1 Introduction

It is well-known fact that the solar power is free and used in various conventional and non-conventional processes for years [1]. Being a solar-rich country, India is considered one among the technically developed nations for solar PV and solar thermal-related applications for domestic as well as industrial applications. Usually, on solar thermal category, flat plate solar collector (FPSC) is used as energy harvesting device for water heating purposes during day time [2]. This device is being used in rooftops of houses or apartments. Apart from water heating, FPSC is used for space heating, drying, industrial process heating. Mostly, applications requiring less than 100 °C are best to make use of FPSC during daytime. This system is a combination of various sub-systems namely collectors, storage tanks, fluid distribution systems, fluid control and transport systems.

Many research work on heat transfer analysis of flat plate solar collectors and performance have been carried out by scientists and researchers [3]. Optimization of solar power harvesting vis-a-vis heat storage has been explored and reported widely [4]. Like many other researchers, Karim and Hawalder (2004) experientially investigated flat plate solar collectors along with soft computing approach [5]. It is obvious that effective solar energy is available during sunshine hours, however, with use of effective storage system, the solar energy can be used during night time as well [6, 7].

From the few related work on this field reported, it has been observed that few researchers were mainly focused on energy analysis on various models of FPSC or solar water heaters. However, still there are many literature gaps identified such system modifications, combination of storage system analysis with FPSC, etc. Keeping in mind of dilute source of energy and unavailability during night time and applications related to simultaneous water heating and space heating at few places, special kind of system needs to be implemented. Work-related to this kind of system is also rarely mentioned in literature. Hence, present study concentrates on heat transfer modelling and analysis of FPSC with three fluid heat exchangers (TFHE) and sensible thermal storage system (STSS) for region which demand hot water and hot air round the clock. Performance analysis of a thermal system like the flat plate solar collector, heat exchanger and sensible heat storage system is executed and analyzed here using the standard theoretical model. The solar and weather data are used the simulation purposes [8]. The next section describes on mathematical modelling of three sub-systems namely, FPSC, TFHE and STSS in detail.

2 Mathematical Modelling

2.1 Flat Plate Solar Collector (FPSC)

Thermal modelling of solar collectors is presented in this sub-section. FPSC has been considered here for thermodynamic modelling and its performance analysis. A typical FPSC is considered as shown in Fig. 1. Absorber plate, copper tubes, transparent or glazing cover sheets and an insulated box are main components of it. High thermal conductivity-based sheet metal is used as absorber metal brazed with tubes or ducts below it. The surface of absorber plate is either selective coated or black with the objective to maximize heat absorption and reducing emission.

Fig. 1
An experimental setup. From the left to right it has an ascending tube of the inlet of water channel surrounded with layers of absorber, insulation, and glass cover where the solar radiation falls. The tube is connected to a tank and further to a triple fluid heat exchanger which lets water in and hot water out, and further releases hot air to the sensible thermal energy storage system.

Pictorial depiction of FPSC with TFHE and STES

The insulated box provides structural support to the whole system and minimizes the conductive heat losses in side and back sides of the FPSC. The transparent cover or glass cover sheets usually is made of low ferrite glass to maximize the transmissivity and allow sunlight to pass through to the absorber while simultaneously minimizing convective heat loss.

Usually, water like thermic fluid or nanofluid is circulated inside the tubes that are carrying the absorbed heat. The steady-state useful energy of the collector can be approximated using the conventional expression [9, 10].

$$Q_{{\text{u}}} { = }\dot{m}c_{{{\text{pw}}}} \left( {T_{{{\text{fo}}}} - T_{{{\text{fi}}}} } \right){ = }F_{{\text{R}}} A_{{\text{p}}} \left[ {S - U_{{\text{L}}} \left( {T_{{{\text{fi}}}} - T_{{\text{a}}} } \right)} \right]$$
(1)

Here, by the fluid mTfi, and Tfo are rate of mass flow, inlet and outlet temperature of fluid flowing through the tubes. Heat removal factor is denoted as FR and overall heat transfer coefficient is mentioned as UL. Ta can be the ambient temperature. Heat energy absorbed by the absorber plate can be calculated using the expression given in Eq. (2)

$$S = I_{{\text{T}}} \eta_{{{\text{opt}}}}$$
(2)

The total radiation on horizontal surface is IT and the optical efficiency of the collector thermal system is ηoptical.

