Abstract
Automatic generation control (AGC) serves a great performance in conventional power systems for delivering the reliability of power supply to all consumers. The toughest task in the multi-area power system is to stabilize the changes in frequency and inter-area line power. In this work, proportional integral (PI), proportional integral derivative (PID), and 2-degree freedom of PID (2-DOF-PID) controllers are proposed in AGC system for nullifying the unnecessary oscillations in frequency and tie-line power. When the system would be complex, then these controllers do not give efficient outcomes because of it having fixed gain values. Therefore, in this work, particle swarm optimization (PSO) algorithm is formulated for tuning the gain values of the suggested controllers in multi-area interconnected system. In order to alleviate the frequency and inter-area power line deviations, the tuned 2-DOF-PID controller has rendered a better dynamic performance with respect to settling time, overshoot and undershoot. Likewise, the robustness of the system has ascertained while fluctuating the loading circumstances and system specifications up ±25% from their prescribed values which helped to exhibit the ability of the recommended method. Finally, the simulation outcomes disclosed the PSO optimized 2-DOF-PID has given the favorable dynamic performance over the other control approaches.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Dreidy M, Mokhlis H, Mekhilef S (2017) Inertia response and frequency control techniques for renewable energy sources: a review. Renew Sustain Energy Rev 69:144–155
Jood P, Aggarwal SK, Chopra V (2019) Performance assessment of a neuro-fuzzy load frequency controller in the presence of system non-linearities and renewable penetration. Comput Electr Eng 74:362–368
Aziz A, Stojcevski A (2018) Intelligent frequency regulation in the wind integrated control area. Comput Electr Eng 72:324–347
Elsisi M, Bazmohammadi N, Guerrero JM, Ebrahim MA (2021) Energy management of controllable loads in multi-area power systems with wind power penetration based on new supervisor fuzzy nonlinear sliding mode control. Energy 221:119867
Prasad S, Purwar S, Kishor N (2019) Load frequency regulation using observer based non-linear sliding mode control. Int J Electr Power Energy Syst 104:178–193
Singh VP, Kishor N, Samuel P (2017) Improved load frequency control of power system using LMI based PID approach. J Franklin Inst 354(15):6805–6830
Sahu RK, Sekhar GTC, Panda S (2015) DE optimized fuzzy PID controller with derivative filter for LFC of multi source power system in deregulated environment. Ain Shams Eng J 6(2):511–530
Yakine NEL, Kouba MM, Hasni M, Boudour M (2018) A novel optimal combined fuzzy PID controller employing dragonfly algorithm for solving automatic generation control problem. Electr Power Compon Syst 46(19–20):2054–2070
Ali ES, Abd-Elazim SM (2011) Bacteria foraging optimization algorithm based load frequency controller for interconnected power system. Int J Electr Power Energy Syst 33(3):633–638
Guha D, Roy PK, Benerjee S (2018) Optimal tuning of 3 degree-of-freedom proportional integral derivative controller for hybrid distributed power system using dragonfly algorithm. Comput Electr Eng 72:137–153
Kumar A, Shuhag S (2019) mpact of TCPS, SMES and DFIG on load frequency control of nonlinear power system using differential evolution algorithm. J Inst Eng Ser B 100(2):153–167
Sahu RK, Panda S, Rout UK, Sahoo DK (2016) Teaching learning based optimization algorithm for automatic generation control of power system using 2-DOF PID controller. Int J Electr Power Energy Syst 77:287–301
Panwar A, Sharma G, Nasiruddin I, Bansal RC (2018) Frequency stabilization of hydro–hydro power system using hybrid bacteria foraging PSO with UPFC and HAE. Electr Power Syst Res 161:74–85
Huang Z, Chen Z, Zheng Y, Sun M, Sun Q (2021) Optimal design of load frequency active disturbance rejection control via double-chains quantum genetic algorithm. Neural Comput Appl 33(8):3325–3345
Sharma Y, Saikia LC (2015) Automatic generation control of a multi-area ST–Thermal power system using Grey Wolf Optimizer algorithm based classical controllers. Int J Electr Power Energy Syst 73:853–862
Panda S, Mohanty B, Hota PK (2013) Hybrid BFOA-PSO algorithm for automatic generation control of linear and nonlinear interconnected power systems. Appl Soft Comput J 13(12):4718–4730
Wang X, Wang Y, Liu Y (2020) Dynamic load frequency control for high-penetration wind power considering wind turbine fatigue load. Int J Electr Power Energy Syst 117:105696
Mishra D, Sahu PC, Prusty RC, Panda S (2021) A fuzzy adaptive fractional order-PID controller for frequency control of an islanded microgrid under stochastic wind/solar uncertainties. Int J Ambient Energy, 1–10
Sivalingam R, Chinnamuthu S, Dash SS (2017) A modified whale optimization algorithm-based adaptive fuzzy logic PID controller for load frequency control of autonomous power generation systems. Automatika 58(4):410–421
Bagheri A, Jabbari A, Mobayen S (2021) An intelligent ABC-based terminal sliding mode controller for load-frequency control of islanded micro-grids. Sustain Cities Soc 64:102544
Sahu RK, Panda S, Rout UK (2013) DE optimized parallel 2-DOF PID controller for load frequency control of power system with governor dead-band nonlinearity. Int J Electr Power Energy Syst 49(1):19–33
Yousri D, Babu TS, Fathy A (2020) Recent methodology based Harris Hawks optimizer for designing load frequency control incorporated in multi-interconnected renewable energy plants. Sustain Energy Grids Netw 22:100352
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Appendix
Appendix
System specifications | f = 60 Hz, each area power rating = 1200 MW, Base power = 1200 MW |
Thermal and hydro plant parameters | TH1 = TH2 = 0.08 s, Tt1 = Tt2 = 0.4 s, KP1 = KP2 = 120 Hz/p.u, TP1 = TP2 = 20 s, R1 = R2 = R3 = R4 = 2.4 Hz/p.u, B1 = B2 = 0.425 p.u MW/Hz, TR1 = TR2 = 0.513 s, T1 = T2 = T3 = T4 = 10 s, K1 = −0.3, K2 = −0.2622, 2ΠT12 = 0.545p.u MW/Hz a12 = a21 = −1,TW1 = TW2 = 1 s, D = 0.8 s |
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Peddakapu, K., Mohamed, M.R., Srinivasarao, P., Kishore, D.J.K., Koteswararao, D.A., Swamy, P.S.P.R. (2022). Performance of 2-DOF PID Controller in AGC of Two Area Interconnected Power System Using PSO Algorithm. In: Md. Zain, Z., Sulaiman, M.H., Mohamed, A.I., Bakar, M.S., Ramli, M.S. (eds) Proceedings of the 6th International Conference on Electrical, Control and Computer Engineering. Lecture Notes in Electrical Engineering, vol 842. Springer, Singapore. https://doi.org/10.1007/978-981-16-8690-0_12
Download citation
DOI: https://doi.org/10.1007/978-981-16-8690-0_12
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-8689-4
Online ISBN: 978-981-16-8690-0
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)