilization was not necessary, and movement of the wrist joint and forearm was permitted according to pain. No postoperative complications developed, bone union was acquired on the final follow-up, and the patient returned to playing soccer without issue (Fig. 3a, b).
Discussion
The acceptable range of reduction of distal forearm fractures in children depends on age. A displacement angle of 20° or smaller is acceptable in 10-year-old or younger patients, but the target of reduction should be a 10° or smaller displacement angle in those 10 years old or older because the self-correction ability of bone decreases [7]. Redisplacement of the fracture region readily occurs even if it was previously reduced in children with fractures of the distal third of the radius [3, 7]. An entirely displaced fracture suggesting periosteal injury and 11° or larger displacement of the coronal plane are known risks for redisplacement [8, 9]. Khosla et al. epidemiologically surveyed the incidence of distal forearm fracture and found the highest incidence of this fracture in 10–14 years old of both sexes, which was approximately 800–1300 in 100,000 persons in males and 500–800 in 100,000 persons in females [1]. Therefore, this fracture commonly occurs at 10 years old or older when the self-correction ability of bone decreases, suggesting that this trauma requires stronger fixation.
Pector et al. [3] identified a factor which increases the chance of redisplacement and the failure to achieve a perfect reduction, the presence of initial complete displacement. A perfect anatomical reduction was the most important favorable prognostic factor [10]. This is because completely displaced fractures are usually associated with severe injury to the periosteum and the surrounding soft tissues [6]. The lack of a periosteal hinge affects stability and increases the incidence of redisplacement [6]. Severe soft issue injury causes more initial swelling which usually subsides in about a week resulting in a loose cast and increasing the chance of redisplacement [6]. Surgical treatment is recommended for these high-risk cases of redisplacement.
There are several surgical procedures for this fracture in children such as percutaneous pinning, intramedullary nailing, and plate fixation. Percutaneous pinning is low cost and minimally invasive, but it is complicated and unlikely to result in stable fixation because the pin insertion angle against the fracture line is small and the lever arm length of the inserted pin shortens [7]. Intramedullary nailing overcomes the disadvantage of percutaneous pinning, i.e., weak fixation, to some extent, but postoperative immobilization is necessary and initiation of joint movement is delayed [7]. However, these fixation techniques can obtain not high stability. Single-bone intramedullary nailing of unstable both-bone forearm fractures in children leads to increased redisplacement (redisplacement rate is approximately 31%) [11]. On the other hand, reliable fixation can be acquired by plate fixation and it has almost no risk of redisplacement [5]. However, there are risks of deep infection and refracture after removal the plate with this method, and these complications actually occurred in 2 case of all 43 cases (deep infection: 1, refracture: 1) [5]. Realistically, many surgeons want to avoid the invasiveness of plate placement and skin incision in the forearm in children for esthetic and emotional reasons.
Surgical treatment with the locked wires fixator can reduce the risk of postoperative redisplacement, which is a disadvantage of conventional percutaneous pinning and intramedullary nail fixation, while retaining the advantage of plate fixation, i.e., no postoperative external fixation. The entire procedure can be applied percutaneously, being a minimally invasive treatment method. A biomechanical study on the fixing force of intramedullary rods suggested that rotational stability is improved by the insertion of several intramedullary rods [12]. It is also well known that external fixation can provide much higher stability at the fracture site than K-wire fixation [13]. In external fixation, the connection between the external fixation device and its screws or wires is outside the body. Therefore, because the lever arms are much longer than the internal fixation devices, a large moment of force is generated around them [14]. According to these biomechanical studies, our technique which is not only intramedullary pinning using two K-wires but also external fixation using locked wires fixator can connect and fix wires can obtain much higher stability compared to other techniques except plates.
Miyamoto et al. used the locked wires fixator HK2 (AREX™, Palaoseaus, France) for 5th carpometacarpal joint dislocation fractures and achieved favorable outcomes without postoperative immobilization [15]. Several studies reported that application of a locked wires fixator to fractures previously treated by percutaneous pinning enabled range of motion training early after surgery without postoperative immobilization, leading to a favorable treatment outcome [16, 17]. This technique was initially applied to fractures of the distal third of the radius in children in our study. Surgical treatment of this fracture using the locked wires fixator is minimally invasive and provides strong fixation sufficient to permit range of motion training early after surgery. All 8 patients acquired favorable final outcomes without postoperative redisplacement, suggesting that this surgical procedure overcomes the problem of postoperative redisplacement, which may develop at a high rate. Locked wire fixator system can be available worldwide. For example, the JuNction (ARATA Co., Ltd., Tokyo, Japan) used in this study was developed by Japan; Meta-HUS® and HK2® (AREX™, Palaoseaus, France) were developed by France, previously described as locked wire fixator system [15,16,17].
One of the limitations of this study is the small number of patients. In our institution, patients who need surgical treatment are referred from our satellite hospitals. Many of these fractures undergo conservative treatment at these satellite hospitals, resulting in a small number of cases due to selection bias. Next, about cost, one JuNction to connect wires is about 2000 yen. Although the cost is higher than percutaneous pinning, the cost is low for external fixator.
