Abstract
Feedback of cable lengths is commonly used in the determination of the robot pose for cable-driven parallel robots (CDPRs). As such, accurate information on the absolute cable length is important. However, for most CDPRs equipped with relative encoders, the absolute cable lengths depend on the system’s initial lengths. The initial cable length, and hence the robot’s initial pose, is typically unknown. In this paper, a forward kinematics based method to determine (calibrate) for the initial cable lengths and robot pose is proposed. The calibration problem is solved as a non-linear least squares optimisation problem, where only the relative lengths of cables over any random trajectory are required and measured. The proposed method is generic in the sense that it can be applied to any type of CDPR. The simulation and experimental results for various robots show that the method can effectively and efficiently determine the initial cable lengths and pose of the cable robot. This is useful in order to obtain more accurate cable length data to be used for forward kinematics to determine the robot’s pose.
Access provided by CONRICYT-eBooks. Download conference paper PDF
Similar content being viewed by others
Keywords
- Cable-driven Parallel Robots
- Initial Cable Length
- Relational Encoding
- Robot Pose
- Forward Kinematics (FK)
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
1 Introduction
Cable-driven Parallel Robots (CDPRs) are a class of parallel manipulators where the rigid links are replaced by cables. The advantages of CDPRs include: high payload to weight ratio, large operational distances, ease of reconfigurability, ease of transportability and naturally bio-inspired. An important characteristic of CDPRs is that the cables can only apply forces in tension (positive cable force). This constraint results in the need of actuation redundancy for a CDPR to be fully constrained, creating challenges in the modelling and analysis of CDPRs.
For CDPRs, the forward kinematics (FK) problem refers to the determination of the robot pose when provided with the cable lengths and is fundamentally important in the study of CDPRs. As a parallel manipulator, the FK problem is challenging as there is no closed form analytical solution in general. Furthermore, even when solving the problem numerically there may be either no valid solutions or the existence of multiple solutions. For an n degrees-of-freedom (DoFs) CDPR actuated by m cables, the FK problem requires the determination of n unknowns (the number of DoFs) from the m equations that relate the length of cables and the system pose. As such, for fully constrained CDPRs (\(m \ge n+1\)) there will be more equations than unknowns for the FK problem.
The two primary types of approaches to solve the FK of CDPRs are analytical or numerical techniques. Analytical techniques are difficult to apply due to the nonlinearity and complexity of the kinematic equations, and have only been used for simpler CDPR systems [1, 2]. Numerical methods consider the FK relationship generically and can be used for any type of CDPR. The most common numerical approach is to solve the FK as a non-linear least squares problem [3, 4]. Other numerical techniques include using neural networks [5] and interval analysis [6].
In addition to using the forward kinematics to determine the robot pose, FK has also been used in the calibration of kinematic parameters of CDPRs. Calibration is used in CDPRs to correct for any kinematic or dynamic modelling uncertainties or errors. In [7,8,9,10,11], the attachment locations of the cables were calibrated using the cable length feedback and FK. Some studies also considered dynamic parameters such as mass and cable stiffness [12, 13].
Previous studies have focused on the calibration of static system parameters, such as the cable attachment locations and cable elasticity, which do not change significantly over time. Such parameters are slow changing and hence only need to be calibrated infrequently. However, some parameters, such as the initial robot pose and cable lengths, may be different each time the system is turned on. A majority of CDPRs use motors that equipped with encoders to obtain feedback of the cable lengths at each instance in time. While some use multi-turn absolute encoders [3], most possess only relative encoders. As a result, the initial cable lengths and robot pose are typically not known and is different each time.
One simple approach that has been used to know the initial cable lengths is to place the robot in a known pose, referred to as the initial pose, before enabling the robot. However, in some applications it may be difficult to set up the robot consistently and accurately in this way. Another approach is to employ external sensors such as camera tracking systems (external calibration). However, it is normally preferred to perform internal calibration using the CDPR’s internal sensors. In [2], the initial cable lengths calibration for a 2-DoF point mass planar CDPR actuated by 4 cables is performed. The method is based on a “jitter” approach where the lengths of two cables are perturbed and the measured lengths of the remaining two cables provide information to solve the initial pose of the system. Although effective, the approach requires the closed-form analytical solution to the forward kinematics. As such, the method would only work for simple systems, such as the 2-DoF CDPR [2].