Assume tilt factors are almost unity. IT and H are related by the expression given in Eq. (3).

$$H = \frac{180}{\pi }\sum\limits_{{ - \omega_{{\text{s}}} }}^{{\omega_{{\text{s}}} }} {I_{{\text{T}}} } {\text{d}}\omega$$
(3)

The hour angle is ω here, can be 15° per hour. The instantaneous thermal efficiency of the collector here by the expression given in Eq. (4).

$$\eta_{{\text{i}}} = \frac{{q_{{\text{u}}} }}{{A_{{\text{C}}} I_{{\text{T}}} }}$$
(4)

Ac is the collector area of the FPSC. It is 10% more than aperture area, Ap. The dimensions are mentioned in Table 1.

Table 1 Operating and geometrical data of the FPSC with STSS in present work

2.2 Three Fluid Heat Exchanger (TFHE)

In the multi-fluid heat exchanger here, a helical tube is inserted between two straight concentric tubes for hot fluid flow from FPSC tank. Normal water flows through the outer tube/drum and air flows in the centrally located straight tube (Fig. 1). During movement of three fluids in three pipes, heat transfer occurs between them. Heat lost from the hot fluid in helical tube is transferred to water in the outer tube/drum and air in the straight tube. By giving up heat to water carried by outer tube and air, water comes back to FPSC for another cycle. Normal water after gaining heat can be used for domestic applications. Hot air from the TFHE is used for sensible thermal energy storage systems as well as for other applications. Hence the purpose of simultaneous heating of water and air is possible with addition of this TFHE with FPSC.

Energy balance for TFHE can be written as [10]

$$\begin{aligned} & \dot{m}c_{{{\text{pw}}}} \left( {T_{{{\text{h}}1}} - T_{{{\text{h}}2}} } \right) \\ & \quad = \dot{m}_{n} c_{{{\text{pn}}}} \left( {T_{{{\text{n}}2}} - T_{{{\text{n}}1}} } \right) + \dot{m}_{{\text{a}}} c_{{{\text{pa}}}} \left( {T_{{{\text{a}}2}} - T_{{{\text{a}}1}} } \right) \\ \end{aligned}$$
(5)
$$\begin{aligned} & \left( {\frac{{\dot{m}c_{{{\text{pw}}}} \left( {T_{{{\text{h}}1}} - T_{{{\text{h}}2}} } \right)}}{{C_{{{\text{p}}\min }} \left( {T_{{{\text{h}}1}} - T_{{{\text{n}}1}} } \right)}}} \right) \\ & \quad = \frac{{1 - \exp \left( {1 - {\text{NTU}}\left( {1 + {{C_{{{\text{p}}\min }} } \mathord{\left/ {\vphantom {{C_{{{\text{p}}\min }} } {C_{{{\text{p}}\max }} }}} \right. \kern-\nulldelimiterspace} {C_{{{\text{p}}\max }} }}} \right)} \right)}}{{1 + {{C_{{{\text{p}}\min }} } \mathord{\left/ {\vphantom {{C_{{{\text{p}}\min }} } {C_{{{\text{p}}\max }} }}} \right. \kern-\nulldelimiterspace} {C_{{{\text{p}}\max }} }}}} \\ \end{aligned}$$
(6)

Here Th1, Th2, Tn1, Tn2, Ta1 and Ta2 are temperatures at inlet and outlet of hot water stream, normal water and air streamline, respectively. \(\dot{m}\), \(\dot{m}_{{\text{n}}}\), \(\dot{m}_{{\text{a}}}\) are mass flow rate of hot fluid, normal fluid and air, respectively. Corresponding specific heats are \(c_{{{\text{pw}}}}\), \(c_{{{\text{pn}}}}\) and \(c_{{{\text{pa}}}}\), respectively. \(C_{{{\text{p}}\min }}\), \(C_{{{\text{p}}\max }}\) are heat capacity rates. NTU is normal transfer unit for considered TFHE. The detailed analysis of TFHE is mentioned in Mohapatra et al. literature[11].