References
Khosla S, Melton LJ 3rd, Dekutoski MB, Achenbach SJ, Oberg AL, Riggs BL (2003) Incidence of childhood distal forearm fractures over 30 years: a population-based study. JAMA 290:1479–1485
McLauchlan GJ, Cowan B, Annan IH, Robb JE (2002) Management of completely displaced metaphyseal fractures of the distal radius in children. A prospective, randomized controlled trial. J Bone Joint Surg Br 84:413–417
Proctor MT, Moore DJ, Paterson JM (1993) Redisplacement after manipulation of distal radial fractures in children. J Bone Joint Surg Br 75:453–454
Voto SJ, Weiner DS, Leighley BL (1990) Redisplacement after closed reduction of forearm fractures in children. J Pediatr Orthop 10:79–84
Neilsen AB, Simonsen O (1984) Displaced forearm fractures in children treated with AO plates. Injury 15:393–396
Zamzam MM, Khoshhal KI (2005) Displaced fracture of the distal radius in children. J Bone Joint Surg Br 87:841–843
Bae DS (2008) Pediatric distal radius and forearm fractures. J Hand Surg Am 33:1911–1923
Alemdaroglu KB, Iltar S, Cimen O, Uysal M, Alagöz E, Atlihan D (2008) Risk factors in redisplacement of distal radial fractures in children. J Bone Joint Surg Am 90:1224–1230
Sankar WN, Beck NA, Brewer JM, Baldwin KD, Pretell JA (2011) Isolated distal radial metaphyseal fractures with an intact ulna: risk factors for loss of reduction. J Child Orthop 5:459–464
Haddad FS, Williams RL (1995) Forearm fractures in children: avoiding redisplacement. Injury 26:691–692
Colaris J, Reijman M, Allema JH et al (2013) Single-bone intramedullary fixation of unstable both-bone diaphyseal forearm fractures in children leads to increased re-displacement: a multicenter randomized controlled trial. Arch Orthop Trauma Surg 133:1079–1087
Hiatt SV, Begonia MT, Thiagarajan G, Hutchison RL (2015) Biomechanical comparison of 2 methods of intramedullary K-wire fixation of transverse metacarpal shaft fractures. J Hand Surg Am 40:1586–1590
Margic K (2006) External fixation of closed metacarpal and phalangeal fractures of digits. A prospective study of one hundred consecutive patients. J Hand Surg Am 31:30–40
Arai T, Yamamoto M, Iwatsuki K et al (2013) Mechanical advantages of a truss-structure-based fracture fixation system—a novel fracture fixation device “PINFIX”-. Nagoya J Med Sci 75:181–192
Miyamoto H, Adi M, Taleb C et al (2015) Fifth carpometacarpal fracture dislocations fixed with Meta-HUS: a series of 31 cases. Eur J Orthop Surg Traumatol 25:477–482
Adi M, Miyamoto H, Taleb C et al (2014) Percutaneous fixation of first metacarpal base fractures using locked K-wires: a series of 14 cases. Tech Hand Up Extrem Surg 18:77–81
Zemirline A, Vaiss L, Lebailly F, Gouzou S, Liverneaux PA, Facca S (2014) The MetaHUS fixation system versus pinning and plating in 5th metacarpal neck fractures. Chir Main 33:207–210
Funding
None.
Author information
Authors and Affiliations
Contributions
KN (first and corresponding author) mainly wrote this manuscript and performed medical examinations and surgery for these patients. SK, NN, YS, HO, KG, and AK were assistant of operative procedure. NN, YS, HO, and KK discussed and advised about the treatment for these patients. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflicts of interest.
Ethical approval
This study was approved by the ethics committee for medical research of our university (No. 19-084), and informed consent was received from the parents of all patients.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Electronic supplementary material
Below is the link to the electronic supplementary material.
Video 1: Surgical technique. Surgery was performed under general anesthesia and manual reduction was first tried. When it was difficult, reduction was applied employing the intrafocal pin technique using Kirschner wire (K-wire). Then, intramedullary nail fixation with K-wire was applied retrogradely from the distal bone fragment. A burr hole was prepared in the radial dorsal bone cortex using 1.6-mm K-wire at a site proximal to the epiphyseal line of the distal bone fragment, and the K-wire was then inserted into the medullary cavity of the proximal bone fragment through the burr hole as an intramedullary nail, followed by insertion of a threaded mini fixator pin into the proximal bone fragment. Lastly, the K-wire and mini fixator pin were connected using the locked wires fixator “JuNction” (MP4 161406 kb)
Rights and permissions
About this article
Cite this article
Naito, K., Kawakita, S., Nagura, N. et al. Locked wires fixator for fractures of the distal third of the radius and ulna in children. Eur J Orthop Surg Traumatol 30, 1193–1197 (2020). https://doi.org/10.1007/s00590-020-02682-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-020-02682-7