Accurate knowledge of the initial lengths is important for two purposes. First, the initial length can provide knowledge of the initial position of the robot end-effector. Second, for CDPRs equipped with relative encoders, the initial length must be used to compute the absolute cable lengths. This absolute cable length is then used to determine the pose of the robot through FK. As such, inaccuracies in the initial length would result in error in the forward kinematics, and hence robot pose, which cannot be eliminated. In summary, the determination of the initial cable lengths in a generic manner for any type of CDPR without requiring the system to begin at a known position has not been studied thus far.
In this paper, a generic method to calibrate for the initial cable lengths for a CDPR with relative encoders using a forward kinematics approach is proposed. Without assuming any initial robot pose, the CDPR is commanded to perform any random motion in a way that excites all of the system’s degrees-of-freedom. The resulting relative changes in cable lengths are captured and then used to calibrate for the initial cable lengths and initial pose. This method assumes that the attachment locations of the cables are known beforehand. The proposed approach is validated both in simulation and hardware experiments for different CDPRs to show its effectiveness and ability to be generically used on different systems. Furthermore, the proposed algorithm is implemented in the open-source cable-robot software CASPR [14] and the source-code is publicly availableFootnote 1.
2 Numerical Forward Kinematics Formulations
It was shown in [15] that the kinematics of any generalised CDPR models (n DoF actuated by m cables), as shown in Fig. 1, could be expressed as
where \(\mathbf {l} = [l_1 ~ \cdots ~ l_m]^T \in \mathbb {R}^m\) and \(\mathbf {q} = [q_1 ~ \cdots ~ q_n]^T \in \mathbb {R}^n\) are the vector of cable lengths and pose of the system, respectively.
Taking the time derivative of (1) results in the well established relationship
where \(L \in \mathbb {R}^{m \times n}\) is the Jacobian matrix relating the pose and cable length derivatives.
The inverse kinematics problem, the determination of cable lengths \(\mathbf {l}\) for a given pose \(\mathbf {q}\), is a trivial problem using (1). However, the forward kinematics (FK) problem is much more challenging as the inverse of the kinematic relationship \(\mathbf {q} = \mathbf {f}^{-1}(\mathbf {l})\) does not have an analytical closed-form solution in general. One common way to solve the FK problem is to formulate the optimisation problem:
In general, the problem in (3) is a non-linear least squares problem that can be solved using techniques such as the Levenberg-Marquardt Algorithm. The poses which result in a zero objective function value are solutions to the FK problem since \(\left\| \mathbf {l} - \mathbf {f}(\mathbf {q}) \right\| ^2 = 0 \Leftrightarrow \mathbf {l} = \mathbf {f}(\mathbf {q})\). However, it is difficult to achieve a zero objective function value in real systems due to the presence of sensor noise. As such, in practice the solution (minimum) of (3) with a small objective function value is taken as the solution to the FK problem since \(\left\| \mathbf {l} - \mathbf {f}(\mathbf {q}) \right\| ^2 \approx 0 \Leftrightarrow \mathbf {l} \approx \mathbf {f}(\mathbf {q}) \). Note again that the FK problem, from (1), has m equations and n unknown variables. For fully constrained systems \(m \ge n+1\), resulting in an overdetermined problem.
3 Least Squares Problems for Initial Lengths
In the FK problem presented in (3), it is assumed that the absolute length of the cables \(\mathbf {l}(t)\) is known at all times. However, for CDPRs with relative encoders, only the relative length of the cables \(\mathbf {l}_r(t)\) since \(t = 0\) is known. The relationship between the absolute and relative cable lengths at any instance in time t can be described as
where \(\mathbf {l}_0 = \mathbf {l}(0)\) is the vector of initial cable lengths of the CDPR since \(\mathbf {l}_r(0) = \mathbf {0}\). It can be observed that (4) contains \(n + m\) unknowns (\(\mathbf {q}\) and \(\mathbf {l}_0\)) but only with m equations. As such, there are not enough equations to uniquely determine both the initial cable length and pose. One important property that can be taken advantage of is that after the system is turned on, \(\mathbf {l}_0\) is time invariant until the system is restarted.
