Abstract
The degree of precision in measuring accurate masses in LC MS/MS-based metabolomics experiments is a determinant in the successful identification of the metabolites present in the original extract. Using the methods described here, complex broccoli extracts containing hundreds of small-molecule compounds (mass range 100–1,400 Da) can be profiled at resolutions up to 100,000 (full width half maximum, FWHM), useful for accurate and sensitive relative quantification experiments. Using external instrument calibration, analyte masses can be measured with high (sub-ppm to a maximum of 2 ppm) accuracy, leading to compound identifications based on elemental composition analysis. Unambiguous identification of four analytes (citric acid, chlorogenic acid, phenylalanine, and UDP-d-glucose) is used to validate the performance of the different MS/MS fragmentation regimes. Identifications are carried out either via resonance excitation collision induced dissociation (CID) or via higher energy collision dissociation (HCD) experiments, and validated by infrared multiphoton dissociation (IRMPD) fragmentation of standards. Such results, obtained on both hybrid and non-hybrid systems from metabolite profiling and identification experiments, provide evidence that the strategies selected can be successfully applied to other LC-MS based projects for plant metabolomic studies.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Kitano, H. (2002) Systems biology: a brief overview Science 295, 1662–1664.
van der Greef, J., Stroobant, P., van der Heijden (2004) The role of analytical sciences in medical systems biology. Curr Opin Chem Biol 8, 559–565.
Dettmer, K., Aronov, P. A., and Hammock, B. D. (2007) Mass spectrometry-based metabolomics. Mass Spectrom Rev. 26, 51–78.
Novotny, M. V., Soini, H. A., and Mechref, Y. (2008) Biochemical individuality reflected in chromatographic, electrophoretic and mass-spectrometric profiles. J Chromatogr B Analyt Technol Biomed Life Sci. 866, 26–47.
Kell, D. B., Brown, M., Davey, H. M., Dunn, W. B., Spasic, I., and Oliver, S. G. (2005) Metabolic footprinting and systems biology: the medium is the message. Nat Rev Microbiol. 3, 557–565.
Beckmann, M., Parker, D., Enot, D. P., Duval, E., and Draper, J. (2008) High-throughput, nontargeted metabolite fingerprinting using nominal mass flow injection electrospray mass spectrometry. Nat Protoc. 3, 486–504.
van der Werf, M. J., Overkamp, K. M., Muilwijk, B., Coulier, L., and Hankemeier, T. (2007) Microbial metabolomics: toward a platform with full metabolome coverage. Anal Biochem. 370, 17–25.
Scheltema, R. A., Kamleh, A., Wildridge, D., Ebikeme, C., Watson, D. G., Barrett, M. P., Jansen, R. C., and Breitling, R. (2008) Increasing the mass accuracy of high-resolution LC-MS data using background ions: a case study on the LTQ-Orbitrap. Proteomics 8, 4647–4656.
Kothari, S., Song, Q., Xia, Y., Fico, M., Taylor, D., Amy, J. W., Stafford, G., and Cooks, R. G. (2009) Multiplexed four-channel rectilinear ion trap mass spectrometer. Anal Chem. 81, 1570–1579.
Enot, D. P., Lin, W., Beckmann, M., Parker, D., Overy, D. P., and Draper, J. (2008) Preprocessing, classification modeling and feature selection using flow injection electrospray mass spectrometry metabolite fingerprint data. Nat Protoc. 3, 446–470.
Xu, E. Y., Schaefer, W. H., and Xu, Q. (2009) Metabolomics in pharmaceutical research and development: metabolites, mechanisms and pathways. Curr Opin Drug Discov. Devel. 12, 40–52.
Spratlin, J. L., Serkova, N. J., and Eckhardt, S. G. (2009) Clinical applications of metabolomics in oncology: a review. Clin Cancer Res. 15, 431–440.
Jacobs, A. (2009) An FDA perspective on the nonclinical use of the X-Omics technologies and the safety of new drugs. Toxicol Lett. 186, 32–35.
Hall, R. D., Brouwer, I. D., and Fitzgerald, M. A. (2008) Plant metabolomics and its potential application for human nutrition. Physiol Plant. 132, 162–175.
Damoc, E., Scigelova, M., Giannakopulos, A. E., Moehring, T., Pehal, F., and Hornshaw, M. (2008) Direct analysis of red wine using ultra-fast chromatography and high resolution mass spectrometry. Thermo Scientific Application Note 30173.
Makarov, A., Denisov, E., Lange, O., and Horning, S. (2006) Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer. J Am Soc Mass Spectrom. 17, 977–982.
Stafford, G. C., Taylor, D. M., Bradshaw, S. C., and Syka, J. E. P. (1987) Enhanced sensitivity and dynamic range on an ion trap mass spectrometer with automatic gain control. Proc. 35th Annual Conference of the American Society for Mass Spectrometry, Denver, CO 775–776.
Acknowledgements
The authors would like to thank Michael Athanas from VAST Scientific, Robert Mistrik from HighChem, Helen Jenkins and Robert Hall as partners in the META-PHOR project, for advice and useful discussions. This work was in part supported by the EU FP VI project META-PHOR (FOOD-CT-2006-036220).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2011 Springer Science+Business Media, LLC
About this protocol
Cite this protocol
Oppermann, M., Damoc, N.E., Crone, C., Moehring, T., Muenster, H., Hornshaw, M. (2011). High Precision Measurement and Fragmentation Analysis for Metabolite Identification. In: Hardy, N., Hall, R. (eds) Plant Metabolomics. Methods in Molecular Biology, vol 860. Humana Press. https://doi.org/10.1007/978-1-61779-594-7_10
Download citation
DOI: https://doi.org/10.1007/978-1-61779-594-7_10
Published:
Publisher Name: Humana Press
Print ISBN: 978-1-61779-593-0
Online ISBN: 978-1-61779-594-7
eBook Packages: Springer Protocols