Abstract
The seven-storey reinforced concrete infilled frame model is designed by scaling down the real dimension of the model to ¼ scale down model. This model is designed with opening in the masonry infill part at the centre portion of the masonry infills. The single-bay seven-storey model is designed and analysed using the finite element modelling software. The stiffness and displacement of the reinforced concrete infilled frame is measured in this study. The lateral loading is applied at the one end of the frame at three storey different locations of storey. The load applied in the third, fifth and seventh floors of the frame and their deflections are measured for the respective loads. The loading pattern that are applied in the frame is static loading. The bare frame and the RC frame with infilled masonry having opening in it are compared each other by analytical model. The stiffness for IFCMO is 54.5% higher than the bare frame and IFPO frame due to the rigidity property of the cement mortar interface. This result confirms that IFCMO have better stiffness but the failure will be happened suddenly at one point. But, IFPO frame has its elastic interface medium resist the sudden failure and achieves maximum displacement than other frames.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
1 Introduction
The reinforced concrete member [1] and steel members [2] are used as a framed structure nowadays for all type of buildings. The precast members like beams and columns were also used as a framed structure [3]. In the recent research, the conventional reinforced concrete member and steel members were replaced with the glued—laminated timber fiber as a frame in structure [4]. The various frame members were practiced in the construction with infilled masonry as a combo model. The masonry infills are the un-reinforced members which is not having the specific codal provisions for designing. Various studied were made in analyzing the RC infilled frames under the lateral loading for measuring the stiffness, energy dissipation, drift factor, displacement and principal stresses [5, 6]. The masonry infills are the major portion of failure in all tall building structures. Many researchers have studied this effect of lateral loads in RC infilled framed structures and steel framed masonry infilled structures. The failure modes and crack propagation in different areas have been studied in detail by many authors. To overcome this issue, a diagonal strut model is designed at the loading end to the other beam column joint for resisting the lateral load transfer in the structure [6]. The strut models are not that much effective and it’s not having the practical ability to implement in the construction fields. Introducing the infill in between the RC members creates damage in the infill when the load is applied acting it. This load transfer is due to reinforced concrete possesses the flexible range where the un-reinforced masonry failed that property. To overcome this flexibility issue, the shear walls are constructed by some researchers and analysed the stiffness and strength properties [7]. This technique possesses greater self-weight that cannot be used in high-rise building. In recent days, an elastic medium like cork, lead, gaps, pneumatic and other elastic materials are used in the interface of the reinforced concrete member and masonry infilled panels [8]. These elastic mediums in between the members will resist the structure from damage and prevent the crack propagation and to avoid the structure from collapse. In the realistic models, the infilled walls possess openings for ventilations like door and windows. Some researchers have been made by incorporating the openings in the walls with varying size and location of the openings [4, 5, 7, 9,10,11]. The stiffness, displacement and stress were compared with the bare frame, RC infilled walls and RC infilled walls with openings. The members are tested by both static loading and cyclic loading [12]. Many researchers have tested the RC infilled frames with openings using up to three storey heights only. This study deals with the tall building effect of seven-storey RC infilled frames with openings in it.
2 Finite Element Model
The seven-storey RC infilled panel is tested using the Finite Element Analysis software (Abaqus). The panel is scaled down to 1/4 of prototype model and it is taken for testing. The dimensions of the specimens are described detail in Table 1.
The frame was cast using M20 grade of concrete for beams and columns, M40 grade of concrete for foundation. The steel used here was 16 mm main reinforcement for foundation, 10 mm main reinforcement for beams and columns and 6 mm bars for stirrups. The model was created using this material and the properties like modulus of elasticity and Poisson ratio were given to the model for respective materials. The openings in the infill are maintained as 50% from the masonry infill area.
3 Results and Discussion
3.1 Lateral Stiffness
The stiffness value is calculated by the load applied in the seven-storey frame at three different points and to the displacement. The stiffness is compared to the three different specimens like RC bare frame, RC infilled frame with opening comprising the cement mortar as interface material and RC infilled frame with opening comprising the pneumatic interface material. The variation in stiffness for bare frame another infilled frame with different interface materials is shown in Fig. 1. The stiffness is more in cement mortar interface RC frame when compared to bare frame and pneumatic interface frame. There is only a slight difference in bare frame and pneumatic interface frame. The peak shows that there is high stiffness in cement mortar interface frame due to more rigidity in interface materials. The stiffness for IFCMO is 54.5% higher than the bare frame and IFPO frame due to the rigidity property of the cement mortar interface. When comparing the stiffness for bare frame and IFPO the stiffness is 5.5% more in IFPO than the bare frame.
3.2 Lateral Displacement
The displacement results shows that there is a peak in bare frame when comparing to other frames (Fig. 2). This peak is due to the flexibility in RC member with having infill in between the RC members. There is less displacement in RC infilled frame with opening in the masonry infill with cement mortar interface due to the high stiffness in the interface medium when comparing to pneumatic interface. The displacement for the IFCMO is 55.8% lesser when compared to bare frame and IFPO due to the higher stiffness by cement mortar having better bonding with the masonry infilled materials than the IFPO (Fig. 3).