As such, initial length calibration and FK problem can be simultaneously solved by considering the problem in (4) over a set of different time instances, or samples, for a trajectory. Assuming that p different instances in time \(t \in \{t_1, t_2, \cdots , t_p\}\) are selected to solve for the initial length and FK problem, the following non-linear system of equations can be expressed as
The equations in (5) possess a total of \(m + n \times p\) unknowns (the initial length \(\mathbf {l}_0\) and the poses \(\mathbf {q}(t)\) at each time instance \(t \in \{t_1, t_2, \cdots , t_p\}\)) and \(m \times p\) equations. The vector of unknown variables for (5) can be denoted as \(\mathbf {x} = [ \mathbf {l}_0^T ~ \mathbf {q}^T(t_1) ~ \mathbf {q}^T(t_2) ~ \cdots ~ \mathbf {q}^T(t_p)]^T\).
In a similar manner to (3), the initial length calibration problem can be solved through the non-linear least squares (NLLS) optimisation problem
where \(\mathbf {q}_i := \mathbf {q}(t_i)\). Since the problem (6) is an NLLS problem, numerical methods such as the Levenberg-Marquardt algorithm can be employed. For such problems and approaches, the initial guess of the solution and the Jacobian value of the NLLS objective function would significantly increase the computational time and accuracy of the non-linear optimisation problem. Expressing (6) in the standard form
the non-linear vector function can be equivalently expressed from (6) as
From (8), the problem Jacobian \(\frac{\partial \mathbf {g}}{\partial \mathbf {x}}\) can be expressed analytically as
It will be shown in the results of Sect. 4 that the use of the Jacobian matrix (9) significantly reduces the required optimisation time to perform the initial length calibration and also is more robust to inaccurate initial guesses of \(\mathbf {x}\).
In order to solve (6), a sufficient number of points p in the random motion should be sampled such that the number of equations mp is equal to or greater than the number of unknowns \(m + np\), that is, \(m p \ge m + np\). As such, the minimum number of trajectory points \(p \in \mathbb {Z}\) that should be selected should be \(p \ge m/(m-n)\). As will be shown in Sect. 4, the selection of the number of sample trajectory points p for the initial length calibration has a significant effect on the computational speed and effectiveness. Moreover, it is important to note that the sampled motion points of the random motion must excite the different degrees-of-freedom such that the NLLS optimisation of (6) have sufficient measurements to recover \(\mathbf {x}\).
In summary, the proposed method uses the fact that the lengths of different cables for a trajectory must be related (kinematically consistent) due to the CDPR cable attachments. As such, the calibration problem is equivalent to determining the set of initial lengths that produce kinematically consistent cable lengths.
4 Simulation Results
The two simulation examples, performed through CASPR [14], aim to show: (1) the ability to calibrate for uncertain initial poses; (2) the effectiveness and efficiency for different number of samples; and (3) the short calibration time required.
4.1 Planar Robot Example
Figure 2(a) shows the 3-DoF planar robot model actuated by 4 cables, where \(\mathbf {q} = [x~~y~~\theta ]^T\) represent translations (x and y) and orientation \(\theta \) of the robot, respectively.
To demonstrate the initial length calibration, the reference trajectory as shown in Fig. 3(a), with initial pose \(\mathbf {q}(t=0) = [0.3 ~~ 0.6 ~~ 0.1]^T\) and final pose \(\mathbf {q}(t=4) = [0.2 ~~ 0.3 ~~ 0.2]^T\), will be used. At pose the initial pose \(\mathbf {q}(t=0)\), the cable lengths can be determined using inverse kinematics as \(\mathbf {l}_0 = [0.578~~0.8176~~0.6946~~0.4099]^T\). Using \(\mathbf {l}_0\) and the cable length trajectory \(\mathbf {l}(t)\) obtained from computing the inverse kinematics \(\mathbf {q}(t)\) (Fig. 3(a)), the relative cable lengths \(\mathbf {l}_r(t)\) (emulating the cable length feedback from relative encoders) can be determined using (4).
Since the initial length is unknown, without loss of generality it will be assumed for this example that \(\bar{\mathbf {l}}_0 = [0.5~~0.5~~0.5~~0.5]^T\). Using this, the absolute cable lengths trajectory with the erroneous initial length \(\bar{\mathbf {l}}(t)\) can be determined as \(\bar{\mathbf {l}}(t) = \bar{\mathbf {l}}_0 + \mathbf {l}_r(t)\). Using \(\bar{\mathbf {l}}(t)\), the resulting joint space trajectory \(\bar{\mathbf {q}}(t)\), shown in Fig. 3(b), was determined using the NLLS FK method from (3). As expected, it can be clearly observed that the resulting trajectory \(\bar{\mathbf {q}}(t)\) is significantly different to that of \(\mathbf {q}(t)\), demonstrating the impact in FK feedback when the initial lengths and pose are unknown. Figure 4(a) shows the error value of the FK optimisation result \(\bar{\mathbf {e}}(t) = \left\| \bar{\mathbf {l}}(t) - \mathbf {f}(\bar{\mathbf {q}}(t)) \right\| \), confirming the error observed in the trajectory of \(\bar{\mathbf {q}}(t)\).
