In the framework of a quality analysis project for the improvement of digital subtraction angiography (DSA) equipment, an inventory was made of the image quality and radiation dose of DSA equipments in six hospitals in the Netherlands. The image quality was investigated with a contrast detail (CD) phantom. The entrance dose of the radiation on this phantom and the skin dose at the level of the eye lenses and the thyroid gland were measured in these hospitals using a human phantom during a standardised simulated DSA examination of the aortic arch and brachiocephalic arteries, by means of thermo-luminescence dosimeters (TLD). To establish the relation of these measurements on the human phantom and real patient examinations, the same measurements were carried out in our own hospital on 16 patients during a comparable DSA examination. To find the difference from the dose in conventional angiography (CA) the same measurements were carried out in our hospital on 11 patients during a comparable examination. These dose measurements were also carried out on the human phantom with the use of the same CA equipment. We vound large differences in image quality in the various hospitals. Within one hospital, monitor images were better than hard copy images. These differences were strongly related to the amount of radiation used, to the technique of storing the images (digital or analogue) and to the quality of the equipment used to make hard copies (the imager). Recommendations are made for improvement and quality control.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Thijssen HOM, Merx JL, Mostart JEJM, Thijssen MAO, Wong Chung R, Schoonderwaldt H, Keyser A (1988) Comparison of brachiocephalic angiography and IVDSA in the same group of patients. Neuroradiology 30:91–97
Thijssen HOM, Merx JL, Thijsen MAO, Keyser A, Schoonderwaldt H, Wong Chung R (1988) Improvement of IVDSA of the brachiocephalic arteries using a non-ionic contrast medium. Neuroradiology 30:211–213
Rose A (1974) Vision, human and electronic. Plenum, New York
Ohara K, Chan HP, Doi K, Giger ML, Fujita H (1986) Investigation of basic imaging properties in digital radiography. 8. Detection of simulated low-contrast objects in digital subtraction angiographic images. Am Assoc Phys Med 13:304–311
ICRP publication (1984) Non-stochastic effects of ionizing radiation. Ann ICRP 41:14
Starr JS, Metz CE, Lusted LB, Goodenough DJ (1975) Visual detection and localization of radiographic images. Radiology 116:533–538
Thijssen MAO (1983) Receiver operating characteristic curves in diagnostic imaging, Diagn Imag Clin Med 52:163–168
Starr JS, Metz CE, Lusted LB (1977) Comments on the generalization of receiver operating characteristic analysis to detection and localization tasks. Phys Med Biol 22:376–379
ICRP Publication (1977) Recommendations of the International Commission on Radiological Protection. Ann ICRP 26
Thijssen MAO, Rosenbush G, Gerlach H (1988) Exposure reduction in fluoroscopy. Elektromedica 4:10–17
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Thijssen, M.A.O., Thijssen, H.O.M., Merx, J.L. et al. Quality analysis of DSA equipment. Neuroradiology 30, 561–568 (1988). https://doi.org/10.1007/BF00339702
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF00339702