Abstract
A microwave add digestion method for the preparation of biological samples for PIXE analysis is presented. The precision and accuracy of the entire PIXE analytical procedure, including the microwave digestion step, were evaluated by analyzing eight certified reference materials. For elements heavier than K, and for concentration levels from 2 jxg/g upward, the total random error of a single analysis is in the range of 2 –5%. The accuracy is better than 5%. The detection limits are down to 0.3 μg/g.
Author to whom all correspondence and reprint requests should be addressed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
S. A. E. Johansson and J. IL Campbell, PIXE: A Novel Technique for Elemental Analysis, Wiley, Chichester (1988).
W. Maenhaut, Nucl. Instr. Methods B35, 388 (1988).
N. F. Mangelson, M, W. Hill, K. K. Nielson, and J. F. Ryder, Nucl. Instr. Methods 142, 133 (1977).
W. Maenhaut, L. De Reu, H. A, Van Rinsvelt, J. Cafmeyer, and P. Van Espen, Nucl. Instr. Methods 168, 557 (1980).
J. Pallon and K. G. Malmqvist, Nucl. Instr. Methods 181, 71 (1981).
W. Maenhaut, L. De Reu, and J. Vandenhaute, Nucl. Instr. Methods B3,135 (1984).
J. Galuszka, L. Jarczyk, E. Rokita, A. Strzalkowski, and M. Sych, Nucl. Instr. Methods B3, 141 (1984).
E. Clayton, Nucl. Instr. Methods B22, 145 (1987).
W, Maenhaut, J. Vandenhaute, and H. Duflou, Fresenius Z. Anal. Chem. 326, 736 (1987).
H. Duflou, W. Maenhaut, and J. De Reuck, Biol Trace Elem. Res. 13,1 (1987).
H. M. Kingston and L. B. Jassie, Introduction to Microwave Sample Preparation, ACS Professional Reference Book, Washington (1988).
H. Duflou, PhD thesis, University of Ghent, 1988.
W. Maenhaut and H. Raemdonck, Nucl. Instr. Methods B1, 123 (1984).
W. Maenhaut and J. Vandenhaute, Bull Soc. Chim. Belg. 95, 407 (1986).
E. S. Gladney, C. E. Burns, D. R. Perrin, I. Roelandts, and T. E. Gills, 1982 Compilation of Elemental Concentration Data for NBS Biological, Geological, and Environmental Standard Reference Materials, NBS (US) Spec. Publ. 260-88 (1984).
J. L. Campbell, W. Maenhaut, E. Bombelka, E. Clayton, K. Malmqvist, J. A. Maxwell, J. Pallon, and J. Vandenhaute, Nucl. Instr. Methods B14,204 (1986).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1990 Springer Science+Business Media New York
About this chapter
Cite this chapter
Pinheiro, T., Duflou, H., Maenhaut, W. (1990). Applicability of Microwave Acid Digestion to Sample Preparation of Biological Materials for Analysis by Particle-Induced X-Ray Emission (PIXE). In: Zeisler, R., Guinn, V.P. (eds) Nuclear Analytical Methods in the Life Sciences. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-4612-0473-2_64
Download citation
DOI: https://doi.org/10.1007/978-1-4612-0473-2_64
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-4612-6777-5
Online ISBN: 978-1-4612-0473-2