Using the calibration method presented in Sect. 3, the initial cable lengths \(\mathbf {l}_0^*\) is determined using only the relative cable length \(\mathbf {l}_r(t)\) as the input to the NLLS problem (6). The relative length profile \(\mathbf {l}_r(t)\) consists of a total of \(p=401\) time samples (from \(t = 0\) s to \(t = 4\) s at \(\varDelta t = 0.01\) s). With this sample size, the problem (6) will have 1207 unknowns. To solution \(\mathbf {x}^*\) to calibration problem resulted in the initial cable lengths solution of \(\mathbf {l}_0^* = [0.578~~0.8176~~0.6946~~0.4099]^T\), with an error norm compared with the nominal solution \(\mathbf {l}_0\) of \(\left\| \mathbf {l}_0 - \mathbf {l}_0^* \right\| = 4.7868 \times 10^{-9}\). Using this solution and FK, the absolute cable length \(\mathbf {l}^*(t) = \mathbf {l}_0^* + \mathbf {l}_r(t)\) produced the joint space trajectory of the calibration motion \(\mathbf {q}^*(t)\) and the resulting FK error norm \(\mathbf {e}^*(t) = \left\| \mathbf {l}^*(t) - \mathbf {f}(\mathbf {q}^*(t)) \right\| \) shown in Figs. 3(c) and 4(b), respectively. These results show that the proposed method is able to determine the initial cable lengths, initial robot pose and also the calibration trajectory motion without prior knowledge of the initial state or the calibration motion to be performed.
In the results of Figs. 3 and 4, every point on the calibration motion \(p = 401\) was used in the calibration optimisation. However, it is also possible to take a subset sample of \(\mathbf {l}_r(t)\) to use within the calibration. Table 1 shows the properties of the calibration method for different sample frequency (every N of the trajectory points are taken). The comparison results show that if not enough samples are taken, such as \(p = 5\) and 9 for \(N = 100\) and 50, respectively, the initial cable lengths cannot be correctly determined. It can also be observed that for larger samples the computational time is higher, although no significant increase in accuracy is achieved. However, it is worth noting that the calibration time of \(p = 401\) over a 4 s motion is only 5.28 s, making this method very practical in use within real applications.
As discussed above, the effectiveness and efficiency of the NLLS optimisation problem can be improved by providing an initial guess \(\mathbf {x}_{guess}\) and the Jacobian matrix (9). In the above simulations, the initial cable lengths were simply always set as a constant value of \(\bar{\mathbf {l}}_0 = [0.5~~0.5~~0.5~~0.5]^T\) regardless of the calibration motion. For the initial guess of the trajectory, the erroneous trajectory \(\bar{\mathbf {q}}(t)\) determined from \(\bar{\mathbf {l}}_0\) and FK (Fig. 3(b)). This shows that no trajectory specific information about the initial cable lengths or pose are required for the calibration method.
4.2 Spatial Robot Example
As no assumptions on the robot type are required, the proposed approach can be used for any CDPR. In this example, the initial length calibration of the 6-DoF spatial cable robot CoGiRo [16] actuated by 8 cables, as shown in Fig. 2(b), is demonstrated. The generalised coordinates of the robot can be described by \(\mathbf {q} = [x~~y~~z~~\alpha ~~\beta ~~\gamma ]^T\), where x, y, z are the translational DoFs and \(\alpha , \beta ,\gamma \) are the xyz-Euler angles that represent the system orientation. The initial length calibration for the CoGiRo robot is demonstrated for three different trajectories beginning at different poses \(\mathbf {q}_0\) with different initial cable lengths \(\mathbf {l}_0\), as observed in Fig. 5.
In a similar manner as Sect. 4.1, the calibration using the relative lengths of the trajectories in Fig. 5 was performed. For the calibration of the CoGiRo, a sample frequency of \(N = 10\) was used, such that each calibration trajectory motion has \(p = 41\) sample points. The results for all three trajectories are summarised in Table 2 and Fig. 6, and it can be observed that the calibration method successfully determined the initial cable lengths \(\mathbf {l}_0\) for different robots and calibration trajectories.