2.3 Sensible Thermal Storage System (STSS)

Thermal modelling of energy storage media is executed and the process, in brief, is presented here. Packed bed type sensible type of storage medium is considered in the present analysis (Fig. 1). It is least complicated compared with latent or chemical storage medium and it is inexpensive. There are drawbacks of course; sensible heat requires large quantities of materials and volumes. A quartz vessel homogeneously but randomly packed (ideally cylindrical) with alumina particles is used as STSS in the present analysis [6]. Alumina beads are mostly spherical. The dimensions are mentioned in Table 1. During charging time, heat supplied to the STSS is stored and during discharging time, the heat is carried by secondary fluid for any applications, mostly during no sun moments or night applications.

The charging and discharging period are in a transient condition. During the charging stage, energy is stored in the thermal energy storage system until the heat storage capacity of the STSS is fully used. Similarly in discharging period, energy recovery takes place. Alumina pebbles are considered as storage medium and hot air from TFHE is used as hot fluid.

Assume the bed material has infinite thermal conductivity in the radial direction and zero conductivity in the axial flow direction. Also, assume no varying heat transfer coefficient with time and space inside the bed. However, Thermal conductivity can be semi-infinite in the direction of flow. A separate energy balance for bed material and water can be approximated for an element and time as expressed in Eqs. 7 and 8 [10].

$$\left( {1 - \varepsilon } \right)\rho_{{\text{s}}} c_{{{\text{ps}}}} \frac{{\partial T_{{\text{s}}} }}{\partial t} = h_{{\text{v}}} \left( {T_{{\text{f}}} - T_{{\text{s}}} } \right)$$
(7)
$$\varepsilon \rho_{f} c_{pf} \frac{{\partial T_{f} }}{\partial t} + \frac{{4\dot{m}c_{pf} }}{{\pi D^{2} }}\frac{{\partial T_{f} }}{\partial x} = h_{v} \left( {T_{s} - T_{f} } \right)$$
(8)

where ε is void fraction, hv is the volumetric heat transfer coefficient, ρs, ρf are densities of the solid and fluid and cps. cpf are respective specific heats. Diameter of the storage unit is denoted as D and \(\dot{m}\) is rate of airflow in the storage unit. Ts, Tf are temperature of storage material (alumina particles in this case) and fluid (air in this case), respectively.

Assuming the storage system is well insulated and neglecting heat losses, two dimensionless parameters time τ and dimensionless distance X can be written as

$$\tau = \frac{{h_{{\text{v}}} t}}{{\rho_{{\text{s}}} c_{{{\text{ps}}}} \left( {1 - \varepsilon } \right)}}$$
(9)
$$X = \frac{{\pi D^{2} h_{{\text{v}}} x}}{{4\dot{m}c_{{{\text{pf}}}} }}$$
(10)

With simplification, Eqs. (7) and (8) can be written as

$$\frac{{\partial T_{{\text{s}}} }}{\partial \tau } = T_{{\text{f}}} - T_{{\text{s}}}$$
(11)
$$\frac{{\partial T_{{\text{s}}} }}{\partial X} = T_{{\text{s}}} - T_{{\text{f}}}$$
(12)

With assumption of initial temperature of solid medium at Ti, dimensionless temperature distribution may be obtained

$$\frac{{T_{{\text{s}}} - T_{{\text{i}}} }}{{T_{{{\text{fi}}}} - T_{{\text{i}}} }} = 1 - \exp^{ - (X + \tau )} \sum\limits_{n = 0}^{n = \infty } {X^{{\text{n}}} M_{{\text{n}}} \left( {X\tau } \right)}$$
(13)
$$\frac{{T_{{\text{f}}} - T_{{\text{i}}} }}{{T_{{{\text{fi}}}} - T_{{\text{i}}} }} = 1 - \exp^{ - (X + \tau )} \sum\limits_{n = 1}^{n = \infty } {X^{{\text{n}}} M_{{\text{n}}} \left( {X\tau } \right)}$$
(14)

where,

$$M_{n} \left( {X\tau } \right) = \sum\limits_{k = 0}^{k = \infty } {\frac{{\left( {X\tau } \right)}}{k!(k + n)!}}^{k}$$
(15)

Tfi is initial fluid temperature while entering the storage unit. Volumetric heat transfer coefficient, hv can be calculated with the correlation given in Eq. 16 [11].

$$\frac{{h_{{\text{v}}} d^{2} }}{{k_{{\text{f}}} }} = 1.45({\text{Re}}_{{\text{d}}} )^{0.7}$$
(16)

where Reynolds number is as follows

$${\text{Re}}_{{\text{d}}} = Gd/\mu_{{\text{f}}}$$
(17)

where G is mass flux and d is equivalent spherical diameter. \(\mu_{{\text{f}}}\) is the dynamic viscosity of the working fluid.