3.3 Minimum Principal Stress
Figure 4 clearly shows the stress is initially at the opposite end to the loading point. The initial stress is starts at the point where the columns are supported. The minimum principal stress is compared with the infilled frame cement mortar interface with opening (IFCMO) and infilled frame pneumatic interface with opening (IFPO). Figure 5 represents that there is an increase in stress for IFCMO when compared to IFPO. This result is due to the increase in stiffness by cement mortar interface bonded with the masonry infill than the pneumatic interface.
3.4 Maximum Principal Stress
The stress is distributed along the masonry infills which is transferred from the reinforced concrete member (Fig. 6). The maximum principal stress is measured when the peak load is applied to it. The stress is high for the IFCMO than the IFPO due to the increase in rigidity of interface material comparatively (Fig. 7). The infilled frame have the poor resistance in lateral load due to its stress distribution through the masonry infills.
4 Conclusion
The conclusions were made with the comparative results using different interface mediums:
-
1.
The RC fully infilled frame increases the poor resistance in lateral loading which is clearly proved by many researchers. So, this study deals with the partial infill in the high-rise buildings and their characteristics were studied in detail.
-
2.
The stiffness for IFCMO is 54.5% higher than the bare frame and IFPO frame due to the rigidity property of the cement mortar interface.
-
3.
When comparing the stiffness for bare frame and IFPO the stiffness is 5.5% more in IFPO than the bare frame.
-
4.
The displacement for the IFCMO is 55.8% lesser when compared to bare frame and IFPO due to the higher stiffness by cement mortar having better bonding with the masonry infilled materials than the IFPO.
-
5.
The IFPO frame is displaced more when comparing to IFCMO frame is due to the flexible interface material in between the masonry infill and RC member which transfers the load from RC member to the Pneumatic interface.
-
6.
The displacement has slight difference by 19.06% lesser when comparing the bare frame due to absence of infill in the bare frame.
-
7.
The maximum and minimum principal stresses show that the IFCMO has the maximum stress distribution due to its bonding and rigid property than IFPO.
References
Uva G, Porco F, Fiore A (2012) Appraisal of masonry infill walls effect in the seismic response of RC framed buildings: a case study. Eng Struct 34:514–526
Tasnimi AA, Mohebkhah A (2011) Investigation on the behavior of brick-infilled steel frames with openings, experimental and analytical approaches. Eng Struct 33:968–980
Wang L, Tang Z-Y, Li Y, Qian K (2019) Seismic behavior of masonry-infilled precast concrete frames considering effects of opening. Construct Build Mater 211:756–770
Xue J, Ren G, Qi L, Zhang X (2021) Lateral behavior of glued-laminated timber frame infilled with light-wooden-frame wall hybrid system: experimental and numerical analysis. Structures 30:352–367
Chen X, Liu Y (2015) Numerical study of in-plane behaviour and strength of concrete masonry infills with openings. Eng Struct 82:226–235
Mohamed H, Romão X (2020) Analysis of the performance of strut models to simulate the seismic behaviour of masonry infills in partially infilled RC frames. Eng Struct 222:111–124
Zhai X, Zhang X, Cao C, Hu W (2019) Study on seismic performance of precast fabricated RC shear wall with opening filling. Construct Build Mater 214:-539–556
Thirumurugan V, Muthu Kumar S, Husam Ahmed W, Ganesan TP, Satyanarayanan KS (2015) Behavior of infilled frames with different interface materials. RASCE
Liberatore L, AlShawa O, Marson C, Pasca M, Sorrentino L (2020) Out-of-plane capacity equations for masonry infill walls accounting for openings and boundary conditions. Eng Struct 207:110–198
Penavaa D, Sarhosis V, Kozar I, Guljas I (2018) Contribution of RC columns and masonry wall to the shear resistance of masonry infilled RC frames containing different in size window and door openings. Eng Struct 172:105–130
Yekrangnia M, Asteris PG (2020) Multi-strut macro-model for masonry infilled frames with openings. J Build Eng 32:101–683
Morandi P, Hak S, Magenes G (2018) Performance-based interpretation of in-plane cyclic tests on RC frames with strong masonry infills. Eng Struct 156:503–521
Thirumurugan V, Ganesan TP Studies on the use of pneumatic interface in reinforced concrete infilled frames. http://hdl.handle.net/10603/220960
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Kumar, G.P., Thirumurugan, V., Satyanarayanan, K.S. (2022). The Behaviour of Seven-Storey Infilled RC Frame with Opening in Infill—An Analytical Study. In: Satyanarayanan, K.S., Seo, HJ., Gopalakrishnan, N. (eds) Sustainable Construction Materials. Lecture Notes in Civil Engineering, vol 194. Springer, Singapore. https://doi.org/10.1007/978-981-16-6403-8_3
Download citation
DOI: https://doi.org/10.1007/978-981-16-6403-8_3
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-6402-1
Online ISBN: 978-981-16-6403-8
eBook Packages: EngineeringEngineering (R0)