5 Experimental Results
This section illustrates the proposed approach on a real CDPR, the 2-link 4-DoF 6-cable BioMuscular Arm (BM-Arm), as shown in Fig. 7(a), actuated by the MYO-muscle actuators [17]. The robot consists of two links, connected by a spherical joint and a revolute joint. Hence the generalised coordinates of the BM-Arm can be expressed as \(\mathbf {q} = [\alpha ~~\beta ~~\gamma ~~\theta ]^T\), representing the xyz-Euler angles of the spherical joint and the angle of the revolute joint, respectively.
For the BM-Arm experiment, the robot was set into force control mode with a low constant force value in each cable in order to maintain the robot in equilibrium or a slow moving state. The position of the robot, and hence cable lengths, was unknown initially. The BM-Arm was then manipulated physically in a random motion, while the relative cable lengths \(\mathbf {l}_r(t)\) were measured using a relative encoder by the MYO-muscles. This procedure was performed for different robot poses and different random trajectories (of approximately 30 s each). This calibration procedure would be very similar to how the proposed method is envisioned to be used to quickly calibrate a real CDPR every time it is turned on.
To validate the calibration approach, an OptiTrack motion capture system with four cameras was installed onto the BM-Arm to capture the orientation (\(\mathbf {q}=[\alpha ~~\beta ~~\gamma ]^T\), the xyz-Euler angles) of the link 1 (markers are shown in Fig. 7(a)) during the manual motion (as the calibration trajectory). Table 3 shows the comparison results of four different trajectories where the CDPR begins in various poses.
From the results, it can be observed that the initial length calibration method is able to resolve for \(\mathbf {l}_0\) even when starting pose is unknown. Although the method is able to clearly able to solve for the initial cable lengths and pose, it should be noted that some errors still existed. Such errors may exist due to various reasons, including: (1) errors in the cable length feedback measurement \(\mathbf {l}_r(t)\); (2) errors in the calibration of the motion capture system and noise due to reflections and disturbances; and (3) wrapping and slack in the cables. Moreover, it is important to note that adequate calibration motion in all of the CDPR’s DoFs, in order to obtain sufficient data for the NLLS optimisation, must be performed.
The joint space trajectories for trajectory 2 in Table 3 for both the motion capture system and FK using the calibrated initial cable lengths are shown in Fig. 8 and shows that indeed the calibration method is capable of determining correct initial lengths by only using internal sensors (motor encoders) of the CDPR system.
6 Conclusion
In this paper, a novel FK-based calibration method for the initial cable lengths of arbitrary CDPRs is proposed. For systems with relative feedback, the initial cable lengths is required to determine the absolute lengths to be used in the FK analysis. The simulation and experiment examples show that the proposed method is effective in determining the initial cable lengths and requiring only a short random calibration motion. Furthermore, the computational time required for the calibration is short (less than 5 s), making it practical in real-life use. Future work will focus on the analysis on the requirements of suitable calibration trajectories.
Notes
- 1.
CASPR and the presented work can be accessed at https://www.github.com/darwinlau/CASPR.