3 Results and Discussion

This section highlights key results of the simulation on the modelling equations mentioned in the previous section. The geometrical parameters and assumed operating parameters are mentioned in Table 1.

The solar and atmospheric data assumed for present analysis are based on weather data concerned to Indian climatic conditions. The absorber plate and tube data are considered based on the realistic conditions. Glass cover transmissivity and absorptivity-related optical efficiency value can be taken as 0.85. Based on the thermal modelling mentioned in earlier sections, temperature of the outlet fluid and efficiency are obtained and presented.

The variation of instantaneous efficiency of flat plate solar collectors with respect to the heat energy absorbed by the absorber plate is illustrated in Fig. 2. Here, the efficiency value is 31% initially and increases to 71%. In the meantime, the solar radiation increased from 500 to 900 W/m2. Moreover, the atmospheric temperature surrounding the collector increases at a lower pace. The outlet fluid temperature for different levels of heat energy absorbed in absorber plate vis-a-vis varying atmospheric temperature levels is as shown in Fig. 3. The trend seems to be almost linear kind for the both cases. The fluid temperature at the outlet increases with variations in solar radiance and atmospheric temperature.

Fig. 2
A 3-D graph of instantaneous Efficiency and atmospheric temperature versus Incident solar heat flux absorbed in the plate in watts per meter square. The X, Y, and Z axes range from 500 to 900, 0 to 80, and 20 to 40. It plots a slanting rectangular sheet of increasing slope suspended at the center and is shaded with a gradient of colors.

Efficiency variation vs. Incident solar heat flux versus atmospheric temperature

Fig. 3
A 3D graph of outlet fluid temperature in degrees celsius and atmospheric temperature versus Incident solar heat flux absorbed in the plate in watts per meter square. The X, Y, and Z axes range from 500 to 900, 60 to 76, and 20 to 40. It plots a slanting rectangular sheet suspended at the center and is shaded with a gradient of colors.

Outlet fluid temperature variation versus incident solar heat flux versus atmospheric temperature

The temperature distribution obtained analytically of three fluids along the length of the TFHE for parallel flow regime is presented in Fig. 4. The mass flow rates in three pipes are varied in such a way so as to attain air temperature 50 °C. The hot air from TFPE is being used to charge the storage medium.

Fig. 4
A graph of temperature in degrees celsius versus length along the T F H E in meters. The X axis ranges from 0 to 2. The Y axis ranges from 0 to 100. It plots three curves. Data are approximated. The hot water curve begins at (0, 90) and dips to (2, 70). The normal water and the air curve begin at (0, 20) and end at (2, 65) and (2, 50).

Variation of temperature in multi-fluid heat exchanger

Figure 5 depicts the temperature variation in the storage medium. The bed and the fluid temperature variation have been established. The graph represents the temperature along the storage section after 10 min. It is seen that temperature decreases along the length of the flow for both the storage medium and fluid. Packed bed types mainly alumina pebbles were used for storage of thermal energy. Hot air at 50 °C was used for fluid temperature during charging time where initial temperature was maintained at 20 °C. Future work may be oriented on experimentation of such solar thermal systems for simultaneous heating of water and air as well as storage for night time applications.

Fig. 5
A graph of temperature in degrees celsius versus distance along storage bed in meters. The X axis ranges from 0 to 1. The Y axis ranges from 0 to 60. It plots two curves. Data are approximated. Both the curves begin at (0, 50). Storage unit curve dips to (0, 40). The fluid curve dips to (0.5, 30) and ends at 1 meter. Both the curves resemble waves.

Fluid temperature variation in the storage medium

4 Conclusions

In search of efficient solar energy harvesting, combined effect can make the system most efficient. Analysis by heat transfer modelling of flat plate collector coupled with multi-fluid heat exchanger and heat storage system is interesting. Outlet fluid temperature for different solar energy absorbed by the plate along with the ambient temperature values were recorded accurately. FPSC was integrated with TFHE for attaining hot air and hot water. Hot air from TFPE was used for energy storage in STSS. Major observation in this work is that instantaneous efficiency can rise up to 71% at solar radiation of 900 W/m2. Increased efficiency value can be attributed to atmospheric temperature rising at a slower pace.