References
Bosscher, P., Williams II, R.L., Bryson, L.S., Castro-Lacouture, D.: Cable-suspended robotic contour crafting system. Autom. Constr. 17(1), 45–55 (2007)
Borgstrom, P.H., Jordan, B.L., Borgstrom, B.J., Stealey, M.J., Sukhatme, G.S., Batalin, M.A., Kaiser, W.J.: NIMS-PL: a cable-driven robot with self-calibration capabilities. IEEE Trans. Robot. 25(5), 1005–1015 (2009)
Pott, A.: An algorithm for real-time forward kinematics of cable-driven parallel robots. In: Lenarcic, J., Stanisic, M.M. (eds.) Advances in Robot Kinematics: Motion in Man and Machine, pp. 529–538. Springer, Dordrecht (2010)
Pott, A., Schmidt, V.: On the forward kinematics of cable-driven parallel robots. In: Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 3182–3187 (2015)
Schmidt, V., Müller, B., Pott, A.: Solving the forward kinematics of cable-driven parallel robots with neural networks and interval arithmetic. In: Thomas, F., Gracia, A.P. (eds.) Computational Kinematics. Mechanisms and Machine Science, vol. 15, pp. 103–110. Springer, Dordrecht (2014)
Merlet, J.-P., dit Sandretto, J.A.: The forward kinematics of cable-driven parallel robots with sagging cables. In: Pott, A., Bruckmann, T. (eds.) Cable-Driven Parallel Robots. Mechanisms and Machine Science, vol. 32, pp. 3–15. Springer International Publishing, Cham (2015)
Mustafa, S.K., Yang, G., Yeo, S.H., Lin, W., Chen, I.-M.: Self-calibration of a biologically inspired 7 DOF cable-driven robotic arm. IEEE/ASME Trans. Mechatronics 13(1), 66–75 (2008)
Miermeister, P., Pott, A., Verl, A.: Auto-calibration method for overconstrained cable-driven parallel robots. In: Proceedings of the 7th German Conference on ROBOTIK, pp. 301–306 (2012)
Chen, Q., Chen, W., Yang, G., Liu, R.: An integrated two-level self-calibration method for a cable-driven humanoid arm. IEEE Trans. Autom. Sci. Eng. 10(2), 380–391 (2013)
dit Sandretto, J.A., Daney, D., Gouttefarde, M.: Calibration of a fully-constrained parallel cable-driven robot. In: Padois, V., Bidaud, P., Khatib, O. (eds.) Romansy 19 Robot Design, Dynamics and Control. CISM International Centre for Mechanical Sciences, vol. 544, pp. 77–84. Springer, Heidelberg (2013)
Surdilovic, D., Radojicic, J., Bremer, N.: Efficient calibration of cable-driven parallel robots with variable structure. In: Pott, A., Bruckmann, T. (eds.) Cable-Driven Parallel Robots. Mechanisms and Machine Science, vol. 32, pp. 113–128. Springer International Publishing, Cham (2015)
Miermeister, P., Pott, A.: Auto calibration method for cable-driven parallel robots using force sensors. In: Lenarcic, J., Husty, M. (eds.) Latest Advances in Robot Kinematics, pp. 269–276. Springer, Dordrecht (2012)
Kraus, W., Schmidt, V., Rajendra, P., Pott, A.: Load identification and compensation for a cable-driven parallel robot. In: Proceedings of the IEEE International Conference on Robotics and Automation, pp. 2485–2490 (2013)
Lau, D., Eden, J., Tan, Y., Oetomo, D.: CASPR: a comprehensive cable-robot analysis and simulation platform for the research of cable-driven parallel robots. In: Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 3004–3011 (2016)
Lau, D., Oetomo, D., Halgamuge, S.K.: Generalized modeling of multilink cable-driven manipulators with arbitrary routing using the cable-routing matrix. IEEE Trans. Robot. 29(5), 1102–1113 (2013)
Lamaury, J., Gouttefarde, M.: Control of a large redundantly actuated cable-suspended parallel robot. In: Proceedings of the IEEE International Conference on Robotics and Automation, pp. 4659–4664 (2013)
Marques, H.G., Maufroy, C., Lenz, A., Dalamagkidis, K., Culha, U., Siee, M., Bremner, P., The MYOROBOTICS Project Team: MYOROBOTICS: a modular toolkit for legged locomotion research using musculoskeletal designs. In: Proceedings of the 6th International Symposium on Adaptive Motion of Animals and Machines (AMAM 2013) (2013)
Acknowledgements
The work was supported by the grants from the Early Career Scheme sponsored by the Research Grants Council (Reference No. 24200516) and the Germany/Hong Kong Joint Research Scheme sponsored by the Research Grants Council of Hong Kong and the German Academic Exchange Service of Germany (Reference No. G-CUHK410/16). Acknowledgements to the CUHK T-Stone Robotics Institute for supporting this work, and Chen Song for assisting in the collection of results of the BM-Arm.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this paper
Cite this paper
Lau, D. (2018). Initial Length and Pose Calibration for Cable-Driven Parallel Robots with Relative Length Feedback. In: Gosselin, C., Cardou, P., Bruckmann, T., Pott, A. (eds) Cable-Driven Parallel Robots. Mechanisms and Machine Science, vol 53. Springer, Cham. https://doi.org/10.1007/978-3-319-61431-1_13
Download citation
DOI: https://doi.org/10.1007/978-3-319-61431-1_13
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-61430-4
Online ISBN: 978-3-319-61431-1
eBook Packages: EngineeringEngineering (R0)